• 제목/요약/키워드: Water Intake Tower

검색결과 32건 처리시간 0.025초

Dynamic behavior of intake tower considering hydrodynamic damping effect

  • Uddin, Md Ikram;Nahar, Tahmina Tasnim;Kim, Dookie;Kim, Kee-Dong
    • Structural Engineering and Mechanics
    • /
    • 제82권3호
    • /
    • pp.355-367
    • /
    • 2022
  • The effect of hydrodynamic damping on intake tower is twofold: one is fluid damping and another is structural damping. Fluid damping can be derived analytically from the governing equation of the fluid-structure-interaction (FSI) problem which yields a very complicated solution. To avoid the complexity of the FSI problem water-tower system can be simplified by considering water as added mass. However, in such a system a reconsideration of structural damping is required. This study investigates the effects of this damping on the dynamic response of the intake tower, where, apart from the "no water (NW)" condition, six other cases have been adopted depending on water height. Two different cross-sections of the tower are considered and also two different damping properties have been used for each case as well. Dynamic analysis has been carried out using horizontal ground motion as input. Finally, the result shows how hydrodynamic damping affects the dynamic behavior of an intake tower with the change of water height and cross-section. This research will help a designer to consider more conservative damping properties of intake tower which might vary depending on the shape of the tower and height of water.

선택취수 수심에 따른 취수탑 유입유동 특성 (Inflow Patterns Around a Water Intake Tower for Selective Withdrawal Depth)

  • 조용;김용열
    • 한국유체기계학회 논문집
    • /
    • 제13권6호
    • /
    • pp.63-70
    • /
    • 2010
  • Shallow water withdrawal systems have been replaced with a selected withdrawal system to keep stable raw water quality in spite of occurrence of algae and muddy inflow. Before reconstruction of the water intake tower in Yongdam reservoir supplying water to Gosan water treatment facility, we have predicted flow patterns of inflowing water into the water intake tower for various withdrawal conditions. It has been predicted that the water in the withdrawal layer is significantly inflowed from the front with fast velocity into the water intake tower irrespective of withdrawal depth, while the water away from the withdrawal layer is withdrawed a little from the side with slow velocity.

D댐의 취수탑 피뢰설비 구축방안 검토 (To examine the construction plan of the lightening rod equipment for the intake tower of D-dam)

  • 홍성택;이은춘;신강욱;이남영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.290-292
    • /
    • 2003
  • The intake tower of D-dam located in a mountainous area positioned in the left side of the dam and its structure installed alone on the water surface then, can become target of direct lightening. To protect the intake tower from the direct lightening and indirect-lightening, lightening rod installed in the top area of the intake tower and ground pole laid under the surrounding ground. however, because the surrounding ground almost consists of a rock, it is very difficult to obtain the grounding resistance. It is main object to examine the construction plan of the optimum lightening rod equipment and ground pole with measuring the earth specific resistance of the around of the intake tower which is the scheduled area to lay the ground pole with the Wenner's 4-electric pole method and the Schlumberger's method. and using the analysis tool, ESII.

  • PDF

Experimental study of dynamic interaction between group of intake towers and water

  • Wang, Haibo;Li, Deyu;Tang, Bihua
    • Earthquakes and Structures
    • /
    • 제6권2호
    • /
    • pp.163-179
    • /
    • 2014
  • Dynamic test with scaled model of a group of intake towers was performed to study the dynamic interaction between water and towers. The test model consists of intake tower or towers, massless foundation near the towers and part of water to simulate the dynamic interaction of tower-water-foundation system. Models with a single tower and 4 towers were tested to find the different influences of the water on the tower dynamic properties, seismic responses as well as dynamic water-tower interaction. It is found that the water has little influence on the resonant frequency in the direction perpendicular to flow due to the normal force transfer role of the water in the contraction joints between towers. By the same effect of the water, maximum accelerations in the same direction on 4 towers tend to close to each other as the water level increased from low to normal level. Moreover, the acceleration responses of the single tower model are larger than the group of towers model in both directions in general. Within 30m from the surface of water, hydrodynamic pressures were quite close for a single tower and group of towers model at two water levels. For points deeper than 30m, the pressures increased about 40 to 55% for the group of towers model than the single tower model at both water levels. In respect to the pressures at different towers, two mid towers experienced higher than two side towers, the deeper, the larger the difference. And the inside hydrodynamic pressures are more dependent on ground motions than the outside.

