• Title/Summary/Keyword: Water Quality Measurement

Search Result 533, Processing Time 0.03 seconds

A Study on Hardened Properties and Durability of Concrete according to Unit-Water Content (배합수량 변동에 따른 콘크리트의 경화성상 및 내구성에 관한 연구)

  • Koo, Kyung-Mo;Lim, Chang-Hyuck;Lee, Eui-Bae;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.45-48
    • /
    • 2009
  • The performance of concrete mainly depend upon its water-cement ratio. If water percentage is excess in concrete, it may cause the degradation of performance. Because of these reasons, the change of water content is managed by using various evaluation method of unit water content. And criterion for the change of water content is regulated and used. However the criterion is set only considering production error and measurement error but criterion does not consider performance degradation of concrete. Therefore this study tries to investigate degradation of performance while adding extra water by artificial manipulation or management error in concrete, The contents of extra water for tests are set as 0, 20, 40, 60kg/m3, to examine the performance degradation of concrete, strength, shrinkage, cracks, carbonation are tested This study conclude that, when extra water content is excess than 20kg/m3 in concrete, then performance level of concrete declined rapidly. 80 it is very important to maintain quality of concrete for its better performance.

  • PDF

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

Quality assessment of high performance concrete using digitized image elements

  • Peng, Sheng-Szu;Wang, Edward H.;Wang, Her-Yung;Chou, Yu-Te
    • Computers and Concrete
    • /
    • v.10 no.4
    • /
    • pp.409-417
    • /
    • 2012
  • The quality of high performance concrete largely depends on water cement ratio, porosity, material composition and mix methods. The uniformity of color, texture and compressive strengths are quality indicators commonly used to assess the overall characteristics of concrete mixes. The homogeneity and share of coarse aggregates play a key role in concrete quality and must be analyzed in a microscopic point of view. This research studies the quality of high performance concrete by taking drilled cores in both horizontal and vertical directions from a 1.0 $m^3$ specimen. The coarse aggregate, expressed in digitized $100{\times}116$ dpi resolution images are processed based on brightness in colors through commercial software converted into text files. With the image converting to text format, the share of coarse aggregate is quantified leading to a satisfactory assessment of homogeneity - a quality index of high performance concrete. The compressive strengths of concrete and the shares of coarse aggregate of the samples are also compared in this research study to illustrate its correlation in concrete quality. It is concluded that a higher homogeneity of aggregate exists in the vertical plane than that of the horizontal planes of the high performance concrete. In addition, the concrete specimen showing denser particle packing has relatively higher compressive strengths. The research methodology provides an easy-to-use, direct measurement of high performance concrete when conducting quality assessment in the construction site.

Effect of Cooking Condition on the Eating Quality of Cooked Brown Rice (취반조건이 현미밥의 식미특성에 미치는 영향)

  • 김경애;정난희;전은례
    • Korean journal of food and cookery science
    • /
    • v.11 no.5
    • /
    • pp.527-535
    • /
    • 1995
  • The sensory and instrumental characteristics of different water to brown rice ratio with pressure and electric cookers were examined. The result of sensory evaluation revealed more significant differences in most of taste, texture, appearance, overall eating quality. The difference of sensory characteristics according to the types of cookers and the difference water to brown rice ratio showed the highest preference nonwaxy brown rice 1.4 and waxy brown rice with pressure cooker The instrumental measurement of cooked brown rice using instron showed that the difference between different water to brown rice ratio and pressure cooker. Especially hardness in instrumental characteristics revealed highly significant difference.

  • PDF

Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp (HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구)

  • Dong Hyuk Jeong;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

Scientific Study for the Starndardization of the Preparation Methods for Kyongdan (III) -for the focus on the volume of water and temperature of adding water- (경단 조리법의 표준화를 위한 조리과학적 연구(III) -첨가하는 물의 양과 물의 온도를 중심으로-)

  • 김기숙;한경선
    • Korean journal of food and cookery science
    • /
    • v.8 no.4
    • /
    • pp.405-410
    • /
    • 1992
  • This study attempted to examine the effects on sensory characteristics and texture of Kyongdan in various volume of adding water and temperature of adding water. Evaluation was conducted through sensory evalation and objective evaluation. The results were summarised as follows. 1. In sensory evaluation on various volume of water and temperature of adding water, the most favorite tendency on the quality was at the 25% adding water and hot water ($80^{\circ}C$). 2. This condition corresponded to the low level of hardness, adhesiveness and the high level of springiness and cohesiveness, chewiness in comparison with Instron measurement.

