• Title/Summary/Keyword: Water Purifier

Search Result 89, Processing Time 0.027 seconds

소규모 고도 수처리 기술 -가정용 정수시스템 중심으로-

  • Sung, Kyung-Hak;Cho, Bong-Yeon;Park, Ho-Wan
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.06a
    • /
    • pp.207-231
    • /
    • 1997
  • The use household water purifier is continuously increasing due to the distrust of the piped, rap water, which may be caused by the deterioration of water quality and water supply facilities in Korea. The water purifier distributing in the domestic market is the membrane type that composes of membrane as a basic filter, sediment filter as a prefilter and activated carbon filter instead of one purifying water system. The membrane type using as a water cleaning system is mainly the method of micro filtration(NIF) as well as ultra filtration(UF) and reverse osmosis(RO). The types of MF and UF are using to remove suspended solids and virus, and RO is using to remove ionic compound in chemical organic compounds. At the beginning the household water purifier was imported as end-product or assembled by only importing module from small businesses in Korea. Therefore, people was hard to confide in the product quality because the sales policy and management of water purifier by small business were not effectively organized. However, the defects of water purifier having up to now ate improving by the efforts of special branches of water purifier and large enterprises, and new great products are developing and producing. To develop the best quality product of water purifier in Korea, it should be considered seasonal water characteristrics rather than any other condition. For example, the water purifier can be affected by the water temperature change, increase of suspended solids in the rainy season and inflow of raw water having concentration in a dry season. The subject we have to investigate in the future is to develop the water purifying system adaptable in Korea which can treat the water quality using close analyses of local and seasonal water characteristics.

  • PDF

A Study on Current Status and Trends of Recycling Used Water Purifier Filters (가정용 정수기 폐필터 재활용 동향에 관한 연구)

  • Shin, Yu Jeong;Kim, Young In;Kim, Jung Gun;Yeom, Seong Il;Lee, Do Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.5
    • /
    • pp.398-404
    • /
    • 2021
  • The use of water purifiers has been increasing every year due to increased drinking water safety concerns raised by the water pollution accidents occasionally reported. Currently, more than 10 million water purifiers have been distributed in Korea, and the estimation of the purifier sales reaches two million units per year. As a result, the number of used water purifier filters that must be replaced on a regular basis has gradually increased. However, regardless of the considerations for the capacity of used filters remaining, water purifier filters were replaced and collected at regular intervals. The high cost of disposal of the used filters by landfill or incineration were required. Thus, in this study, the current status and trends of recycling technologies for used water purifier filters were reviewed. It is noted that there was insufficient statistical data to understand the current status of the difference between the number of used water filters discarded and the number of those recycled. Most studies on the recycling of old water purifier filters have concentrated on pretreatment and cleaning methods for sediment filters and membrane filters, with the goal of extending the lifespan of used filters. Further, the study suggested future study directions on the recycling of used water purifier filters, which could be useful information on establishing environmental policy to promote the recycling of used filters.

The Control Realities of Water Purifier in Northern Part of Gyeonggi-do. (경기북부지역의 정수기물 관리실태 조사)

  • 박용배;손진석;강정복;방선재;김중범;최명순
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • There are lots of waterborne diseases which are caused by pathogenic microorganisms disseminated in contaminated environment. The purpose of this study is to investigate the status of water qualify and in order to investigate the sanitary condition of water purifier in northern part of Gyeonggi-do. We analyzed pathogenic microorganisms and 44 items of drinking water criteria from April to July in 2002. The results were as follows. 1. In 774 samples of water purifier, Pathogenic bacteria(salmonella, E coli O-157, O-26, O-111, shigella, pseudomonas etc.) were not isolated and total coliforms not detected. 2. About 76.5% of the water with purifier are found to be appropriated to the drinking water quality criteria. but 182 samples(23.5%) were without limits of drinking water criteria. 3. In the microbiological examination, 774 samples of purified water showed that 169 samples(21.9%) exceed the range of recommended limits(100 $CFU/m{\ell}$) to the total viable bacterial counts by pour plate method.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

A Sanitary Survey on the Clean Water by Domestic Purifier (가정용 정수기의 수질에 대한 위생학적 조사 소견)

  • 채용곤
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

Mechanism analysis through Water fire case (정수기 화재발생 사례를 통한 재현실험)

  • Lee, Jeong-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.593-618
    • /
    • 2011
  • Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.

  • PDF

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

Smart Water Purifier by Application Interworking (애플리케이션 연동을 통한 스마트 정수기)

  • Kim, Ji Woo;Lee, Seung Mok;Kim, Tae Hoon;Lee, Seung Ho;Woo, Young Woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.410-412
    • /
    • 2021
  • Recently, the amount of information and content has increased dramatically. Users can easily obtain recipe through various media. In addition, the water purifier market is growing without a downward trend and demand for more convenient and smart water purifiers are increasing. By using a smart water purifier with application, each individual can improve the quality of the dish by using a certain amount of water that each person prefers. A solenoid valve was used to allow only the amount of water set by individual to flow out and a solenoid valve and smartphones were linked using Bluetooth communication while using smartphone applications developed when setting the amount of water.

  • PDF

A Study on the matter of Disinfection in UV/TiO2 Water Treatment process (UV/TiO2 수처리 공정에서의 살균에 관한 연구)

  • Lee, Gyu-Hwan;Lee, Sang-Jin;Lee, Yong-Jae;Rhee, Dong-Seok
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.15-18
    • /
    • 2007
  • This study investigated disinfection effect by general water purifier and water purifier with UV light disinfection. The results are as follows : (i) The general bacteria existed plentifully in a storage tank before treatment (ii) Water treated in water purifier did not meet the water treatment regulation standard since the presence of bacteria, whereas with UV light application the regulation standard is totally satisfied. (iii) Photocatalytic disinfection process with UV light in the presence of $TiO_2$ more effectively killed general bacteria than UV light only.

  • PDF