• 제목/요약/키워드: Water Distribution Systems

검색결과 547건 처리시간 0.045초

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

Sequential Copolypeptides (Ⅲ). Synthesis and Characterization of Poly ($\gamma$-benzyl-L-glutamyl-$\gamma$-benzyl-L-glutamyl-glycine)

  • Choi, Sang-Up;Kang, Joon-Kil
    • Bulletin of the Korean Chemical Society
    • /
    • 제1권3호
    • /
    • pp.78-82
    • /
    • 1980
  • Solutions of $Cd^{2+}$, $Co^{2+}$ and $Ni^{2+}$ were mixed with the solutions of hydroxycarboxylic acids such as salicylic, lactic and mandelic acids in the presence of cation exchange resin at room temperature. The distribution ratios of the metal ions between resin and solution were measured, using radioactive metal ions as tracer. From the observed variation of the distribution ratios with the acid anion concentrations, it was concluded that $Cd^{2+}$, $Co^{2+}$ and $Ni^{2+}$ formed the one-to-one complexes with salicylate, lactate and mandelate ions in aqueous, 20 % ethanol-water and 20 % acetone-water solutions. The results of the present study indicated that the relative stabilities of the metal-acid complexes in solution increased in the order: $Cd^{2+}$ <$Co^{2+}$ <$Ni^{2+}$ complexes. Salicylate

엔트로피 이론을 이용한 상수관망의 최적 압력 계측 위치 결정 (Determination of Optimal Pressure Monitoring Locations for Water Distribution Systems using Entropy Theory)

  • 정건희;장동일;유도근;전환돈;김중훈
    • 한국수자원학회논문집
    • /
    • 제42권7호
    • /
    • pp.537-546
    • /
    • 2009
  • 상수관망의 유지 관리를 위한 최적 압력 계측 위치 선정은 효율적인 상수관망 운영을 위해 필수적이다. 본 연구에서는 최적 압력 계측 위치 결정에 기존 연구의 단점을 보완하기 위하여 정보이론인 엔트로피 이론을 사용하였다. 기존의 방법은 실측자료를 이용한 검 보정이 필요로 하기에 체계적인 관리가 미흡한 지역에서는 적용이 어려운 단점이 있다. 또한 대부분의 연구가 상수관망 모형의 정확도를 높이며 측정비용을 최소화하는 절점을 제안하였으며, 이는 상수관망 유지 관리를 위한 압력 계측기 위치 결정목적과는 다소 차이가 있다. 본 연구에서 제안된 방법은 특정 절점에서의 유량변화에 의한 다른 절점에서의 압력변화를 정보량인 엔트로피로 정의하여 객관적이고 정량화된 기준을 제시하였다. 절점에서 비정상상태가 발생했을 때 전체 상수관에 미치는 영향 정도를 정량화된 수치인 엔트로피로 나타내며, 또한 각 절점에서 실제적으로 변동하는 압력을 반영하고자 EPANET의 에미터(emitter) 기능을 사용하여 실제 압력변화 패턴을 파악하였다. 최적 압력계 설치 지점은 엔트로피 기준에 의해 전체 시스템으로부터 제공받는 정보량이 가장 큰 절점을 우선으로 설치해야 한다고 제시하였으며, 제안된 모형을 branch형과 loop형 관망에 각각 적용하여 최적 압력 계측 위치를 선정하고 그 결과를 분석하였다. 분석 결과 현재 실무자의 경험적 판단에 의해 계측기를 설치 운영하고 있는 국내의 상수관리 시스템을 고려할 때, 엔트로피 이론을 통해 보다 객관적인 기준으로 상수관망에서의 압력계 설치 우선순위를 운영자에게 제시할 수 있을 것이며, 상수관망에 압력계를 설치하기 위한 효율적인 의사결정 기준으로 활용이 가능할 것으로 판단된다.

최근 용존 유기물 분석 기법 및 자연환경과 수 처리 시스템 내 활용방안 (Advanced Analytical Techniques for Dissolved Organic Matter and Their Applications in Natural and Engineered Water Treatment Systems)

