• Title/Summary/Keyword: Water Distribution

Search Result 6,900, Processing Time 0.039 seconds

Characterization on the Variation of Streamflow at the Unit Watershed for the Management of Total Maximum Daily Loads - in Guem River Basin - (수질오염총량관리 단위유역의 유량변화 특성분석 - 금강수계를 대상으로 -)

  • Park, Jun Dae;Oh, Seung Young;Choi, Ok Youn
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.914-925
    • /
    • 2011
  • The variation of streamflow is regarded as one of the most influential factors on the fluctuation of water quality in the stream. The characteristics of the variation should be taken into account in the plans for the management of Total Maximum Daily Loads (TMDLs). This study analysed and characterized spatial distribution and temporal variation of streamflow at each unit watershed in Guem-river basin. For the analysis of the distribution of streamflow, the type and the extent of the distribution were investigated for the unit watershed. For the analysis of the variation, short and long term changes of streamflow were examined. The result showed that most of the distributions were not log-normalized and the extent of variation tends to be greater at the unit watershed placed on the tributaries in the basin. A kind of margin could be granted to the unit watershed involving high variations so as to establish the water quality goal and load allotment more reasonably and effectively in view of whole waterbody.

The Estimation of Probability Distribution by Water Quality Constituents Discharged from Paddy Fields during Non-storm Period (영농형태별 영농기간 동안 비강우시 논 유출수의 수질 항목별 확률분포 추정)

  • Choi, DongHo;Hur, Seung-Oh;Kim, Min-Kyeong;Yeob, So-Jin;Choi, Soon-Kun
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Analysis of water quality distribution is very important for river water quality management. Recently, various studies have been conducted on the analysis of water quality distribution according to reduction methods of nonpoint pollutant. The objective of this study was to select the probability distributions of water quality constituents (T-N, T-P, COD, SS) according to the farming forms (control, slow release fertilizer, water depth control) during non-storm period in the paddy fields. The field monitoring was conducted monitoring site located in Baeksan-myun, Buan-gun, Jeollabuk-do, Korea during non-storm period from May to September in 2016. Our results showed that there were no differences in water quality among three different farming forms, except for SS of control and water depth control. K-S method was used to analyzed the probability distributions of T-N, T-P, COD and SS concentrations discharged from paddy fields. As a results of the fitness analysis, T-N was not suitable for the normal probability distribution in the slow release fertilizer treatment, and the log-normal probability distribution was not suitable for the T-P in control treatment. The gamma probability distribution showed that T-N and T-P in control and slow release fertilizer treatment were not suitable. The Weibull probability distribution was found to be suitable for all water quality constituents of control, slow release fertilizer, and water depth control treatments. However, our results presented some differences from previous studies. Therefore, it is necessary to analyze the characteristics of pollutants flowing out in difference periods according to various farming types. The result of this study can help to understand the water quality characteristics of the river.

On the Distribution of Water Temperature in the Warm Water Pool. -On the Wudu Warm Water Pool- (온수지에서의 수온분포에 관한 연구 -우두온수지를 중심으로-)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.121-126
    • /
    • 1979
  • The objective of this study was to grasp the condition of the distribution of water temperature in the warm water pool, and these observations were performed in Wudu warm water pool located at Wodu-Dong in Chuncheon. The results summarized in this study are as follows; 1. The horizontal distribution charts of water temperature at each depth of points were shown as Fig. 3, Fig. 4, and Fig. 5, respectively. In consequence of the observation, the condition of warm water was stagnant in the coner of warm water pool. As the result, it was found out that stagnant condition was the heaviest at water surface (depth; 0.05m), more heavier at middle depth (depth; 0.55m) and some heavy at bottom of the pool (depth; 1.10m). 2. The vertical water temperature change was shown as Fig. 6, and the mean water temperature of water surface (depth;0.05m) was higher about $2.2{\sim}3.3^{\circ}C$ than bottom water temperature. 3. Therefore, it was required to device such structures as form of broad cannels or overflow diversion weirs to mingle with top and bottom water.

  • PDF

Distribution of Air-Water Two-Phase Flow in a Flat Tube Heat Exchanger (평판관 열교환기 내 공기-물 2상류 분지)

  • Kim, Nae-Hyun;Park, Tae-Gyun;Han, Sung-Pil;Shin, Tae-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.687-697
    • /
    • 2006
  • The air and water flow distribution are experimentally studied for a heat exchanger composed of round headers and 10 flat tubes. The effects of tube protrusion depth as well as mass flux, and quality are investigated, and the results are compared with the previous 30 channel results. The flow at the header inlet is annular. For the downward flow configuration, the water flow distribution is significantly affected by the tube protrusion depth. For flush-mounted geometry, significant portion of the water flows through frontal part of the header. As the protrusion depth increases, more water is forced to the rear part of the header. The effect of mass flux or quality is qualitatively the same as that of the protrusion depth. Increase of the mass flux or quality forces the water to rear part of the header. For the upward flow configuration, different from the downward configuration, significant portion of the water flows through the rear part of the header. The effect of the protrusion depth is the same as that of the downward flow. As the protrusion depth increases, more water is forced to the rear part of the header. However, the effect of mass flux or quality is opposite to the downward flow case. As the mass flux or quality increases, more water flows through the frontal part of the header. Compared with the previous thirty channel configuration, the present ten channel configuration yields better flow distribution. Possible explanation is provided from the flow visualization results.

