• Title/Summary/Keyword: Wastewater treatment systems

Search Result 281, Processing Time 0.032 seconds

A System Dynamics Model to Analyze the Effects of Investments for Improvement of Environmental Conditions in Nak-Dong River Basin (낙동강 유역 환경개선 투자 효과 분석을 위한 시스템다이내믹스 모델)

  • Park, Suwan;Kim, Kimin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.561-569
    • /
    • 2016
  • In this paper a concept of the paradigm shift in the operations of Water and Wastewater systems regarding the production and usage of water was introduced. Based on this concept the interrelationships between the water quality in the upper basin of NakDong River relative to Busan and the degree of satisfaction of the customers on the water supply service in Busan were modeled using the System Dynamics modeling methodology. SamRangJin basin area was determined as the upper basin of Busan after analyzing the relationships between the water quality of MoolGeum water intake point and water quality data of various mid- and upper water intake points along NakDong River. The amount of contaminants generated in SamRangJin basin was modeled using the Gross Regional Domestic Product in the area and the treated amount was calculated using the efficiency of wastewater treatment and the degree of improvement of environmental condition per investment. The water quality at MoolGeum water intake point was modeled to take the effects of the remaining amount of contaminants after treatment and the non-point source contaminants in SamRangJin basin. Using the developed System Dynamics model the effects of the investment for the improvement of environmental condition in SamRangJin basin were compared to the case of alternate water source development for Busan in terms of the degree of satisfaction of the customers on the water supply service in Busan.

Status of Constructed Wetlands in Nepal: Recent Developments and Future Concerns (네팔에서의 인공습지 적용: 최근 개발 및 향후 고려사항)

  • Gurung, Sher Bahadur;Geronimo, Franz Kevin F.;Lee, Soyoung;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2017
  • Nepal is a landlocked mountainous country in South Asia, located between China to the north and India to the south, east, and west. As such, wastewater management has become one of the most significant problems in urban area of Nepal. In Nepal, the centralized wastewater treatment systems were dysfunctional due to high cost of operation, discontinuous power supply, lack of proper maintenance and proper technical workforce to address the issues. As such, constructed wetlands (CW) were applied to treat various secondary wastewater as alternative to wastewater treatment facilities. Generally, efficiency and sustainability of CW technology depends on proper operation and maintenance and active community involvement. This study summarizes information about 26 CW in Nepal. Specifically, factors including data banking, removal efficiency, quality of discharged water, compliance to water quality standard of Nepal and operation and maintenance were investigated. Considering removal efficiency per pollutant, Ka-1 achieved the greatest reduction for most pollutant followed by B-1, L-3, Ka-5 and K-1. Nepal has practiced CW technology for more than 2 decades but currently, development of technology was interrupted by the inefficient performance of existing facilities. Public awareness about the technology, natural disaster, unavailability of specified substrate materials, lack of fund for further research and experiments has hindered the expansion of technology. In spite of these concerns, CW was still proven as an alternative solution to the present wastewater problems in urban areas of Nepal.

Water Digital Twin for High-tech Electronics Industrial Wastewater Treatment System (I): e-ASM Development and Digital Simulation Implementation (첨단 전자산업 폐수처리시설의 Water Digital Twin(I): e-ASM 모델 개발과 Digital Simulation 구현)

  • Shim, Yerim;Lee, Nahui;Jeong, Chanhyeok;Heo, SungKu;Kim, SangYoon;Nam, KiJeon;Yoo, ChangKyoo
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.63-78
    • /
    • 2022
  • Electronics industrial wastewater treatment facilities release organic wastewaters containing high concentrations of organic pollutants and more than 20 toxic non-biodegradable pollutants. One of the major challenges of the fourth industrial revolution era for the electronics industry is how to treat electronics industrial wastewater efficiently. Therefore, it is necessary to develop an electronics industrial wastewater modeling technique that can evaluate the removal efficiency of organic pollutants, such as chemical oxygen demand (COD), total nitrogen (TN), total phosphorous (TP), and tetramethylammonium hydroxide (TMAH), by digital twinning an electronics industrial organic wastewater treatment facility in a cyber physical system (CPS). In this study, an electronics industrial wastewater activated sludge model (e-ASM) was developed based on the theoretical reaction rates for the removal mechanisms of electronics industrial wastewater considering the growth and decay of micro-organisms. The developed e-ASM can model complex biological removal mechanisms, such as the inhibition of nitrification micro-organisms by non-biodegradable organic pollutants including TMAH, as well as the oxidation, nitrification, and denitrification processes. The proposed e-ASM can be implemented as a Water Digital Twin for real electronics industrial wastewater treatment systems and be utilized for process modeling, effluent quality prediction, process selection, and design efficiency across varying influent characteristics on a CPS.

