• Title/Summary/Keyword: Water Characteristics

Search Result 17,695, Processing Time 0.048 seconds

Methodology for the Identification of Impaired Waters Using LDC for the Management of Total Maximum Daily Loads (오염부하지속곡선(LDC)을 이용한 수질오염총량관리 단위유역 목표수질 달성여부 평가방법)

  • Park, Jun Dae;Oh, Seung Young
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.693-703
    • /
    • 2012
  • Load Duration Curve(LDC) is a useful tool for analyzing water quality characteristics under various stream flow conditions. This study investigated the methods to identify impaired waterbodies in the assessment of water quality goal attainment by using LDC for the management of Total Maximum Daily Loads (TMDLs). Three methods were proposed. Non-typical regime exclusion method is a method to exclude water quality observations in the non-typical extreme flow conditions in order to minimize the influence of non-ordinary water quality. Flow regime weighted average method is a method to calculate weighted mean water quality instead of arithmetic mean in order to consider water characteristics properly on stream flow regime in addition to the effect of Non-typical regime exclusion method. Load exceeded interval comparison method is a method to compare the intervals between the attained and non-attained load duration periods on the LDC. The assessment of water quality goal attainment can be performed more reasonably and precisely considering water quality variations on stream flow conditions by applying these proposed methods.

Micro/nano Tribological and Water Wetting Characteristics of Ion Beam Treated PTFE Surfaces

  • Yoon, Eui-Sung;Oh, Hyun-Jin;Yang, Seung-Ho;Kong, Hosung
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.12-16
    • /
    • 2002
  • Micro/nano tribological and water wetting characteristics of ion beam treated PTFE (polytetrafluoroethylene) surfaces were experimentally studied. The ion beam treatment was performed with a hollow cathode ion gun at different argon ion dose conditions in a vacuum chamber to modify the topography of PTFE surface. Micro/nano tribological characteristics, water wetting angles and roughness were measured with a micro tribe tester, SPM (scanning probe microscope), contact anglemeter and profilometer, respectively. Results showed that surface roughness increased with the argon ion dose. Water wetting angle of the ion beam treated samples increased with the ion dose, so the surface shows an ultra-hydrophobic nature. Micro-adhesion and micro-friction depend on the wetting characteristics of the PTFE samples. However, nano-tribological characteristics showed different results. The scale effect of surface topography on tribological characteristics was discussed. Also, the water wetting characteristics of modified PTFE samples were discussed in terms of the surface topographic characteristics.

Effects of Nozzle Diameter on Performance Characteristics for a Tangential Impeller-type Water Meter (접선류 임펠러형 수도미터의 노즐직경이 성능특성에 미치는 영향)

  • Suh, Sang-Ho;Lee, Byung-Ho;Cho, Min-Tae;Roh, Hyung-Woon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.3 s.4
    • /
    • pp.59-66
    • /
    • 1999
  • In this study the effects of nozzle diameter on the performance characteristics for the tangential impeller-type water meter are studied experimentally. The nozzle is cut along the tangential direction of the inner case in the water meter. The nozzle shape is round and the number of nozzles used for the experimental study are 8. The performance characteristics are discussed for various nozzle diameters such as 3.1, 3.3, 3.5, 4.0, 4.5 and 5.0 mm. Among the tangential impeller-type water meters, the water meter with the nozzle diameter of 5.0 mm shows the least pressure loss and the instrumental error compared to the Korean Standards.

  • PDF

Frictional Characteristics of Stainless Steel Ball Bearings Lubricated with Hot Water

  • Lee, Jae-Seon;Kim, Jong-In;Kim, Ji-Ho;Park, Hong-Yune;Zee, Sung-Qunn
    • KSTLE International Journal
    • /
    • v.4 no.2
    • /
    • pp.43-46
    • /
    • 2003
  • Water-lubricated frictional characteristics of a stainless steel ball bearings are not well known compared to the oil-lubricated frictional characteristics. Furthermore a study on friction at a high temperature is rare because the bearing maintenance strategy for water-lubricated or chemicals-lubricated bearings of equipment is generally based on the replacement of the failed bearings-and parts. Ball bearings and ball screw are installed in the power transmission for the newly developing integral reactor and these are lubricated with chemically-controlled pure water at a high temperature and a high pressure. Bearings and power transmitting mechanical elements for an atomic reactor requires high reliability and high performance during the estimated lifetime, and it should be verified. In this paper, experimental research results of the frictional characteristics for water-lubricated ball bearings are presented as a preliminary investigation.

Water Tree Growing and Electrical breakdown Characteristics of XLPE/XLPE blends (XLPE/SXLPE 블랜드의 수트리 성장 및 절연파괴 특성)

  • 고정우;서광석
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.420-425
    • /
    • 2000
  • Crosslinked polyethlyene/silane crosslinked polyethylene(XLPE/SXLPE) blends were prepared by a twin screw extruder and their water tree growing electrical breakdown and crossinking characteristics were investigated. The water tree characteristics of XLPE were improved by the addition of SXLPE when samples were crosslinked only by the thermorolysis of DCP (dicumyl peroxide). However steam curing process was not good for water tree characteristics. It was also found that the rate of water tree growing of XLPE/SXLPE blend increased when the content of SXLPE was 50%. AC breadown strength slightly increaed by the addition of SXLPE to XLPE when samples were crosslinked only by the thermorolysis of DCP. It was also found that the degree of crosslinking of XLPE/SXLPE blends were higher than that of XLPE in the case of the content without steam crosslinking process.

