• 제목/요약/키워드: Water Chiller

검색결과 120건 처리시간 0.033초

7RT급 암모니아 흡수식 냉온수기의 냉방성능 특성 (The Characteristics of Cooling Performance on 7RT Ammonia Absorption System)

  • 이호생;진병주;윤정인;황준현;진심원;경익수
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.433-438
    • /
    • 2009
  • Experimental results for performance characteristics of small $NH_3$ absorption chiller/ heater are presented. The apparatus consists of 7RT water-cooled absorption system, solution pump, boiler, cooling tower and peripheral devices. The effect of experimental parameters, such as refrigerant mass flow rate, solution mass flow rate and cooling water temperature have been investigated in view of the system performance. The capacity of each heat exchanger increased as refrigerant mass flow rate increased in cooling mode. Also, a cooling capacity increased as a strong solution mass flow rate increased. The cooling and heating COP show 0.5, 1.5 regardless of refrigerant mass flow rate, respectively. The results focus on the evaluation for performance characteristics of system with respect to variation of refrigerant mass flow rate under standard design conditions.

영천 화강암지역 지하수의 지화학적 모델링 (Geochemical Modeling of Groundwater in Granitic Terrain: the Yeongcheon Area)

  • Koh, Yong-Kwon;Kim, Chun-Soo;Bae, Dae-Seok;Yun, Seong-Taek
    • 대한지하수환경학회지
    • /
    • 제5권4호
    • /
    • pp.192-202
    • /
    • 1998
  • 영천 도수터널 내 화강암 지역의 단열대를 따라 유출되는 지하수에 대하여 지화학 및 환경동위원소 연구를 수행하였다. Ca-HCO$_3$유형에 속하는 유출수의 화학 조성은 화강암을 구성하는 규산염 광물 및 열극 충진 방해석의 지화학적 용해 반응에 의해 설명되며, 그 수문지화학적 진화는 부분적 개방계에서 진행되었음을 보여준다. 환경동위원소 연구 결과, 유출수는 모두 강수 기원으로서 적어도 1953년 이전에 함양된(즉 체류 시간이 최소 45년 이상인) 지하수임을 지시해주며, 나아가 지표로부터의 거리와 단열대의 발달 상태에 따라 부분적으로 지표수의 혼입이 진행되고 있음을 지시한다. 지화학 반응 경로 모델인 CHILLER를 이용하여 본 지역 화강암 지하수의 수문지화학적 진화를 모델링 하였다. 그 결과, $Ca^{2+}$, $Na^{+}$, HCO$_3$$^{-}$ 및 pH는 규산염 광물 및 방해석의 용해 작용과 더불어 점차 증가되는 반면, $Mg^{2+}$$K^{+}$는 각각 몬트모릴로나이트와 백운모의 2차 생성과 더불어 감소됨을 보여준다. 2차 광물의 생성 순서는 적철석, 깁사이트, 카올리나이트, 몬트모릴로나이트, 백운모, 장석의 순이다. 모델링 결과는 유출수의 물리화학적 분석값과 2차 광물의 동정 결과와도 잘 일치한다. 따라서, 이러한 물-암석 상호 반응 모델링을 비교적 복잡한 암반 지하수의 수문지화학적 진화 해석에 타당성 있게 적용할 수 있음을 보여준다.

  • PDF

흡수식 대온도차 시스템에서 2단 증발/흡수기의 성능 특성에 관한 수치적 연구 (Performance analysis for the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;강용태;임익태;문상돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.304-308
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

냉수 대온도차 흡수식 냉동기용 2단 증발기/ 흡수기 최적 설계 (Optimum design of the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;임익태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.203-211
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

열원조건 분석 통한 흡수식 히트펌프 적용 열에너지 네트워크의 에너지 절감 예측 (A Study on the Energy Reduction of a Heating Network Through the Application of an Absorption Heat Pump)

