• Title/Summary/Keyword: Water Level Meter

Search Result 96, Processing Time 0.028 seconds

Development of High Precision Underground Water Level Meter Using a Buoyant Rod Load Cell Technique (부력 추를 이용한 지하수위 측정용 센서 개발)

  • Lee Bu-Yong;Park Byoung-Yoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.36-40
    • /
    • 1999
  • A new method was developed to measure underground water level with high reliability. The principle of new method was to detect a change of a buoyant force according to change in water level of underground water measured by the use of a straingage load cell. Field test of the instrument was carried out in Cheju Island. The results were as follows; 1) The present study provided a possibility to develop a new underground water level meter. 2) This new instrument accomplished high reliability at field test in Cheju Island. 3) There is possibility of development of water level meter which measure various range of water level to detect a weight change of a buoyant forcd.

  • PDF

Mathematical Model Expression of Portable Calibration System for Float Type Water Level Meters (부자식 수위계를 위한 이동형 교정시스템의 수학 모델)

  • Hong, Sung-taek;Shin, Gang-wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1964-1972
    • /
    • 2017
  • K-water have been operating as an International accredited calibration organization for ISO 17025 regarding float, ultrasonic and radar type since 2008. Due to the absence of on-site calibration system, water level meter could only be calibrated from a laboratory. Therefore K-water institute developed an mobile calibration system for water-level meter in 2015 to calibrate the water-level meter on site. The mobile calibration system was certificated by KOLAS(Korea Laboratory Accreditation Scheme) in 2016. In this paper a mobile calibration system, which is a method to calibrate float type water level meter on site, is established. A mathematical equation was derived by reviewing characteristics of standard equipment and measurement. By developing the mobile calibration system, it is possible to achieve reliability of data through scientific system operation on hydrological data.

Development of Float Water Level Meter Portable Calibration System (부자식 수위계 이동형 교정시스템 개발)

  • Hong, Sung-taek;Kim, Il-han;Choi, Jong-woong;Shin, Gang-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.411-414
    • /
    • 2016
  • K-water institute is a calibration and test institute accredited by international standard calibration center for water-level meters. Due to the absence of on-site calibration system and procedure for Float Water Level Meter, the calibration was performed only in the standard calibration laboratory. In this study, mobile calibration system and procedure were developed to calibrate Float Water Level Meter on site using scale bar and camera. It is possible to obtain reliable water-level data and achieve consistent data management.

  • PDF

Open-channel discharges evaluation by the application of smart sensors

  • Khatatbeh, Arwa;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.138-138
    • /
    • 2022
  • Understanding a stream's or river's discharge is essential for a variety of hydrological and geomorphological applications at various sizes. However, depending on the stream environment and flow conditions, it is crucial to use the appropriate techniques and instruments. This will ensure that discharge estimations are as reliable as possible. This study presents developed smart system for continuous measurement of open channel discharge and evaluate streamflow measurement over various techniques. This includes developed smart flow meter as flow point measurements, smart water level sensor (installed on Hydraulic Structure ? Weir) and current meters. Advantages and disadvantages of each equipment are presented to ensure that the most appropriate method can be selected. we found that smart water level sensor is more prominent once used during flood event as compared to smart flow meter and current meters, while current meters seems to show better accuracy once applied for open channel.

  • PDF

Operation of Experimental Basin(Yi-dong Basin) (시험유역운영(이동유역))

  • 박재홍;김진택;박지환
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2003.05b
    • /
    • pp.611-614
    • /
    • 2003
  • Yi-dong experimental basin is operated for research on the rural basin characteristics and accumulation of a long term data by hydrological observation equipments. It is basin area 9,440ha, length 14.4km and slope 0.67%. Hydrological observation network is constructed of rainfall meter 4points, reservoir storage level 3points and river water level 2points.

  • PDF

Development of Oil Content Meter for Oily Water Separator in Ship (선박 유수분리기용 유분검출기의 개발)

  • 황정웅;정병건;김창화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.338-344
    • /
    • 2001
  • According to the MARPOL 73/78 of Convention, all ships should have oil filtering equipment and 15 ppm bilge which satisfy Requirements of MARPOL 73/78. This study is concerned with designing and manufacturing a prototype Oil content Meter(OCM) used in machinery area of ship. The prototype OCM is composed of two parts which are oil content sensing module and data processing unit. The oil content sensing module consists of infra-red light source, photo-diode light receivers, and a glass tube for bilge water sample. The data processing unit has a micro-processor as hard core and peripheral devices. The experimental results of prototype OCM and analysis of collected data reveal linear property between transmitted light and scattered light as long as the bilge water has low level content of oil. And this linear property leads to a oil content detecting method which is programmed and loaded into the data processing unit. The performance of the prototype OCM is compared with that of the commercial OCM in the market.

  • PDF

Delineation of water seepage in a reservoir embankment from ground temperature measurements (지온탐사에 의한 저수지 제방의 누수 조사)

  • 박삼규
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

Development of Inquiry-based Water Environmental Education Program using DO Meter - Measuring Activity of Dissolved Oxygen - (DO 미터를 이용한 탐구중심 물 환경교육 프로그램 개발 - 용존산소 측정 활동 -)

  • Lyu Jai-Hong;Lee Du-Gon
    • Hwankyungkyoyuk
    • /
    • v.19 no.2 s.30
    • /
    • pp.96-107
    • /
    • 2006
  • Inquiry has great value in environmental education(EE). Being able to see the world environmentally through 'inquiry-based environmental education' can be an important value and goal of EE. In this study, we intended to develop an EE program of measuring activity of dissolved oxygen(DO), based on the theory of 'inquiry-based EE'. Especially, we recognized the potential that DO meter can be used in 'inquiry-based EE', and we tried to develop a model of inquiry-based EE using DO meter. As a result of this research, we present specific models of inquiry-based EE about how to perform measuring activity of DO and how to use the DO meter in laboratories and streams from the perspective of inquiry of water environment. In the process of program development, we considered organization of the inquiry process, use of concept and knowledge, scientific inquiry and insightful inquiry, integration, sustain-ability, content components of 'Environmental Studies for EE', developmental level and in-forest of students. The developed EE model is a scientific inquiry model, pursuing 'explanation' based on data collection. Through this model, we tried to make students see water environment more deeply. The developed program can be applied to various water environments, like laboratories, streams, ponds, etc. It can be more effective inquiry activity if we perform measuring activities simultaneously with PH, electrical conductivity, and turbidity meters.

  • PDF