• Title/Summary/Keyword: Wastewater treatment system

Search Result 998, Processing Time 0.029 seconds

Development of GIS System for Agriculture Reuse of Wastewater Resource (GIS를 이용한 농업용수 재이용 활용시스템 개발)

  • Kim, Hae-Do;Lee, Gwang-Ya;Jeong, Gwang-Geun;Lee, Jong-Nam
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.479-484
    • /
    • 2005
  • A GIS-based integrated system for reuse of effluent from wastewater treatment plants was developed in this study. The GIS-supported program classified attribute data which the effluent's quantity and quality and agricultural thematic map data according to the 5 big river basin area. From the database, showing the spatial variation of the water quality of the effluent, thereby proposing proper mitigation strategies over the watershed. Also, this system enables the users who is going to reuse the reclaimed water for their paddies to provide of all the wastewater treatment plant data and agricultural structures and thematic map data.

  • PDF

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

Disinfection Characteristic of Sewage Wastewater Treatment Using Solar Light/TiO2 Film System (태양광/광촉매를 이용한 오폐수 살균특성)

  • Cho Il-Hyoung;Lee Nae-Hyun;An Sang-Woo;Kim Young-Kyu;Lee Seung-Mok
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.677-688
    • /
    • 2006
  • Currently, the application of $TiO_2$ photocatalyst has been focused on purification and treatment of wastewater. However, the use of conventional $TiO_2$ slurry photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we studied that solar light/$TiO_2$ film system was designed and developed in order to examine disinfection characteristics of sewage wastewater treatment. The optimum conditions for disinfection such as solar light intensity, characteristic of sewage wastewater, amounts of $TiO_2$ and comparison of solar ligth/$TiO_2$ systems with UV light/$TiO_2$ system was examined. The results are as follows: (1) photocatalytic disinfection process with solar light in the presence of $TiO_2$ film more effectively killed total coliform (TC) than solar light or $TiO_2$ film absorption only. (2) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with remain resistant material. (3) The survival ratio of TC and residual ratio of organic material (BOD, CODcr) decreased with the increase of amounts of $TiO_2$. (4) TC survival ratio decreased linearly with increasing UV light intensity. (5) The disinfection effect of solar light/$TiO_2$ slurry system decreased more than UV light/$TiO_2$ film systems. (6) The disinfection reaction followed first-order kinetics. We suggest that solar light instead of using artificial UV light was conducted to investigate the applicability of alternative energy source in the disinfection of TC and the degradation of organic material.

Treatment of Seafood Wastewater Using AO$_2$ System with PU-AC Media (담체가 첨가된 AO$_2$공법을 이용한 수산물 가공폐수의 처리)

  • Lee, Soon;Park, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.6
    • /
    • pp.666-672
    • /
    • 2008
  • Feasibility of simultaneous removal of organic matter, nitrogen and phosphorus was evaluated by applying AO$_2$ system to treat wastewater from a seafood processing plant. Treatability test was conducted by incorporating activated sludge from municipal sewage treatment plant with PU-AC media. Inflow concentrations of COD, TN, and TP were 198$\sim$1,240 mg/L, 75$\sim$577.4 mg/L, and 2.2$\sim$53.5 mg/L, respectively. Average removal efficiencies and outflow concentration of COD, TN, and TP were 86.5%, 65.7 mg/L; 81.4%, 53.1 mg/L; and 80.6% 4.07 mg/L, respectively. Stable operation was possible by increasing organic matter, nitrogen, and phosphorus loading rate to seafood wastewater treatment system composed of anaerobic and aerobic reactors. Used PU-AC media was proved to be biodegradable in this AO$_2$ system by maintaining high biomass concentration in the PU-AC media.

Electrodialysis of metal plating wastewater with neutralization pretreatment: Separation efficiency and organic removal

  • Park, Yong-Min;Choi, Su-Young;Park, Ki-Young;Kweon, Jihyang
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.179-187
    • /
    • 2020
  • Electrodialysis has been applied for treatment of industrial wastewater including metal electroplating. The wastewater from metal plating industries contains high concentrations of inorganics such as copper, nickel, and sodium. The ions in the feed were separated due to the electrical forces in the electrodialysis. The concentrate compartment is exposed to the elevated concentrations of the ions and yielded inorganic precipitations on the cation exchange membranes. The presence of organic matter in the metal plating wastewater affects complex interfacial reactions, which determines characteristics of inorganic scale fouling. The wastewater from a metal plating industry in practice was collected and the inorganic and organic compositions of the wastewater were analyzed. The performance of electrodialysis of the raw wastewater was evaluated and the effects of adjusting pH of the raw water were also measured. The integrated processes with neutralization and electrodialysis showed great removal of heavy metals sufficient to discharge to aquatic ecosystem. The organic matter in the raw water was also reduced by the neutralization, which might enhance removal performance and alleviate organic fouling in the integrated system.