  • 나선익;이영수;백영진;이길봉
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.239-248
    • /
    • 2017
  • At the $21^{st}$ Conference of the Parties (COP) of the United Nations Climate change Conference, representatives of the 195 member countries reached an agreement requiring all participating countries, including Korea, to establish proactive measures to fight climate change. Under this vision, energy network technologies are deemed as a key site of research towards meeting this goal. Herein, the headquarters of the Korea Institute of Energy Research (KIER) is a worthy site for carrying out energy network technology research insofar as it contains various heat sources. To prepare for this research, a study was conducted analyzing the heat sources at KIER based on measured data. The study also consisted of developeding simulation models to predict the amount of energy savings that could be derived by replacing an absorption chiller/heater with an absorption heat pump during winter seasons. In our simulation results, we observed a primary energy saving ratio of 65~72% based on the water temperature from the heat source of a coal power plant.

Objective Meat Quality and Volatile Components as a Function of Cooking Temperature in Beef Longissimus lumborum

  • Ji, Joong-Ryong;Park, Kyung-Mi;Choe, Ho-Sung;Hwang, In-Ho
    • 한국축산식품학회지
    • /
    • 제30권3호
    • /
    • pp.373-384
    • /
    • 2010
  • The present paper describes the effect of cooking temperature on objective meat qualities and volatile components in beef longissimus lumborum. Twenty samples of lumbar vertebrae longissimus muscle from Australian Black Angus (grain-fed and chiller aged for 29 d) were screened. Samples were cooked at 50, 70 or $90^{\circ}C$ in a pre-heated water bath for 1 h and uncooked raw samples were used as control. The results revealed that elevating the heating temperature from 50 to $90^{\circ}C$ led to a significant (p<0.05) increase in WB-shear force, total energy required for WB-shear force, cooking loss, pH and soluble collagen content, whereas a significant (p<0.05) linear decrease in protein solubility was observed. The results also revealed that the WB-shear force at $70^{\circ}C$ was significantly (p<0.05) lower than that observed at $50^{\circ}C$ and $90^{\circ}C$. However, the effect of temperature on cooking loss and protein solubility was notably (p<0.05) higher at $70^{\circ}C$. The detectable volatile components were mostly produced from fat oxidation, and temperature effects on the generation of volatile components were significantly (p<0.05) greater for aldehydes (hexanal, benzaldehyde, nonanal and octanal) than for ketones and hydrocarbons (hexane, benzene, decan, toluene and 3-methylnonane).

광화유체의 비등과 희석에 의한 통영 천열수계 Au-Ag-Te 장화작용에 대한 반응경로 모델링 (Au-Ag-Te Mineralization by Boiling and Dilution of Meteoric Ground-water in the Tongyeong Epithermal sold System, Korea: Implications from Reaction Path Modeling)

  • Maeng-Eon Park;Kyu-Youl Sung
    • 자원환경지질
    • /
    • 제34권6호
    • /
    • pp.507-522
    • /
    • 2001
  • 통영광산은 첨열수광상으로서 능망간석 , 백운모, 일라이트, 황철석 , 방연석 , 황동석 , 섬아연석 , 아칸다이트 및 헤사이트등의 광물을 수반하는 초기의 광석광물 침전시기와 후기의 맥석광물 침전시기로 구분된다. 초기는 반복적인 대상구조를 띠고, 황화광물이 침전된 시기로서 텔루리움 광물과 함께 엘렉트럼이 산출된다. 후기에는 주로 단산염 광물과 천금속광물이 침전되었다. 통영 열수계에서 광화단계에 따른 상이한 열수유체의 변천과정을 구체적으로 규명하기 위하여 프로그램 CHILLER를 이용한 수치모델링이 실시되었다. 반응경로 모델링은 28$0^{\circ}C$에서 모암인 안산암과의 반응을 비롯하여, 27$0^{\circ}C$에서 12$0^{\circ}C$까지의 단순한 등압 냉각, 비등과 지하수의 혼입에 따른 희석 및 압력파 온도가 감소되는 조건에서 수행하였다. 모델링 결과 초기 광화유체는 산성용액(pH=5.7)으로 상대적으로 높은 염농도와 금속원소 함량이 높다. 장화유체 내의 금의 함량은 열수계의 천금속원소 총량과 황화물의 활동도에 의해 지배된다. 통영 천열수계에서의 광화작용은 천부에서 일어난 참화유체의 비등과 이에 수반된 가열된 지하수의 흔입에 의한 반응경로를 반영하며, 현미경에서 관찰된 광물공생 특성과 모델링에 의한 침전광물의 조합 및 엘렉트럼의 화학조성 등에서 동일한 경향을 나타낸다. 이러한 유사성은 Te 함유하는 천열수 금 . 은광상이 열수계에서의 비등과 유체혼합(희석)에 의해 생성되었음을 지시한다. 반응경로 모델링 연구는 광상성인을 이해하는 중요한 수단이며, 유사한 지질환경에서의 광강탐사에 유용한 자료로 활용될 것으로 생각된다.

