• Title/Summary/Keyword: Water Mass Flux

Search Result 257, Processing Time 0.026 seconds

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger (알루미늄 다채널 평판관 증발기 내 냉매분배)

  • Kim Nae-Hyun;Park Tae-Gyun;Han Sung-Pil;Lee Eung-Ryul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.800-810
    • /
    • 2006
  • The R-134a flow distribution is experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous air-water results. The flow at the header inlet is stratified. For the downward flow configuration, the liquid distribution improves as the protrusion depth or the mass flux increases, or the quality decreases. For the upward configuration, the liquid distribution improves as the mass flux or quality decreases. The protrusion depth has minimal effect. For the downward configuration. the effect of quality on liquid distribution is significantly affected by the flow regime at the header inlet. For the stratified inlet flow, the liquid is forced to rear part of the header as the quality decreases. However, for the annular inlet flow, the liquid was forced to the frontal part of the header as the quality decreased. For the upward flow, the effect of the mass flux or quality on liquid distribution of the stratified inlet flow is opposite to that of the annular inlet flow. The high gas velocity of the annular flow may be responsible for the trend. Generally, the liquid distribution of the stratified inlet flow is better than that of the annular inlet flow. Possible explanation is provided from the flow visualization results.

Seasonal Variations of Particle Fluxes in the Bransfield Strait, Antarctica (남극 브랜스필드 해협에서 입자 플럭스 계절변화)

  • Kim, Dong-Seon;Kim, Dong-Yup;Kim, Young-June;Kang, Young-Chul
    • Ocean and Polar Research
    • /
    • v.24 no.2
    • /
    • pp.153-166
    • /
    • 2002
  • Particle fluxes were measured by using time-series sediment traps in the Bransfield Strait from December 27th, 1999 to December 26th, 2000. Total mass fluxes showed distinct seasonal variations with high fluxes in the austral summer and low fluxes in the austral winter at a 678m water depth in the eastern Bransfield Strait, while they were high only in January and fairly low in other months at a 960m water depth in the central Bransfield Strait. The reason that total mass fluxes occurred only in January at a 960m water depth in the central Bransfield Strait seems to be the strong current in the surface waters, which leads to a substantial amount of terrestrial materials and locally produced organic matter being advected away from the mooring site. Total mass fluxes were very high from January to October at a 1678m water depth in the eastern Bransfield Strait, while they were high only in January and February at a 1860m water depth in the central Bransfield Strait. The fact that total mass fluxes were higher at the deep water in the both sites than at the intermediate water depth may reflect that a substantial amount of terrestrial and organic materials are laterally transported by strong tidal current from the shallow environments to the deep basins.

Technique for Estimating $CO_2$ and $H_2O$ Exchange between the Atmosphere and the Biosphere : Eddy Covariance Method (광합성과 증발산의 미기상학적 측정기술)

  • Wonsik Kim
    • Proceedings of The Korean Society of Agricultural and Forest Meteorology Conference
    • /
    • 2003.09a
    • /
    • pp.115-128
    • /
    • 2003
  • o What is the flux \ulcorner Flux is the transfer of a quantity per unit area per unit time. The quantities are mass, heat, moisture, momentum and pollutant in micrometeorology. Kinematic flux (Fluid). The reduction in wind speed due to frictional drag transfers momentum from the atmosphere to the surface, creating turbulence that mixes the air and transports heat and water from the surface into the lower atmosphere. (omitted)

  • PDF

Experimental Study and Correlation Development of Critical Heat Flux under Low Pressure and Low Flow Condition

  • Kim, Hong-Chae;Baek, Won-Pil;Kim, Han-Kon;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.356-361
    • /
    • 1997
  • To investigate parametric effect on CHF and to get CHF data, experimental study has been performed with vertical round tubes under the condition of low pressure and low flow (LPLF). Test sections are made of Inconel-625 tube and have the geometry of 8 and 10 mm in diameter, and 0.5 and 1.0 m in heated length. All experiments have been conducted at the pressure of under 9 bar, the mass flux of under 250 kg/$m^2$ and the inlet subcooling of 350 and 450 kJ/kg, for stable upward flow with water as a coolant. Flow regime analysis has been performed for obtained CHF data with Mishima's flow regime map, which reveals that most of the CHF occur in the annular-mist flow regime. General parametric trends of the collected CHF data are consistent with those of previous studies. However, for the pressure effect on CHF, two different are observed; For relatively high mass flux, CHF increases with pressure and far lower mass flux, CHF decrease with pressure. Using modern data regression tool, ACE algorithm, two new CHF correlations for LPLF condition are developed based on local condition and inlet condition, respectively. The developed CHF correlations show better prediction accuracy compared with existing CHF prediction methods.

  • PDF

Flow Condensation Heat Transfer Coefficients of Pure Refrigerants (순수냉매의 흐름응축 열전달계수)

  • 김신종;송길홍;정동수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.175-183
    • /
    • 2002
  • Flow Condensation heat transfer coefficients (HTCs) of Rl2, R22, R32, Rl23, Rl25, R134a, R142b were measured experimentally on a horizontal plain tube. The experi- mental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water-glycol loop. The test section in a refrigerant loop was made of a copper tube of 8.8 mm inner diameter and 1000 mm length respectively. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. All tests were performed at a filed refrigerant saturation temperature of 4$0^{\circ}C$ with mass fluxes of 100, 200, 300 kg/$m^2$s. The experimental result showed that flow condensation HTCs increase as the quality, mass flux, and latent heat of condensation increase. At the same mass flux, the HTCs of R32 and R142b were higher than those of R22 by 35~45% and 7~14% respectively while HTCs of R134a and Rl23 were similar to those of R22. On the other hand, HTCs of Rl25 and Rl2 were lower than those of R22 by 28 ~30% and 15 ~25% respectively Finally, a new correlation for flow condensation HTCs was developed by modifying Dobson and Chato's correlation with the latent heat of condensation considered. The correlaton showed an average deviation of 13.1% for all pure fluids data indicating an excellent agreement.