  • 이윤경;허진
    • 한국물환경학회지
    • /
    • 제38권1호
    • /
    • pp.31-42
    • /
    • 2022
  • Dissolved organic matter (DOM), which changes according to various factors, is ubiquitously present from natural environments to engineered treatment systems. Only limited information is available regarding the environmental functions of DOM after bulk analyses are only applied for characterization. In this paper, latest DOM analytical techniques are briefly introduced, which include fluorescence excitation-emission matrix with parallel factor analysis (EEM-PARAFAC), size-exclusion chromatography with an organic carbon detector (SEC-OCD), carbon/nitrogen stable-isotope ratio, and Fourier transform-ion cyclotron resonance-mass spectroscopy (FT-ICR-MS). Recent examples of using advanced analyses to interpret the phenomena associated with DOM occurring in natural and engineered systems are presented here. Through EEM-PARAFAC, different components like protein-like, fulvic-like, and humic-like can be identified and tracked individually through the investigated systems. SEC-OCD allows researchers to quantify different size fractions. FT-ICR-MS provides thousands of molecular formulas present in bulk DOM samples. Lastly, carbon/nitrogen stable-isotope ratio offers reasonable tools for tracking the sources in environments. We also discuss the advantages and weakness of the above-mentioned characterizing tools. Specifically, they focus on single environmental factors (different sourced-DOM and interaction of sediment-pore water) or simple changes after individual treatment processes. Through collaboration with the advanced techniques later, they help the researchers to better understand environmental behaviors in aquatic systems and serve as essential tools for addressing various pending problems associated with DOM.

송배전용 Al-Cu접속 금구의 신뢰도 향상일 관한 연구(I) 알루미늄 및 동의 부식 특성 (Study on the Improvement of the Reliability of Al-Cu Connections in Power Distribution Systems)

  • 하윤철;배정효;김대경;하태현;이현구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.488-490
    • /
    • 2003
  • As aluminum becomes more widely used in power distribution systems, so the corrosion caused by bimetallic contacts of aluminum and copper becomes more serious problem. In particular, the poor contact of the commonly used compression type bimetal connections may bring about the disastrous interruption of the power supply resulted from the increased corrosion within the joints, which is accelerated by the permeation of water and electrolyte into the interface. In this paper, the corrosion characteristics of aluminum and copper are investigated to improve the reliability of Al-Cu connectons.

  • PDF

생물막 세균의 염소소독제에 대한 내성 (Resistance of Biofilm Bacteria to Chlorination)

  • 조재창;박성주;김상종
    • 미생물학회지
    • /
    • 제31권3호
    • /
    • pp.255-260
    • /
    • 1993
  • Enterobacter cloacae 를 이용하여 슬라이드 (slide glass) 와 아연도강관조각 (galvanized-iron coupon) 상에 생물막을 형성시킨 후 부착생장세균의 염소에 대한 내성을 측정한 결과 부유생장세균에 비해 각각 14배와 380배의 내성증가를 나타내었다. 또한 입자에 부착된 세균군집의 경우 부유세균군집에 비해 48배로 내성이 증가되었다. 슬라이드와 아연도강관조각을 수돗물에 75일간 접촉하였을때 각각 $4.75 {\times} 10^{4}$ cfu/$cm^{2}$, $1.12 {\times} 10^5 cfu/cm^{2}$의 생물막이 형성되는 것을 관찰하였다. 따라서 수돗물에서의 장내세균과 종속영양세균 입자에 부착 혹은 흡착되거나 응집된 상태로 존재함으로써 잔류염소에 대한 내성을 가지게 되며, 또한 정수과정에서 염소살균을 피하여 비급수계통으로 유입되면 배급수관 내벽에 생물막을 형성하여 잔류업소에 대한 내성을 가지게 됨으로써 배급수계통에서 생장하는 것으로 판단된다.

  • PDF

Models for drinking water treatment processes

  • Jusic, Suvada;Milasinovic, Zoran;Milisic, Hata;Hadzic, Emina
    • Coupled systems mechanics
    • /
    • 제8권6호
    • /
    • pp.489-500
    • /
    • 2019
  • With drinking water standards becoming more rigorous and increasing demands for additional water quantities, while water resources are becoming more polluted, mathematical models became an important tool to improve water treatment processes performance in the water supply system. Water treatment processes models reflect the knowledge of the processes and they are useful tools for water treatment process optimization, design, operator training for decision making and fundamental research. Unfortunately, in the current practice of drinking-water production and distribution, water treatment processes modeling is not successfully applied. This article presents a review of some existing water treatment processes simulators and the experience of their application and indicating the main weak points of each process. Also, new approaches in the modeling of water treatment are presented and recommendations are given for the work in the future.

