• Title/Summary/Keyword: Water Entry Point

Search Result 16, Processing Time 0.026 seconds

A Development Method for Water Entry Point Selection Algorithm by Detection Probability Analysis (탐지확률 분석에 의한 입수점 선정 알고리듬 개발 방안)

  • Cho, Sung-Bong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.30-37
    • /
    • 2007
  • In this paper, Water Entry Point Selection Algorithm(WEPSA) for selecting an optimal Water Entry Point of anti-submarine missiles which maximizes Detection Probability about a given target was investigated. WEPSA is a method which decides the position of an optimal Water Entry Point with calculating the target Detection Probability of a torpedo in the whole domain which centered by the target, performing the Monte-Carlo Simulations which include errors for the target informations and for weapon delivery. We can decide an optimal Water Entry Point of anti-submarine missiles which maximizes Detection Probability about a given target with WEPSA, if we get target informations about target range, target bearing, target speed and target course from Combat Systems.

Comparison of Potential and Viscous Codes for Water Entry Problem

  • Kwon, Sun-Hong;Park, Chang-Woo;Shin, Jae-Young
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.1
    • /
    • pp.32-36
    • /
    • 2012
  • This paper presents a comparison of potential and viscous computational codes for the water entry problem. A po-tential code was developed which adopted the boundary element method to solve the problem. A nonlinear free surface boundary condition was integrated to find new locations of free surface. The dynamic boundary condition was simplified by taking constant potential values for every time steps. The simplified dynamic boundary condition was applied in the new position of the free surface not at the mean level, which is the usual practice for linearized theory. The commercial code FLUENT was used to solve the water entry problem from the viscosity point of view. The movement of the air-liquid interface is traced by distribution of the volume fraction of water in a computational cell. The pressure coefficients were compared with each other, while experimental results published by other researchers were also examined. The characteristics of each method were discussed to clarify merits and limitations when they were applied to the water entry problems.

Test and Evaluation for Time Delay Function of Point Detonating Fuze by Underwater Sound Analysis (수중음향 분석을 통한 충격신관 지연기능 시험평가)

  • Na, Taeheum;Jang, Yohan;Jeong, Jihoon;Kim, Kwanju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.217-224
    • /
    • 2017
  • This study proposes an evaluation method for time delay function(TDF) of Point Detonation(PD) fuse using underwater explosion and water entry phenomena. Until now, nothing but the naked eyes of an observer or video images have been used to determine whether the TDF of PD fuze is operated or not. The observer has verified the performance of TDF by analysing the shape of the plume formed by underwater explosion. However, it is very difficult to evaluate the TDF of PD fuse by these conventional methods. In order to overcome this issue, we propose a method using underwater sound signal emitted from the underwater explosion of high explosive charge. The result shows that the measured sound signal is in accord with the physical phenomena of water entry of warhead as well as underwater explosion. Also, from the hypothesis test of bubble period, difference on underwater sound analysis between dud event and delay one is proved.

Study on Improvement of tap water drinking rate of Seoul city Tap water 'Arisu' through usage and recognition analysis (서울시 수돗물 '아리수' 사용현황과 인식 분석을 통한 수돗물 직접 음용률 제고 방안 연구)

  • Min, Sae-yan;Kim, Seung-In
    • Journal of Digital Convergence
    • /
    • v.16 no.9
    • /
    • pp.399-404
    • /
    • 2018
  • The purpose of this study is to raise the drinking rate of Arisu, the tap water in Seoul, and to propose new solution for continuous water quality management and raising awareness. The research scope was limited to point-of-use water treatment system, and based on the this contents I proceed this study how this will help to increase direct drinking rate of Arisu. Through research, Korea has provided users with the ability to filter contaminated tap water simply as water to be rinsed through water purification. Therefore, it was predicted that it would be difficult to improve tap water as drinking water. With this study, I expect that the strength of point-of-use system and the reliability of tap water quality will be raised and hope various product will be developed to improve the perception as drinking water and I also expect that this can be applied to whole country even further in the scope of Seoul city.

Stability analysis of an unsaturated slope considering the suction stress (흡입응력을 고려한 불포화 사면의 안정해석법)

  • Song, Young-Suk;Lee, Nam-Woo;Hwang, Woong-Ki;Kim, Tae-Hyung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.764-771
    • /
    • 2010
  • The stability analysis method of an unsaturated slope considering the suction stress was performed on the infinite sand slope. During drying and wetting processes, the Soil-Water Characteristics Curve (SWCC) of the sand with the relative density of 75% was measured using the automated SWCC apparatus. Also, the Suction Stress Characteristics Curve (SSCC) was estimated. Based on these results, the stability analysis of an unsaturated infinite slope was carried out considering the slope angle, the weathering zone and the relative change in friction angle as a soil depth. According to the result of slope stability analysis, the safety factors of slope were less than 1 when the slope angles were more than $50^{\circ}$. The safety factors of slope tend to increase with increasing the depth from the ground surface. Especially, the safety factors have a tendency to increase and decrease above near the ground water level due to the suction stress. The maximum safety factor of slope in this analysis was occurred at the Air Entry Value (AEV) of drying process. The influence range of suction stress above the ground water level can be found out and can be defined as the funicular zone which means the metric suction range from the air entry point to the point of residual volumetric water content.

  • PDF

Feasibility Study on Introduction of Decentralized Water Supply System for Improving Water Security and Sustainability (물안보 및 지속가능성 제고를 위한 분산형 용수공급시스템의 도입 타당성에 관한 연구)

  • Kim, Kwan-Yeop;Kim, Seong-Su;Park, No-Suk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.111-124
    • /
    • 2014
  • Decentralized water supply systems, treating the water in users'vicinity, cutting down the distribution system, utilizing the alternative water resources(rainwater harvesting, water reclamation and reuse and so on.) and saving energy and other resources, could be categorized into POU(Point-Of-Use), POE(Point-Of-Entry) and community small scale system. From the literature review, we could thought that decentralized water supply system and hybrid system(integrating centralized and decentralized water supply system within urban water management) might have strengthening comparative advantages to centralized system with respect to: (1) water security, (2) sustainability, (3) economical affordability. Even though it is difficult to derive and quantify direct benefit advantages from decentralized and hybrid system in comparison with centralized system, (1) operational cost reduction, (2) assurance for safe and stability water supply and (3) greenhouse gas reduction can be expected from successful establishment of the former.

A simplified directly determination of soil-water retention curve from pore size distribution

  • Niu, Geng;Shao, Longtan;Sun, De'an;Guo, Xiaoxia
    • Geomechanics and Engineering
    • /
    • v.20 no.5
    • /
    • pp.411-420
    • /
    • 2020
  • Numbers fitting-curve equations have been proposed to predict soil-water retention curve (SWRC) whose parameters have no definitude physical meaning. And these methods with precondition of measuring SWRC data is time-consuming. A simplified directly method to estimate SWRC without parameters obtained by fitting-curve is proposed. Firstly, the total SWRC can be discretized into linear segments respectively. Every segment can be represented by linear formulation and every turning point can be determined by the pore-size distribution (PSD) of Mercury Intrusion Porosimetry (MIP) tests. The pore diameters governing the air-entry condition (AEC) and residual condition (RC) can be determined by the PSDs of MIP test. The PSD changes significantly during drying in SWR test, so the determination of AEC and RC should use the PSD under corresponding suction conditions. Every parameter in proposed equations can be determined directly by PSD without curve-fitting procedure and has definitude physical meaning. The proposed equations give a good estimation of both unimodal and bimodal SWRCs.

Contamination Sources of Several Potentially Hazardous Compounds Found at the Gap Stream and the Miho Stream, Two Major Tributaries of the Geum River (금강 수계 주요지류인 갑천과 미호천에서 잠정유해물질 오염원 확인 연구)

  • Lee, Jun-Bae;Lee, Jay-Jung;Cho, Yoon-Hae;Yoon, Jo-Hee;Hong, Seoun-Hwa;Lee, Dae-Hee;Lee, Dae-Hee;Cho, Young-Hwan;Shin, Ho-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2016
  • BACKGROUND: Water quality is of concern to water utility operators, public health officials, and populations using the water. If any contaminant is released from a point of entry, it could be spread rapidly throughout the water stream. So the identification of the location of the points of entry and its release history are critical informations to establish the management strategy.METHODS AND RESULTS: Aniline, nonylphenol, pentachlorophenol and formaldehyde in 39 surface water samples were analysed using Gas chromatography-mass spectrometry (GC-MS) methods. Formaldehyde, aniline and nonylphenol were mainly detected in the near sites where industrial waste water and domestic sewage were discharged into stream. But pentachlorophenol was detected in the downstream samples where pulp manufacturing plants were operated.CONCLUSION: Results indicate that pentachlorophenol found in main stream of Guem river was mainly introduced from pulp manufacture industries. Otherwise, formaldehyde, aniline and nonylphenol were mainly contaminated from the industrial waste water and domestic sewage.

An Experimental Study on Slamming Impact Pressure and Flow Characteristics by Free Fall of Rectangular Marine Structure (직사각형 해양구조물의 자유낙하 슬래밍 충격압력 및 유동특성에 관한 실험적 연구)

  • Oh, Seung-Jin;Gim, Ok-Sok;Lee, Gyoung-Woo;Cho, Dae-Wan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.371-377
    • /
    • 2012
  • This paper presents an experimental investigation to figure out slamming impact pressure and flow characteristics of a rectangular Marine structure($800{\times}250{\times}50mm^3$) in free fall. The flow field has been obtained by 2-frame grey level cross correlation PIV(Particle Image Velocimetry) method, the impact pressure of the free fall model by a pressure acquisition system(Dewatron). The angles between a model and the free surface are adapted $10^{\circ}$ and $20^{\circ}$ respectively. Velocity field of water exit has higher better than water entry. The highest point, P2 of impact pressure under the bottom of the model has been appeared about 6 % higher values at 20 degrees than 10 degrees.

Regional Differences of Entry Rate of Freely Diffusible Substances from Peritoneal Cavity (복강내 확산성 물질의 부위별 흡수속도)

  • Cho, Byeong-Deuck;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.157-168
    • /
    • 1967
  • The entry of antipyrine and urea from the peritoneal cavity of rabbit into organ tissue and blood plasma was studied. Two hundred mg of antipyrine plus 300 mg of urea in 10 ml Ringer's solution was injected into the peritoneal cavity of anesthetized rabbit. The injection was made from above of a rabbit kept tying right side down and it enabled part of the abdominal organs (liver, intestine, kidney) was immersed in the injected solution and kept high concentration gradient throughout the experimental period. The remaining part of the organs was revered only by a thin film of the test solution. Subsequently, in this part of the organs the concentration gradient of the diffusible substances during entry was presumed to decrease as time elapsed. Four pieces of the liver tissue were taken namely, the right superficial, right deep, left superficial and left deep portions. Two were taken from the small intestine, one from the portion which was immersed in. the fluid and the other from that above the fluid mass. Both kidneys were separately analyzed. As a remote organ the gastrocnemius muscle was taken from the right leg of the animal. The intervals which were the time periods elapsed after injections were 5,7,10,15 or 30 minutes. At each point 5 animals were sacrificed and the concentrations of the test substances in the tissue water were measured. The results obtained were as follows. 1. In the liver the right portion which was immersed in the fluid showed higher concentration if the test substances than the left portion and the superficial region exceeded the deep region. The concentrations diminished as the time elapsed after infusion, particulary in the case of antipyrine, suggesting circulatory removal of the substances. In urea such decreasing tendency of the concentration was not obvious, and suggested slower removal rate of it as compared with that of antipyrine. 2. In the small intestine there was no regional difference in the concentration of the test substances. Because of the intestinal motility different portions of the intestine were seemed to have bathed in the fluid of the same concentration. In general the concentrations in the intestinal wall exceeded those of the liver, suggesting a slower removal rate than in the latter. 3. In the kidney the accumulation of the endogenous urea was predominant, and the accumulating mechanism in the renal tissue went on during the period of the experiment. Therefore it revealed increasing tendencies as the time elapsed. The penetration of the test substances in this organ from the peritoneal cavity seemed to be slower than in other abdominal organs, namely liver or small intestine. Part of the test substances in the kidney were obviously brought by the blood stream. 4. Rapid exponential decay of the concentration of antipyrine and of the osmolality of the peritoneal fluid was attributed to the extensive removal through the whole dimension of the peritoneal surface, and the remote organ such as the gastrocnemius muscle attained a fairly close value to that of the abdominal organs in less than 30 minutes. The factors which related to the absorption rate were discussed. They were the concentration gradient, permeability and the regional perfusion rate.

  • PDF