• Title/Summary/Keyword: Water's view

Search Result 378, Processing Time 0.03 seconds

The study about usefulness of utilizing self-development jaw lift tool in pediatric Revers water's view (자체 개발한 하악거상 기구를 활용한 소아 REVERS WATER'S View의 유용성)

  • Kim, Kang-Hwan;Son, Soon-Lyong;Kim, Kwang-Soo;Hong, Sun-Suk;Lee, Kwan-Sup
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • This study is to provide clinical data when reverse-water's-view was carried out about pediatric who did not communicate by applying self-development jaw lift tool. This study were conducted in a subject of 23 children who examined revers-water's-view from 2013 July 6 to 2013 August 5 at our hospital. Two group time which were carried out revers-water's with tool and without tool were measured. also, Image of two group were evaluated. Evaluation data obtained by measuring the average difference were analyzed by independent-t-test. After apply self-development-jaw-lift-tool, time was reduced by 35.2%(36.6sec). the results indicated significant differences(p< .05). Image evaluation was increase 43.5%(1.03point), It was statistically highly significant difference (p< .01). If apply self-development-jaw-lift-tool in pediatric revers-water's-view, operator can provide fast, convenience, high quality image to pediatric.

  • PDF

Determination of Appropriate Exposure Angles for the Reverse Water's View using a Head Phantom (두부 팬텀을 이용한 Reverse Water's View에 관한 적절한 촬영 각도 분석)

  • Lee, Min-Su;Lee, Keun-Ohk;Choi, Jae-Ho;Jung, Jae-Hong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.187-195
    • /
    • 2017
  • Early diagnosis for upper facial trauma is difficult by using the standard Water's view (S-Water's) in general radiograph due to overlapping of anatomical structures, the uncertainty of patient positioning, and specific patients with obese, pediatric, old, or high-risk. The purpose of this study was to analyze appropriate exposure angles through a comparison of two different protocols (S-Water's vs. reverse Water's view (R-Water's)) by using a head phantom. A head phantom and general radiograph with 75 kVp, 400 mA, 45 ms 18 mAs, and SID 100 cm. Images of R-Water's were obtained by different angles in the range of $0^{\circ}$ to $50^{\circ}$, which adjusted an angle at 1 degree interval in supine position. Survey elements were developed and three observers were evaluated with four elements including the maxillary sinus, zygomatic arch, petrous ridge, and image distortion. Statistical significant analysis were used the Krippendorff's alpha and Fleiss' kappa. The intra-class correlation (ICC) coefficient for three observers were high with maxillary, 0.957 (0.903, 0.995); zygomatic arch, 0.939 (0.866, 0.987); petrous ridge, 0.972 (0.897, 1.000); and image distortion, 0.949 (0.830, 1.000). The high-quality image (HI) and perfect agreement (PA) for acquired exposure angles were high in range of the maxillary sinus ($36^{\circ}-44^{\circ}C$), zygomatic arch ($33^{\circ}-40^{\circ}$), petrous ridge ($32^{\circ}-50^{\circ}$), and image distortion ($44^{\circ}-50^{\circ}$). Consequently, an appropriate exposure angles for the R-Water's view in the supine position for patients with facial trauma are in the from $36^{\circ}$ to $40^{\circ}$ in this phantom study. The results of this study will be helpful for the rapid diagnosis of facial fractures by simple radiography.

A Study on Projection Angles for an Optimal Image of PNS Water's View on Children (유.소아 부비강 Water's 영상의 이상적 구현을 위한 촬영기준각도 변화에 관한 연구)

  • Son, Sang-Hyuk;Song, Young-Geun;Kim, Sung-Kyu;Hong, Sang-Woo;Kim, Je-Bong
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • This study is to calculate the proper angle for the optimal image of PNS Water's view on children, comparing and analyzing the PNS Water's projection angles between children and adults at every age. This study randomly selected 50 patients who visited the Medical Center from January to May in 2005, and examined the incidence path of central ray, taking a PNS Water's and skull trans-Lat. view in Water's filming position while attaching a lead ball mark on the Orbit, EAM, and acanthion of the patients's skull. And then, we calculated the incidence angles(Angle A) of the line connected from OML and the petrous ridge to the inferior margin of maxilla on general(random) patients's skull image, following the incidence path of central ray. Finally, we analyzed two pieces of the graphs at ages, developing out the patients' ideal images at PNS Water's filming position taken by a digital camera, and calculating the angle(Angle B) between OML and IP(Image Plate). The angle between OML and IP is about $43^{\circ} in 4-years-old children, which is higher than $37^{\circ}, as age increases the angle decreases, it goes to $37^{\circ} around 30 years of age. That is similar result to maxillary growth period. We can get better quality of Water's image for children when taking the PNS Water's view if we change the projection angles, considering maxillary growth for patients in every age stage.

