• 제목/요약/키워드: Water Concentration

검색결과 11,852건 처리시간 0.046초

액상 비료를 유도 용액으로 사용하는 정삼투 기반의 해수 담수화 (Forward Osmosis Based Seawater Desalination using Liquid Fertilizer as Draw Solution)

  • 박성직;안희경
    • 한국농공학회논문집
    • /
    • 제55권2호
    • /
    • pp.21-27
    • /
    • 2013
  • The present study explored the way to desalinate seawater for agricultural irrigation using forward osmosis (FO) process using liquid fertilizer as draw solution. FO experiments were performed in a cross flow mode using flat sheet FO membrane. The effect of membrane orientation, flow rate, and draw solution concentration on the performance of forward osmosis was investigated by measuring water flux of forward osmosis membrane. The water flux when the draw solution was placed against the membrane active layer was lower than the water flux when the feed solution was placed against the membrane active layer. This results indicated that the decrease of effective osmotic pressure by dilutive internal concentration polarization was less than that by concentrative internal concentration polarization. Increasing flow rate from 66.7 to 133.1 $cm^3$/min resulted in increase of the water flux when the membrane active layer orient to draw solution and feed solution, respectively. The reduction of resistance to water flow increased water flux at higher flow rate. The water flux of FO membrane increased with increasing draw solution concentration from 10000 to 30000 mg/L. The water flux for $KH_2PO_4$ draw solution was similar to that for commercial fertilizer. Optimization of FO process would contribute to economically desalinate brackish water for agricultural use.

도시 일부지역에서의 실내 라돈농도에 관한 연구 (A Study on Indoor Radon Concentrations in Urban Area)

  • 김순애;백남원
    • 한국환경보건학회지
    • /
    • 제28권2호
    • /
    • pp.89-98
    • /
    • 2002
  • This study was taken in general hospital, hotel, shopping center, underground cafe, school, house, for the purpose of investigating the distribution of indoor radon concentration in urban area, by E-PERM which approved U.S. EPA, between August and November 1999. There are two sampling Places were exceed 148 ㏃/㎥(4 pCi/L; U.S EPA remedial level), difference mean is 24.0㏃/㎥ when compared with underground vs. aboveground indoor radon concentration in the same building and ratio is 1.6, so underground area is higher than aboveground (p<0.05). Influencing factors were examined. They related to the location of sampler(detector) open or near the door is lower radon concentration than inside portion, which explains probably open area has better ventilated air and dilutes indoor radon concentration. Temperature has a negative relationship (p<0.05) with indoor radon concentration and relative humidity has a positive (p<0.05) Simultaneously to investigate water radon concentration, collected piped-water and the results were very low, which is the same in piped-water concentration other countries. In conclusion, underground indoor radon concentration is higher than aboveground. Concentration was related to sampling spot, open portion is lower than inside. Higher the temperature, lower the indoor radon concentrations. On the other hand higher the relative humidity, higher the indoor radon concentrations. Indoor radon concentration is influenced by sampling point, temperature, relative humidity.

고도정수처리공정에서 오존의 유기물 분해능 (Decomposition of Organic Matters by Ozonation in Advanced Water Treatment Process)

  • 윤태경;이강춘;노병일
    • 한국환경과학회지
    • /
    • 제14권3호
    • /
    • pp.327-333
    • /
    • 2005
  • The performance of ozone contactor in ozone-BAC advanced water treatment process was evaluated by the degree of decomposition of organic matters. The degree was measured by the analyses of $UV_{254}$ absorbance and the concentrations of DOC and BDOC for the sand filtered water and the ozone treated water, respectively. In addition, the ozone concentration in the contactor, required for the maximum BDOC concentration, was selected as the optimum concentration, and the appropriate residential time of ozone treated water in a reservoir was recommended based on the residual ozone concentration in the treated water. The following results were obtained from the pilot scale experiments. By ozonation $UV_{254}$ absorbance was decreased, and BDOC concentration was increased. The change of DOC concentration by ozonation was negligible, but the excess input of ozone resulted in the removal of the small amount of BDOC by complete oxidation. The optimum ozone concentration was 0.58mg $O_3/mg$ DOC. In order to remove residual ozone, 20minutes of the residential time were enough after ozonation.