대청호 추동취수탑 부근의 수질변화 특성 (Variation of Water Quality around the Chudong Intake Tower in Daechung Reservoir)

  • 마심초;임봉수;허순욱;곽미애
    • 한국물환경학회지
    • /
    • 제31권6호
    • /
    • pp.637-643
    • /
    • 2015
  • This study has been carried out to provide the basic data obtained from the evaluation of the variation of water quality around the Chudong intake tower in Daechung resevoir, which may be able to help the establishment of a pure water supply policy. Five sites around the Chudong intake tower were selected, and the average data for recent ten years(from year 2004 to year 2013) were analysed. The average water quality around Chudong intake tower are as followed; pH 7.5, DO 8.7 mg/L, BOD 1.0 mg/L, COD 3.0 mg/L, SS 3.0 mg/L, TN 1.495 mg/L, TP 0.017 mg/L, and Chlorophyll-a 6.5 mg/m3 were matched the good class by comparing with the living environment standard of reservoir. COD values of higher than 3.0 mg/L after July were likely due to non-point pollutants and algae outbreak during rainy summer season. Total phosphorus rose sharply in the summer season, and then algae watch was issued consistently for average 40 days. Total nitrogen to total phosphorus ratio was average 90, and it is important to control the inflow phosphrous from small stream for proper management to block an algae growth according to eutrophication. It was recommended to operate the algae removing boats around intake tower from July to October, and was required advanced water treatment processes to remove NBD COD and bad odor and taste due to algae growth.

Seismic risk assessment of intake tower in Korea using updated fragility by Bayesian inference

  • Alam, Jahangir;Kim, Dookie;Choi, Byounghan
    • Structural Engineering and Mechanics
    • /
    • 제69권3호
    • /
    • pp.317-326
    • /
    • 2019
  • This research aims to assess the tight seismic risk curve of the intake tower at Geumgwang reservoir by considering the recorded historical earthquake data in the Korean Peninsula. The seismic fragility, a significant part of risk assessment, is updated by using Bayesian inference to consider the uncertainties and computational efficiency. The reservoir is one of the largest reservoirs in Korea for the supply of agricultural water. The intake tower controls the release of water from the reservoir. The seismic risk assessment of the intake tower plays an important role in the risk management of the reservoir. Site-specific seismic hazard is computed based on the four different seismic source maps of Korea. Probabilistic Seismic Hazard Analysis (PSHA) method is used to estimate the annual exceedance rate of hazard for corresponding Peak Ground Acceleration (PGA). Hazard deaggregation is shown at two customary hazard levels. Multiple dynamic analyses and a nonlinear static pushover analysis are performed for deriving fragility parameters. Thereafter, Bayesian inference with Markov Chain Monte Carlo (MCMC) is used to update the fragility parameters by integrating the results of the analyses. This study proves to reduce the uncertainties associated with fragility and risk curve, and to increase significant statistical and computational efficiency. The range of seismic risk curve of the intake tower is extracted for the reservoir site by considering four different source models and updated fragility function, which can be effectively used for the risk management and mitigation of reservoir.

Interannual and Seasonal Fluctuations of Nutrients, Suspended Solids, Chlorophyll, and Trophic Sate along with Other General Water Quality Parameters Near Two Intake Towers of Daechung Dam

  • Lee, Sun-Goo;Han, Jeong-Ho;Lee, Jae-Hoon;An, Kwang-Guk
    • 생태와환경
    • /
    • 제43권4호
    • /
    • pp.492-502
    • /
    • 2010
  • The study objects were to analyze long-term and seasonal variations of nutrients (N, P), suspended solids, N:P ratios, algal chlorophyll, and trophic state along with general water quality parameters in four sampling sites including two intake tower sites supplying drinking water in Daechung Reservoir. For the analysis, we used water quality long-term data sampled during 1998~2007 by the Ministry of Environment, Korea. Interannual and seasonal trends in inflow and discharge near the intake tower facilities over the ten years were directly influenced by rainfall pattern. The distinct difference between wet year (2003) and dry year (2001) produced marked differences in water temperature, pH, dissolved oxygen, organic matter contents, nutrients, and these variables influenced algal biomass and trophic state. Values of TP varied depending on the year and locations sampled, but monthly mean TP always peaked during July~August when river inflow and precipitation were maxima. In contrast, TN varied little compared to TP, indicating lower influence by seasonal flow compared to phosphorus. The number of E. coli were highest in Site 2 (Chudong intake tower) and varied largely, whereas at other sites, the numbers were low and low variations. Contents of chlorophyll-${\alpha}$ (CHL), as an estimation of primary productivity, varied largely depending on the year and season. The maximum of CHL occurred at Muneu intake tower (S4) during 2006 when the precipitation and inflow were lowest. In contrast, another CHL peak was observed in Site 2 (Chudong intake tower) in 2006 when one of the largest typoons (Ewinia) occurred and river runoff were maximum. So the CHL maxima were associated with both wet year (high flow, high nutrient supply) and dry year (low flow, nutrient supply by littoral zone). Such conditions influenced trophic states, based on Trophic State Index of nutrients and CHL. Based on all analyses, we can provide some clues for management and protection strategies of two intake tower sites.

