• Title/Summary/Keyword: Water Quality Regulation

Search Result 130, Processing Time 0.038 seconds

A Investigation and Analysis of Water Temperature by Juam Regulation Dam Outflow in Downstream and Suncheon Bay (주암조절지댐 방류수에 따른 하천 및 순천만 일대 수온변화 조사분석)

  • Lee, Hyeon No;Jung, Kwan Sue;Cheon, Geun Ho;Hur, Young Teck
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.6
    • /
    • pp.501-509
    • /
    • 2015
  • Lately multipurpose dam is required to consider various interests such as quality, ecological environment as well as flood control, water supply, hydropower generation, etc. The objective of this study is to investigation and analysis of water temperature in the areas where there are social conflicts due to cold water outflow. In this study, we monitored water temperature of Juam regulation dam, downstream river, Suncheon bay in a long term period and performed comparative analysis on a change of water temperature in downstream river and Suncheon bay by using three-dimensional numerical mode (EFDC) considering various external factors such as water outflow amount. The result of monitoring and numerical modelling indicates that effects of cold water outflow takes place from april to september. Also effects of the low temperature discharge of dam was complicatedly altered by various factors such as outflow time and amount, weather and tide level conditions etc. The result of this study can be utilized as a basic data for establishing improvement of dam operation plan to minimize negative effects of dam's cold temperature water outflow to downstream river and coastal area.

The Long-Term Variations of Water Quality in Masan Bay, South Sea of Korea (남해 마산만 수질의 장기 변동 특성)

  • Kwon, Jung-No;Lim, Jae-Hyun;Shim, Jeonghee;Lee, Jangho;Choi, Tae-Jun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.212-223
    • /
    • 2014
  • For the better understanding of long-term and seasonal variations of water quality in Masan Bay, South Sea of Korea, we analyzed the archive data monitored at three stations of the bay during the last 13 years (2000-2012). The average concentrations of the chemical oxygen demand (COD), the dissolved inorganic nitrogen (DIN) and the dissolved inorganic phosphorus (DIP) during the monitoring period are $2.70{\pm}0.09{\mu}/L$, $19.66{\pm}1.84{\mu}m$ and $1.39{\pm}0.13{\mu}m$ in surface water, respectively, and $2.22{\pm}0.07{\mu}/L$, $18.53{\pm}1.36{\mu}m$ and $1.47{\pm}0.12{\mu}m$ in bottom water, respectively. The trophic state of the surface water was the eutrophic level in Masan Bay during the four seasons. The DIN concentrations of both surface and bottom waters increased from August to November and showed the highest average in November. However, The DIN decreased from February to May and showed the lowest average in May. The concentrations of the DIP and the dissolved silicate (DSi) in bottom waters had the highest averages in August because of the high water temperature and oxygen deficient condition. The results of correlation analysis and factor analysis showed that the main factors of surface waters were inflow of nutrients from terrestrial areas and internal production, and the main factors of bottom waters were the variations of the dissolved oxygen (DO), the DIP, and the DSi. The DIN and DIP average concentrations (2007~2012) had decreased in range of 68.1%~76.0% and 66.2~76.6%, respectively from 2007 in which the "Regulation of Total Emission" was established in Masan Bay. Therefore, it could have had positive effects on water quality improvement to take the "Regulation of Total Emission" and other actions such as reducing water pollutions in Masan Bay from 2007.

A Study on the Stable Operation of High Sodium Hypochlorite Generation (고농도 차아염소산나트륨 발생장치의 안정적 운영에 관한 연구)

  • Cho, Haejin;Na, Chanwook;Ko, Sungho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.69-74
    • /
    • 2017
  • Sodium hypochlorite, used as water disinfectant, is generated by electrolysis of salt. Compared to chlorine gas disinfection, it is free from high-pressure gas regulation and does not generate toxic gas, so it is increasingly used as a safe disinfectant. Despite these advantages, the concentration of sodium hypochlorite decreases with temperature during long-term storage, and the amount of chlorate increases when a large amount is added, it has mainly been applied to small-scale waterworks. To solve this problem, high sodium hypochlorite generation was developed. In this study, the changes of concentration and chlorate of sodium hypochlorite with time has been studied. As a result of the test, it was found that the usable period of sodium hypochlorite produced at a certain temperature or less was increased from 1.5 days to 13 days. Overall, sodium hypochlorite can be applied even in large-scale waterworks, which makes operation more stable and also reduces the disinfection byproducts, thus it contributed greatly to securing water quality.