Effects of Heat Pre-Treatment and Reactor Configurations on the Anaerobic Treatment of Volatile Solids (열전처리와 반응조 형태가 고형 유기물의 혐기성 처리에 미치는 영향)

  • Hong, Young-Soek;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.104-116
    • /
    • 1996
  • Anaerobic digestion is generally used for the treatment of volatile organic solids such as manure and sludge from waste water treatment plants. However, the reaction rate of anaerobic process is slow, and thus it requires a large reactor volume. To minimize such a disadvantage, physical and chemical pre-treatment is generally considered. Another method to reduce the reactor size is to adopt different reactor system other than CSTR. In this paper, the effects of heat pre-treatment and reactor configurations on the anaerobic treatability of volatile solids was studied. Carrot, kale, primary sludge, and waste activated sludge was chosen as the test materials, and the BMP method was used to evaluate the maximum methane production and first order rate constants from each sample. After the heat treatment at $130^{\circ}C$ for 30min., the measured increase in SCOD per gram VS was up to 394 mg/L for the waste activated sludge. However, the methane production potential per gram VS was increased for only primary and waste activated sludge by 17-23%, remaining the same for carrot and kale. The overall methane production process for the tested solids can be described by first order reactions. The increased in reaction constant after heat pre-treatment was also more significant for the primary and waste activated sludge than that for carrot and kale. therefore, the heat pre-treatment appeared to be effective for the solids with high protein contents rather than for the solids with high carbohydrate contents. Among the four reactor systems studied, CSTR, PFR, CSTR followed by PFR, and PFR with recycle, CSTR followed by PFR appeared to be the best choice considering methane conversion rate and the operational stability.

  • PDF

Removal Efficiency of Settleable Solids in Seawater Aquaculture Farm Wastewater (하이드로싸이클론을 이용한 해수 양식장 침전 고형물의 제거 효율 평가)

  • Junhyuk Seo;Pyongkih Kim;Jeonghwan Park
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.1
    • /
    • pp.116-123
    • /
    • 2023
  • Flow-through aquaculture systems generate large amounts of wastewater containing compounds such as solids that can settle near aquafarms and cause eutrophication. The settled solids are often reintroduced into flow-through systems, and aquatic animals can be affected by the solids and pathogens associated with these solids. For a sustainable aquaculture operation, adequate wastewater treatment is required. Hydrocyclones are one of the most promising technologies for the removal of solids in aquaculture wastewater. In this study, a model for performance prediction of hydrocyclones was investigated under three different operating conditions: water temperature, solids concentration, and water inlet velocity. The synthetic solids solution was prepared using settled solids from abalone aquaculture farms. The daily solids removal rates of the tested hydrocyclones ranged from 0.18 to 26.0 g solids-m-3-day-1, and removal efficiency ranged from 5.1 to 34.4%. The inlet water velocity had the greatest effect on solids removal and hydrocyclone efficiencies. The following multiregression model equation was derived from the daily solids removal rate (g solids-m-3-day-1) results for water temperature (T, ℃), solids concentration (SS, mg-L-1), and tangential inlet water velocity (TIV, m-sec-1): daily solids removal rate: f(z)=4.465+0.809TIV-0.375T+0.217SS (r2=0.976).

