태양에너지 해수담수화를 위한 3중 효용 증발식 담수기 개발 (Development of 3th Effects Evaporative desalination system for Solar Desalination System)

  • 황인선;주홍진;윤응상;곽희열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.201-201
    • /
    • 2010
  • The evaporative desalination system with solar energy would be the efficient and attractive method to get fresh water. This study was described the development of Multi Effect Distillation(MED) with solar energy desalination system. The system was designed and manufactured Multi effect distillation on the capacity of $3m^3$/day. The experimental apparatus consists mainly of ejector pump, Hot water pump, flow meter, demister, cooler, evaporator and condenser. Evaporator and condenser were made Shell&Tube Heat Exchanger type with corrugated tube. The experimental variables were chosen $75^{\circ}C$ for hot water inlet temperature, 40, 60 and $80{\ell}$/min for hot water inlet volume flow rate, 6.0 and $8.0{\ell}$/min for evaporator feed seawater flow rate, $18^{\circ}C$ for sea water inlet temperature to cover the average sea water temperature and the salinity of sea water is measured about 33,000 PPM (parts per million). for a year in Korea. This study was analyzed the results of thermal performance of Multi Effect Distillation. The results are as follows, The experimental Multi effect distillation is required about 40 kW heat source for production of $3m^3$/day fresh water. Various operating flow rate was confirm in the experiments to get the optimum design data and the results showed that the optimum total flow was $8.0{\ell}$/min. Comparison of Single Effect Distillation with Multi Effect Distillation showed MED is at least more than double of SED.

  • PDF

강변여과수 시설에서의 지열에너지 활용 가능성 평가 (Assessment for geothermal energy utilization in the riverbank filtration facility)

  • 신지연;김경호;배광옥;이강근;정우성;석희준;김형수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.485-488
    • /
    • 2007
  • Riverbank filtration is a kind of artificial aquifer recharge for the fresh water supply. By construction of several production wells penetrating the riverbank, surface water withdrawn from the river would pass riverbed. This extracted water is well known to be cooler than surface water in summer and warmer than surface water in winter, showing more constant water temperature. This characteristic of extracted water is applied to geothermal energy utilization. Prediction of the annual temperature variation of filtrated water is the major concern in this study. In Daesan-myeon, Changwon-si, Gyeongsangnam-do, South Korea, riverbank filtration facility has been on its operation for municipal water supply and thermal energy utilization since 2006. Appropriate hydraulic and thermal properties were estimated for flow and heat transfer modeling with given pumping rate and location. With the calibrated material properties and boundary conditions, we numerically reproduced measured head and temperature variation with acceptable error range. In the numerical simulation, the change of saturation ratio and river stage caused by rainfall was calculated and the resulting variation of thermal capacity and thermal conductivity was considered. Simulated temperature profiles can be used to assess the possible efficiency of geothermal energy utilization using riverbank filtration facility. Influence of pumping rate, pumping location on the extracted water temperature will be studied.

  • PDF

도시의 수목이 기온의 조절에 미치는 영향 (Influences of Urban Trees on the Control of the Temperature)

  • 김수봉;김해동
    • 한국조경학회지
    • /
    • 제30권3호
    • /
    • pp.25-34
    • /
    • 2002
  • The purpose of this paper is to discuss the function of microclimate amelioration of urban trees regarding the environmental benefits of street trees in summer, focusing on the heat pollution-urban heat island, tropical climate day's phenomenon and air pollution. We measured the diurnal variation of air/ground temperatures and humidity within the vegetation canopy with the meteorological tower observation system. Summertime air temperatures within the vegetation canopy layer were 1-2$^{\circ}C$ cooler than in places with no vegetation. Due to lack of evaporation, the ground surface temperatures of footpaths were, at a midafternoon maximum, 8$^{\circ}C$ hotter than those under trees. This means that heat flows from a place with no vegetation to a vegetation canopy layer during the daytime. The heat is consumed as a evaporation latent heat. These results suggest that the extension of vegetation canopy bring about a more pleasant urban climate. Diurnal variation of air/ground temperatures and humidity within the vegetation canopy were measured with the meteorological tower observation system. According to the findings, summertime air temperatures under a vegetation canopy layer were 1-2$^{\circ}C$ cooler than places with no vegetation. Due mainly to lack of evaporation the ground surface temperature of footpaths were up to 8$^{\circ}C$ hotter than under trees during mid-afternoon. This means that heat flows from a place where there is no vegetation to another place where there is a vegetation canopy layer during the daytime. Through the energy redistribution analysis, we ascertain that the major part of solar radiation reaching the vegetation cover is consumed as a evaporation latent heat. This result suggests that the expansion of vegetation cover creates a more pleasant urban climate through the cooling effect in summer. Vegetation plays an important role because of its special properties with energy balance. Depended on their evapotranspiration, vegetation cover and water surfaces diminish the peaks of temperature during the day. The skill to make the best use of the vegetation effect in urban areas is a very important planning device to optimize urban climate. Numerical simulation study to examine the vegetation effects on urban climate will be published in our next research paper.

