• Title/Summary/Keyword: Water Meter

Search Result 636, Processing Time 0.035 seconds

Application of microwave water surface current meter for measuring agricultural water intake (농업용수 사용량 계측을 위한 전자파 표면유속계의 적용)

  • Baek, Jongseok;Kim, Chiyoung;Lee, Kisung;Kang, Hyunwoong;Song, Jaehyun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.12
    • /
    • pp.1071-1079
    • /
    • 2020
  • For integrated water management, it is essential to secure basic data such as the amount of agricultural water intake. The river water intake through the intake weir is carried out through the agricultural irrigation canal, and a method for measuring the quantity of water intake is required to suit the characteristics of the measuring points. In this study, the accuracy of the calculated flow data was determined by applying a microwave water surface current meter. The microwave water surface current meter is a method of calculating surface velocity using doppler effect, which is mainly used in high-velocities situations such as flood. Surface velocity is difficult to represent the average velocity of the entire section at low dicharges or high wind speeds, it is considered to be low in continuous utilization throughout the year, and it is necessary to verify whether the measurement using an microwave water surface curren meter is appropriate in agricultural irrigation canal. The data measured with an microwave water surface curren meter were compared with the actual flow data to calculate the intake data in agricultural irrigation canal. In agricultural irrigation canal, the low-level discharge calculated using an microwave water surface current meter at a minimum velocity of about 0.3 m/s and a minimum discharge of about 1.0 m3/s or higher was found to have a high tendency and accuracy compared to the standard discharge, especially when the high discharge was high. Although effective results can be obtained in terms of quantity at low discharge, it is deemed that subsequent studies are needed to calculate the average discharge of the cross section at low discharge, given that the trend of data is unstable. Through this study, it is suggested that it is appropriate to calculate the amount of water intake through the microwave water surface current meter in artificial waterways with a certain discharge or higher, so it is expected to be widely distributed as a method for measuring river water intake.

Rapid Quantification of Chloride in Tobacco Leaves by a Chloride Meter (Model: CL-2Z) (Chloride Meter(CL-2Z형)를 이용한 담배잎 중 chloride의 신속한 검정방법)

  • Lee, Mee-Kyoung;Jeong, Hun-Chae;Kim, Yong-Yeon;Yu, Yun-Hyun
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.28 no.2
    • /
    • pp.83-93
    • /
    • 2006
  • The aim of this study is to develop a simple and rapid field method for the determination of chloride content in tobacco green or cured leaves. To set up a practical process, several factors such as the proper sampling position of each leaf, the size of leaf lamina pieces for blending, the substitution of deionized water fur the extracting solution, 0.1N $HNO_3$, the submerging durations before blending, and the standing times before measuring were studied using flue-cured and burley tobacco with a stable and reproducible Chloride Meter, KRK CL-2Z. From the results, chloride contents of tobacco leaves could be analyzed with the Chloride Meter(CL-2Z) using the suspension of 14 mm diameter leaf disks after soaking in distilled water for 30 min., blending with a mini-blender for 30 seconds. The chloride contents measured in this way showed highly significant correlations with ones by the conventional potentiometric method using an ion meter-chloride electrode and $AgNO_3$ titration. In our method, the procedures such as drying, powdering and weighing samples, and using chemical reagents for extraction (0.1N $HNO_3$) and titration(0.028N $AgNO_3$) could be eliminated. These results suggest that the newly constructed method using the Chloride Meter is more efficient to determine the chloride content of tobacco leave in comparison with the one by the Ion $Meter:AgNO_3$ titration.

Development of Oil Content Meter for Oily Water Separator in Ship (선박 유수분리기용 유분검출기의 개발)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

Computational Fluid Dynamics of Hydraulic Valve Meter (밸브 수압측정기의 유동해석)

  • Lee, Jong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.1963-1968
    • /
    • 2012
  • In this research paper a hydraulic valve meter for the measurement of water pressure in fields was designed by using three dimensional automatic design program CATIA. And, also computational fluid dynamics was applied to the designed hydraulic valve meter in order to obtain flow distributions due to internal pressures. This analytical results will be provided as fundamental data in the development of new concepts of hydraulic valve meter and the hydraulic valve meter in development may reduce valve checking times and improve safety by preventing accidents earlier.

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

Development of an Integrated Meter Reading Home Concentrate Device (통합 원격검침 지시장치 개발)

  • Park, Jae-Sam
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • This paper highlights the home concentrate device(HCD) that integrates the data reading and display of the six types of meters (water, hot water, heating, cooling, gas and electricity) used in Korean residential areas. Unlike the conventional system which utilizes single MCU, the developed system uses two MCUs for one MCU to gather the meter readings and for the other MCU to communicate to the server computer. Hard ware design, communication protocols, LCD design and program structures are discussed and the test results are shown in this paper. With the implementation of integrated meter reading, the developed system can increase the popularity of automatic meter reading(AMR) with its better scalability, pricing, installation fee, maintenance and faster response.

Delineation of water seepage in a reservoir embankment from ground temperature measurements (지온탐사에 의한 저수지 제방의 누수 조사)

  • 박삼규
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

수도미터의 측정과 요금청구방법, 물 사용과 절수

  • Korea Water and Wastewater Works Association
    • 수도
    • /
    • s.26
    • /
    • pp.26-28
    • /
    • 1981
  • 이 글은 국제수도협회(IWSA) 주최 국제수도회의 수도미터 및 계량상임위원회(International standing comittee on water meter and water metering)에서 벨기에의 A. Desmed가 발표한 내용을 번역 게재한다.

  • PDF

Design of a Remote Meter Reading module considering battery life time (배터리 수명을 고려한 원격검침 모듈 설계)

  • Jeong, Won-Chang;Gu, Myeong-Mo;Jang, Sung-Joo;Kim, Sang-Bok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.45-50
    • /
    • 2008
  • Meter reading modules, which read the meter and transmit the data to water management offices, can't use the electric wires for their power supply. Therefore, batteries have to be used for meter reading modules and that cause maintenance problems like periodic batteries replacement. To save the maintenance cost, a wireless transmitting solution with less power consumption is required. In This paper, we designed a remote meter reading module, which reads meter automatically with less power consumption of battery by effective management of power source and transmits the reading data using RF.

  • PDF