• Title/Summary/Keyword: Water Column

Search Result 2,046, Processing Time 0.027 seconds

Column regeneration for Partisil/Partisphere ion-exchange columns (Partisil/Partisphere 이온 교환 컬럼 재생 가이드)

  • Mark Fever;Gemma Howse
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.5.1-5.3
    • /
    • 2024
  • The document discusses the regeneration of Partisil/Partisphere ion-exchange columns in chromatography. It mentions that column efficiency can diminish with use due to the accumulation of sample and/or mobile phase impurities at the head of the column. This can lead to a change in back pressure, lower column efficiency, and sometimes a change in selectivity. The document outlines a procedure that may restore column performance. The document also provides everyday practices to enhance the lifetime of a column. These include using only high-purity HPLC solvents and buffers, using freshly prepared mobile phases and buffers, filtering mobile phases to remove particulates, using appropriate sample clean-up procedures, using a guard column or pre-column filter, and working within the pressure and flow rate limitations of the column. For the regeneration of Partisil/Partisphere SAX, SCX, WAX, and WCX columns, the document suggests passing 20 column volumes of various mobile phases through the column. These include a buffer wash, distilled water, an acid wash, a chelating wash, a methanol wash, and a buffer for separation. The document emphasizes that not all of these wash steps are required for every column clean-up and that some chromatographers require only a combination of certain steps.

  • PDF

Research of geothermal analysis and experimental test for Standing Column Well type system (우물관정(SCW: Standing Column Well)형 냉난방 시스템의 지중열 해석과 실증 실험에 관한 연구)

  • Kwon, Iksang;Hong, Gibae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.173-173
    • /
    • 2010
  • This thesis identified basic design elements (Sustainable Yield, Temperature of Groundwater, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

Evaluation of Similarity of Water Column Properties and Sinking Particles between Impact and Preserved Sites for Environmental Impact Assessment in the Korea Contracted Area for Manganese Nodule Development, NE Pacific (북동태평양 한국 망간단괴 광구해역에서 환경충격 시험지역과 보존지역간의 수층환경 및 침강입자 플럭스 유사성 비교)

  • Son, Juwon;Kim, Kyeong Hong;Kim, Hyung Jeek;Ju, Se-Jong;Yoo, Chan Min
    • Ocean and Polar Research
    • /
    • v.36 no.4
    • /
    • pp.423-435
    • /
    • 2014
  • Verifying the similarity of environmental characteristics between an artificial impact site and a preserved or reference site is necessary to quantitatively and qualitatively evaluate the environmental impact of mining activity. Although an impact site (BIS station) and a preserved site (called KOMO station) that have been selected in the Korea manganese nodule contract area may share similar environmental characteristics, similarities in terms of the water column environment between both sites has not been investigated. In this study, we compared the chemical properties of the water columns and sinking particle fluxes between BIS and KOMO stations through two observations (August 2011 and September 2012). Additionally, we observed particle fluxes at the KOMO station for five years (July 2003~July 2008) to understand long-term natural variability. Vertical distributions of water column properties such as dissolved oxygen, inorganic nutrients (N, P, Si), total organic carbon below surface layer (within the depth range of 200 m) were not considerably different between the two sites. Especially, values of water column parameters in the abyssopelagic zone from 4000 m to bottom layer (~5000 m) were very similar between the BIS and KOMO sites. Sinking particle fluxes from the two sites also showed similar seasonality. However, natural variation of particle flux at the KOMO site varied from 3.5 to $129.9mg\;m^{-2}day^{-1}$, with a distinct temporal variation originating from ENSO events (almost forty times higher than a minimum value). These results could provide valuable information to more exactly evaluate the environmental impact of mining activity on water columns.

Numerical Analysis of Chamber Flow and Wave Energy Conversion Efficiency of a Bottom-mounted Oscillating Water Column Wave Power Device (고정식 진동수주형 파력 발전장치의 챔버 유동 및 파에너지 변환효율 해석)

  • Koo, Weon-Cheol;Kim, Moo-Hyun;Choi, Yoon-Rak
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.3
    • /
    • pp.388-397
    • /
    • 2010
  • A two-dimensional time-domain, potential-theory-based fully nonlinear numerical wave tank (NWT) was developed by using boundary element method and the mixed Eulerian-Lagrangian (MEL) approach for free-surface node treatment. The NWT was applied to prediction of primary wave energy conversion efficiency of a bottom-mounted oscillating water column (OWC) wave power device. The nonlinear free-surface condition inside the chamber was specially devised to represent the pneumatic pressure due to airflow velocity and viscous energy loss at the chamber entrance due to wave column motion. The newly developed NWT technique was verified through comparison with given experimental results. The maximum energy extraction was estimated with various chamber-air duct volume ratios.

Experimental Evaluation of Design Parameters for TLCD and LCVA (TLCD와 LCVA의 설계파라미터에 대한 실험적 평가)

  • Lee, Sung-Kyung;Min, Kyung-Won;Park, Ji-Hun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.5
    • /
    • pp.403-410
    • /
    • 2009
  • In this paper, damping coefficients and effective masses of tuned liquid-type column dampers were quantitatively evaluated based on experimental results by using system identification technique. First, shaking table tests were performed for two types of tuned liquid-type column dampers. Then, the dynamic characteristics of dampers used in this study were experimentally grasped from harmonic wave excitation testing results of the dampers with various water level. Finally, damping ratios and effective masses of the dampers with varying water level were quantitatively evaluated from minimizing the errors between numerical and experimental results. It was confirmed from system identification results that damping ratio and effective mass are decreased as the water level of dampers is increased.

