• 제목/요약/키워드: Water Distribution Systems

검색결과 547건 처리시간 0.035초

Impact of Water Quality Parameters on the Disinfection of Total Coliform with Chlorine Dioxide

  • Lee Yoon-Jin
    • 한국환경보건학회지
    • /
    • 제32권3호
    • /
    • pp.215-221
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine dioxide, in order to assess the optimal disinfection procedure for drinking water treatment and distribution systems. This research focus on a number of factors, including the dosage of disinfectant, contact time, pH, temperature and DOC. Water samples were taken from the outlet of a settling basin at a conventional surface water treatment system. As the pH increased in the range of pH 6-9, the bactericidal effects of disinfectants decreased. Changes in levels of pH did not significantly after the disinfection effect of chlorine dioxide for total coliform. With an increase in temperature, there was a subsequent increase in the bactericidal effects of disinfectants. Thus, it is evident that a decrease in temperature will higher the CT values required to inactivate coliform for during the winter. DOC addition can also reduce total coliform inactivation. DOC is the most significant variable in total coliform inactivation with chlorine dioxide.

하천유역 수질 관측망 구성 연구 (Construction of Observational Locations for Measuring Water Quality in the River Area)

  • 권세혁;오현승
    • 산업경영시스템학회지
    • /
    • 제35권3호
    • /
    • pp.187-191
    • /
    • 2012
  • The methods for constructing network of observational locations for measuring water quality in water reservoirs have been widely proposed, but they had some limitations to be applied to river areas, which lie in awkward clustering and finding representative observational locations among locations within each clustering. In this paper, a statistical approach to detect anomaly locations which were significantly different in important measurements for the water quality from the previous locations and construct observational network with them was proposed. Anomaly was detected with the sampling distribution of each primary principal component score, sum of primary PCs, or sum of residual PCs. The empirical study with the data of Nakdong Dam for guiding how to use our proposed approach and showing limitations of previous studied was described.

일부 농촌지역 간이상수도의 운영실태와 수질에 관한 조사연구 (A Study on the Drinking Water Quality and Problem of Simple Piped Water Supply System in a Rural Area)

  • 김영규
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.39-51
    • /
    • 1992
  • This study was carried out for 1 year between 1990 and 1991. The interviewers visited 513 households to evaluate the perception of the residents using the Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 48 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are summarized as follows: 1) Approximately 44.0% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 8 sites and valley water in 40 sites. 3) Considering the type of distribution of the SPWS, there are 40 natural gravity systems and 8 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 73.9% of the SPWS facilities %'ere used more than ten years. 5) 47.4% of the SPWS facilities are neighbored with pollution source. 6) 42.4% of the maintenance crews were not committed to their job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 36.9% of the residents complaind that the amount of daily water supply is not adequate. 8) About 55.6% of the residents felt that the water quality is good for drinking water and therefore, But in contrast, the biochemical tests indicated that most of the SPWS met the drinking water quality standards. 9) Under the present water analysis system, The method of sampling and analysis are not effective, so that analysis system shoud be done by local health center.

  • PDF

물안보 및 지속가능성 제고를 위한 분산형 용수공급시스템의 도입 타당성에 관한 연구 (Feasibility Study on Introduction of Decentralized Water Supply System for Improving Water Security and Sustainability)

  • 김관엽;김성수;박노석
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.111-124
    • /
    • 2014
  • Decentralized water supply systems, treating the water in users'vicinity, cutting down the distribution system, utilizing the alternative water resources(rainwater harvesting, water reclamation and reuse and so on.) and saving energy and other resources, could be categorized into POU(Point-Of-Use), POE(Point-Of-Entry) and community small scale system. From the literature review, we could thought that decentralized water supply system and hybrid system(integrating centralized and decentralized water supply system within urban water management) might have strengthening comparative advantages to centralized system with respect to: (1) water security, (2) sustainability, (3) economical affordability. Even though it is difficult to derive and quantify direct benefit advantages from decentralized and hybrid system in comparison with centralized system, (1) operational cost reduction, (2) assurance for safe and stability water supply and (3) greenhouse gas reduction can be expected from successful establishment of the former.

설계갈수량의 유도를 위한 수문통계학적 연구 (I) (Statistical Studies on the Derivation of Design Low Flows (I))

  • 이순혁;박영근;박종근
    • 한국농공학회지
    • /
    • 제34권3호
    • /
    • pp.43-52
    • /
    • 1992
  • Design low flows were derived from the decision of a best fitting probability distribution and of an optimum transformation method can be contributed to the planning of water utilization and management of various hydraulic structures during dry season in the main river systems in Korea. The results were analyzed and summarized as follows. 1.Basic statistics for the selected watersheds were calculated as one of means for the analysis of extremal distribution. 2.Parameters for the different frequency distributions were calculated by the method of moment. 3.Type m extremal distribution was confirmed as a best one among others for the frequency distribution of the low flows by x$^2$ goodness of fit test. 4.Formulas for the design low flows of the Type m extremal distribution with two and three parameters were dervied for the selected watersheds. 5.Design low flows for the Type m extremal distribution when a minimum drought is zero or larger than zero were derived for the selected watersheds, respectively. 6.Design low flows of the Type m extremal distribution with two parameters are appeared to be reasonable when a minimum drought approaches to zero and the observed low flows varied within a relating small range while those with three parameters are seemed to be consistent with the probability distribution of low flows when a minimum drought is larger than zero and the observed low flows showed a wide range.

