• Title/Summary/Keyword: Water Quality Measurement

Search Result 533, Processing Time 0.026 seconds

Characteristics and Risk Assessment of Heavy Metals in the Stormwater Runoffs from Industrial Region Discharged into Shihwa Lake (시화호 산업지역 강우유출수 내 중금속 유출특성 및 위해성 평가)

  • Ra, Kongtae;Kim, Joung-Keun;Lee, Jung-Moo;Lee, Seung-Yong;Kim, Eun-Soo;Kim, Kyung-Tae
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.4
    • /
    • pp.283-296
    • /
    • 2014
  • The distribution of heavy metals in the stormwater runoffs from industrial sites around Shihwa Lake that implements the total pollutant load management system (TPLMS) was studied to characterize the temporal changes of metal concentrations and to assess the ecological risk in dissolved and particulate phases of the selected metals. The dissolved Co and Ni concentration demonstrated first flush and tended to decrease with increasing of the duration of rainfall. The intensity of precipitation was found to be the main controlling factor of particulate metals in the stromwater runoffs. The particulate concentration of Pb accounted for 97.2% so the particulate phase was its main form. Other metals followed the sequence: Pb>Cu>Cd>Co>Zn>Ni. The particulate-dissolved partitioning coefficient ($K_d$) indicated that the $K_d$ of Pb were bigger than that of other metals because the metal Pb in the stormwater runoffs is quickly removed into the particulate phase. In a single day rainfall event, total runoff fluxes for total metals as the sum of dissolved and particulate forms through only two sewer outlets were 2.21 kg for Co, 30.5 kg for Ni, 278.3 kg for Cu, 398.3 kg for Zn, 0.39 kg for Cd and 40.0 kg for Pb, respectively. Given the annual rainfall, the number of rain days and the basin area for total pollutant load management system (TPLMS) of Shihwa area, enormous amount of non-point metal pollutants were entered into Lake with any treatment. The dissolved metals (e.g., Ni, Cu and Zn) in the stormwater runoffs exceeded the acute water quality criteria. Additionally, all metals were significantly enriched in the particulate phase and exceeded the PEL criteria of sediment quality guidelines (SQGs). These results indicated that the heavy metals in the stormwater runoffs may pose a very high ecological risk to the coastal environments and ecosystem.

Intensity Modulated Radiation Therapy Commissioning and Quality Assurance: Implementation of AAPM TG119 (세기조절방사선치료(IMRT)의 Commissioning 및 정도관리: AAPM TG119 적용)

  • Ahn, Woo-Sang;Cho, Byung-Chul
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • The purpose of this study is to evaluate the accuracy of IMRT in our clinic from based on TG119 procedure and establish action level. Five IMRT test cases were described in TG119: multi-target, head&neck, prostate, and two C-shapes (easy&hard). There were used and delivered to water-equivalent solid phantom for IMRT. Absolute dose for points in target and OAR was measured by using an ion chamber (CC13, IBA). EBT2 film was utilized to compare the measured two-dimensional dose distribution with the calculated one by treatment planning system. All collected data were analyzed using the TG119 specifications to determine the confidence limit. The mean of relative error (%) between measured and calculated value was $1.2{\pm}1.1%$ and $1.2{\pm}0.7%$ for target and OAR, respectively. The resulting confidence limits were 3.4% and 2.6%. In EBT2 film dosimetry, the average percentage of points passing the gamma criteria (3%/3 mm) was $97.7{\pm}0.8%$. Confidence limit values determined by EBT2 film analysis was 3.9%. This study has focused on IMRT commissioning and quality assurance based on TG119 guideline. It is concluded that action level were ${\pm}4%$ and ${\pm}3%$ for target and OAR and 97% for film measurement, respectively. It is expected that TG119-based procedure can be used as reference to evaluate the accuracy of IMRT for each institution.

Changes of Meat Quality and Antioxidation Activity in the Loin and Ham of Korean Native Black Pigs during Frozen Storage (재래흑돼지고기의 냉동저장기간 동안의 품질 및 항산화 특성 변화)

  • Gil, Juae;Kim, Dongwook;Kim, Hee-Jin;Yoon, Ji-Yeol;Pak, Jae-In;Park, Beom-Young;Ham, Jun-Sang;Jang, Aera
    • Journal of Life Science
    • /
    • v.25 no.7
    • /
    • pp.740-747
    • /
    • 2015
  • This study was carried out to evaluate changes in the meat quality and antioxidation activity in the loin and ham of Korean Native Black Pigs (KNBP) during frozen storage at −18℃ for 150 days. The pH value of the loin was decreased as storage days progressed, while the pH value of the ham showed no consistent changes with storage days. The lightness (L*) of the loin did not show any significant reduction until day 120, whereas L* of the ham was significantly declined throughout the storage period (p<0.05). The redness (a*) values of the loin and ham were significantly decreased as storage progressed. The water holding capacity of the loin was decreased by day 30 and that value was maintained until the end of storage. The initial total numbers of microorganisms in the loin and ham were 4.88 and 5.16 Log CFU/g, respectively and these numbers were significantly decreased by day 30 (p<0.05). The levels of 2-thiobarbituric acid reactive substances (a measurement of lipid oxidation) in the loin and ham ranged from 0.057-0.069 and 0.052-0.087 mg MDA/kg meat, respectively, until storage day 150. Volatile basic nitrogen values of the loin and ham ranged from 15.13-16.55 and 16.05-16.23 mg%. Oxygen radical absorbance capacities and carnosine contents of the loin and ham were significantly decreased during frozen storage for 3 months (p<0.05). In summary, the meat quality of the loin and ham from KNBP was somewhat decreased during frozen storage. However, the levels of antioxidants and dipeptides with antioxidant activity were significantly decreased in pork loin and ham during frozen storage.

KoFlux's Progress: Background, Status and Direction (KoFlux 역정: 배경, 현황 및 향방)

  • Kwon, Hyo-Jung;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.12 no.4
    • /
    • pp.241-263
    • /
    • 2010
  • KoFlux is a Korean network of micrometeorological tower sites that use eddy covariance methods to monitor the cycles of energy, water, and carbon dioxide between the atmosphere and the key terrestrial ecosystems in Korea. KoFlux embraces the mission of AsiaFlux, i.e. to bring Asia's key ecosystems under observation to ensure quality and sustainability of life on earth. The main purposes of KoFlux are to provide (1) an infrastructure to monitor, compile, archive and distribute data for the science community and (2) a forum and short courses for the application and distribution of knowledge and data between scientists including practitioners. The KoFlux community pursues the vision of AsiaFlux, i.e., "thinking community, learning frontiers" by creating information and knowledge of ecosystem science on carbon, water and energy exchanges in key terrestrial ecosystems in Asia, by promoting multidisciplinary cooperations and integration of scientific researches and practices, and by providing the local communities with sustainable ecosystem services. Currently, KoFlux has seven sites in key terrestrial ecosystems (i.e., five sites in Korea and two sites in the Arctic and Antarctic). KoFlux has systemized a standardized data processing based on scrutiny of the data observed from these ecosystems and synthesized the processed data for constructing database for further uses with open access. Through publications, workshops, and training courses on a regular basis, KoFlux has provided an agora for building networks, exchanging information among flux measurement and modelling experts, and educating scientists in flux measurement and data analysis. Despite such persistent initiatives, the collaborative networking is still limited within the KoFlux community. In order to break the walls between different disciplines and boost up partnership and ownership of the network, KoFlux will be housed in the National Center for Agro-Meteorology (NCAM) at Seoul National University in 2011 and provide several core services of NCAM. Such concerted efforts will facilitate the augmentation of the current monitoring network, the education of the next-generation scientists, and the provision of sustainable ecosystem services to our society.

Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams (고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발)

  • Shin Dong Oh;Park Sung Yong;Ji Young Hoon;Lee Chang Geon;Suh Tae Suk;Kwon Soo IL;Ahn Hee Kyung;Kang Jin Oh;Hong Seong Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.381-390
    • /
    • 2002
  • Purpose : To develop a dose calibration program for the IAEA TRS-277 and AAPM TG-21, based on the air kerma calibration factor (or the cavity-gas calibration factor), as well as for the IAEA TRS-398 and the AAPM TG-51, based on the absorbed dose to water calibration factor, so as to avoid the unwanted error associated with these calculation procedures. Materials and Methods : Currently, the most widely used dosimetry Protocols of high energy photon beams are the air kerma calibration factor based on the IAEA TRS-277 and the AAPM TG-21. However, this has somewhat complex formalism and limitations for the improvement of the accuracy due to uncertainties of the physical quantities. Recently, the IAEA and the AAPM published the absorbed dose to water calibration factor based, on the IAEA TRS-398 and the AAPM TG-51. The formalism and physical parameters were strictly applied to these four dose calibration programs. The tables and graphs of physical data and the information for ion chambers were numericalized for their incorporation into a database. These programs were developed user to be friendly, with the Visual $C^{++}$ language for their ease of use in a Windows environment according to the recommendation of each protocols. Results : The dose calibration programs for the high energy photon beams, developed for the four protocols, allow the input of informations about a dosimetry system, the characteristics of the beam quality, the measurement conditions and dosimetry results, to enable the minimization of any inter-user variations and errors, during the calculation procedure. Also, it was possible to compare the absorbed dose to water data of the four different protocols at a single reference points. Conclusion : Since this program expressed information in numerical and data-based forms for the physical parameter tables, graphs and of the ion chambers, the error associated with the procedures and different user could be solved. It was possible to analyze and compare the major difference for each dosimetry protocol, since the program was designed to be user friendly and to accurately calculate the correction factors and absorbed dose. It is expected that accurate dose calculations in high energy photon beams can be made by the users for selecting and performing the appropriate dosimetry protocol.

An Assessment of Post-Injection Transmission Measurement for Attenuation Correction With Rotating Pin Sources in Positron Emission Tomography (양전자방출단층촬영(PET)에서 회전 핀선원과 투과 및 방출 동시 영상 방법을 이용한 감쇠보정 방법 특성에 관한 고찰)

  • Lee, J.R.;Choi, Y.;Lee, K.H.;Kim, S.E.;Chi, D.Y.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.533-540
    • /
    • 1995
  • Attenuation correction is important in producing quantitative positron emission tomography (PET) images. Conventionally, photon attenuation effects are corrected using transmission measurements performed before tracer administration. The pre-injection transmission measurement approach may require a time delay between transmission and emission scans for the tracer studies requiring a long uptake period, about 45 minutes for F-18 deoxyglucose study. The time delay will limit patient throughput and increase the likelihood of patient motion. A technique lot performing simultaneous transmission and emission scans (T+E method) after the tracer injection has been validated. The T+E method substracts the emission counts contaminating the transmission measurements to produce accurate attenuation correction coefficients. This method has been evaluated in experiments using a cylindrical phantom filled with background water (5750 cc) containing $0.4{\mu}Ci/cc$ of F-18 fluoride ion and one insert cylinder (276 cc) containing $4.3{\mu}Ci/cc$. GE $Advance^{TM}$ PET scanner and Ge-68 rotating pin sources for transmission scanning were used for this investigation. Post-injection transmission scan and emission scan were peformed alternatively over time. The error in emission images corrected using post-infection transmission scan to emission images corrected transmission scan was 2.6% at the concentration of $1.0{\mu}Ci/cc$. No obvious differences in image quality and noise were apparent between the two images. The attenuation correction can be accomplished with post-injection transmission measurement using rotating pin sources and this method can significantly shorten the time between transmission and omission scans and thereby reduce the likelihood of patient motion and increase scanning throughput in PET.

  • PDF

Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

Comparison of Flavor Characteristics and Palatability of Beef Obtained from Various Breeds (품종별 쇠고기의 풍미특성과 기호성 비교)

  • Park, Hyung-Il;Lee, Moo-Ha;Chung, Myung-Sub
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.500-506
    • /
    • 1994
  • For comparison of beef quality, four kinds of beef (Korean native cattle beef, dairy cattle beef, imported beef, cross-bred beef) were investigated through tenderness, juiciness and flavor related components measurement and organoleptic tests. Flavor related chemical components such as NPN, IMP, free fatty acid and free amino acids were analyzed, water holding capacity, contents of hydroxyproline and intramuscular fat were measured for evaluation of beef tenderness. Instron was also used for measuring beef tenderness as an objective method. Triangle test and descriptive analysis test were conducted for comparison and evaluation of preference of various beef samples. In hardness analysis using Instron, imported and cross-bred beefs had higher value than that of Korean native cattle or dairy cattle beef. Water holding capacity and pH of Korean cattle beef was higher than that of others. The intramuscular fat content of Korean cattle beef was highest, so it was expected juicier than other beef. In flavor related compound analysis, NPN content of Korean native cattle beef was the lowest, which shows it spent the least time among sample meats after slaughter. IMP, hypoxantine and inosine were most abundant in Korean native cattle beef. In free amino acids analysis showed that the proportion of basic acid and aromatic acid content of Korean native cattle beef was highest, whereas that of sulfur containing amino acid of imported beef was highest. TBA value of Korean native cattle beef was the lowest, and analysis of fatty acid composition revealed that the proportion of unsaturated fatty acid of Korean native cattle beef was higher than imported and dairy cattle beef, but similar to cross-bred beef. Organoleptic test was performed by triangle test and descriptive analysis. In triangle test, most panelist could distinguish Korea native cattle beef from imported beef and cross-bred beef, imported beef from cross-bred beef. In descriptive analysis which relys on subjective standards of panelists, there was no difference among beef in aroma, flavor and tenderness except juiciness. Even though contents of non volatile flavor compounds in Korean native cattle beef were higher than those of other beef samples, there were no significant differences in subjective panel test. The results showed that Korean consumers do not have common standards for beef quality evaluation.

