• Title/Summary/Keyword: Water Quality Regulation

Search Result 130, Processing Time 0.034 seconds

Evaluation for Contents of Contaminants and Leaching Characteristics of Bottom Ash (바텀애쉬의 유해물질 함량 측정 및 용출특성 평가연구)

  • Koh, Taehoon;Lee, Sungjin;Shin, Minho;Kim, Byongsuk;Lee, Jeakeun;Lee, Taeyoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.77-83
    • /
    • 2010
  • In this study, we tried to determine any detrimental effects on water quality when bottom ash obtained from a coal-fired power plant intended to be used as a fill material in construction sites. Physical-chemical properties of bottom ash were determined using proximate analysis, elemental analysis, XRD, and XRF. Classification of bottom ash as a waste material and soil contamination due to the use of bottom ash were performed by Korea waste standard leaching test and soil toxicity test, respectively. Results of leaching tests were compared to the regulations for water quality and groundwater quality and no harmful effects on water quality were found. Most of heavy metals in leachate were below detection limits but trace amount of $Cr^{6+}$ was found. However, concentration of $Cr^{6+}$ was below the regulation criteria. Column leaching tests indicated that concentrations of Pb and Zn were slightly higher than regulations but below regulations within 1 PVE, but concentrations of sulfate were 10 times higher than regulation and thus, the required time to reach regulation was almost 8 PVE.

A Study on the Drinking Water Quality and Contamination Sources in a Rural Area (일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

A study on performance analysis and merging techniques of sensors in water quality measurement (수질계측센서의 성능분석 및 센서 융합기술에 관한 연구)

  • Yang Keun-Ho;Yoo Byung-Kook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.3
    • /
    • pp.143-148
    • /
    • 2006
  • There are need to manage the water quality to supply an safety to consumer through pipe and reservoir the drinking water that produced in a clean water reservoir. However, a management of water quality and monitoring in reservoir have never been performed. Recently, the government has enforced standards of water quality. However, we have a inferior technology of water quality as compared with one in USA, Japan, Germany, etc. In case of water quality inspection and analysis equipments, sensor technology is very important to improve the water quality inspection and to develop the analysis equipments. In this paper, we analyze a law and a regulation for management of drinking water quality, and propose the measurement standards of drinking water quality in pH, conductivity, residual chloride, turbidity and water temperature. Then, we analyze electrode sensors that interference within pH, conductivity, residual chloride in interference experiment.

  • PDF

Water Quality Impact Assessment in Korea - Comparing with the Integrated Control of Pollutant-Discharging Facilities - (수질분야 환경영향평가의 개선방안 - 환경오염시설의 통합관리와 대비하여 -)

  • Lee, Jong Ho;Cho, Jae Heon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.5
    • /
    • pp.331-343
    • /
    • 2017
  • The important changes in water environment management in Korea can be summarized as the enactment of Act on the Integrated Control of Pollutant-Discharging Facilities. Therefore water quality impact assessment should be reexamined and be revised. This study examines the present water quality impact assessment items (permissible discharge limits, standards for effluent water quality including Total Pollutant Load Management System) and considers the land use regulation for water quality conservation and NVZs(Nitrate Vulnerable Zones of EU and England). It also considers lately adopted standards(maximum discharge standards, permissible discharge standards, and marginal discharge standards etc) based on Act on the Integrated Control of Pollutant-Discharging Facilities and then compares Korean BAT and its counterpart control technology of U.S.A. And it also compares the items of water quality impact assessment with those of Integrated Control of Pollutant-Discharging Facilities, based on EIS reporting items. This study suggests five improvement measures for water quality impact assessment. First reflection of discharge impact analysis on impact prediction and assessment, second reflection of permissible discharge standards on agreed standards in the EIA procedure, third, reflection of diversified BAT on mitigation measures in the EIA procedure, forth introduction of land use regulation such as NVZs, finally strengthening linkage between water quality items and land use items etc.

Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data (2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석)

  • Son, Younggyu;Na, Seungmin;Im, Tae Hyo;Kim, Sang-hun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

A Study on Interferences of Monochloramine in the Measurement of Ammonia by Phenate Method (Phenate 법으로 암모니아 분석시 염화아민의 방해 작용에 관한 연구)

  • Yoon, Je-Yong;Lee, Sang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.1
    • /
    • pp.45-51
    • /
    • 1998
  • The determinations of ammonia in water for drinking purpose served as one basis of judging the sanitary quality of water for a great many years. However, presently ammonia regulation varies depending on countries. In USA and Canada, ammonia is added to water for chloramination process. However, for korea, there is ammonia regulation of treated water in Korea which should not exceed 0.5mg/l as $NH_3-N$. There was a report exceeding 0.5mg/l of ammonia in chlorinated water when the famous drinking water contamination episode happened in the downstream of Nadong River, 1994. With lack of sewer distribution system and treatment plants of domestic wastes, many water treatment plants have a difficulty of complying with ammonia regulation in treated water. Breakpoint chlorination is usually performed to get rid of ammonia. The method which is allowed to measure ammonia in Korea is Phenate method. However, it would be undesirable to use Phenate method for measuring ammonia in chlorinated water if Phenate method would not differentiate ammonia from chloramine. A good possibility of interferences in measurement of ammonia exists because Phenate method include the step of the formation of chlorine and would not differentiate chloramine which is formed as a result of reaction between chlorine and ammonia. This study was on inaccuracy of Phenate method for measuring ammonia of chlorinated water when chloramine and ammonia coexist. This study found that Phenate method measured all chlormaine as ammonia. Ammonia measurement by ion chromatography confirmed this results. Finally, the result from this study suggests that ammonia measurement by Phenate method in chlorinated water should be revised accordingly.