  • PDF

Air-Water Two-Phase Flow Test Facility of a Single Stage Closed-type Centrifugal Pump (단단 밀폐형 원심펌프의 기액이상류 성능시험 설비)

  • Kim, S. Y.;Lee, S. L.;Kim, Y. T.;Kim, S. D.;Lee, Y. S.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.49-53
    • /
    • 2004
  • LabVIEW is mostly preferred to use in experiment, measurement and control as one of the useful thing in America and Europe. So, We tried performance experiment of a single-stage closed-type centrifugal pump by using the LabVIEW. The pump rpm and the shaft torque are measured by rpm sensor and torque sensor The test pump's maximum rpm, head, kW are 1,750, 13m, and 1.5kW, respectively The casing is made up with transparency acrylic for confirmation the flow patterns. We installed experimental equipment for air water two phase flow. This paper tries to analyze the single-phase flow characteristics through this air water two phase flow experimental apparatus. The performance results of a single-stage closed-type centrifugal pump satisfied reappearance and coincide well with head and coefficients according to the change of rpm.

  • PDF

12 Cases of Paranasal Sinusitis by Oriental Medicine (비연질환(부비동질환)鼻淵疾患(副鼻洞疾患)의 한방치험(韓方治驗) 12례(例))

  • Kim, Joong-Ho;Kim, Yoon-Bum;Chae, Byung-Yoon
    • The Journal of Korean Medicine
    • /
    • v.15 no.2 s.28
    • /
    • pp.113-121
    • /
    • 1994
  • We report 12 cases of paranasal sinusitis by the treatment of oriental medicines. Showing discharge from the nose. paranasal sinusitis is termed BIYEON(鼻淵) in the oriental medicine. Most of patient took GAMIBANGPUNGTONGSEONGSAN(加味防風通聖散). reported effect of antiphlogosis. antihistamine and antibiosis, for about five months. As a result the symptoms of paranasal sinusitis subsided. The radiographic diagnosis of sinusitis is generally based on opacification of the paranasal sinuses. Most of patients change the opacity of the maxillary sinuses on X-ray film in Water's view and Caldwell view by the treatment of Oriental medicine. We conclud that herbal medicines effect paranasal sinusitis.

  • PDF

A Study on Water Network Modeling System Based Upon GIS (지리정보시스템 기반의 상수관망 모델링 시스템 연구)

  • Kim, Joon-Hyun;Yakunina, Natalia
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.3
    • /
    • pp.315-321
    • /
    • 2010
  • ArcView and water network models have been integrated to develop the water network modeling system based upon GIS. To develop this system, pre, main, and post processing systems are required. GIS programming technique was adopted by using the ArcView's script language Avenue. The input data of models have been prepared by using the AutoCAD Map3D through the conversion of modeling input data to GIS data for A city. The modeling has been implemented by using EPANET, WaterCAD, InfoWorks. To develop the post processing system, the modeling results of the water network models have been analyzed by using GIS. During the application process of the developed system to B city with 300,000 population, main problems were found in the constructed GIS DB of that city. Thus, pilot study area of B city has been constructed, and pre-, main, and post-processing techniques were invented based upon GIS. Finally, the problems related to waterworks GIS projects in Korea were discussed and solutions were suggested.

Analysis of Flood Inundation using GIS (GIS를 이용한 홍수범람 분석)

  • Shim, Soon-Bo;Kim, Joo-Hun;Lim, Gwang-Seop;Oh, Deuk-Keun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.1
    • /
    • pp.132-142
    • /
    • 2003
  • A significant deficiency of most computer models used for stream floodplain analysis, is that the locations of structures impacted by flood waters, such as roads, buildings, and bridges, cannot be effectively compared to the floodplain location. The purpose of this study is the integration of the HEC River Analysis System(HEC-RAS) with ArcView geographic information system to develop a regional model for floodplain determination and representation. Also this study presents to enable two- and three-dimensional floodplain mapping and analysis in the ArcView. The methodology is applied to a Yeoju of Kyunggi-do, located in South Han River Basin. A digital terrain model is synthesized from HEC-RAS cross-sectional data and a digital elevation model of the study area. The flood plain data developed in ArcView was imported into HEC-RAS where it was combined with the field surveyed channel data in order to construct full floodplain cross sections that reflected accurate channel and overbank data for the HEC-RAS model. The flood plain limits could be expressed more accurately on ArcView by using water level data to be computed in HEC-RAS program. The computed water surface elevations and information of cross-section must be manually plotted in order to delineate floodplains. The resulting of this study provided a good representation of the general landscape and contained additional detail within the stream channel. Overall, the results of the study indicate that GIS combined with HEC-RAS is proven to be very useful and efficient for the automatic generation of flood maps, and an effective environment for floodplain mapping and analysis.

