• 제목/요약/키워드: Water Exit Temperature

검색결과 58건 처리시간 0.026초

비등을 수반하는 발열면에 충돌하는 수분류의 임계열유속에 관한 연구 (Critical Heat Flux of an Impinging Water Jet on a Heated Surface with Boiling)

  • 이종수;김희동;최국광
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.485-494
    • /
    • 2000
  • The purpose of this paper is to investigate a critical heat flux(CHF) during forced convective subcooled and saturated boiling in free water jet system impinged on a rectangular heated surface. The surface is supplied with subcooled or saturated water through a rectangular jet. Experimental parameters studied are a width of heated surface, a height of supplementary water and a degree of subcooling. Incipient boiling point is observed in the temperature of 6${\~}8^{\circ}C$ of superheat of test specimen. CHF depends on jet velocity for various boiling-involved coolant system. CHF also is proportional to the nozzle exit velocity to the power of n, where n is 0.55 and 0.8 for subcooled and saturated boiling, respectively. CHF is enhanced with a higher jet velocity, higher degree of subcooling and smaller width of a heated surface.

물입자를 분사하는 원심압축기의 성능해석 (Performance Analysis of Centrifugal Compressor in Wet Compression)

  • 강정식;차봉준;양수석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.237-242
    • /
    • 2005
  • 가스터빈엔진에서 압축기가 사용하는 에너지는 터빈에서 생성하는 에너지의 $30-50\%$까지도 이르기 때문에 압축기의 일을 줄이는 연구는 가스터빈의 효율을 증가시키는 문제와 연관된 중요한 연구주제이다. 압축기의 일을 줄이는 한 가지 방법으로 압축기의 입구에 물입자를 분사하는 방법이 제안되었는데, 이 방법은 물입자가 증발하면서 압축기 출구의 온도를 낮추어서 결과적으로 압축과정에 소요되는 에너지를 줄일 수 있는 방법이다. 이전까지의 연구는 열역학적 해석에 집중하여 온도 및 일의 감소를 해석하거나, 실험에 근거하여 가스터빈의 성능변화에 집중되었다. 본 논문에서는 물분사의 영향을 마이크로터빈용 원심압축기에 적용하여 열역학적 해석 뿐 아니라 공력학적 해석을 수행하였다. 물을 분사할 경우 공기압축과정보다 임펠러 출구 유동각이 줄어들었으며, 증발율이 높을수록 유동각 감소가 증가하였고, 압력비가 낮을수록 유동각 감소가 증가하였다.

  • PDF

LNG 개방래크 기화기의 해석 및 설계 (Analysis and design of LNG open rack vaporizer)

  • 박정수;장호명
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.189-197
    • /
    • 1997
  • The vaporizing characteristics of LNG(liquefied natural gas) via heat exchanger with sea water are analytically studied for an open rack vaporizer(ORV). This study is intended to supply the design data for the domestic fabrication of the corrosion-resistant vaporizer tube. A computational program is developed to predict the exit temperature of LNG for various conditions. In the program, thesimple and justifiable heat transfer models are selected for fully-developed internal flow of LNG, the star-shaped finned-tube, and the external falling films of sea water, as well as the possible ice formation and the fouling on the tube walls. It is found that the enongh corrugation inside of the tube wall is the most significant in the vaporizer performance for the current operating conditions. the effects of other design parameters on the heat exchanger between LNG and sea water are quantitatively presented.

  • PDF

5 RT 공랭형 $NH_3-H_2O$ 흡수식 냉동기의 발생기 입력 열량과 외기온도 변화에 따른 성능분석 (Performance Analysis of a 5 RT Air-Cooled $NH_3-H_2O$ Absorption Chiller with the Variations of Heat Input and Ambient Temperature)

  • 윤희정;김성수;강용태
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.438-443
    • /
    • 2004
  • The objective of this paper is to study the effects of the input gas flow rate and the ambient temperature variation on the absorption cycle performance. An air-cooled NH$_3$-$H_2O$ absorption chiller is tested in the present study. The nominal cooling capacity of the single effect maching is 17.6 ㎾ (5.0 USRT). The cooling capacity, coefficient of performance, burner efficiency, and each state point are measured with the variations of the heat input and the ambient temperature. It is found that the COP and cooling capacity increase with increasing the generator exit temperature up to a certain temperature and then decrease. It is also found that the COP and the cooling capacity decrease with increasing the ambient temperature. The maximum COP of 0.51 is obtained from the present experiment.

