• 제목/요약/키워드: Water Column

검색결과 2,046건 처리시간 0.033초

불포화 토양내 유류성분의 포화도 평가를 위한 분배추적자의 활용 방안

  • 박기호;박민호;신항식;고석오
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.20-28
    • /
    • 2006
  • Partitioning tracer tests were conducted to quantify the saturation degree of diesel and water in unsaturated soil, respectively. The use of partitioning tracers that partition into diesel, water, and air (i.e., three-phase partitioning), is in attractive alternative to traditional coring and analysis method. These gaseous partition tracers not global warming gas like CFC's are Butane, Acetylene, Ethylene, Methylene chloride, and Methane. The glass column packed with sandy soil was prepared, in which a three-phase system of air, water, and diesel was maintained. Conservative and partition gas tracers were injected into the columns and detected easily using a single GC detector(FID). For each tracer, a method of moments was used to estimate partition coefficient between water, diesel. and the air, respectively. The results from the column studies showed that the diesel/air tracer partition coefficient ranged from 8.2 to 868 and 9.2 for water/air. Saturation degree of diesel and water in the column, predicted by the partition coefficients obtained from tests, was underestimated up to 66% and 23% respectively.

  • PDF

하수처리 방류 소하천내 퇴적물로부터의 박테리아 유출 플럭스모델 비교 (A Test of Two Models for the Bacteria Flux across the Sediment/Water Interface in an Effluent-dominated Stream)

  • 안종호
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.165-172
    • /
    • 2010
  • Treated sewage could enable growth by providing key nutrients or seeding the sediments with enterococci strains that can grow in the environment. This study is to test the hypothesis that the flux of bacteria into the water column is rate-limited by the transfer of bacteria across the sediment/water interface. Two conceptual models are derived for the transfer of bacteria to the water column from the sediment/water interface: convective diffusion of isolated bacteria and resuspension of particle-associated bacteria. The model predictions are directly tested together with field measurements of bacteria and sediment in an effluent-dominated stream where high concentrations of enterococci in this stream originate primarily from growth of the bacteria in stream sediments. The results reveal that high concentrations of enterococci in this stream are transported primarily by resuspension of particle-associated bacteria accumulated at the sediment/water interface, either in the form of bacterial aggregates or in the form of inorganic particles.

목포항 수질의 계절적 변화 특성 I. 물리 환경과 유기 오염 (The Characteristics of Seasonal Variations of Water Quality in Mokpo Harbour 1. Physical Environment and Organic Pollution)

  • 김광수
    • 해양환경안전학회지
    • /
    • 제5권2호
    • /
    • pp.57-65
    • /
    • 1999
  • The in situ observations and the seawater analyses were conducted at all seasons from July 1996 to April 1999 for the purpose of describing the characteristics of seasonal variations of water quality in Mokpo harbour, Korea. Vertical stratification started to be formed in water column in spring, developed in summer and disappeared in fall. In summer, vertical density distribution of water column was found to be in stable structure with lower temperature and higher salinity of bottom water, and the vertical mixing of water between surface and bottom layers was restricted. In winter, however, surface water was found to be similar to bottom water in temperature and salinity, and water column was in unstable structure and in well-mixed condition between surface and bottom waters. The saturation percentage of dissolved oxygen(DO) in bottom water of inner part of Mokpo harbour at all seasons was shown to be decreased to the third grade or under the third grade of Korean standards of seawater quality. In particular, dissolved oxygen was oversaturated in surface water and undersaturated in bottom water in summer, due to stratification and organic pollution. The difference of DO concentration between surface and bottom waters was found to be greater in spring and summer than in fall and winter, due to stratification and photosynthesis of phytoplankton. The concentrations of chemical oxygen demand(COD) over the entire waters of Mokpo harbour were found to fluctuate from below the third grade to the first grade of Korean standards through all seasons and COD concentrations of same seasons were shown to be different year after year. In particular, in view of COD, the annual average seawater quality of Mokpo harbour was evaluated to be in third grade of Korean standards, due to organic pollution. The average COD of surface water was greater than that of bottom water in spring and summer, due to the autochthonous COD caused by production of phytoplankton in surface waters, while the average COD of surface water was similar to that of bottom water in fall and winter, due to the vertical mixing of water between surface and bottom layers.

  • PDF

Batch Column에서의 슬러지농도변화에 대한 연구 (Study on Sludge Concentration Change in Batch Column)

  • 박석균;강선홍;김동하
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.443-450
    • /
    • 2006
  • For understanding sludge concentration profile as a function of time, sludge was sampled at each sampling port. When sludge concentration was 3g/L, the vertical sludge concentration distribution was similar to that of 2g/L of sludge concentration. During the early stage of sludge settling, sludge concentration increased remarkably as the sludge interface height in batch column became lower. The higher sludge concentration became, the worse sludge setteability became. Also, the type of sludge settling was influenced with sludge concentration gradient in batch column. In the same concentration, the greater sludge concentration gradient was, the faster sludge interface settled down. And the changing sludge concentrations in a batch settling or a continuous settling were simulated by using the equation of sludge interface height change model.