  • PDF

육계 도축 시 전기 실신 시간이 육질에 미치는 영향 (Effect of Different Stunning Time on Meat Quality of Broiler)

  • 채현석;안종남;유영모;함준상;정석근;이종문;최양일
    • Journal of Animal Science and Technology
    • /
    • 제47권6호
    • /
    • pp.1017-1024
    • /
    • 2005
  • 육계의 도계과정 중에서 실신 전압을 50V, 255Hz로 고정하고 실신 시간을 변화시켜 닭고기의 육질에 미치는 영향과 저장 특성을 조사하여, 최적 실신 시간을 구하고자 실시하였다.실신시간에 따른 닭고기의 pH는 실신시간이 증가함에 따라 감소하는 경향을 나타내었으며, 육색에서 명도 및 적색도는 껍질, 가슴살, 다리살의 경우 실신시간이 증가할수록 높아지는 경향을 나타냈으나, 황색도는 껍질, 가슴살 및 다리살 부위에서 증가하는 경향을 나타냈으나, 날개에서는 거의 차이가 없었다. 가열감량은 실신시간이 증가할수록 증가하였으나 보수력은 반대의 경향을 나타내었으며, 전단력은 50V(5초)가 1.38kg/05$\cm^2$이였고 50V(11초)는 1.65kg/05$\cm^2$를 나타나 실신시간이 길어질수록 증가하는 경향을 나타내었다. 외관평가에서 닭고기 1등급 출현율은 실신시간이 증가하면서 약간 증가하는 경향을 나타내었으며, PSE는 전처리구에서 0.02% 이하로 낮은 발생율을 나타내었고, 혈흔은 50V, 5초 처리구에서 0.11cm로 다른 처리구 0.04cm 보다 약간 증가하는 경향을 나타내었다. 관능 특성은 50V, 8초간 실신하는 처리구에서 다즙성, 연도, 향미가 우수하였으나, 실신시간에 따라서 일정한 경향을 나타내지 않았다. 실신시간에 따른 닭고기의 저장성은 지방산패도를 나타내는 TBARS 값은 저장 3일에 50V, 5초 처리구는 0.39mgMA/kg, 8초 0.42mgMA/kg, 11초 0.33mgMA/kg로 실신 시간에 따라서 일정한 경향을 보이지 않았으나 실신시간이 가장 긴 11초 처리구에서 5, 8초 처리구보다 유의적으로 낮게 나타났다. 단백질변성도의 값을 나타내는 VBN가는 전압이 낮은 처리보다 높은 처리에서 증가폭이 컸으며 전체적으로는 저장기간이 길어짐에 따라 증가하는 경향을 나타내었다.