  • PDF

Development of Load Duration Curve Methodology for TMDL Evaluation (오염총량평가를 위한 부하지속곡선 개발 및 적용)

  • Kang, Du-Kee;Kang, Soon-Ku;Kim, Sang-Dan;Shin, Hyun-Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.652-656
    • /
    • 2007
  • The major streams in South Korea have established the TMDL(Total Maximum Daily Loads) regulation for just 4 years. Traditional concepts in water quality management in South Korea are based upon the selection of a design streram flow which is 10-year averged flow exeedance probability 75%(Q275). That is, a single flow value based upon average long term flow conditions is chosen for application in dilution calculations, permit design, water quality modeling, etc. While these TMDLs seems to satisfy the requirement of the target water quality regulations, they have contributed little to any watershed/waterbody assessment and restoration plans. These types of TMDLs do little to characterize the problems the TMDLs are intended to address. For TMDLs to be more beneficial in the assessment and implementation process, TMDLs should reflect adequate water quality across flow conditions rather than at a single flow value such as average daily flow. In this paper, we developed LDC (load duration curve) methodology for theevaluation of Korean TMDL evaluation based on watershed scaled, physically based on SWAT(Soil and Water Assessment Tool) model.

  • PDF

Assessment of Korean Water Quality Standards for Effluent Discharged from the Dye Industry Based on Acute Aquatic Toxicity Tests Using Microbes and Macroinvertebrates (염색폐수의 수질독성시험을 이용한 한국의 수질배출허용기준 평가연구)

  • Kim, Young-Hee;Lee, Min-Jung;Choi, Kyung-Ho;Eo, Soo-Mi;Lee, Hong-Keun
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Acute aquatic toxicity of effluents discharged from five dyeing plants in Gyeong-gi province were evaluated to assess whether the current Korean water quality standards(KWQS) could protect aquatic life. Chemical analyses of all parameters regulated under KWQS, except for E-coli, were also carried out to determine regulation compliance of the samples. All the effluent samples were satisfied with KWQS except for the color in only one sample. In acute Daphnia magna toxicity tests, significant mortality was observed in one of five samples and EC50 was 12.1%(95% confidence interval 9.1-16.2), which was in compliance with KWQS. The result of the Microtox assay indicated that acute microbial toxicity existed in effluents from three out of five plants, two of which were in compliance with KWQS. The agreement between regulation compliance of chemical concentrations of effluent and observed toxicity from various biological toxicity tests was very poor to fair (kappa = 0.194~0.250). The data presented suggest that exposure to dyeing wastewater which were in compliance with Korean water quality standards may not be safe to aquatic biota, and multiple tropical levels should be considered in aquatic toxicity monitoring of dyeing industry.

Development of an Analytical Model of BOD(AMB) for Total Pollution Load Regulation (오염총량관리를 위한 분석적 BOD모델(AMB) 개발)

  • Kim, Gyeong-Seop;An, Tae-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.6
    • /
    • pp.775-782
    • /
    • 2000
  • Water quality models can be applied to manage the regional water quality problems and to estimate the target and allowable pollution load in watershed effectively. Since the models such as QUAL2E, W ASP5 and HSPF need many data and are not easily applied in real systems, the water quality model, which would be simple and easily applicable, has been required. Thus, an Analytical Model of BOD(AMB) considering travel time of pollutant was developed for the total pollution load regulation in drainage basin. It was found that the main stream length of a sub-basin in the AMB should be shorter than 7km and the length of distributed pollutant load should also be shorter than 3.5km in a sub-basin. The basin in the AMB could be divided into sub-basins with almost same hydraulic characteristics and reaction rate constant satisfying the proposed stream length. The running results of the AMB in a small stream were very close to the results of QUAL2E, which is widely used one in the world. Therefore, the AlVIB can be used to regulate the total pollution load in drainage district by local government.rnment.

  • PDF

Investigating Water Quality Data of Finished Water in Domestic Water Treatment Plants (1994-1998) (국내 정수장 정수 수질자료의 특성분석 (1994년-1998년까지 5년간 자료를 중심으로))

  • Yoon, Jeyong;Cho, Soonhaeng;Kim, Haeshim
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.431-443
    • /
    • 2000
  • Water quality data from water treatment plants in Korea during 1994-1998 were investigated to find out the characteristics of their non compliance. The number of plants surveyed were approximately 600 and the number of samples were over 30,000. Ten parameters of water quality selected in this study and their non compliance % (inside parenthesis) were as follows: Heterotrophic plate count (0.14%), Total coliforms (0.08%), $NH_3$-N (0.29%), $NO_3$-N (0.14%), THMs (0.02%), Turbidity (0.11%), Residual chlorine (5.5%), $KMnO_4$ consumption (0.04%), Hardness (0.03%), pH (0.07%). These levels of non compliance were compared to those obtained from WIDB (Water Industry Database, 1996) of American Water Works Association. This study strongly supported that small water plants (<10,000 tons/day) were more vulnerable in meeting the regulation criteria of many water quality parameters such as Heterotrophic plate count. Total coliforms, $NO_3$-N, THMs, Turbidity, Residual chlorine, $KMnO_1$ consumption, Hardness and pH. The $NH_3$-N concentration was especially high in winter and its violation was frequently found in the specific areas such as the downstream of major rivers. The average THMs concentration was surprisingly low, indicating $13{\mu}g/L$ which is 43% of US. Accordingly, these characteristics must be reflected in establishing the effective management of water quality policy of drinking water in Korea.

  • PDF