Analysis and Design of a Wave Energy Conversion Buoy

  • Oh, Jin-Seok;Bae, Soo-Young;Jung, Sung-Young
    • Journal of Navigation and Port Research
    • /
    • v.32 no.9
    • /
    • pp.705-709
    • /
    • 2008
  • In the sea various methods have been conducted to capture wave energy which include the use of pendulums, pneumatic devices, etc. Floating devices, such as a cavity resonance device take advantages of both the water motion and the wave induced motions of the floating body itself. The wave energy converter is known commercially as the WAGB(Wave Activated Generator Buoy) and is used in some commercially available buoys to power navigation aids such as lights and horns. This wave energy converter consists of a circular flotation body which contains a vertical water column that has free communication with the sea. A theoretical analysis of this power generated by a pneumatic type wave energy converter is performed and the results obtained from the analysis are used for a real wave energy converter buoy. This paper is shown to have an optimum value for which maximum power is obtained at a given resonant wave period Also, the length of the internal water column corresponds to that of the water mass in the water column. If designed properly, wave energy converter can take advantage not only of the cavity resonance, but also qf the heaving motion of the buoy. Finally, simulation is performed with a LabVIEW program and the simulation results are applied to a wave energy simulator for modifying design data for a wave energy converter.

Visualization of the Water Column Collapse by using SMAC Method (SMAC법을 이용한 물기등 붕괴의 가시화)

  • Kim, Nam-Hyeong;Kim, Nam-Guk
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.605-615
    • /
    • 2001
  • SMAC method, one of the numerical simulation techniques, is modified from the original MAC method for the time-dependent variation of fluid flows. The Navier-Stokes equations for incompressible time-dependent viscous flow is applied, and marker particles which present the visualization of fluid flaws are used. In this study, two-dimensional numerical simulations of the water column collapse are carried out by SMAC method, and the simulation results are compared with Martin and Moyce's experimental data and result of the MPS method. A good results are obtained. This numerical simulation could also be applied to the breaking phenomenon of hydraulic structures such as dam break.

  • PDF

Calculation of Film Diffusion Coefficients and Surface Diffusion Coefficients of Volatile Organic Compounds Using Activated Carbon Adsorption Model and Small Column Test (활성탄 흡착모델과 칼럼실험을 통한 Volatile Organic Compounds의 막확산계수와 표면확산계수의 도출)

  • Lee, Byoung-Ho;Lee, Joon-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.72-80
    • /
    • 1999
  • Separation of VOCs(Volatile Organic Compounds) in Water Using Activated Carbon is known to be effective. Activated Carbon has been and will be employed in many water treatment plants. Simplified plug flow homogeneous surface diffusion model(PFHSDM) has been used to predict adsorption of organic matter. Finite Element Method(FEM) was used to analyze the model. Out of water quality control substances, benzene, toluene and tetrachloroethylene were used in the small column test. Film diffusion coefficients and surface diffusion coefficients were obtained from the column test, and were compared with the modeling results. Mc Cune, Williamson, William and Kataoka model, were compared with film diffusion coefficients obtained in the test. McCune model was fitted best for those VOCs used in this experiment. Film diffusion coefficients of VOCs obtained were benzene 0.265 cm/min, toluene 0.348 cm/min and tetrachloroethylene 0.298 cm/min. Surface diffusion coefficients of VOCs obtained were benzene $6.36{\times}10^{-8}cm^2/min$, toluene $3.20{\times}10-8cm2/min$, and tetrachloruethylene $4.94{\times}10^{-8}cm^2/min$.

  • PDF

Evaluation of Drinking Water Treatment Efficiency according to Regeneration Temperatures of Granular Activated Carbon (GAC) (입상활성탄 재생온도에 따른 정수처리 효율 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Jung, Jong-Moon;Ryu, Dong-Choon;Yoo, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1163-1170
    • /
    • 2015
  • This study carried out continuous column test for estimating the regeneration efficiency with regeneration times and temperatures. More times regenerated granular activated carbon (GAC) has more ash in the GAC and has less apparent density. Two times regenerated GAC ($2^{nd}$ re-GAC) could removed the Trihalomethanes (THMs) in the water for the first two week after starting continuous column test, on the other hand five times regenerated GAC ($5^{th}$ re-GAC) did not have adsorption capacity. The THMs concentration in the effluent was almost equal or higher than that of influent at the first time of continuous column test. $2^{nd}$ re-GAC showed much more DOC adsorption capacity than $5^{th}$ re-GAC and the GAC which was regenerated with $700^{\circ}C$ had highest DOC removal efficiency among the GACs with 600, 700, 800, $900^{\circ}C$ regeneration temperatures. It is anticipated the cost of GAC regeneration could be saved more 100 million won by reducing the furnace temperature of 3rd~4th and 5th~6th about $150^{\circ}C$ compared to the current regeneration condition.