• 제목/요약/키워드: Water Leak Detection

검색결과 61건 처리시간 0.028초

음향방출 및 상관법을 이용한 상수도배관 누수탐지 연구 (Leak Detection of Waterworks Pipeline Using Acoustic Emission and Correlation Method)

  • 윤동진;정중채;이영섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.84-89
    • /
    • 2003
  • Water leak is one of topics with great concern in Korea and many other countries, because of decreasing water supplies and the deterioration of old pipeworks. Correlation techniques have been widely used in leak detection of water pipes, which allow to locate a leak point based on the correlation of leak noise at two sites along water pipes. In this study, both the cross-correlation method and the conventional arrival time difference method are applied in order to analyze and to locate a leak point of a water pipe. In experiment, a 150 m of whole length waterwork pipeline system was constructed in a ground, and several types of leak noise were installed on the pipeline in order to control leak condition. Both the cross-correlation technique and the arrival time difference method showed favorable results at leak detection with the experimental pipeline system.

  • PDF

배관-유체 연성진동을 이용한 누수지점 탐지알고리듬 개발연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Water)

  • Lee, Yeong-Seop;Yun, Dong-Jin
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.985-990
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

시간지연 추정을 통한 누수위치 식별 연구 (Time Delay Estimation for the Identification of Leak Location)

  • 이영섭;윤동진;김치엽
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.327-332
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. This sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than loom.

  • PDF

배관-유체 연성진동을 이용한 누수지점 탐지 알고리듬 개발 연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Fluid)

  • 이영섭;윤동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.798-803
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband sound from a leak location and this sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

센서네트워크를 이용한 무선 누수 탐지 시스템 (Wireless Water Leak Detection System Using Sensor Networks)

  • 최수환;엄두섭
    • 대한전자공학회논문지SP
    • /
    • 제48권3호
    • /
    • pp.125-131
    • /
    • 2011
  • 상수도 누수 탐지 시스템은 상수관로상의 누수 발생을 탐지하고 누수 위치를 추정하여 그 결과를 관제 서버로 알리는 시스템이다. 기존의 누수 탐지는 일반적으로 사용자가 직접 장비를 들고 이동하면서 누수 발생 탐지를 하는 방식으로 진행하기 때문에 작업 속도도 느리고 작업자의 경험에 많은 부분을 의존해야 한다. 또한 누수 탐지의 정확도를 높이기 위해서는 물 사용이 적은 심야시간에 탐지를 해야 하기 때문에 작업에 어려움이 따른다. 본 논문에서는 센서네트워크를 이용한 무선 누수 탐지 시스템을 제안하였다. 제안된 시스템에서 각 누수 탐지 장치는 무선 네트워크를 형성하여 탐지 결과를 주고받으며 이를 통하여 탐지의 신뢰성을 높였다. 또한 정확한 탐지를 위하여 상수도관의 수중음의 특성을 분석하고 누수음을 분리해내는 사전 신호처리 과정을 제안하였다. 마지막으로 누수 위치를 추정하기 위해서는 두 지점에 설치된 누수 탐지 장치의 시간 동기가 매우 중요한데 본 논문에서는 GPS에서 제공하는 1PPS(1 Pulse Per Second) 신호를 이용하여 정확한 시간 동기를 획득하였다. 본 시스템은 남양주시의 상수관로상에 적용하여 그 성능을 검증하였다.

파이프-유체의 연성진동을 이용한 누수위치 식별연구 (Pinpointing of Leakage Location Using Pipe-fluid Coupled Vibration)

  • 이영섭;윤동진
    • 한국소음진동공학회논문집
    • /
    • 제14권2호
    • /
    • pp.95-104
    • /
    • 2004
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, accelermeters aroused to detect leak locations which could provide an easier and more efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long and a 70m-long experimental pipeline systems are installed and the results with the systems show that the algorithm with the accelerometers offers accurate pinpointing for leaks location detection. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

Advantages of Acoustic Leak Detection System Development for KALIMER Steam Generators

  • Kim, Tae-Joon;Valery S. Yughay;Hwang, Sung-Tai;Chai, Jeong-Kyung;Choi, Jong-Hyeun
    • Nuclear Engineering and Technology
    • /
    • 제33권4호
    • /
    • pp.423-440
    • /
    • 2001
  • For sodium cooling liquid metal reactors during the last 25 years, it was most important to verify the safety of the steam generator, which absolutely requires a water leak detection system with fine sensitivity and response. This study describes the structure and leak classification of the HAMMER (Korea Advanced Liquid Metal Reactor) steam generator, compared with other classifications, and explains the effects of leak development. The requirements and experimental situations for the development of the KALIMER acoustic leak detection system (KADS) which detects micro leaks, not intermediate leaks, are introduced. We proposed four frequency bands, 1∼8kHz, 8∼20kHz, 20∼40kHz and 40∼200kHz, split effectively for analyzing the detected acoustic leak signals obtained from the sodium-water reaction model or water model in the mock-up system.

  • PDF

주입 압력파의 웨이블릿 일관성 분석을 사용한 저수조-관로-밸브 시스템에서의 누수탐지모형 연구 (A scheme of leak detection model in a reservoir pipeline valve system using wavelet coherence analysis of injected pressure wave)

  • 고동원;이정섭;김진원;김상현
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.15-25
    • /
    • 2021
  • In this study, a method of leakage detection was proposed to locate leak position for a reservoir pipeline valve system using wavelet coherence analysis for an injected pressure wave. An unsteady flow analyzer handled nonlinear valve maneuver and corresponding experimental result were compared. Time series of pressure head were analyzed through wavelet coherence analysis both for no leak and leak conditions. The leak information can be obtained through either time domain reflectometry or the difference in wavelet coherence level, which provide predictions in terms of leak location. The reconstructed pressure signal facilitates the identification of leak presence comparing with existing wavelet coherence analysis.

상수관망의 누수감지를 위한 주성분 분석의 적용 가능성에 대한 연구 (Study on the applicability of the principal component analysis for detecting leaks in water pipe networks)

  • 김기민;박수완
    • 상하수도학회지
    • /
    • 제33권2호
    • /
    • pp.159-167
    • /
    • 2019
  • In this paper the potential of the principal component analysis(PCA) technique for the application of detecting leaks in water pipe networks was evaluated. For this purpose the PCA was conducted to evaluate the relevance of the calculated outliers of a PCA model utilizing the recorded pipe flows and the recorded pipe leak incidents of a case study water distribution system. The PCA technique was enhanced by applying the computational algorithms developed in this study which were designed to extract a partial set of flow data from the original 24 hour flow data so that the effective outlier detection rate was maximized. The relevance of the calculated outliers of a PCA model and the recorded pipe leak incidents was analyzed. The developed algorithm may be applied in determining further leak detection field work for water distribution blocks that have more than 70% of the effective outlier detection rate. However, the analysis suggested that further development on the algorithm is needed to enhance the applicability of the PCA in detecting leaks by considering series of leak reports happening in a relatively short period.

가속도계를 이용한 상수도 배관의 누수위치 식별연구 (Pinpointing of Leakage Location of Water Pipelines using Accelerometers)

  • 이영섭;윤동진;정중채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.821-826
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of a good contermeasures of leaks Is to find and repair of leak points of pipes. Leak noise is a good source to identify the location of leak points of pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they were not so efficient tools beca. In this paper, two accelermeters are used to detect leak locations which could provide an easier and efficient method. The filtering, signal processing and algorithm is described for the detection of leak location. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the two accelerometers gives very accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed in underground pipes is also described.

  • PDF