  • PDF

Study on the Layout of Water Diversion Projects Influenced by China's Macro Developing Strategies

  • Peng, Xiang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.59-66
    • /
    • 2008
  • A country's macro developing strategies will greatly impose upon its water resources allocation. Based upon the relationship between national macro developing strategies and water diversion projects layout, the paper discusses the vital influence of water diversion projects caused by China's food security and sustainable development strategy implemented in recent years, and points out that it is an inevitable choice of constructing inter-basin water diversion projects in north China in view of local water resources can't meet the demand of socio-economic development and eco-environment protection, and then recommends China's water diversion projects layout in the current and future, which attaching most importance to the South-to-North Water Diversion Project.

  • PDF

A RADIOGRAPHIC STUDY OF EXPERIMENTALLY PRODUCED BONE DEFECTS IN THE POSTERIOR WALL OF THE MAXILLARY SINUS (상악동 후벽의 실험적 골결손부에 관한 방사선학적 연구)

  • Choi Eui-Hwan;Park Won-Kyl
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.153-163
    • /
    • 1996
  • The purpose of this study was to evaluate the ability of radiographs in detecting experimental bony defect in the posterior wall of the maxillary sinus. For this study, experimentally five skulls were used, the bony defects with a diameter of 5mm were created at different locations in the posterior wall of the right maxillary sinus and the bony defects of 10mm were created at different locations in the posterior wall of th maxillary sinus. Panoramic view, panoramic sinus view, water's view, and computed tomogram were taken and the results analyzed. The obtanined results were as follows: 1. The panoramic view was superior to the panoramic sinus view in detecting the bony defects in the posterior wall of the maxillary sinus. 2. Panoramic view, panoramic sinus view, and waters's view were limitation to the detection of the bony defects in the posterior wall of the maillary sinus. 3. All the bony defects in the posterior wall of the maxillary sinus were excellently visualized on the computed tomogram.

  • PDF

Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System

  • Cho, Jin Dong;Park, Jong Min;Choi, Chang Heon;Kim, Jung-in;Wu, Hong-Gyun;Park, So-Yeon
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.190-196
    • /
    • 2017
  • For the $ViewRay^{(R)}$ system (ViewRay Inc., Cleveland, OH, USA) which is representative of magnetic resonance (MR) guided radiotherapy machine, it is important to evaluate effectiveness of AAPM's TG-51 protocol and the effect of the magnetic field on absolute dosimetry. In order to measure the absolute dose, MR-compatible chamber and water phantom system manufactured in this study were used. The materials of the water phantom system were plastic of polymethyl methacrylate (PMMA) and non-ferrous materials. Due to the inherent feature of the $ViewRay^{(R)}$, all Co-60 sources are not located at gantry angle of $0^{\circ}$ while being located at gantry angle of $90^{\circ}$. For this reason, absolute dosimetry was performed based on the measurements in solid water phantom (SWP) and water which determine the SWP to water correction factor. For evaluation of output constancy with gantry angle, measurements were made with ionization chamber inserted in cylindrical water-equivalent phantom. For measured doses in water, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -0.27%, -0.45% and -0.22%, respectively. For measured doses in SWP, the values of dose deviation according to a reference dose of 200 cGy for Head 1, Head 2 and Head 3 were -1.91%, -2.07% and -1.84%, respectively. All values of dose measured in SWP tended to be less than those measured in water by -1.63%. With the reference gantry angles of $0^{\circ}$ and $90^{\circ}$, the maximum values of deviation for Head 1, Head 2 and Head 3 were 0.48%, 1.06% and 0.40%, respectively. The measurement agreement is within the range of results obtainable for conventional treatment machines. The low strength of the magnetic field does not affect dose measurements. Using the SWP to water correction factor, absolute doses for $ViewRay^{(R)}$ system can be measured.