지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES) (A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage)

  • ;한정상;한혁상;한찬;김형수
    • 자원환경지질
    • /
    • 제38권6호
    • /
    • pp.717-729
    • /
    • 2005
  • 일반적으로 대규모 건물의 피크 냉방 부하는 난방부하보다 크다. 북위도의 한냉한 지역에 소재한 대규모건물의 냉난방 설비는 건물 내부에서 생성되는 발열량과 태양으로부터 획득되는 열량에 따라 좌우된다. 최대 냉방부하에 적합하도록 냉난방설비와 지중루프를 설치하는데 소요되는 비용은 일반적으로 초기투자비가 적게 드는 전통적인 HVAC시스템에 비해 다소 고가이다. 빙축열조(Thermal ice storage, TES)시스템은 과거 수년동안 일반 HVAC에서 냉동기의 용량을 축소시키거나 최대 전력부하 시간대를 바꾸기 위해 사용되어온 기술이다. 일반적으로 건물 난방을 위해서는 보일러와 같은 전통적인 난방설비를 이용하고 그 다음날의 건물냉방을 위해서는 전력료가 저렴한 야간에 빙축을 시키는 빙축열기법을 이용한다. 얼음에서 추출한 잠열 에너지의 장점을 이용하기 위해 설계된 분배시스템(distribution system)과 열원과 열배출원(열침, sink)대신에 지중열 교환기(지중루프)를 이용하면 많은 장점이 있다. 공간 난방과 급탕을 공급하기위한 분리형 설비를 별도로 사용하지 않아도 된다. 공간난방용으로 소요되는 설비용량을 축소시킬 수 있으며-소요 지중열 교환기의 규격과 비용을 절감시킴은 물론 지열 HVAC시스템의 효율을 배가 시킬 수 있으며 온실가스 배출량을 대폭 감축시킬 수 있다. 또한 TES를 적용하면 대규모 건물의 냉난방부하와 열펌프의 용량을 $40\~60\%$ 정도 감축시킬 수 있으며 설비대수와 기계실 공간을 줄일 수 있다. 뿐만아니라 피크 냉난방부하를 토대로 설계한 지원 열펌프 시스템(Ground source heat pump system)의 지중루프를 $1/4\~1/3$가지 줄일 수 있어 도심지역에서 지중루프를 설치할 때 장애요인인 지중루프 설치공간문제와 지중암석의 열적특성문제를 동시에 해결할 수 있다.문이며, 따라서 $^{137}Cs$의 분포는 광물분포 보다는 TOC의 함량에 더 큰 영향을 받고 있음을 보여준다.과 위기 고조 단계, 그리고 갈등 해소 단계등 모든 시기에서 두 신문의 주요 행위자 구성에 있어서 차이가 나타났다. 다시 말해, 조선일보는 기본적으로 총파업을 둘러싼 문제의 구성과 발전, 해소 과정에서 정당이나 대통령, 야당 지도자 등과 같은 정치관련 행위자를 강조하고 있었다. 반면에, 한겨레는 대체로 로든 사건진행 단계에서 노동 관련 단체들과 시민단체의 역동적인 연대와 활동에 초점을 맞추고 있는 것으로 나타났다.술 후 24시간에 599.4$\pm$145.6, 678.8 $\pm$256.4였다(t-test, p < 0.05). 동종 수혈은 RAP군에서 34명 중 7명에서(20.6$\%$), 대조군에서는 46명중 16명에서(34.8$\%$) 시행되어, RAP군에서 유의하게 빈도가 낮았다(Chi-square test, p < 0.05). 결론: 역행성 자가 충전법은 심폐바이패스의 충전에 의한 혈액희석을 최소화함으로서, 개심술 후 출혈과 동종수혈을 또한 줄이는 데 효과적인 방법이 될 수 있다고 생각된다.타내지 않았다.성 교사, 가정 전공 교사가 그렇지 않은 교사보다 해석적, 해방적 행동목표를 더 중요하게 인식하고 있었다. 특히 가정교육 철학을 배운 경험이 있는 교사가 그렇지 않은 교사보다 해방적 행동체계 목표를 중요시하는 것으로 나타났다. 이 연구 결과는, 실천 비판적인 가정 교과의 본질을 구현하기 위해서는 주생활 영역의 교육과정에 기술적, 해석적, 해방적 행동에 대한 목표들을 고루 포함하여야 하며 특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한