라돈방사능농도의 측정을 통한 지진발생 예측에 관한 연구 (A Study of the Prediction of Earthquake Occurrence by Detecting Radon Radioactivity)

  • 김윤신;이철민;이승일
    • 한국환경과학회지
    • /
    • 제12권6호
    • /
    • pp.677-688
    • /
    • 2003
  • The purpose of this study was to predict occurrence of earthquakes in Korea by measuring the concentration of radon radioactivity in the air and in the underground water. Two monitoring systems of radon concentration detection in the air were installed in Seoul, East Coast area, whereas of radon concentration in the underground water in Kyungju area during December, 1999 to June, 2001. The distribution of radon concentration in the air in Seoul is as follows Winter(10.10 $\pm$ 2.81 Bq/㎥), autumn(8.41 $\pm$ 1.35 Bq/㎥), summer(5.83 $\pm$ 0.05 Bq/㎥) and spring (5.34 $\pm$ 0.44 Bq/㎥), whereas the distribution of radon in the air in the East Coast area showed some difference as follows : autumn (14.08 $\pm$ 5.75 Bq/㎥), Summer (12.04 $\pm$ 0.53 Bq/㎥), Winter (12.02 $\pm$ 1.40 Bq/㎥) and spring (8.93 $\pm$ 0.91 Bq/㎥). In the meanwhile, the distribution of radon in the water is as follows : spring (123.59 $\pm$ 16.36count/10min), Winter (93.95 $\pm$ 79.69counter/10min), autumn (68.96 $\pm$ 37.53counter/10min) and spring (34.45 $\pm$ 9.69counter/10min). The daily range of the density of radon concentration in Seoul and East Coast area was between 5.51 Bq/㎥ - 9.44 Bq/㎥, 7.15 Bq/㎥ - 15.27 Bq/㎥, respectively. Correlation of the distributions of radon concentrations in the air and in underground water with earthquake showed considerable variations of radon concentration before the occurrence of the earthquake. The results suggested that radon radioactivity seemed to be helpful for the prediction of the occurrence of earthquake.

상수관망해석을 위한 도학의 적용 (Applications of Graph Theory for the Pipe Network Analysis)

  • 박재홍;한건연
    • 한국수자원학회논문집
    • /
    • 제31권4호
    • /
    • pp.439-448
    • /
    • 1998
  • 대규모의 배수관망 시스템에서 유량해석을 위한 기법들이 많이 있지만 가장 널리 사용되고 있는 기법은 선형화 기법이다. 이 방법은 연속방정식과 에너지 방정식을 연립하여 해석하므로 이론적으로는 간단하나 실제 시스템에 적용을 위해서는 연립방정식 해석시 생성되는 계수매트릭스의 대각행력에 '0'이 발생하는 등 매우 큰 이산화된 계수 매트릭스의 처리가 문제가 되었다. 본 연구에서는 ill-condition 계수매트릭스의 발생을 배제하기 위해 도학이론으로부터 선형독립적인 폐합회로를 찾는 기법을 상수관망해석에 적용하여 선형화기법의 positive-definite 계수매트릭스를 만드는 기법을 개발하였다. 개발된 알고리듬의 적용성을 시험하고자 22개 가상관로 및 142개 관로를 가진 대구 인근의 실제 관망자료를 이용하여 유량해석을 실시하였다. 유량해석 결과 본 알고리듬이 적용된 모형에서는 가상관망 및 실제관로에서 수렴의 실패없이 원활하게 계산이 이루어지고 있었다. 본 연구결과는 관로내 정상상태 유량해석을 위해 효율적으로 이용될 것이 기대된다.

  • PDF

상수관망에서의 밸브에 의한 관의 부분적 격리와 상수관망의 효율성 평가 (Isolating Subsystems by Valves in a Water Distribution System and Evaluating the System Performance)

  • 전환돈
    • 한국수자원학회논문집
    • /
    • 제38권7호
    • /
    • pp.585-593
    • /
    • 2005
  • 최근의 상수관망의 안전도 확보, 부가적 용수공급로 확보, 그리고 관(管)내 배수를 위한 부분적인 상수관망의 격리문제가 대두 되면서 이를 위한 밸브역할의 중요성이 인식되고 있다. 기본적인 상수관망에서의 밸브역할은 물의 흐름과 압력조절 그리고 관 파괴와 오염물 확산시 부분적 관의 격리라고 할 수 있다. 이중 본 논문에서는 관의 격리 기능을 중심으로 밸브를 해석한다. 관의 파괴로 인한 부분적인 상수관망의 격리시에 일반적으로 그 관만이 아닌 주변의 다른 관들도 함께 격리가 될 수 있으며 이것은 격리하고자하는 관에 설치된 밸브배치에 따라 달라진다. 본 논문에서는 밸브의 배치에 따라 함께 격리되는 관들을 하나의 단위로 보며 이것을 "Segment"라 부른다. Segment에 따라 실제 격리되는 관의 범위가 주어지며 이것에 따라 전체 상수관망을 나눈 후 각 밸브의 중요도와 상수관망의 효율성 평가에 이용한다. 효율성 평가를 위해 7개의 효율성 지수를 제안하며 실제 상수관망에 적용하여 사용성을 검증한다.