  • PDF

Pattern Recognition of Meteorological fields Using Self-Organizing Map (SOM)

  • Nishiyama Koji;Endo Shinichi;Jinno Kenji
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.9-18
    • /
    • 2005
  • In order to systematically and visually understand well-known but qualitative and rotatively complicated relationships between synoptic fields in the BAIU season and heavy rainfall events in Japan, these synoptic fields were classified using the Self-Organizing Map (SOM) algorithm. This algorithm can convert complex nonlinear features into simple two-dimensional relationships, and was followed by the application of the clustering techniques of the U-matrix and the K-means. It was assumed that the meteorological field patterns be simply expressed by the spatial distribution of wind components at the 850 hPa level and Precipitable Water (PW) in the southwestern area including Kyushu in Japan. Consequently, the synoptic fields could be divided into eight kinds of patterns (clusters). One of the clusters has the notable spatial feature represented by high PW accompanied by strong wind components known as Low-Level Jet (LLJ). The features of this cluster indicate a typical meteorological field pattern that frequently causes disastrous heavy rainfall in Kyushu in the rainy season. From these results, the SOM technique may be an effective tool for the classification of complicated non-linear synoptic fields.

  • PDF

전오존처리에 의한 상수원수의 생물학적 처리효율제고에 관한 연구 (A Critical Review for the Effect of Ozonation on Biodegradability in Drinking Water Treatment Systems)

  • 남상호
    • 수도
    • /
    • 제24권4호통권85호
    • /
    • pp.79-87
    • /
    • 1997
  • In an effort to prevent the formation of DBPs from disinfection and the microbial regrowth in distribution systems, the ozonation followed by biological filtration process in drinking water treatment train has been recently developed as an alternative process to reduce effectively water-born organic matter as precursor. There are, however, insufficient for the consistent information and data about the relation between ozone dosage based on organic surrogate parameter, TOC or DOC and effect of ozonation on BDOC formation. This study is to review critically for the effect of ozonation on biodegradability on the basis of published technical papers including the output from author's research laboratory. It truned out that : 1. ozonation in the presence of organic matter has a tendancy to increase in BDOC content, 2. the rate of BDOC formation was maximum below 1mg $O_3/mg$ DOC of ozone dose, but about maximum content of BDOC was obtainable at the range from 1.5mg $O_3/mg$ DOC to 2mg $O_3/mg$ DOC, 3. from above 1mg $O_3/mg$ DOC, the rate of BDOC formation became slow down, 4. from above 2mg $O_3/mg$ DOC, BDOC formation was quantitatively negligible, In conclusion, it needs further systematic study and research concerned to biodegradability and treatability by ozonation in terms of organic characteristics and experimental conditions because it was hard to find out the consistent experimental data comparable each other that were performed by numbers of research authors.

  • PDF

도시유역의 내수배제시스템 설계를 위한 유출특성분석 -SWMM의 적용- (Runoff Characteristics Analysis for Interior Drainage Systems in Urban Basin -Application of SWMM-)

  • 최윤영;이영화
    • 한국환경과학회지
    • /
    • 제9권3호
    • /
    • pp.193-199
    • /
    • 2000
  • This study is carried out the analysis of the runoff characteristics for the design of the interior drainage systems by SWMM in urbanization basin. The basin analyzed in this study is Bumuh-chun basin which is located in Susung-gu of Taegu city. Huff method is used for rainfall distribution analysis. The optimal rainfall duration in Bumuh-chun basin is analyzed as about 90 minutes decided from comparison of arrival time and critical duration. Flood flow variation pattern is proposed through the comparison of the results of peak flow and peak time analyzed by SWMM about pre-urbanization and post-urbanization of Bumuh-chun basin. It is known that the variation of arrival time caused by the rapid increase of pavement rate in the upper area shows about 20∼25 minutes faster than pre- urbanization. Therefore, the management of surface water for design of water supply and drainage, and channel alteration has to considered the variation of geological factors according to urbanization.

  • PDF

Web기반 GIS를 이용한 금강유역의 실시간 수문지형인자 추출 (Web-based GIS for Real Time Hydrologic Topographical Data Extraction for the Geum River Watershed in Korea)

  • 남원호;최진용;장민원
    • 한국농공학회논문집
    • /
    • 제49권5호
    • /
    • pp.81-90
    • /
    • 2007
  • Watershed topographical information is required in hydrologic analysis, supporting efficient hydrologic model operation and managing water resources. Watershed topographical data extraction systems based on desktop GIS are abundant these days placing burdens for spatial data processing on users. This paper describes development of a Web-based Geographic Information Systems that can delineate the Geum River sub-basins and extract watershed topographical data in real time. Through this system, users can obtain a watershed boundary by selecting outlet location and then extracting topographical data including watershed area, boundary length, average altitude, slope distribution about the elevation range with Web browsers. Moreover, the system provides watershed hydrological data including land use, soil types, soil drainage conditions, and NRCS(Natural Resources Conservation Service) curve number for hydrologic model operation through grid overlay technique. The system operability was evaluated with the hydrological data of WAMIS(Water Management Information System) with the government operation Web site as reference data.

일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구 (A Study on the Simple Piped Water Supply System in a Rural Area)

  • 정문호
    • 한국환경보건학회지
    • /
    • 제17권1호
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF