지하저수지(ASR) 유입수 전처리기법 개발: 물리적 폐색 저하 및 수량공급원활을 위한 2 단계 급속여과지 (Development of pre-treatment for the injection water into the aquifer storage and recovery(ASR) in Korea: The two-step rapid filter to reduce physical clogging and secure the volume of the injected water)

  • 박병주;도시현;홍성호
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.337-345
    • /
    • 2015
  • Two step rapid filter system as a pre-treatment for the injected water into aquifer storage and recovery (ASR) in Korea was developed to reduce physical blockage and secure the volume of the injected water. First, single rapid sand filters with three different media sizes (0.4~0.7, 0.7~1.0 and 1.0~1.4 mm) were tested. Only two sizes (0.4~0.7 and 0.7~1.0 mm) satisfied target turbidity, below 1.0 NTU. However, they showed the fast head loss. To prevent the fast head loss and secure the volume of the injected water, a rapid anthracite filter with roughing media size (2.0~3.4 mm) were installed before a single rapid sand filter. As results, both the target turbidity and reduction of head loss were achieved. It was determined that the media size for a rapid sand filter in two step rapid filter system (i.e. a rapid anthracite filter before a rapid sand filter) was 0.7~1.0 mm. In addition, the effects of coagulant doses on the removal of natural organic matter (NOM), which might cause a biological clogging, were preliminarily evaluated, and the values of $UV_{254}$, dissolved organic carbon (DOC) and SUVA were interpreted.

공기실을 사용한 압력수두의 완화효과에 대한 분석 (An Analysis of Attenuation Effect of Pressure Head Using an Air Chamber)

  • 이재수;윤용남;김중훈
    • 물과 미래
    • /
    • 제28권5호
    • /
    • pp.141-150
    • /
    • 1995
  • 공기실(air chamber)은 관망에 있어 압력수두가 설계치를 초과하지 않고 또한 최저 압력수두가 발생하지 않도록 하기 위해 설계된다. 따라서 공기실은 갑작스런 펌프의 중단에 따르는 순간적인 최고 및 최저 압력수두의 발생을 방지하기 위해 사용되어 진다. 본 연구에서는 가상적인 관망에 공기실을 적용하여 공기실의 공기부피, 위치, 면적, 오리피스에서의 손실계수 그리고 polytropic지수의 변화에 따른 압력수두의 완화효과를 분석하였다. 분석결과 공기의 부피가 증가할수록 최고압력수두는 감소하고 최저 압력수두는 증가함을 보여주었으며, 공기실의 위치나 단면적의 변화는 완화효과의 변화가 별로 없었다. 또한 오리피스 손실계수를 증가할수록 최고 압력수두가 감소함을 보이고, 공기실의 공기가 등온변화과정을 따를때가 단열변화과정을 따를 때보다 최고 압력수두가 낮음을 보여주었다.

  • PDF

수두손실률에 의한 방조제 침투류 감시기법 개발 (Development of the Seepage flow Monitoring Method by the Hydraulic Head Loss Rate on Sea Dike)

  • 임성훈;윤창진;김성필;허준;강병윤
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.60-68
    • /
    • 2010
  • In this study, the seepage flow monitoring method by hydaulic head loss rate graph was developed for the purpose of monitoring the seepage flow from the see side or from the lake on sea dike in which seepage force was varied periodically. The hydraulic head loss rate was defined in this method. The value of the rate is in the range from 0 to 1. the value of 0 means perfectly free flow of seepage. the value of 1 means perfect waterproofing. The value of coefficient of determination in the hydraulic head loss rate graph closer to 1 means that the seepage flow way is stable. The value of coefficient of determination in the hydraulic head loss rate graph closer to 0 means that the hole may exist or the piping may be in the progress. The pore water pressure data measured in Saemangeum sea dike was analyzed with the developed method The result showed that the variation of seepage flow state was detected sensitively by this method and the interception effect of sea dike could be estimated quantitatively.

  • PDF

과부하 사각형 맨홀의 배수능력 증대에 관한 실험적 연구 (An Experimental Study for Drainage Capacity Increment at Surcharged Square Manholes)

