• Title/Summary/Keyword: Water Induction

Search Result 615, Processing Time 0.028 seconds

The Effect of Flow Induction Machine in Water Circulation System of Cheongna Canal Way (청라지구 물순환체계내 주운수로의 흐름유발시설 설치효과)

  • Kim, Dong-Eon;Choi, Gye-Woon;Park, Young-Sik;Yoon, Geun-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.77-81
    • /
    • 2010
  • This study carried out hydraulic model test for water circulation system in Cheongna district as part of Incheon Free Economic Zone. Canal way project of Cheongna was planned to establish for environment-friendly water circulation system, improve quality of life and diversification of traffic through using boat as a water-friendly international business city. The navigation canal, There are two intake facility in central park and it can purify water 15,000$m^3$ per day. After purify, water move to 8 facility of water culture area which supplies water in canal way. This process called water circulation system in cheongna. Also, there are several flow induction machine in canal way except south-north way. Therefore, this study will verify about validity of water circulation system's safety through hydraulic model test.

  • PDF

Study on Damage Mechanism Analysis and Recovery Characteristic of the Large Scale Steam Turbine Cased by Water Induction (대형 증기터빈 물유입에 의한 손상메커니즘 분석과 원상복구특성 연구)

  • Kim, D.Y.;Park, G.H.;Lee, B.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.22-29
    • /
    • 2011
  • In this study, the damage mechanism of large scale steam turbine due to water induction was analyzed and recovery characteristics were reviewed. A turbine consists of the rotating rotor and the stationary casing, and the clearance between them is very small for the efficiency enhancement. If water induction, while relatively cold steam or water is introduced into turbine, occurs, the considerable humping is caused at the casing near the initial water induction point and that induces the rubbing between rotor and casing. Finally, it leads to the catastrophic failure. Bowed rotor has the different characteristics in the recovery depending on damage degree. The elastic deformation due to light rubbing is recovered by turning the rotor with 3 rpm under normal operation condition, but most plastic deformation due to rubbing deforms the local microstructure and that results in permanent deformation which could not be recovered under normal operation condition. Bowed rotor has diverse characteristics depending on the recovery method, and the method is empirical and needs the cutting edge technology. Careful recovery treatment of the rotor will eliminate the risks and secure the high quality rotor similar to new rotor. If any critical error is made during the recovery, the rotor would not be recovered permanently and it should be scrapped.

A comparison of the operating characteristics of the synchronous generator and induction generator applied to the small hydroelectric power plant (소수력에 적용한 동기발전기와 유도발전기의 운전 특성 비교)

  • Kim, Jong-Gyeum;Kim, Young-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • In general, A synchronous generator is higher than the voltage stability of the induction generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So, coverage rate of the induction generator is gradually increasing in small hydroelectric power station rather than 1000kW recently. In order to increase the penetration of induction generator, pre-analysis of the operation of the generator is needed. In this study, we analyzed for the problems that occur when synchronous generator and induction generator of 1500kW is connected to the distribution system.

A study on the variation of power factor by connection of the induction generator to the distribution line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Kyung-Bae;Kim, Young-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1469-1470
    • /
    • 2015
  • Recently induction generator has been applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed how the power factor is changed according to the load increase or decrease in the distribution lines.

  • PDF

Development of Induction Heater Hot Water System using New Active Clamping Quasi Resonant ZVS PWM Inverter

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.11
    • /
    • pp.23-29
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current based stainless steel plate spiral type heater for heat exchanger or dual packs heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamping quasi-resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated for a high efficient induction heated hot water system and boiler in the consumer power applications. This consumer induction heater power appliance using active clamping soft switching PWM high frequency inverter is evaluated and discussed on the basis of experimental results.

A Study on the Application of Micro Hydro Power Generator at the Water Treatment Plant (정수장 마이크로 소수력 발전기 적용에 대한 연구)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Il-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.67-72
    • /
    • 2014
  • Inflow or outflow from the water treatment plant and the sewage water has potential energy. If this potential energy can be converted into electrical energy by water turbine generator, it can help to save energy because of the high capacity utilization. So recently, micro hydro power plant is reviewed in the water treatment facility. If generation capacity is low, induction generator is primarily used. If output capacity is low, generated power is supplied to the inside load. Induction generator can cause voltage drop by the inrush current at a start-up and requires reactive power for magnetization. In this study, we analyzed the flow of power and voltage variation against inrush current that occurs when the induction generator starts under the terms that loads of linear and non-linear of the water purification plant are used. Analysis results are that the voltage drop is within an allowable range and the power factor is slightly reduced by the need of reactive power.

Efficiency Analysis for Water Turbine Generator of Agricultural Reservoir (농업용 보의 수차 발전기 효율 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1223-1227
    • /
    • 2013
  • If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.

A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor (절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구)

  • Lee, Dong-Geun;Lee, Kwang-Ho;Choi, Kyo-Nam;Kim, Hyun-Il;Kwak, Hee-Jin;Oh, Bong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

The most appropriate starling method for induction moter (수도사업장 펌프모터(유도전동기)의 합리적 기동방법 시행을 위한 현장 실험)

  • Kim, Gi-Tae;Lee, Eun-Woong;Lee, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.33-34
    • /
    • 2006
  • When high-voltage motors are started, inrush current is rising as a serious power quality problem in terms of electric power line. So, this study is measured electrical data from induction motor's various starting method and is proposed the most appropriate starting method for induction motor at WTPs.

  • PDF