충돌형 분사기 형태의 액체로켓엔진용 가스발생기 연소성능시험 (Combustion Performance Tests of Fuel-Rich Gas Generator for Liquid Rocket Engine Using an Impinging Injector)

  • 한영민;김승한;문일윤;김홍집;김종규;설우석;이수용;권순탁;이창진
    • 한국추진공학회지
    • /
    • 제8권2호
    • /
    • pp.10-17
    • /
    • 2004
  • 본 논문에서는 액체로켓엔진용 160 kW급 터보펌프의 터빈을 구동하고, 액체산소와 케로신을 추진제로 사용하는 연료 과잉 가스발생기의 설계점 연소성능시험 결과에 대해 논의하였다. 충돌형 F-O-F 분사기로 구성된 헤드부, 물냉각 채널 연소실, torch igniter, turbulence ring 그리고 측정 링을 갖는 가스발생기에 대해 기술하였고, 설계점에서의 연소시험 및 turbulence ring 장착여부. 연소실 길이 변화에 따른 연소시험의 결과들에 대해 기술하였다. 연소시험 결과 가스발생기는 설계점에서 안정된 작동성을 보여주었고. 연소압력 및 온도 등의 성능은 예측치에 근접하는 결과였다. Turbulence ring은 출구에서의 가스온도를 균일하게 분포시켜 효과적인 혼합 장치임을 보여 주었고, 4∼6msec 정도에서의 연소가스 잔류시간은 연소효율에 큰 영향을 주지 않았다. 가스발생기 출구에서의 온도는 공급되는 추진제의 O/F ratio에 따라 매우 민감하게 변화하였다.

SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석 (A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production)

  • 변현승;한단비;박성룡;조종표;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.

충돌 제트에서 Rod 형상 변화에 따른 주변 유동 특성연구 (A Study on The Flow Characteristics according to Changes of Rod Shape on Impinging Jet)

  • 손승우;이상범;강도훈;송민근;주은선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.525-528
    • /
    • 2002
  • The objective of this study is to investigate characteristics of flow by the Rod shape and the choice of the turbulent intensity enhancement section. The Rod was setup vertically to the way of a nozzle exit flow and nozzle diameter is 17mm. Rod height is 5mm and its shapes are square, triangle, and circle. Characteristics of fluid such as velocity vector distribution, kinetic energy, turbulent intensity, and etc. were visualized, observed, and considered at 3 kinds of Re No. such as 2000, 3000, and 4000. The characteristics of flow field were investigated in each case of the distance rate from the nozzle exit to impinging plate(H/B=8, 10). The temperature of water is $20^{\circ}E$ and the measurement region divided by 3 sections(I, II, III). The nozzle diameter is 17mm. As the experimental result by PIV measurement, scale of the vector profile showed a tendency to an unbalance parabola distribution as increasing of the Re No. When the impinging plates such as square, triangle, and circle shape are installed respectively in front of the flow accelerated, rod shape of the highest velocity vector is circle shape and rod shape of the highest turbulent Intensity is square shape.

  • PDF

냉음극형 대면적 전자빔의 공간적 분포 특성 (Characteristics of spatial distribution of cold cathode type large aperture electron beam)

  • 우성훈;;조주현;김광훈;이홍식;임근희;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2170-2172
    • /
    • 1999
  • A low energy large aperture(LELA) pulsed electron beam generator of a cold cathode type has been developed for environmental applications, for example, waste water cleaning, flue gas cleaning, and pasteurization etc. The operational principle is based on the emission of secondary electrons from cold cathode when ions in the plasma hit the cathode, which are accelerated toward exit window by the gradient of an electric potential. We have fabricated the LELA electron beam generator with the peak energy of 200keV and beam diameter of 200mm and obtained the large aperture electron beam in air. The electron beam current density has been investigated as a function of glow discharge current, accelerating voltage and radial distribution in front of the exit window foil. The plasma density and electron temperature have been measured in order to confirm the relation with the electron beam current density. We are going to upgrade the LELA electron beam generator in the electron energy, electron beam current and stability of operation for various applications.

  • PDF

나선코일 튜브 내에서의 압력손실에 관한 연구 (A Study on the Pressure Loss in Helically Coiled Tubes)

  • 한규일;박종운
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.155-165
    • /
    • 1998
  • The resistance coefficient and heat transfer performance are studied for the turbulent water flow in a smooth coiled tube having variable curvature ratios and a corrugated-coiled tube having a ratio of coil to tube diameter of 22. Experiments are carried out for the fully developed turbulent flow of water in tube coils on the uniform wall temperature condition. This work is limited to tube coils of R/a between 22 and 60 and Reynolds numbers from 13000 to 53000. The tube having a ratio of coil to tube diameter of 27 among the 3 smooth tube coils shows the best heat transfer performance. A corrugated-coiled tube(R/a=60) shows more excellent performance than a smooth coiled tub (R/a=60) at a similar curvature ratio. The friction factor f is sensitive to changes in the velocity profile caused by a temperature gradient. Allowance was made for the pressure loss in the short inlet and outlet lengths and due to the presence of the thermocouple inlet and outlet as a result of separate experimental on a straight tube. It is to be expected that the allowance at the exit will be somewhat too low because of secondary flow effects carried over from the coil.

  • PDF

백연 저감을 위한 열교환 시스템의 배기 열전달 특성에 관한 연구 (Study on Exhaust Air Heat Transfer Characteristics of Heat Exchange System for White Smoke Reduction)

  • 왕쩐후안;전종균;권영철
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.739-744
    • /
    • 2018
  • In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about $40^{\circ}C$ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.