• 제목/요약/키워드: Water Distribution

검색결과 6,900건 처리시간 0.04초

Application of Management Reliability Index for Water Distribution System Assessment

  • Choi, Taeho;Lee, Sewan;Kim, Dooil;Kim, Mincheol;Koo, Jayong
    • Environmental Engineering Research
    • /
    • 제19권2호
    • /
    • pp.117-122
    • /
    • 2014
  • Indexes of safety, restoration, damage impact, and management reliability were developed to assess reliability of drinking water distribution networks (DWDNs) management. The developed indexes were applied to evaluate the reliability of the pipeline management stage during unexpected mechanical and hydraulic accidents of components. The results were used to support the decision-making process in effective management and maintenance by enhancing the administrator's system understanding and by helping to create appropriate maintenance and management policies. The results of this study indicated that application of a management reliability index to assess DWDNs reliability may help create a more effective plan for establishing DWDNs management and maintenance.

Estimation of water quality distribution in freshing reservoir by satellite images

  • Torii, Kiyoshi;You, Jenn-Ming;Chiba, Satoshi;Cheng, Ke-Sheng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1227-1229
    • /
    • 2003
  • Kojima Lake in Okayama prefecture is a freshing reservoir constructed adjacent to the oldest reclaimed land in Japan. This lake has a serious water quality problem because two urban rivers are flowing into it. In the present study, unsupervised classification was performed at intervals of several years using Landsat MSS data in the past 15 years. After geometric correction of these data, MSS data corresponding geographically to the field observation data were extracted and subjected to the multivariate analysis. Water quality distribution in the lake was estimated using the regression equation obtained as a result. In addition, two - dimensional and three-dimensional numerical simulations were performed and compared with the distribution obtained from the satellite images. Behavior of the reservoir flows is complicated and water quality distribution varies greatly with the flows. Here, I report the results of analysis on three factors, field observation, numerical simulation and satellite images.

  • PDF

경천가뭄지역 농업용수 공급량의 수로손실 분석 (Analysis of Channel Water Loss of the Agricultural Water Supply in a Gyeongcheon Drought Area)

  • 조건호;문진경;최경숙
    • 한국농공학회논문집
    • /
    • 제62권2호
    • /
    • pp.53-62
    • /
    • 2020
  • The purpose of this study is to estimate the channel water loss of agricultural water supply in the command areas belong to Yechon irrigation channel of Gyeongcheon reservoir located Mungyeong-si, which area experienced a severe drought in 2015. The channel water loss was estimated by comparison of the irrigation water requirements (IWR) and agricultural water supply of the field data from 2012 to 2015. Further analysis was conducted to define the conveyance loss estimated based on the leakage holes and illegal pumping spots investigated through the field survey, and the distribution loss obtained by subtracting conveyance loss from the channel water loss. The annual rainfall decreased gradually, but the contribution of effective rainfall, available rain water to crop, increased to IWR during the study period. These phenomena resulted in the increase of agricultural water supply, and hence made greater the channel water loss simultaneously. The average channel water losses estimated as 36.8 % with 7.1 % of the conveyance loss and 29.7 % of distribution loss respectively. The distribution loss seems to be related to total number of rainy days, and irrigation schedules, while the conveyance loss was caused by irrigation channel aging conditions and illegal intake problems. In order to achieve sustainable agricultural water resources, the channel water loss needs to be reduced through the restoration of aged irrigation facilities and effective water managements in the fields.

X 선 영상기법을 이용한 고분자 전해질형 연료전지의 수분분포 가시화 (Visualization of Water Distribution in a Polymer Electrolyte Fuel Cell Using an X-ray Imaging Technique)

  • 임남윤;박구곤;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.155-158
    • /
    • 2007
  • Water management for Polymer Electrolyte Fuel Cell (PEFC) has been receiving large attention as an important issue in practical applications. Proper water management is vital to achieve high performance and durability of PEFC. In this study, an X-ray imaging technique was employed to visualize the water distribution in a PEFC quantitatively. X-ray images of the PEFC components with and without water are distinguished clearly. From the visualized X-ray images, we could confirm the water distribution in the region between separator and gas diffusion layer (GDL). In addition, the contact angle of water in the micro-channels was also clearly visualized..

  • PDF

내부 온도분포를 고려한 Coal-Water Slurry의 점화현상에 관한 이론적 해석 (Theoretical Analysis of Ignition of a Coal-Water Slurry Droplets with Interior Temperature Distribution)

  • 최창은;백승욱;김종욱
    • 대한기계학회논문집
    • /
    • 제17권7호
    • /
    • pp.1823-1832
    • /
    • 1993
  • CWS(coal-water slurry) is used for application in power plants, boilers, industrial furnaces. A single coal-water slurry droplet ignition has been examined to reveal the basic nature of their evaporation, volatilization and heating processes. The interior droplet temperature distribution has been considered. The effect of coal thermal conductivity, droplet size, water fraction in the slurry, gas temperature and velocity and radiation on the ignition phenomena were also studied. Either increasing the velocity and gas temperature or decreasing the droplet size and water fraction in the slurry may reduce the time for evaporation and ignition delay time.