현수방법이 한우육질에 미치는 영향 (The effect of suspension method on meat quality of Hanwoo)

  • 황인호
    • Journal of Animal Science and Technology
    • /
    • 제46권3호
    • /
    • pp.427-436
    • /
    • 2004
  • 본 연구는 현수방법이 한우 육질에 미치는 영향과 근육간 육질특성 차이에 영향을 주는 요인을 평가하기 위해 수행되었다. 총 18두 한우 거세우의 좌도체와 우도체를 순차적으로 tendaerstretch(TS) 처리하고, 다음날 양 도체의 longissimus(LD), semimembranosus(SM), tricepsbrachii(TB)을 발골하여 7일 동안 숙성하였다. 관능검사는 한국식 바베큐(BBQ)와 서양식 스테이크(Grill) 방법으로 360명을 대상으로 실시하였고, 동시에 전단력, 보수력, 가열 감량, 근절길이와 근내 조지방 함량을 측정하였다. 소비자 맛 지수는 도체 육질등급이 높은 경우 LD는 높았으나(P < 0.05), TB는 차이가 없었다. 한편, SM은 Grill의 경우에만 높은 듭급이 높은(P < 0.05) 값을 없었다. 이 결과는 높은 도체 육질등급은 LD의 경우 맛이 우수하다는 것을 증명하나, SM과 TB의 맛은 대변하지 못한다는 것을 시사한다. Tenderstretch는 TB의 관능 특성 및 물리적 육질 특성에는 영향을 미치지 않았고, 다른 근육의 가열 감량에도 영향을 미치지 않았다. 한편, 이 현수 방법은 LD와 SM의 근절길이와 맛 지수를 증가(P < 0.05) 시키고 전단력을 감소(P < 0.05) 시켰다. 이 결과는 시료가 7일 동안 냉장 숙성되었다는 점을 고려할 때, 결체조직의 약화와 관련되었다는 것을 시사하고 있다. 도체 육질등급에 따른 현수방법의 특별한 효과는 대부분 육질 특성에는 관찰되지 않았으나, tenderstretch된 SM의 맛 지수가 처리를 하지 않은 LD와 동하였다. 이 결과는 소비자들이 tenderstretch한 우둔을 불고기 형태로 소비했을 경우 등심과 같은 맛을 느낄 수 있다는 것을 의미한다. 소비자 맛 지수와 기계적 육질 측정치와의 상관관계에서, LD의 경우 근내지방과 유의적(P < 0.05) 상관관계를 보였고, SM의 경우는 근절길이와 유의적(P < 0.05) 관계를 보였다. 이 결과는 근육에 따라 맛을 대변할 수 있는 예측 요인이 다르다는 것을 시사한다. SM의 경우 보수력과 가열 감량이 높은 음의 상관관계를 보여, 보수력과 가열 감량과의 관계를 잘 나타내고 있으나, 다른 근육에서는 높은 상관도가 관찰되지 않았다. 소비자가 느끼는 맛 차이를 포함하여 실험실적 측정요인을 이용한 근육간 별별력 검사를 하였을때 약 77%의 확률에서 분류되었다. 근육간 차이에서 가장 큰 요인은 맛지수였고, 가열 감량과 근절길이도 큰 요인으로 작용했다. 이 결과는 전단력 측정의 절대치와 맛과의 관계는 근육에 따라 다르다는 것을 나타내며, 근육간 맛 차이는 전단력보다 가열 감량과 근절길이가 설명력이 높다는 것을 나타냈다. 본 연구 결과는 Tenderstretch는 우둔과 같은 비인기부위의 맛 지수를 높이는데 유용한 방법이고, 기계적인 육질측정 방법이 국내 소비자 맛 지수를 예측하는데 한계가 있다는 것을 시사한다.