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • 제17권5호
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

강변여과에 의한 이.취미 물질 제어 특성에 관한 타당성 연구 (A Feasibility study on Removal Characteristics of Taste and Odor using Bank Filtration Treatment)

  • 맹승규;박노석;임재림;김성수;정우창
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.307-317
    • /
    • 2010
  • This study was conducted in order to investigate bulk organic matter characteristics and behavior of geosmin and 2-methylisoborneol (2-MIB) during riverbank filtration, which are general surrogates of taste and odor in drinking water. Column studies were used to simulate bank filtration systems. Most of the aliphatic organic matter was removed effectively after soil passage, and it is believed to be polysaccharides according to LC-OCD and F-EEM analysises. Removal efficiencies of geosmin and 2-MIB within the filtration column reached above 95%. It was found that the removal of total dissolved organic matter has a correlation with that of geosmin and 2-MIB in the near of filtration surface (about 50cm).

Evaluation and modelling of the separation of anthracite in the hindered-settling column

  • Kim, Jeong-Yun;Cho, Hee-Chan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.611-617
    • /
    • 2003
  • This study was performed to develop the method for producing industrial coal sources by cleaning Korean anthracite. Laboratory hindered-settling separation column was set and three coal samples were used for tests. Tests were conducted to evaluate the effects of the major operating variables, teeter water flow rate and relative column pressure (set point). Additional tests were performed to elevate the yield and properties of the products using air bubble injecting process. In results, nice products were obtained with high teeter water flow rate and air bubble injection. Also, model of continuous hindered-settling separation process was established to assist the evaluation of the equipment and several operating variables, such as dispersion, teeter water flow rate, feeding rate, etc.

  • PDF

진동수주형 파력발전 시스템에서 운동과 파랑회절의 영향 (Motion and Wave Transmission Effect on Floating OWC(Oscillating Water Column) Wave Energy Conversion System)

  • Lee, Sang-moo;Kim Seoung-gun
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.20-25
    • /
    • 2001
  • 부유식 파랑에너지 변환시스템(Oscillating Water Column)에서 에너지 변환은 입력파와 챔버, 챔버내 공기의 상호작용으로 이루어진다. 이 논문은 파랑에너지를 기계적 운동으로 변환하는 기계적 특성을 해석한다. 단일 진동수 규칙파가 입력되었을 때에 파에 의하여 챔버의 상하운동이 선형적으로 발생하며, 이 상하운동은 챔버내의 압력 변화에 영향을 받는다. 상하운동과 챔버내로 투과한 파, 그리고 챔버내 압력에 의해 발생되는 파에 의해 챔버내의 상대운동을 정하고, 그 상대운동에 의한 공기의 압축 팽창과 온도상승을 근사적 열역학적 방정식으로 해석하여 오리피스를 통한 유량과 압력을 기준으로 에너지 변환요율을 결정하였다. 얻어진 식은 간단하면서도 관련요소의 영향을 전반적으로 표현한다. 개구율 변화에 따른 운동응답을 비교하였다.

  • PDF

차세대 신형원자로의 피동형 안전 주입장치를 위한 프리피스톤 스터링 펌프의 동특성 모델 (Dynamic Modeling of the Free Piston Stirling Pump for the Passive Safety Injection of the Next Generation Nuclear Power Plant)

  • Lee, Jae-Young
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.149-154
    • /
    • 1999
  • This paper describes a passive safety injection system with free piston Stirling pump working withabundant decay heat in the nuclear reactor during the hypothetical accident. The water column in the tube assembly connected from the hot chamber to the cold chamber in the pump oscillates periodically due to thermal volume changes of non-condensable gas in each chamber. The oscillating pressure in the water column is converted into the pumping power with a suction-and-bleed type valve assembly. In this paper a dynamic model describing the frequency of oscillation and pumping pressure is developed. It was found that the pumping pressure is a function of the temperature difference between the chambers. Also, the frequency oscillation depends on the length of the tube with water column.

  • PDF

Numerical Analysis of Wave Field in OWC Chamber Using VOF Model

  • ;현범수
    • 한국해양공학회지
    • /
    • 제22권2호
    • /
    • pp.1-6
    • /
    • 2008
  • Recently Oscillating Water Column (OWC) plants have been widely employed in wave energy conversion applications. It is necessary to investigate the chamber and optimize its shape parameters for maximizing air flow and energy conversion due to wave conditions. A 2D numerical wave tank based on a Fluent and VOF model is developed to generate the incident waves and is validated by theoretical solutions. The oscillating water column motion in the chamber predicted by the numerical method is compared with the available experimental data. Several geometric scales of the chamber are calculated to investigate the effect of the shape parameters on the oscillating water column motion and wave energy conversion.