Bacterial Community Shift during the Startup of a Full-Scale Oxidation Ditch Treating Sewage

  • Chen, Yajun;Ye, Lin;Zhao, Fuzheng;Xiao, Lin;Cheng, Shupei;Zhang, Xu-Xiang
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.1
    • /
    • pp.141-148
    • /
    • 2017
  • The oxidation ditch (OD) is one of the most widely used processes for treating municipal wastewater. However, the microbial communities in the OD systems have not been well characterized, and little information about the shift of bacterial community during the startup process of the OD systems is available. In this study, we investigated the bacterial community changes during the startup period (over 100 days) of a full-scale OD. The results showed that the bacterial community dramatically changed during the startup period. Similar to the activated sludge samples in other studies, Proteobacteria (accounting for 26.3%-48.4%) was the most dominant bacterial phylum in the OD system, but its relative abundance declined nearly 40% during the startup process. It was also found that Planctomycetes proliferated greatly (from 4.79% to 13.5%) and finally replaced Bacteroidetes as the second abundant phylum in the OD system. Specifically, some bacteria affiliated with genus Flavobacterium exhibited remarkable decreasing trends, whereas bacterial species belonging to the OD1 candidate division and Saprospiraceae family were found to increase during the startup process. Despite of the bacterial community shift, the organic matter, nitrogen, and phosphorus in the effluent were always in low concentrations, suggesting the functional redundancy of the bacterial community. Moreover, by comparing with the bacterial community in other municipal wastewater treatment bioreactors, some potentially novel bacterial species were found to be present in the OD system. Collectively, this study improved our understandings of the bacterial community structure and microbial ecology during the startup of a full-scale wastewater treatment bioreactor.

Eutrophication and Water Pollution Characteristics of the Kyongan Stream to Paltang Reservoir (경안천${\sim}$팔당호의 부영양화와 수질오염 특성)

  • Cho, Joo-Lae;Hwang, Soon-Jin;Cho, Kyung-Je;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.4 s.92
    • /
    • pp.387-394
    • /
    • 2000
  • Water pollution characteristics were investigated in the Kyongan stream and major inlet parts of Paltang Reservoir from April to July, 2000. Water quality in the Kyongan stream was extremly deteriorated by treated wastewater discharge at near sewage wastewater treatment plant (SWTP) located in the upstream, and it is likely to influence eutrophication of the lower part of the stream. Water quality of the Kyongan stream showed a typical hypertrophic condition. Influxed concentrations with $NH_4$ and SRP into the main stream from SWTP were declined precipitously as water flowed toward the lower part of the stream, and chlorophyll- a explosively increased in the midstream. Average concentrations of $NH_4$, SRP and chlorophyll-a in the main stream were $1,343\;{\mu}g\;N/l$, $1,779\;{\mu}g\;P/l$ and $188\;{\mu}g\;l$, respectively. Particularly, phosphorus load was very high, and its influence on the algal growth stimulation was remarkable. In comparison with the water quality inflowing into Paltang Resevoir, pollution status of the Kyongan stream was more worse than that in the Pukhan River and the Namhan River. The results of this study indicate that the management of point source, SWTP effluent, is urgent to mitigate eutrophication of Paltang Reservoir, and requires further necessary controls of inorganic phosphorus loading.

  • PDF

Optimization of a Single-Channel Pump Impeller for Wastewater Treatment

  • Kim, Joon-Hyung;Cho, Bo-Min;Kim, Youn-Sung;Choi, Young-Seok;Kim, Kwang-Yong;Kim, Jin-Hyuk;Cho, Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.4
    • /
    • pp.370-381
    • /
    • 2016
  • As a single-channel pump is used for wastewater treatment, this particular pump type can prevent performance reduction or damage caused by foreign substances. However, the design methods for single-channel pumps are different and more difficult than those for general pumps. In this study, a design optimization method to improve the hydrodynamic performance of a single-channel pump impeller is implemented. Numerical analysis was carried out by solving three-dimensional steady-state incompressible Reynolds-averaged Navier-Stokes equations using the shear stress transport turbulence model. As a state-of-the-art impeller design method, two design variables related to controlling the internal cross-sectional flow area of a single-channel pump impeller were selected for optimization. Efficiency was used as the objective function and was numerically assessed at twelve design points selected by Latin hypercube sampling in the design space. An optimization process based on a radial basis neural network model was conducted systematically, and the performance of the optimum model was finally evaluated through an experimental test. Consequently, the optimum model showed improved performance compared with the base model, and the unstable flow components previously observed in the base model were suppressed remarkably well.