CA저장고의 작동 환경에 따른 감모율 예측 (Weight Loss Prediction by Operating Conditions of CA Storage)

  • 박천완;박석호;김진세;최동수;김용훈;이수장
    • 산업식품공학
    • /
    • 제21권4호
    • /
    • pp.312-317
    • /
    • 2017
  • 감모율에 영향을 주는 인자를 파악하고 온습도 변화, 제상수, VPD방법을 이용해 감모율을 예측하였으며 실제 감모율과 비교분석을 진행하였다. 저장고 내부의 습도변화를 이용하여 예측한 결과 질소주입과정보다 유닛쿨러의 운전과정에서 발생하는 응축 결상 수분배출 과정이 지배적인 영향을준다. 또한 온습도를 이용한 감모율 예측방법이 실제 감모율과 가장 근사값을 나타냈다. 제상수를 이용해 예측한 결과 감모량은 유닛쿨러의 운전율이 높아질수록 많아졌으며 온습도를 이용한 예측방법보다 운전특성에 따른 감모율 변화가 더 뚜렷하게 나타났다. 이때 유닛쿨러의 운전율은 외기온도와 비례하였으며, 저장고 내부에서 응축된 수분량의 계측이 어렵기 때문에 실제 감모율과 오차가 발생한 것으로 보인다. VPD를 이용한 감모율 예측은 증산계수(K-value)의 영향이 지배적이며, 보고되어진 본 연구에서 이용한 후지사과의 증산계수값(42)에 대한 검증이 필요하다. 본 연구에서 후지사과의 K-value를 30으로 수정하였을 때 가장 근사한 예측값을 계산할 수 있었다.

Hydrographic Structure Along 131.5°W in the Eastern Tropical Pacific in July 2003

  • Chang, Kyung-Il;Hwang, Sang-Chul;Hong, Chang-Su
    • Ocean and Polar Research
    • /
    • 제26권2호
    • /
    • pp.299-309
    • /
    • 2004
  • Conductivity-temperature-depth (CTD) data obtained along a meridional section in the eastern tropical Pacific in July 2003 have been analyzed to identify various water masses, and to examine the hydrographic structure and zonal geostrophic currents in the upper 1000 m. Water mass analysis shows the existence of subtropical and intermediate waters, characterized by layers of subsurface salinity maximum and minimum, originating from both hemispheres of the Pacific. Vertical section of temperature in the upper 200 m shows the typical trough-ridge structure associated with the zonal current system for most of the tropical Pacific. Water with the lowest salinity of less than 33.6 was found in the upper 30 m between $8.5^{\circ}N$ and $10.5^{\circ}N$ in a boundary zone between the North Equatorial Current and North Equatorial Countercurrent. Temporal changes in water properties observed at $10.5^{\circ}N$ over a period of 9 days suggest both the local rainfall and horizontal advection is responsible for the presence of the low-salinity water. Development of a barrier layer was also observed at $10.5^{\circ}N$. In the North Equatorial Current region a local upwelling was observed at $15^{\circ}N$, which brings high salinity and cooler subtropical water to the sea surface. A band of countercurrent occurs in the upwelling region between $13^{\circ}N$ and $15^{\circ}N$.

동결농축법을 이용한 폐수처리시스템의 에너지 효율 향상에 관한 연구 (A study on energy efficiency improvement of waste-water treatment system by freeze concentration method)

  • 김정식;임승택;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권5호
    • /
    • pp.467-476
    • /
    • 2013
  • 동결농축법은 열역학적 효율이 높고 에너지 소비량이 작으며 처리수를 재활용할 수 있는 장점을 가지고 있다. 본 연구에서는 중소규모로 상용화 가능한 동결농축폐수처리시스템을 설계하고, 각 시스템의 에너지 소비효율과 일일처리량을 비교하여 시스템 개발방향을 제안하고자 하였다. 시스템을 완속운전시스템과 급속운전시스템으로 각각 모델링하고 해석을 통해 소비동력과 운전시간을 계산하여 비교한 다음 설계처리량에 따른 변화를 추가 검토하였다. 연구결과 급속운전시스템의 소비전력량비가 0.6 Wh/kg 만큼 다소 높으나 일일처리량은 19 % 증가하였으며, 설계처리량이 큰 시스템일수록 소비전력량비가 작아지고 일일처리량이 큰 결과를 얻었다.