  • PDF

A Study on Characteristics of Surface Water and Soil in Wangdungjae Wetland Located at Chiri-Mountain (지리산 왕등재 습지의 지표수 수질 및 토양 환경조사)

  • Kim, Jong-Oh;Lee, Chang-Ho;Ji, In-ju
    • Journal of Wetlands Research
    • /
    • v.3 no.1
    • /
    • pp.61-73
    • /
    • 2001
  • This study was performed to survey the characteristics of surface water and soil in Wangdungjae wetland located at Chiri-Mountain. The results of survey summarized as follows; 1. The physico-chemical characteristics of surface water such as pH, temperature, and DO were in the range of 6.02-6.39, $13.5-24.3^{\circ}C$ and 3.81-9.97 mg/L, respectively. Also, the organic concentrations such as BOD and COD were in the range of 1.3-1.61 mg/L and 3.55-9.97 mg/L, respectively. The water quality of five different sampling sites showed the similar characteristics. 2. The physico- chemical characteristics of soil showed the different properties with the soil sampling depth. According to increasing sampling depth, cation exchange capacity (CEC) and electric conductivity (EC) increased but pH decreased. 3. The future survey and researches on surface water and soil environments are needed to preserve the Wangdungjae wetland at Chiri-mountain marsh.

  • PDF

Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber (미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석)

  • Sumon, S.M.;Lee, S.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

Water demand forecasting at the DMA level considering sociodemographic and waterworks characteristics (사회인구통계 및 상수도시설 특성을 고려한 소블록 단위 물 수요예측 연구)

  • Saemmul Jin;Dooyong Choi;Kyoungpil Kim;Jayong Koo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.363-373
    • /
    • 2023
  • Numerous studies have established a correlation between sociodemographic characteristics and water usage, identifying population as a primary independent variable in mid- to long-term demand forecasting. Recent dramatic sociodemographic changes, including urban concentration-rural depopulation, low birth rates-aging population, and the rise in single-person households, are expected to impact water demand and supply patterns. This underscores the necessity for operational and managerial changes in existing water supply systems. While sociodemographic characteristics are regularly surveyed, the conducted surveys use aggregate units that do not align with the actual system. Consequently, many water demand forecasts have been conducted at the administrative district level without adequately considering the water supply system. This study presents an upward water demand forecasting model that accurately reflects real water facilities and consumers. The model comprises three key steps. Firstly, Statistics Korea's SGIS (Statistical Geological Information System) data was reorganized at the DMA level. Secondly, DMAs were classified using the SOM (Self-Organizing Map) algorithm to consider differences in water facilities and consumer characteristics. Lastly, water demand forecasting employed the PCR (Principal Component Regression) method to address multicollinearity and overfitting issues. The performance evaluation of this model was conducted for DMAs classified as rural areas due to the insufficient number of DMAs. The estimation results indicate that the correlation coefficients exceeded 0.9, and the MAPE remained within approximately 10% for the test dataset. This method is expected to be useful for reorganization plans, such as the expansion and contraction of existing facilities.

Micro EDM Milling Using Deionized Water as Dielectric Fluid (탈수이온수를 절연액으로 사용한 미세 방전 밀링)

  • Chung, Do-Kwan;Kim, Bo-Hyun;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.546-549
    • /
    • 2005
  • Micro EDM milling using deionized water as dielectric fluid was investigated. After machining micro grooves using deionized water with different voltage. capacitance. and resistivity of deionized water, machining characteristics were investigated. The wear of a tool electrode and the machining time can be reduced by using deionized water instead of kerosene. Micro hemispheres were machined in deionized water and kerosene and their machining characteristics were compared.

  • PDF

A Study on Spray Characteristics of Water Mist Nozzle with Mid-low Pressure for Fire Suppression (화재용 중저압 물분무 노즐의 분무특성에 관한 연구)

  • 김성찬;유홍선;박현태;방기영
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.28-32
    • /
    • 2003
  • The present study investigates the spray characteristics of water mist nozzle with mid-low pressure for fire suppression. The examined nozzle types are swirl and spiral nozzle. The result shows that K factor of water mist nozzle is much smaller than those of general sprinkler. Spray angle of spiral nozzle is largest and more than $150^{\circ}$. SMD(Sauter Mean Diameter) of water mist nozzles is ranged between 100 and 200$\mu\textrm{m}$through measuring by image processing method. The spray pattern of spiral nozzle represent that water flux of first stream is 2 times larger than that of second stream. This study will contribute better understandings of the water-mist spray characteristics and useful daia for developing the water-mist nozzles.