The effect of organic matter on the removal of phosphorus through precipitation as struvite and calcium phosphate in synthetic dairy wastewater

  • Aleta, Prince;Parikh, Sanjai J.;Silchuk, Amy P.;Scow, Kate M.;Park, Minseung;Kim, Sungpyo
    • Membrane and Water Treatment
    • /
    • v.9 no.3
    • /
    • pp.163-172
    • /
    • 2018
  • This study investigated the effect of organic matter on the precipitation of struvite and calcium phosphate for phosphorus recovery from synthetic dairy wastewater. Batch precipitation experiments were performed to precipitate phosphorus from solutions containing $PO_4{^{3-}}$ and $NH_4{^+}$ by the addition of $Mg^{2+}$ and $Ca^{2+}$, separately, at varying pH, Mg/P and Ca/P molar ratios, and organic matter concentrations. Soluble total organic solids exhibited more inhibition to precipitation due to potential interaction with other dissolved ionic species involved in phosphorus precipitation. Xylan with low total acidity only exhibited significant inhibition at very high concentrations in synthetic wastewater (at up to 100 g/L). No significant inhibition was observed for Mg and Ca precipitation at relatively lower concentrations (at up to 1.2 g/L). MINTEQ simulations show that dissolved organic matter (DOM) as humic substances (HS) can cause significant inhibition even at relatively low concentrations of 0.165 g/L fulvic acid. However, scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis suggested that xylan altered the crystal structure of both precipitates and had caused the formation of smaller sized struvite crystals with slightly rougher surfaces This could be due to xylan molecules adhering on the surface of the crystal potentially blocking active sites and limit further crystal growth. Smaller particle sizes will have negative practical impact because of poorer settleability.

Removal Characteristics of Natural Organic Matter and Taste and Odor by Advanced Water Treatment Process around the Han River Water Supply System (한강수계 고도정수처리 공정에서의 유기물과 맛·냄새의 제거특성)

  • Jae-Lim Lim;Lee, Kyung-Hyuk;Kim, Seong-Su;Chae, Seon-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • The water treatment plants in Seoul Metropolitan Area, which are under Korea Water Resources Corporation(KOWACO)'s management, take water from Paldang Reservoir in Han River System for drinking water supply. There are taste and odor (T&O) problems in the finished water because the conventional treatment processes do not effectively remove the T&O compounds. As part of countermeasures for taste and odor control, KOWACO is planning to introduce advanced water treatment process such as ozone and GAC in near future. This study evaluated the removal characteristics of T&O and dissolved organic matter (DOM) to find design and operation parameters of advanced water treatment processes in a pilot-scale treatment plant. The GAC adsorption capacity for DOC in the two GAC system (GAC and $O_3$-GAC) at an EBCT of 14min was mostly exhausted after 9months. The differency of the removal efficiency of DOC between $O_3$-GAC and GAC increased with increasing operation time because the bioactivity in $O_3$-GAC process was enhanced by post-ozone process. Removal by conventional treatment was unable to reach the target TON(threshold odor number) of 3 but GAC systems at an EBCT(empty bed contact time) of 14 min were able to archive the target with few exception. During the high T&O episodes, PAC as a pretreatment together with GAC could be useful option for T&O control. However, substantial TON removal continued for more than two year (> 90,000 bed volumes). At the spiking of less concentration 26 to 61 ng/L in the influent of GAC systems, GAC absorber and $O_3$-GAC processes could meet the treatment target. The better spike control after 12 and 19 months of operation compared to that after 7 months of operation is a strong indication of biological control. The results presented in this study had shown that $O_3$-GAC process was found to be more effective for T&O control than GAC process. And the main removal mechanism in GAC systems were adsorption capacity and biodegradation.