시멘트경화체의 반투과성에 의한 수분이동에 미치는 용액농도와 환경온도의 영향 (Effect of Concentration of Solution and Temperature on Water Flux by Semi-Permeability of Hardened Cement Paste)

  • 배기선;오상근;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.131-136
    • /
    • 1997
  • It is well known that concrete is typical porous material. We pay attention to Hansen's idea that concrete may be expected to act as semi-permeable membrane, and report the effect of concentration of solution and temperature on water flux in forward osmosis. In order to measuring volume of water flux from distilled water to solution of sodium chloride through hardened cement paste, specially designed apparatus was constructed, and the following result were obtained: (1) hardened cement paste acts as semi-permeable membrane, consequently, water flux in forward osmosis may occur. (2) Rate of water flux is proportion to concentration of dilute solution, and this suggests hardened cement paste is agreeable to the theory of membrane. (3) Effect of temperature on water flux is agreeable to Arrehenius equation and is great.

  • PDF

해수의 농도 변화에 따른 bentonite 침전에 대한 유변학적 고찰 (Rheological Study on bentonite Clay Sedimentation with various concentrations of Sea water)

  • 최상원;서호준
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.35-41
    • /
    • 1996
  • For studying of coagulation and sedimentation in estuarine clay, we obtained several flow curves with various concentrations of sea water by using Coutte type rotational rheometer. The initial shear stress on high concentration of sea water was observed big, but after this, its value is decreasing with increasing shear rate. The maximum pick of shear stress is decreasing with the decreasing of concentration of sea water The trend is same totally above for viscosity. The sedimentation times with the concentration of sea water vary in $\infty$ ~ 5 minutes. The zeta potential is changed dramatically between 114 and 118 concentration of sea water. That is consistent with the sedimentation graph. From these results, the phenomena of coagulation and sedimentation can be explained with viscoelastic terms on structual formation among particles by the changes of surface potential affected from contacting sea water to dispersed particles.

  • PDF

Spatial and seasonal variations of organic carbon level in four major rivers in Korea

  • Lee, Jaewoong;Shin, Kisik;Park, Changhee;Lee, Seunghyun;Jin, Dal Rae;Kim, Yongseok;Yu, Soonju
    • Environmental Engineering Research
    • /
    • 제21권1호
    • /
    • pp.84-90
    • /
    • 2016
  • Regionally the lowest average concentration of TOC was observed with 0.66 mg/L in Nakdong river, while the highest concentration of TOC was observed with 0.91 mg/L in Yeongsan river. The average concentration of TOC for national water quality monitoring site showed that the lowest average concentration of TOC was 1.58 mg/L in Han river, while the highest concentration of TOC was 3.37 mg/L in Yeongsan river. Seasonally, the average concentration of TOC at six upstream sites showed 0.77 mg/L and 0.56 mg/L, 0.69 mg/L and 0.63 mg/L, 0.80 mg/L and 0.73 mg/L, and 1.21 mg/L and 0.68 mg/L between wet season and dry season in Han river, Nakdong river, Gem river and Yeongsan river, respectively. For the national water quality site, the average concentration of TOC between wet season and dry season was 1.70 mg/L and 1.45 mg/L in Han river, 2.01 mg/L and 1.75 mg/L in Nakdong river, 2.01 mg/L and 1.60 mg/L in Gem river, and 3.75 mg/L and 3.00 mg/L in Yeongsan river. The distribution of TOC in upstream and national water quality monitoring sites on four major rivers have been influenced by seasonal and regional characteristics in Korea.

반도체 웨이퍼의 오존 수(水) 세정을 위한 고농도 오존발생장치 특성 연구 (A Study on the Characteristics of the High Concentration Ozone Generator for the Semiconductor Wafer Cleaning with the Ozone Dissolved De-ionized Water)

  • 손영수;함상용;문세호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.579-585
    • /
    • 2003
  • Recently the utilization of the ozone dissolved de-ionized water(DI-O3 water) in semiconductor wet cleaning process to replace the conventional RCA methods has been studied. In this paper, we propose the water-electrode type ozone generator which has the ozone gas characteristics of the high concentration and high purity to produce the high concentration DI-O3 water for the silicon wafer surface cleaning process. The ozone generator has the dual dielectric tube structure of silent discharge type and the water is both used to electrode and cooling water. We investigate the performance of the proposed ozone generator which has the design goal of the concentration of 7[wt%] and ozone generation quantity of 6[g/hr] at flow rate of 1[$\ell$/min). The experiment results show that the water electrode type ozone generator has the characteristics of 8.48[wt%] of concentration, 8.08[g/hr] of generation quantity and 76.2[g/kWh] of yield and it's possible to use the proposed ozone generator for the DI-O3 water cleaning process of silicon wafer surface.