A Study on Characteristics of Water Quality in Wastewater according to the Washing of Municipal Solid Waste Incinerator (MSWI) Ash

  • Byun, Mi-Young;Kim, Hyung-Seok;Ahn, Ji-Whan;Kim, Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.296-300
    • /
    • 2001
  • In order to recycle the incineration ash (bottom ash and fly ash) generated from the incineration of municipal waste for a cement material, salts as well as heavy metal should be removed by the stabilization treatment. Most of these heavy metal and over 80% of salts are removed by a washing as a pre-treatment. However, wastewater which is another pollutant is generated by a washing, then proper treatment should be developed. First the characteristics of incineration ashes collected from two domestic full-sized incinerators were investigated and removal rate of salts and heavy metals from them also studied. The wastewater quality was compared to the criteria of the regulation by analyzing the characteristics of generated wastewater during the washing of incineration ash as a condition of liquid/solid ratio. Also, we tried to used this experimental results for the basic data to develop proper processing technique of municipal waste.

  • PDF

Issue Difference of Ecosystem Service Demand and Supply through Text Mining Analysis: Case Study of Shiheung using Complaints and Urban Planning Materials (텍스트 마이닝 분석을 통한 생태계서비스 수요-공급의 이슈 차이분석 - 시흥시 민원과 도시계획 자료를 활용하여 -)

  • Lee, Jae-hyuck;Park, Hong-jun;Kim, Il-kwon;Kwon, Hyuk-soo
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.63-71
    • /
    • 2018
  • The comparison of demand and supply is needed for efficient ecosystem services planning. However, the gap between them cannot be analyzed as existing studies mainly dealt with only the supply of ecosystem services. This study compares the demand and supply of ecosystem services in Shiheung using environmental complaints and urban planning by semantic network analysis. As a result, 'air' and 'water' quality are magnified in demand, 'energy' and 'water' are crucial in supply. This result presents that citizen ask for the improvement of air quality in regulation services, although local government has plans for energy support in provisioning services. Periodic ecosystem services demand and supply monitoring will be the base of effective ecosystem services planning, which reduce insufficiency and surplus.

Establishment of Resilient Infrastructures for the Mitigation of an Urban Water Problem: 2. Robustness Assessment of Structural Alternatives for the Problems of Water Pollution (도시 물 문제 저감을 위한 회복탄력적 사회기반시설 구축: 2. 수질오염 문제 구조적 대안의 내구성 평가)

  • Jung, Jihyeun;Lee, Changmin;An, Jinsung;Kim, Jae Young;Choi, Yongju
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.182-188
    • /
    • 2016
  • This study evaluated structural alternatives for managing water quality problems by reinterpreting and then applying the robustness-cost index (RCI) for urban flood problems. Cases of endogenous hormone pollution in treated sewage and proliferation of protozoa in intake-water were chosen as representative examples because they have different types of regulation standards for the treatment. Current facilities and structural alternatives with robustness indices (RIs) greater than unity were determined to be robust. The RI was combined with the cost index (CI) to obtain the RCI values. For the endogenous hormone pollution in treated sewage, a human-oriented estrogen $17{\beta}$-estradiol was selected as a target pollutant. The RI and RCI values for a structural alternative, extension of the current sewage treatment facility for advanced treatment, were greater than the values for the current practice of conventional activated sludge process. For the intake-water pollution by protozoa, UV and ozone disinfection facilities were evaluated for inactivation of Cryptosporidium parvum. The RCI values for ozone disinfection were greater than those for UV disinfection. Based on the results and the logics involved in the calculation of RCI for water quality issues we studied, we proposed procedures for establishing and implementing structural alternatives for the restoration from and prevention of outbreaks of water quality problems.

Health and Ecological Risk Assessment of PCBs-exposure by Regulation Guideline Change (규제기준 변화에 다른 PCBs 인체 및 생태 위해성 평가)

  • Lim, Young-Wook;Yang, Ji-Yeon;Jung, Jong-Soo;Lee, Yong-Jin;Kim, Jin-Young;Lee, Chung-Soo;Ko, Seong-Joon;Shin, Dong-Chun
    • Environmental Analysis Health and Toxicology
    • /
    • v.23 no.1
    • /
    • pp.53-62
    • /
    • 2008
  • In the present study, the concentration levels of polychlorinated biphenyls (or PCBs) in the environments in Korea are estimated based on some measured data in Korea, in comparison with the data from the other countries. Even though PCBs were banned as electrical fluids in 1970s in Korea, PCBs are still detected in the environment. PCBs levels in Korea are greatly lower than those in other countries, which are gradually decreased as well. However, the measured data are not sufficient in both numbers and quality, to estimate the average PCBs levels in Korea. The regulation limit on polychlorinated biphenyls (or PCBs) is 2mg/kg (ppm), which is too low compared to 50 ppm of many other countries including U.S. With this strict regulation, there are many problems expected, for example, in the analysis of PCBs in the transformers using in the field as well as the safe treatment of PCBs. The risk assessment on the PCBs in the environment is surely necessary prior to the change in the limit. Also the PCBs concentration monitoring in the environmental media (i.e. air, water, soil and sediment) and exposure assessment will be essential for the accurate risk assessment. If the PCB-waste guideline maintain as 2 ppm after 10 years, the excess cancer risk of PCBs exposure by ambient air, drinking water and soil was $10^{-8}$. But if the guideline mitigate as 50 ppm after 10 years, the cancer risk was increased by $10^{-7}$. The ecological risk quotient by regulation change was not exceed '1'.