  • 김정수;송주일;윤세의
    • 상하수도학회지
    • /
    • 제22권6호
    • /
    • pp.619-625
    • /
    • 2008
  • Urban sewer systems are designed to operate in open-channel flow regime and energy loss at square manholes is usually not significant. However, the energy loss at surcharged manholes is considered as one of the major causes of inundation in urban area. Therefore, it is necessary to analyze the head loss associated with manholes, especially in surcharged flow. Hydraulic experimental apparatus which can change the manhole inner profile(CASE I, II, III, and IV) and the invert types(CASE A, B, C) were installed for this study. The experimental discharge was $16{\ell}/sec$. As the ratio of b/D(manhole width/inflow pipe diameter) increases, head loss coefficient increases due to strong horizontal swirl motion. The head loss coefficients for CASE I, II, III, and IV were 0.46, 0.38, 0.28 and 0.37, respectively. Side covers increase considerably drainage capacity at surcharged square manhole when the ratio of d/D(side cover diameter/inflow pipe diameter) was 1.0. The head loss coefficients for CASE A, B, and C were 0.45, 0.37, and 0.30, respectively. Accordingly, U-invert is the most effective for energy loss reduction at surcharged square manhole. This head loss coefficients could be available to evaluate the urban sewer system with surcharged flow.

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

CFD모사 기법을 이용한 관내 혼화장치내 수두손실 발생 특성 평가 (Evaluation of Head Loss within In-Line Mixer for Water Treatment using CFD Technique)

  • 황영진;임성은;김성수;박노석;왕창근
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.107-112
    • /
    • 2009
  • This study was conducted for verification and systematization of estimation method about the headloss using CFD(Computational Fluid Dynamics). Head loss which happens between the inlet and outlet of in-line mixer can be a major factor for the design and construction. Also, this Case studies about the sensitivity related to the velocity in the piping system. As result, program's default calculation function was used to get each side's total pressure and the differential of each total pressure could be defined as head loss from in-line mixer. In the case of adopting pipe surface friction factor and geometry loss, Calculation residual can be much more reduced. It was found that residual of value between CFD method and field test ranged about 3 through 18 precent.

고낙차 수력 펌프/터빈 런너에 대한 모우드 실험 (Modal Testing on a High Head Pump/Turbine Runner)

  • 류석주;하현천;김호종
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.278-282
    • /
    • 1997
  • This paper describes results of modal testing for a high head pump-turbine runner of the Muju pumped storage power plant. The head of the pump-turbine is 601 m and the outside diameter of its runner is 4,410 mm. The modal testing was done for two conditions : 1) the runner in air ; 2) the runner in water. For both conditions, obtained are natural frequencies, corresponding mode shapes and damping ratios. From the testing, it is found that the natural frequencies of the pump-turbine runner in water is reduced approximately 40 % due to additional mass effect of the water.

  • PDF

엔진 냉각 시스템 개선에 관한 실험적 연구 (An Experimental Study on Engine Cooling System Improvement)

  • 전문수;황용하
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.77-82
    • /
    • 2004
  • This paper describes the improvement of engine cooling system. To improve engine cooling performance, the authors approached in two ways. One is to increase water pump performance, changing of impeller shape and lightening of material were carried out. The second one is cooling efficiency rise, which were investigated with head gasket coolant flow passage optimization with flow visualization technique. The test results show that water pump performance was increased effectively, reduction of pump drive torque, and increase of pump flow-rate and pressure rise. Gasket hole pattern optimization test results represent an optimized head coolant flow which stands cross flow from exhaust to intake port side and small vortex were removed.

  • PDF

방류수의 수위 및 유량 분석을 통한 해양 소수력 성능평가 (Performance Evaluation of Ocean Small Hydropower Plant by Analyzing Water Level and Flow Rate of Circulating Water)

  • 강금석;김지영;유무성
    • 신재생에너지
    • /
    • 제5권3호
    • /
    • pp.32-39
    • /
    • 2009
  • The Samcheonpo ocean small hydropower plant (SHP) has a special feature of using marginal hydraulic head of circulating water system of fossil fuel power plant as a power source and having the characteristics of general hydropower generation and tidal power generation as well. Also, it contributes to reducing green house gases and developing clean energy source by recycling circulating water energy otherwise dissipated into the ocean. The efficiency of small hydropower plant is directly affected by effective head and flow rate of discharged water. Therefore, the efficiency characteristics of ocean hydropower plant are analyzed with the variation of water level and flow rate of discharged water, which is based on the accumulated operation data of the Samcheonpo hydropower plant. After the start of small hydropower plant operation, definite rise of water level was observed. As a result of flow pattern change from free flow to submerged flow, the instability of water surface in overall open channel is increased but it doesn't reach the extent of overflowing channel or having an effect on circulation system. Performance evaluation result shows that the generating power and efficiency of small hydropower exceeds design requirements in all conditions. Analysis results of CWP's water flow rate verify that the amount of flowing water is measured less and the highest efficiency of small hydropower plant is achieved when the effective head has its maximum value. In conclusion, efficiency curve derived from water flow rate considering tidal level shows the best fitting result with design criteria curve and it is verified that overall efficiency of hydropower system is satisfactory.

  • PDF