  • PDF

Comparison of the Accuracy of Velocity Measurement Using LSPIV (LSPIV를 이용한 유속측정 정확도 비교)

  • Hwang Eui-Ho;Yang Jae-Rheen;Koh Deuk-Koo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1512-1517
    • /
    • 2005
  • Soil particles from rainfall flow into reservoir and give lots of influence in water quality because the Even though techniques related with computer and communications are growing rapidly, it is true that efforts for hydrological survey and the management of its results have not been made enough to make use of the state-of-the-art technologies. Among the water-related techniques, measurement of river discharge is the most important one because these data are basic to almost every field of the hydrological science. In this research, a large-scale particle image velocimetry (LSPIV) unit has been designed and constructed to measure river discharge effectively In field conditions. Measured data using this unit is compared with the results recorded by the microwave water surface current meter (MWSCM) at the same location. The purpose of this research is to propagate the feasibility of using the MWSCM for river discharge velocimetry.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content of High Strength Concrete by Frequency Domain Reflectometry Sensor (고주파수분센서를 통한 고강도 콘크리트 단위수량 평가에 관한 실험적 연구)

  • Youn, Ji-Won;Lee, Seung-Yeop;Yu, Seung-Hwan;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.173-174
    • /
    • 2023
  • In this study, unit-water content was measured using a frequency domain reflecometry(FDR) sensor that complements the problems of the existing unit-water content measurement method to evaluate the unit-water content affecting the workability, durability, and quality of high strength concrete. The experiment used the unit-water content of high strength concrete as a variable, and the accuracy and probability distribution of the unit-water content measured through deep learning were analyzed for the output value output through the FDR sensor. In the case of the unit-water content predicted by deep learning analysis, a high accuracy and high distribution of more than 93% were found within the error range of ± 10 kg/m3. In the future, research is needed to secure high reliability by utilizing data obtained through experiments with various variables.

  • PDF

THE RELATION BETWEEN QUALITY AND CONTENT OF ZINC AND MAGNESIUM IN DRIED LAVER, PORPHYRA TENERA KJELLMAN (건해태(김)의 아연 및 마그네숨 함양과 품질과의 관계)

  • LEE Jong-Ho;HAN Sung-Bin;LEE Kang-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.7 no.2
    • /
    • pp.63-68
    • /
    • 1974
  • The growth of sea weeds is greatly affected by the environmental conditions of ambient water. Especially nutrient salts in sea water function as a major factor to the growth of lavers, so that the content of inorganic substances in lavers could he a criterion for quality evaluation of lavers. In this experiment, the relation between the quality and the content of Zinc and Magnesium which are not only physiologically active and closely related with pigments such as chlorophll and phycobilins but also important in quantify is discussed if such a measurement to be an index for quality evaluation. Sixteen samples of layers were collected from three different culture farms, 7 from Jangrim-Busan, 6 from Wando-Jeon Nam, 3 from Hadong-Gyeong Nam, and classified into 3 quality grades to each farm and to whole samples by organoleptic test. Zinc and Magnesium were analyzed by atomic absorption spectrophotometry. For pigment analysis, chlorphyll was extracted with 85 percent acetone, filtered and the absorbance was measured at 660 nm and the residue was further extracted with phosphoric buffer solution to determine the optical density for phycobilins at 560 nm. The result showed that the total content of Zinc and Magnesium varied between the farms, but kept consistent with quality grades from the same farm. The Zinc content was correlated proportion- ally with the content of phycobilins, and Magnesium content in total ash could roughly represent the content of chlorophll except some examples in which the Magnesium content of chlorophyll-ext ractresiduewasexceptionallyhigher. In conclusion the contents of these metals provide an applicable index for quality judgment of lavers.

  • PDF

Development of Dual-Window Phantom for Output Measurement of Medical Linacs (의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발)

  • Jeong, Dong Hyeok;Kwak, Dong Won;Moon, Young Min;Kang, Yeong-Rok;Kim, Jeung Kee;Lee, Man Woo
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.229-233
    • /
    • 2012
  • A small water phantom (dual-window phantom) was developed to improve the output measurement efficiency of medical linacs. This phantom is suitable for determining the quality index and output dose for high-energy photon beams. The phantom has two opposite windows and two independently rotating axes. The two axes measure the tissue phantom ratio (TPR) and the percentage depth dose (PDD) simply without requiring chamber movement by rotating the phantom around its axis. High-energy photon beams from a Co-60 irradiator and a medical linac were used to evaluate the phantom. The measured quality index is in good agreement with the reference values; the measured and reference values are within 0.2% of each other for the Co-60 gamma rays and within 1.4% for 6 and 10 MV X-rays. This phantom is more practical for routine output measurements, resulting in the prevention of potential human errors.