Uncertainty reduction of seismic fragility of intake tower using Bayesian Inference and Markov Chain Monte Carlo simulation

  • Alam, Jahangir;Kim, Dookie;Choi, Byounghan
    • Structural Engineering and Mechanics
    • /
    • 제63권1호
    • /
    • pp.47-53
    • /
    • 2017
  • The fundamental goal of this study is to minimize the uncertainty of the median fragility curve and to assess the structural vulnerability under earthquake excitation. Bayesian Inference with Markov Chain Monte Carlo (MCMC) simulation has been presented for efficient collapse response assessment of the independent intake water tower. The intake tower is significantly used as a diversion type of the hydropower station for maintaining power plant, reservoir and spillway tunnel. Therefore, the seismic fragility assessment of the intake tower is a pivotal component for estimating total system risk of the reservoir. In this investigation, an asymmetrical independent slender reinforced concrete structure is considered. The Bayesian Inference method provides the flexibility to integrate the prior information of collapse response data with the numerical analysis results. The preliminary information of risk data can be obtained from various sources like experiments, existing studies, and simplified linear dynamic analysis or nonlinear static analysis. The conventional lognormal model is used for plotting the fragility curve using the data from time history simulation and nonlinear static pushover analysis respectively. The Bayesian Inference approach is applied for integrating the data from both analyses with the help of MCMC simulation. The method achieves meaningful improvement of uncertainty associated with the fragility curve, and provides significant statistical and computational efficiency.

대청호 정체수역의 수질예측과 관리 (Management of Water Quality of Embayments in Daechong Reservoir)

  • 이종호
    • 환경영향평가
    • /
    • 제3권2호
    • /
    • pp.33-45
    • /
    • 1994
  • Water quality of Chongju and Daejeon Water Intake Tower Region, embayments in Daechong Reservoir was found to be worse than that of main lake after analysis of water which were sampled during April, July, October in 1993. Concentration of COD and SS at those two water intake tower sites were 2.8-5.6 mg/l and 2.2-3.2 mg/l, higher than that of main lake. T-N concentration of those two sites was 1.1-1.9 mg/l similar to that of main lake, and T-P concentration of those two sites was 0.14-0.18 mg/l, higher than that of main lake. This study used water quality model of embayment which can analyse pollutant loads from stream and surrounding land use, advection, decay, and diffusion transport between embayment and main lake. The model can predict water quality of embayment according to the change of pollutant load, water elevation of embayment, quantity of water intake in order to suggest water quality management. This study suggests embayment water quality management alternatives, 1) construction of waste water treatment facilities at embayment and main lake for the decrease of pollutant loading, 2) water intake at main lake less polluted or eutrophicated than embayment, and 3) outflow elevation selection for polluted hypolimnion water outflow during stratification.

  • PDF

Development of a nonlinear seismic response capacity spectrum method for intake towers of dams

  • Cocco, Leonardo;Suarez, Luis E.;Matheu, Enrique E.
    • Structural Engineering and Mechanics
    • /
    • 제36권3호
    • /
    • pp.321-341
    • /
    • 2010
  • The seismic-induced failure of a dam could have catastrophic consequences associated with the sudden release of the impounded reservoir. Depending on the severity of the seismic hazard, the characteristics and size of the dam-reservoir system, preventing such a failure scenario could be a problem of critical importance. In many cases, the release of water is controlled through a reinforced-concrete intake tower. This paper describes the application of a static nonlinear procedure known as the Capacity Spectrum Method (CSM) to evaluate the structural integrity of intake towers subject to seismic ground motion. Three variants of the CSM are considered: a multimodal pushover scheme, which uses the idea proposed by Chopra and Goel (2002); an adaptive pushover variant, in which the change in the stiffness of the structure is considered; and a combination of both approaches. The effects caused by the water surrounding the intake tower, as well as any water contained inside the hollow structure, are accounted for by added hydrodynamic masses. A typical structure is used as a case study, and the accuracy of the CSM analyses is assessed with time history analyses performed using commercial and structural analysis programs developed in Matlab.