A Study on the Environmental Carrying Capacity Assessment of Chongju City (도시 환경용량평가에 관한 연구 -청주시를 사례로-)

  • Lim, Jae-Ho;Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.1
    • /
    • pp.25-36
    • /
    • 2002
  • The purpose of this study is to assess the environmental carrying capacity of Chongju City for the environmental management and the urban growth management. The urban environmental carrying capacity assessment of the city by the index of ecological footprint(EF), shows that the ecosystem of the city has been overloaded and most of the deficiencies has come from outside of the city. The EF index, the area of land per capita required for production and consumption in the city, was 1.731 ha per capita in 1989 and 1.901 ha per capita in 1999. On the other side, the ecologically productive land is 0.0175 ha per capita. It means that every citizen owes 1.88 ha per capita to the ecosystem in 1999. The land consumption of the city has increased by 0.1705 ha per capita during the last 10 years. The capacity of infrastructure and the service supply estimated by the Onishi model does not exceed the demand of the city in 1999. But the rapidly increasing population and fast urban growth need the expansion of the capacity. The water supply capacity of the city appears to be sufficient in 1999, but the water supply demand will increase in the future. The capacity of sewage treatment facilities seems to be sufficient, but the higher level of sewage treatment facilities should be adopted for the improvement of water quality as the generation of sewage will increase and its characteristics will also make the wastewater treatment difficult. Due to the decrease of solid waste generated, the land fill capacity for solid waste disposal is not insufficient at present, but the capacity will be saturated in the near future. Therefore, the scientific management system of solid wastes should be introduced. The air quality of the city meets both the national air quality standard and WHO recommendation standard, but the strong regulation and control of automobile emission gas such as CO, $CO_2$, NOx and HC is required for clean air.

Analysis of Future Trends for Refractory Dissolved Organic Carbon in the Nakdong River Basin using Elasticity Theory (탄성도 이론을 이용한 낙동강유역 난분해성 용존 유기탄소 미래 추세 분석)

  • Park, Yoonkyung;Choi, Daegyu;Lee, Jae Woon;Kang, Limseok;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.4
    • /
    • pp.476-488
    • /
    • 2013
  • Refractory Dissolved Organic Carbon (RDOC) is becoming more important index on management of water quality, water regulation as well as ecosystem management. We analyzed trends of RDOC using elasticity in the Nakdong river basin. If climate elasticity of streamflow is positive, change of streamflow can be defined by the proportional change in a climatic variable such as precipitation and temperature. Elasticity of streamflow to precipitation and elasticity of RDOC to precipitation were estimated in the present, and we also analyzed the variation of elasticity in the future using climate change scenarios, RCP 8.5/ 4.5. Mean streamflow elasticity is 1.655, and mean RDOC elasticity is 1.983. RDOC is more sensitive to precipitation change than streamflow. The variation of RDOC is directly proportion to precipitation in all scenarios, but the Load of RDOC is dependent on precipitation as well as others. There is a need for additional correlation analysis between RDOC and other factors for accurate prediction.

Inactivation of Legionella pneumophila by Electrochemical Disinfection (전기화학적 소독에 의한 Legionella pneumophila 불활성화)

  • Park, Young-Seek;Kim, Dong-Seog
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.613-619
    • /
    • 2007
  • This study has carried out a performance of dimensionally stable anode for the purpose of disinfection of Legionella pneumophila in water. Three kinds of electrode were prepared by plating and thermal deposition, which were coated by the oxides of Pt, Ru and Ir on Ti metal surface, respectively. The order of disinfection performance for Legionella pneumophila was Ru/Ti > Ir/Ti > Pt/Ti. Free Cl and $ClO_2$ generation of Ir/Ti electrode was higher than that of two electrodes. However, the concentrations of generated $H_2O_2$ and $O_3$ of the Ru/Ti electrode were highest among the three electrodes. The higher NaCl concentration was, the more oxidants was generated and disinfection effect was increased. However, optimum NaCl dosage was 0.0125% due to the regulation on the conductivity and $Cl^-$ concentration for the cooling water quality of air conditioning and refrigeration equipment. With the increase of current, oxidants was more generated and following disinfection effect was increased. The increase of electrode distance reduced oxidants generation due to the low electric power, and their disinfection effect was decreased accordingly.