A Study about the Influence of Pollutant Load on Water Quality in a Small Stream Watershed (소하천의 오염부하량이 수질에 미치는 영향에 관한 연구)

  • Lee, Sang-Hoon;Cho, Wook-Sang
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.1
    • /
    • pp.9-19
    • /
    • 2001
  • An intensive watershed survey including water quality measurement of 6 times was carried out in order to find out the relationship between pollutant load and water quality in a small stream watershed where livestock wastewater is the main source of water pollution. The findings from the survey are as follows. 1) The number of livestock showed large disagreement among county office, myon, and insite survey. It is vital to check the data at the beginning of watershed survey. 2) The fluctuation of streamflow and water quality was so large depending on the day of measurement that it is essential to set up continuous telemetering system to get reliable data about delivery ratio of pollutants. 3) It was helpful for setting the priority of investigation to check water quality and quantity at several points along the stream after dividing the watershed into 5 drainage areas. 4) To control the livestock wastewater, especially in case of cows, it is necessary to have roof system and prevent overland flow from the ground. In case of pig farms, it is recommended to have public treatment system instead of private treatment system. The exact emission load of livestock wastewater was difficult to estimate, and requires more study.

  • PDF

A Study about Applicability of Treatment for Water Treatment Residual Sludge Using Crossflow Tubular Membrane System (정수장 배출수 처리를 위한 Crossflow 관형막 여과 공정의 운전 적용에 관한 연구)

  • Kim, Young Hoon;Kim, Kwan Yeop;Kim, Ji Hoon;Lee, Yong Soo;Lee, Eui Jong;Eom, Jung Yeol;Kim, Hyung Soo;Hwang, Sun Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • Many other countries have investigated the residual sludge treatment process to save the existing water resource and produce the high suspended solid concentration sludge. There are various methods for concentrating residual sludge, but the membrane system has received the most interest for its efficiency. The objective of this study was to evaluate the application of membrane filtration system for the residual sludge treatment. The experiment equipment was composed of Lab scale Crossflow tubular membrane filtration system. Generally, crossflow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, very low Crossflow velocity was used in this experiment. Results confirmed that suspended solid concentration of residual sludge could be concentrated to 57,000mg/L in low Crossflow velocity tubular membrane system,. This concentration can be directly injected into the dehydrator. Based on the results, we know that the Crossflow tubular membrane system should be replaced conventional residual sludge treatment system.

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF

Estimation of Greenhouse Gas Emissions and Environmental Assessment of Dye Wastewater Treatment Process (염색폐수 처리공정의 온실가스 배출량 산정 및 환경성 평가)

  • Shin, Choon-Hwan;Park, Do-Hyun
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1881-1888
    • /
    • 2014
  • Greenhouse gas (GHG) emissions from dye wastewater treatment processes were estimated by analysing their mass and energy balances, which were then used as baseline information for environmental assessment. The total GHG emissions from dye wastewater treatment plants were divided into direct emissions from the treatment processes and indirect ones from electricity usage. The amounts of $CO_2$, $CH_4$ and $N_2O$ emissions were calculated according to the Intergovernmental Panel on Clime Change (IPCC) guideline for the GHG target management system. For 3 years between 2011 and 2013, direct and indirect emissions were on average 8,742.7 and 7,892.0 Ton.$CO_2eq/year$, respectively, with the former exhibiting 52.6 %. Also, compared to 2012, in 2013, the eco-efficiency indicator by the GHG emissions was found to be more than 1, suggesting that environmental quality was effectively improved.

A pilot-scale study on a down-flow hanging sponge reactor for septic tank sludge treatment

  • Machdar, Izarul;Muhammad, Syaifullah;Onodera, Takashi;Syutsubo, Kazuaki
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.195-204
    • /
    • 2018
  • A pilot scale study was conducted on a down-flow hanging sponge (DHS) reactor installed at a sewage treatment plant in Banda Aceh, Indonesia for treatment of desludging septic tank wastewater. Raw wastewater with an average biochemical oxygen demand (BOD) and total suspended solids of 139 mg/L and 191 mg/L, respectively, was pumped into the reactor. Two different hydraulic retention times (HRTs, 3 h and 4 h) were investigated, equivalent to organic loadings of 1.11 and $0.78kg\;BOD/m^3/d$, respectively. The average BOD concentration in the final effluent was 46 and 26 mg/L at HRTs of 3 and 4 h, respectively. The concentration of retained sludge along the reactor height was 10.2-18.7 g VSS/L-sponge, and the sludge activities were 0.24-0.32 and 0.04-0.40 mg/g VSS/h for heterotrophs and nitrification, respectively. Values of water hold-up volume, dispersion coefficient, and number of tank in-series found from tracer studies of clean sponge and biomass-loaded sponge confirmed that growth of retained sludge on the sponge module improved hydraulic performance of the reactor. Adoption of the DHS reactor by this Indonesian sewage treatment plant would enhance the role of the current desludging septic tank wastewater treatment system.