하천수질오염이 농업용수에 미치는 영향 (Effect of Water Pollution on the Irrigation Water)

  • 나규환;이장훈;김치년
    • Environmental Analysis Health and Toxicology
    • /
    • 제6권3_4호
    • /
    • pp.155-161
    • /
    • 1991
  • The water quality in Wonju stream, Seom river in Kangwon province and Bokha, Shindun stream in Kyeonggi province was investigated between the season of irrigation on July, 1990 and of non-irrigation on September in 1989. The results of water quality obtained from this study were as follows; As for water quality of the Wonju stream and the Seom river, the concentration of COD, T-N, SS and Cu, and for the Bokha, Shindun stream, the concentration of T-N, SS and Cu were exceeded standard levels of quality guideline of agricultural water use in the season of irrigation. However, in the water quality of Wonju and Bokha stream, the concentration of T-N , SS and Cu, and in the Seom river, the concentration of T-N, SS, Cu and Zn were exceeded standard levels of agricultural water quality in the season of non-irrigation. And the average water quality of the 4 streams were not suitable for agricultural water use. The comparison of the annual average water quality of the 4 streams for pH, DO, T-N and SS were in statistics significantly different with p values less than 0.01. When the average water quality between the season of irrigation and non-irrigation in each stream was compared, DO and COD in the Wonju stream, COD in the Seom river, pH, DO, T-N, SS and Cu in the Shindun stream showed a significant difference with p<0.01. The average in the sediment were; COD, 5.65∼26.53 ppm; Cu, 0.26∼0.49 ppm and Zn 0.95∼2.97 ppm. The concentration of three contaminants were markedly higher than the water quality. And the concentration of COD, Zn in the sediment showed a significant difference with p<0.01, and Cu showed a considerably significant difference with p<0.05.

  • PDF

망간모래여과를 이용한 강변여과수의 망간제거 (Manganese Removal of Bank Filtrate using Manganese Sand Filtration)

  • 김충환;김학철;김한승;김범수;안효원
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.409-414
    • /
    • 2004
  • Pilot-scale experiments were performed for the treatment of bank filtrate contammg high manganese concentration around 2mg/L using rapid manganese sand filtration to investigate effects of oxidant dose and pH control on the removal efficiency of manganese. For theoretical dose ranges of oxidant (sodium hypochlorite) between 3 and 4mg/L, the manganese concentration of effluent was 0.57 mg/L, which corresponded to 72.5% removal and was higher than drinking water quality standards of 0.3mg/L. For excess dose ranges of oxidant between 4 and 8mg/L, the manganese concentration of effluent was reduced to 0.14mg/L, which corresponded to 94.5% removal, but the residual chlorine concentration was over 1.0mg/L. On the other hand, manganese removal efficiency drastically increased up to the value of 98.0%, which is equivalent to the effluent concentration of 0.03mg/L by controling pH to the range between 7 and 8 for the theoretical dose of oxidant. Consequently, these results indicated that appropriate dose of chemicals, such as oxidant and alkali, and continuous monitoring of manganese should be necessary to obtain efficient removal of manganese and to optimize the maintenance of treatment facilities for the treatment of bank filtrate with high concentration of manganese.

창원시 대산면 취수 부지의 지하수와 낙동강의 수리화학적 특성 비교

  • 함세영;정재열;이정환;김형수;류상훈;김태원;김문수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.307-311
    • /
    • 2006
  • Chemical analyses were conducted for Nakdong River water and riverbank filtrate in Daesan-Myeon area, Changwon City in 2005. Chemical components show different trends in wet season (June, July, August and September) and dry season (the other months). The patterns of chemical variation are classified into four types. Chemical components belonging Type I, as Na and $HCO_3$, show decrease in concentration during wet season and increase in concentration during dry season for both Nakdong River water and the riverbank filtrate. Chemical components belonging Type II, as Mg and $SO_4$, show decrease in concentration during wet season and increase in concentration during dry season for Nakdong River water while show the opposite trend for the riverbank filtrate. Chemical components belonging Type III, as Cl and $NO_3$, show increase in concentration from the start of wet season and high concentration during dry season for both Nakdong River water and the riverbank filtrate. Chemical components belonging Type IV, as Fe, show increase in concentration during wet season and decrease in concentration during dry season for both Nakdong River water and the riverbank filtrate.

  • PDF