  • PDF

Uptake Patterns of N and P by Reeds (Phragmites australis) of Newly Constructed Shihwa Tidal Freshwater Marshes (시화지구 인공습지에서 갈대에 의한 질소 및 인 흡수)

  • 노희명;최우정;이은주;윤석인;최영대
    • The Korean Journal of Ecology
    • /
    • v.25 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • This study was conducted to examine the seasonal pattern of N and P uptake by reeds (Phragmites australis) planted in newly constructed Shihwa tidal freshwater marshes. Reed and soil samples were collected from the wetland periodically from June 2000 to May 2002. Reed samples were analyzed for dry weight and content of N and P Soil organic matter content and salinity were also determined. Dry matter content of reed increased during the growing season but decreased in the fall and winter. However, this seasonal pattern was not so evident in the second year. In particular, throughout the measurement period, dry matter content of reed was lowest at a site showing high soil salinity. Regression analyses between dry matter content of reed and soil EC(1:5) suggested that dry matter content per unit square meter would decrease by 1.5 kg with every 1 dS m/sup -1/ increase in soil EC(1:5). The amount of N and P assimilated by reed significantly decreased from the fall and was lowest in the spring. Net decrease in N content from reed during the fall and next spring was calculated as 34.5 and 24.6 g m/sup -2/ in the first and second years, respectively, while the corresponding P loss was 4.0 and 1.8 g m/sup -2/. Soil organic mailer content increased in the fall and winter, but decreased in the spring and summer. The results of this study suggested that the removal of N and P by reed would be considerable during the growing season but the nutrients taken up by reeds would return as detritus to the marshes in the fall and winter. Based on the results of the study, therefore, the harvest of the reed at the latter part of the growth would be recommended to prevent further water quality degradation. However, the long-term effects of reed harvest needs further study.

A Study on Developing the Draft of International Standard for the Determination of Perchlorate in Soil Using Ion Chromatography (이온크로마토그래피를 이용한 토양 중 퍼클로레이트 정량에 관한 국제표준(안) 연구)

  • Choi, Cheon-il;Lee, Goon-taek;Park, Min-ki;Jeong, Moon-ju;Kim, Ji-yang;Kang, Ji-young;Ryu, Ji-young
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.6
    • /
    • pp.55-61
    • /
    • 2015
  • Based on the literature study for the determination of perchlorate in soil we chose the ion chromatography as a measurement method and decided to use 70 mM KOH as an eluent to avoid the interference derived from the co-elution of pyrophosphate (P2O74−), tripolyphosphate (P3O105−). Also we proposed to use air dried soil through 0.15 mm sieve and distilled water as an extractant. Under the these basic concepts, we carried out the experiments to set up the detail procedure like solid to liquid ratio (S/L ratio), extraction time, device for extraction and indicating factors for quality control (e.g. precision, accuracy, MDL, LOQ). In case of time and device for extraction, 5 hours of mechanical shaking or 1 hour of centrifugation showed better precision and accuracy than that of sonication for 1 hour According to these results, we proposed the extraction method combining 5 hours of mechanical shaking with 1 hour of centrifugation. From the aspect of S/L ratio, the ratio of 1/2 or 1/3 showed resonable precision and accuracy. In case of the ratio of 1/2, there would be some problems in the separation process when the proportion of fine particle is high. Therefore, we proposed the extraction ratio of solid to liquid as 1/3 instead of 1/2. With the consideration of cost effectiveness and soil salinity, we proposed the use of cartridge for removing the interfering anions like chloride, sulfate and carbonate in specific sample such as saline soil.