Development of optimum pump operation technique for the damage rate reduction of water distribution system (상수도관망의 피해율 저감을 위한 가압장 최적운영기법 개발)

  • Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.5
    • /
    • pp.373-380
    • /
    • 2019
  • In this study, the optimum pump operation technique is suggested to decrease the damage rate of water distribution system. Pump operation system was developed to achieve the effective pump operation. Pressure sensors which can communicate with pumps are installed at the end of water distribution system. Pump operation system can control the pressure of water pump according to data sent from the pressure sensors. Therefore, water distribution system can reduce the pressure and maintain enough pressure which can supply the demand of water users. For proving effectiveness of new system, reliability model was introduced to compare the results of damage rates between the maintaining high pressure and selective pressure in water pump. Unsteady analysis was conducted with several scenarios. And the results were used to calculate the probability of pipe breakage. From the results, it was found that new pump operation system can reduce the energy usage and probability of pipe breakage by applying to pumps.

The Variation of the Urban Water Use and the Distribution Reservior Capacity with Time for a Day (상수도(上水道)의 1일(日) 급수량(給水量) 및 배수지(配水池) 용량(容量) 변화(變化)에 관한 연구(硏究))

  • RHEE, Kyoung Hoon;PARK, Sung Chun;MOON, Byoung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.9 no.2
    • /
    • pp.118-126
    • /
    • 1995
  • The variation of the urban water demand and the amount of water in the distribution reservoir was studied with time for a day. The city of Kwangju in Korea was selected as a study area. The population of Kwangju in the end of 1993 was more than one million and two hundred thousand peoples. The average of daily water use in 1993 was about three hundred and fifty thousand tons a day. One day was devided into 12 divisions with a 2 hour increment. The water use demand related to the amount of water in the distribution reservoir was observed for the given time interval of a day. The water use index was defind in percentage that indicates the ratio of the amount of water use for a time interval to the amount of water use for a day. The water use index with consideration of the water stored in the reservoir was found to be useful to manage and to operate the water supply systems in real time.

  • PDF

A Study on Hydraulic Pressure Change Characteristics of Water Distribution Networks in Large Cities (대도시 급배수관망의 수압변화 특성에 관한 연구)

  • Oh, Chang-Ju;Kim, Tae-Kyoung;Rhee, Kyoung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.279-287
    • /
    • 2005
  • In this study, I suggest an effective operation of waterwork facilities in large cities and a scientific method for utilizing water in water distribution systems. To achieve this goal, my simulation were carried out on data from Kwangju City using Pipenet '98, a pipe-network program. From this simulation, I examine the possibilities of application the system in large cities, comparing data measured at 33 hydraulic pressure monitoring places from waterwork enterprises. The result is coincident with that of waterwork enterprises, with about a 12.5% average error rate and $0.32kg/cm^2$ average deviation. The method and program I use here can be helpful in cities where there is a need to extend the waterwork facilities, or where there is a need to suspend the water supply, and/or there is an accident. The simulation shows how to expand waterwork facilities effectively, how to prevent accidents, and how to estimate the hydraulic pressure even in the areas without monitoring places.

Implementation of the Calculation Method for 95% Upper Limit of Effluent Water Quality of Sewage Treatment Plant for Total Maximum Daily Loads : Percentile Ranking Method (수질오염총량관리를 위한 환경기초시설 배출수질의 통계적 평가방법 개선 : 선형보간법의 백분위수방법)

  • Park, Jae Hong;Kim, Dong Woo;Oh, Seung-Young;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.676-681
    • /
    • 2008
  • The evaluation of the effluent water quality of sewage treatment plant is one of the most important factor in calculating total maximum daily loads (TMDLs). Current method to calculate 95% upper limit of effluent water quality of sewage treatment plant assuming normal distribution of data needs to be implemented in case of non-normal distribution. We have investigated the applicability of percentile ranking method as a non-parametric statistical analysis in case of non-normal distribution of data.

Monitoring of hot waste water spread from coastal power station by the Landsat TM images (확산의 모니터링)

  • Cheoi, Seung-Pil;Yang, In-Tae;Lee, Kee-Boo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.1 s.11
    • /
    • pp.105-116
    • /
    • 1998
  • The spreading of hot waste water discharged from the coastal power station is a new problem to marin e circumstances and the fishery. Because the survey of hot waste water discharges should be performed is multaneously across wide areas, it is very difficult. Some sensors of the Landsat can draw the spread and distribution of water temperature from wavelength range of thermal infrared. The present study applied the GIS after stretching DN for the purpose of drawing a more accurate distribution of water temperature. Accordingly, the pattern of water temperature distribution could be expressed more precisely for a broad area, and the spread and distribution of hot waste water could be analyzed economically.

  • PDF

Simulation study on porosity disturbance of ultra-large-diameter jet borehole excavation based on water jet coal wetting and softening model

  • Guo, Yan L.;Liu, Hai B.;Chen, Jian;Guo, Li W.;Li, Hao M.
    • Geomechanics and Engineering
    • /
    • v.30 no.2
    • /
    • pp.153-167
    • /
    • 2022
  • This study proposes a method to analyze the distribution of coal porosity disturbances after the excavation of ultra-large-diameter water jet boreholes using a coal wetting and softening model. The high-pressure jet is regarded as a short-term high-pressure water injection process. The water injection range is the coal softening range. The time when the reference point of the borehole wall is shocked by the high-pressure water column is equivalent to the time of high-pressure water injection of the coal wall. The influence of roadway excavation with support and borehole diameter on the ultra-large-diameter jet drilling excavation is also studied. The coal core around the borehole is used to measure the gas permeability for determining the porosity disturbance distribution of the coal in the sampling plane to verify the correctness of the simulation results. Results show that the excavation borehole is beneficial to the expansion of the roadway excavation disturbance, and the expansion distance of the roadway excavation disturbance has a quadratic relationship with the borehole diameter. Wetting and softening of the coal around the borehole wall will promote the uniform distribution of the overall porosity disturbance and reduce the amplitude of disturbance fluctuations.