온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성 (Performance Characteristics of a Mixed Refrigerant OTEC Power Cycle Using Hot Waste Water)

  • 윤정인;손창효;허정호;예병효;김현주;이호생
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.102-107
    • /
    • 2013
  • In this paper, the performance analysis for evaporation capacity, total work and efficiency of the ocean thermal energy conversion(OTEC) power system using mixed refrigerant(R32,R152a) is conducted to find the effect of hot wasted water on OTEC power system. The system in this study is applied with two stage turbine, regenerator, cooler and separator on Organic Rankine Cycle. The commercial program HYSYS is used for the performance analysis. The main results were summarized as follows : The efficiency of the OTEC power cycle has a largely effect on the evaporation capacity and total work. As increasing temperature of heat source water, evaporator's capacity is decreased but total work increase. Otherwise, using hot wasted water bring effects not only increasing system efficiency but also declining evaporator's capacity. Thus With a thorough grasp of these effect, it is necessary to find way to use hot wasted water emitted by power plant and so on.

2007년 하계 및 추계 경상북도 후포연악역 물리적 해황특성 (Physical Oceanographic Characteristics in Hupo Coastal area during Summer and Autumn, 2007)

  • 황재동;이용화;심정민;윤석현;진현국;김영숙;권기영;윤상철
    • 한국수산과학회지
    • /
    • 제41권6호
    • /
    • pp.505-510
    • /
    • 2008
  • To understand the oceanographic characteristics of Hupo coastal waters as regards the East Korean Warm Current and the North Korean Cold Current, current direction and velocity were investigated by deploying a current meter in Hupo coastal waters during the summer and fall of 2007. Wind data were obtained from the homepage of the Korea Meteorological Administration. Water temperature was measured using a temperature meter attached to the current meter and a mini log. During summer, a south wind prevailed, while during the fall the wind blew from the north. Cold surface waters occurred on a large scale in summer, while in the fall, warm bottom water occurred frequently. After mid-November, when the surface water was cooler than $15^{\circ}C$, there was no difference in water temperature between the surface and bottom layers.

한국기계연구원의 열유체환경기술 개발현황 (R&D on Thermal, Fluid, and Environmental Engineering Technology in KIMM)

  • 김석준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.17-24
    • /
    • 2001
  • To solve the problems of energy and environment conservation issued recently, mainly in mechanical engineering point of view, R&D's on the thermal, fluid and environmental engineering technology have been carried out by two R&D departments in the Korea Institute of Machinery & Materials (KIMM). Now there are 65 researchers in the two. The representative projects in the field of thermal and fluid engineering are development of an inactive gas generator and development of a cryogenic cooler for electronic sensors. Pyrolysis and melting of wastes, gas treatment using nonthermal plasma, and desalination are important technology to be developed in environmental R&D areas. To reduce the emission from the existing diesel engines for buses, an LPG direct injection type of bus engine is being developed supported by LPG supply companies. These several R&D projects which have been carried out in KIMM are introduced briefly.

  • PDF

냉동기 고장경향분석을 통한 설비신뢰도향상 방안 제시 (The Suggestion of Reliability Improvement Method based on Failure Trend Analysis of Chiller)

  • 이상대;염동운;현진우
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.251-255
    • /
    • 2015
  • Chiller system plays an important role of maintaining room temperature constantly by supplying chilled water to Heating, Ventilating and Air Conditioning(HVAC)or area room cooler equipment during plant normal operation or accident condition. Chiller failures are one of the most frequently occurring equipment failures. If the types of chiller failures are analyzed and grouped thoroughly, it would be helpful to make chiller maintenance strategy at the plants. That would enhance equipment reliability of chiller in the end. In this paper, chiller failure data during three years were analyzed and categorized by specific failure code. In addition, the various proposals to improve equipment reliability of chiller were suggested such as Preventive Maintenance Optimization(PMO) strategy and performance monitoring reinforcement and so on.