X선 영상기법을 이용한 고분자 전해질형 연료전지의 수분분포 가시화 (Visualization of Water Distribution in a Polymer Electrolyte Fuel Cell Using an X-ray Imaging Technique)

  • 임남윤;박구곤;김창수;이상준
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.33-38
    • /
    • 2007
  • Water management in polymer electrolyte fuel cell (PEFC) has been receiving large attention as an important issue in practical applications. Proper water management is vital to achieve high performance and durability of PEFC. In this study, an X-ray imaging technique was employed to visualize the water distribution in a PEFC quantitatively. X-ray images of the PEFC components with and without water were distinguished clearly. From the visualized X-ray images, we could evaluate the water distribution in the region between separator and gas diffusion layer (GDL) quantitatively. In addition, the contact angle of water in the micro-channels was also clearly visualized.

다점주입계(多点注入系) 배수관망(配水管網)에 미치는 상수수요형태(上水需要形態)의 영향(影響) (Effect of Water Demand Patterns on the Water Distribution System with Multi-Reservoirs)

  • 현인환;위욱량;이상준
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.51-58
    • /
    • 1997
  • Determining sizes and the locations of reservoirs in the water distribution system(WDS) with multi-reservoirs is much difficult than that with single reservoir. The extended period simulation(EPS) models provide more comprehensive analysis of water distribution systems than the steady-state models can do. Therefore, EPS models should be applied to the WDS with multi-reservoirs. This study is to investigate the variations of required reservoir sizes and residual nodal pressures according to reservoir locations. In this study, EPS was applied to analyze an artificial and a real WDS under several water demand patterns. As a result, it was found that water demand patterns make no significant differences in the determining of the reservoir size, if they have similar peaking factors. And the variations of the peaking factor should be carefully checked in the design and the analysis of the WDS with multi-reservoirs, because the peaking factor itself will affect the minimum allowable sizes of reservoirs in those systems.

  • PDF

요인실험계획을 이용한 수도관 생물막 형성 영향 인자의 효과 분석 (Analysis of Effects of Factors Influencing Biofilm Formation in Drinking Water Distribution Pipe Using Factorial Experimental Design)

  • 박세근;최성찬;김영관
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.181-192
    • /
    • 2005
  • This study evaluated the effect of factors influencing the initial biofilm formation in drinking water distribution pipe by running experiments using a $2^{4-1}$ fractional factorial experimental design with a replicate. Important variables used for assessing biofilm formation included BDOC(biodegradable dissolved organic carbon), viable heterotrophic bacteria present in drinking water, water temperature, and shear stress at two levels each. Based on the statistical analysis of biofilm levels measured as attached HPC(heterotrophic plate count) and community-level assay, the main factors that have significant effects on biofilm formation were found to be viable heterotrophic bacteria and BDOC. Water temperature only exhibited significant effect on the levels of attached HPC, while shear stress was not a significant factor under given conditions. Moreover, the statistical analysis revealed that interactions between the important variables were not statistically significant at a 0.05 significance level.

Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation

  • 장영철;정권
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권6호
    • /
    • pp.1114-1119
    • /
    • 2004
  • The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg $Cl_2/l$. An additional aspect of the current study was that the potential of the exoproteolytic activity (PEPA) technique was used along with a traditional so-called destructive technique in which the biofilm was scrapped off the coupon surface, resuspended, and cultivated on an R2A agar. Both techniques indicated similar trends and relative comparisons among the PDSs, yet the culturable biofilm values for the traditional method were several orders of magnitude lower than the PEPA values.

상수도용 도복장강관의 용접 및 외부하중에 의한 응력 특성에 관한 연구(I) - 후열처리에 의한 용접부의 잔류응력 특성 - (A Study on the Stress Distribution of Steel Water Pipes(I) - Characteristics of Residual Stress Distribution by PWHT -)

  • 윤석환;이승기;나석주;고명환
    • Journal of Welding and Joining
    • /
    • 제19권3호
    • /
    • pp.285-291
    • /
    • 2001
  • Large steel water pipes are joined prevalently by the bell end method, and are welded both at inside and outside of lapped parts. In practice, welded joints of water pipes are very critical, because in most cases failure of pipes causing leakage occurs at the welded joint. Therefore some methods have been developed to ensure the soundness of welded joints of water pipes, like leakage tests and nondestructive tests (NDTs). But one of the major characteristics that affects the soundness of welded Joints is the stress distribution caused by welding and external forces. Some studies have been carried out on the residual stress of steel water popes, but complex stress distributions by welding and external forces are rarely studied. In this study, temperature and stress distributions in steel water pipes produced by welding are predicted by a three-dimensional finite element method(FEM). Also, stress values are measured from real steel water pipes by the hole-drilling methods, and compared with predicted ones. The influence of some typical post weld treatments on residual stress distribution was also investigated by residual stress measurements.

  • PDF