Dialysis with ultrafiltration through countercurrently parallel-flow membrane modules

  • Yeh, Ho-Ming;Chen, Chien-Yu
    • Membrane and Water Treatment
    • /
    • v.4 no.3
    • /
    • pp.191-202
    • /
    • 2013
  • The application of ultrafiltration operation to the dialysis in countercurrently parallel-flow rectangular membrane modules was investigated. The assumption of uniform ultrafiltration flux was made for operation with slight concentration polarization and declination of transmembrane pressure. Considerable improvement in mass transfer is achievable if the operation of ultrafiltration is applied, especially for the system with low mass transfer coefficient. The enhancement in separation efficiency is significantly increased with increasing ultrafiltration flux, as well as with increasing the volumetric flow rates. Furthermore, increasing the volumetric flow rate in retentate phase is more beneficial to mass transfer than increasing in dialysate phase.

A Numerical Model for Heat and Mass Transfer Processes within a Vertical Tube GAX Absorber (수직원관형 GAX 흡수기 내부의 열 및 물질전달과정에 대한 수치모델)

  • 천태식;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.102-111
    • /
    • 2000
  • A numerical model which simulates the simultaneous heat and mass transfer within a vertical tube GAX absorber was developed. The ammonia vapor and the solution liquid are in counter-current flow, and the hydronic fluid flows counter to the solution liquid. The film thickness and the velocity distribution of the liquid film were obtained by matching the shear stress at the liquid-vapor interface. Two-dimensional diffusion and energy equations were solved in the liquid film to give the temperature and concentration, and a modified Colburn-Drew analysis was used for the vapor phase to determine the heat and mass fluxes at the liquid-vapor interface. The model was applied to a GAX absorber to investigate the absorption rates, temperature and concentration profiles, and mass flow rates of liquid and vapor phases. It was shown that the mass flux of water was negligible compared with that of ammonia except the region near the liquid inlet. Ammonia absorption rate increases rapidly near the liquid inlet and decrease slowly. Both the absorption rate of ammonia vapor and the desorption rate of water near the liquid inlet increase as the vapor mass flow rate increases, but the mass fluxes of the ammonia and the water near the liquid outlet decrease as the mass flow rate of the vapor increases.

  • PDF

Derivation of Mechanistic Critical Heat Flux Model and Correlation for Water Based on Flow Excursion

  • Chang, Soon-Heung;Kim, Yun-Il;Baek, Won-Pil
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.349-355
    • /
    • 1996
  • In this study, the mechanistic critical heat flux (CHF) model and correlation for water are derived based on flow excursion (or Ledinegg instability) criterion and the simplified two-phase homogeneous model. The relationship between CHF for the water and the principal parameters such as mass flux heat of vaporization, heated length-to-diameter ratio, vapor-liquid density ratio and inlet subcooling is derived on the developed correlation. The developed CHF correlation predicts very well at the applicable ranges, 1 < P < 40 bar, 1, 300 < G 27, 00 kg/$m^2$s and inlet quality is less than -0.1. The overall mean ratio of predicted to experimental CHF value is 0.988 with standard deviation of 0.046.

  • PDF

Simulation of transport phenomena in porous membrane evaporators using computational fluid dynamics

  • Mohammadi, Mehrnoush;Marjani, Azam;Asadollahzadeh, Mehdi;Hemmati, Alireza;Kazemi, Seyyed Masoud
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.87-100
    • /
    • 2016
  • A numerical simulation of membrane evaporation process was carried out in this work. The aim of simulation is to describe transport of water through porous membranes applicable to the concentration of aqueous solutions. A three-dimensional mathematical model was developed which considers transport phenomena including mass, heat, and momentum transfer in membrane evaporation process. The equations of model were then solved numerically using finite element method. The results of simulation in terms of evaporation flux were compared with experimental data, and confirmed the accuracy of model. Moreover, profile of pressure, concentration, and heat flux were obtained and analyzed. The results revealed that developed 3D model is capable of predicting performance of membrane evaporators in concentration of aqueous solutions.

Boiling Heat Transfer Characteristics of Deionized Water in Microchannel (마이크로 채널에서 물의 비등 열전달 특성)

  • Lim, Tae-Woo;You, Sam-Sang;Choi, Hyeung-Sik;Kim, Dong-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.750-756
    • /
    • 2011
  • An experimental study was carried out to measure the heat transfer coefficient in flow boiling to deionized water in a microchannel having a hydraulic diameter of $500{\mu}m$. Tests were performed in the ranges of heat fluxes from 100 to 400 kW/$m^2$, vapor qualities from 0 to 0.2 and mass fluxes of 200, 400 and 600 kg/$m^2s$. From the experimental results, it is found that the measured heat transfer coefficients is independent of mass flux and quality, and is somewhat dependent of heat flux. Measured data of heat transfer are compared to a few available correlations proposed for macroscale. The previous correlations for macroscale overpredicted the flow boiling heat transfer coefficient for the test conditions considered in this work.