• 제목/요약/키워드: Wastewater treatment process

검색결과 1,424건 처리시간 0.023초

침지식 중공사막을 결합한 Dynamic state 하수고도처리공정(KSMBR process)의 개발 및 현장적용평가 (Development and Field Application of the Advanced Wastewater Treatment process (KSMBR) by Hollow Fiber Submerged Membrane)

  • 김지연;서인석;김홍석;김연권;김병군;최창규;안효원;서완석;장문석
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.358-363
    • /
    • 2006
  • KSMBR process is dynamic state advanced wastewater treatment applied with Trisectional Aeration (TSA) mode combined with membrane. TSA was remodeled conventional intermittent aeration which was operated nonaeration-aeration. TSA operates nonaeration ($N_1$) - aeration (A) - nonaeration ($N_2$) in Trisectional Aeration Reactor (TAR). Organics of influent could be nearly consumed to denitrification without influence by remained DO in TAR and it could be operated about sludge return ratio of 1Q (influent base). The purpose of this study was to apply KSMBR to the full-scale plant and to evaluate efficiency of nitrogen and phosphorus removal and TSA operation. The result of this study, average CODcr/T-N and CODcr/T-P ratio were 7.8 and 59.6, respectively. BOD, TCODcr, SS, T-N, T-P, E-coli removal efficiency were 98.4, 95.2, 73.0, 69.6, 99.95 %, respectively. KSMBR obtained high removal efficiencies of C, N and P when it applied full-scale plant.

Impact of Current Density, Operating Time and pH of Textile Wastewater Treatment by Electrocoagulation Process

  • Hossain, Md. Milon;Mahmud, Md. Iqbal;Parvez, Md. Shohan;Cho, Haeng Muk
    • Environmental Engineering Research
    • /
    • 제18권3호
    • /
    • pp.157-161
    • /
    • 2013
  • Treatment of textile wastewater by the electrocoagulation (EC) process is being investigated by this experimental study. The objective of this experiment is to observe the efficiency of the EC process in removing chemical oxygen demand (COD) and turbidity. In this experiment an iron electrode is used in the EC process, and different working parameters such as pH, current density and operating time were studied in an attempt to achieve a higher removal capacity. The results show that the maximum COD removal occurred at neutral pH at operating time 30 min. COD and turbidity removal reaches at maximum, with optimum consumption of electrodes, between current density 85-95 $A/m^2$, and only trace amounts of metals were determined in the EC treated effluent.

Polyvinyl Alcohol 분해 공생 균주에 의한 염색 폐수 중의 PVA 제거

  • 김철기;최용진;이철우;임연택;류재근
    • 한국미생물·생명공학회지
    • /
    • 제25권1호
    • /
    • pp.89-95
    • /
    • 1997
  • The current processer of the textile wastewater treatment are mostly consisted of a combination of a physico-chemical and a biological treatment. The overall efficiency of these processes is, however, assessed to be fairly low. It is even worse during the summer season when temperature of the wastewater rises above 40$\circ $C. Therefore, a feasible process of the textile wastewater treatment which can work efficiently at higher temperatures was investigated in this work. We used a bench scale reactor consisted of one 4 liter anaerobic and one 8 liter aerobic tank, and the thermophilic symbiotic PVA degraders, Pasteruella hemolytica KMG1 and Pseudomonas sp. KMG6 that had been isolated in our laboratory. In the preliminary flask experiments, we observed that the thermophilic symbiotic PVA degraders could not grow in the wastewater substrate. Then, we isolated the mutant strains by acclimating the KMG1and KMG6 strains to the wastewater medium. The mutant symbionts (KMG1-1 and KMG6-1) were isolated through 6 times successive transfers into the fresh wastewater medium after 5 days culture for each. The mutant strains obtained grew well in the mixed medium composed of 75% wastewater and 25% synthetic medium, and supplemented with 0.5% PVA as a sole carbon source. During the culture for 14 days at pH 7.0 and 40$\CIRC $C, the bacteria assimilated about 89% of the added PVA. The symbionts degraded equally well all the PVA substrates of different molecular weight (nd=500~30000). In contrast to the flask experiments, in the reactor system the mutant strains showed very low levels of the PVA and COD removal rates. However, the new reactor system with an additional aerobic tank attained 82% removal rate of COD, 94% of PVA degradation and 71% of color index under the conditions of 5% inoculm on the tank 2, incubation temperature of 40$\circ $C, dissolved oxygen level of 2~3 mg/l and retention time of 30 hours. This result ensures that the process described above could be an efficient and feasible treatment for the PVA contained textile wastewater at higher temperatures.

  • PDF

분리막 및 슬러지 처리와 고도처리 기술·장비를 포함한 하·폐수 처리기술의 특허 조사·분석을 통한 기술개발 동향 (Trends of Technology Development through Investigation and Analysis of Domestic Patent Related to Wastewater Treatment Technology including Membrane, Sludge Treatment and Advanced Treatment Technology and Equipment)

  • 유호식;김지태
    • 멤브레인
    • /
    • 제27권5호
    • /
    • pp.375-388
    • /
    • 2017
  • 하 폐수 처리 기술은 종래 단순 오염물질 처리에서 에너지 및 자원 절약형의 고도처리 기술로 발전되고 있으며, 공공 수역으로의 오염 물질과 유독 물질 배출을 최소화하고 설치 운영의 효율성을 높이기 위해 IT 및 BT와 같은 다양한 기술을 접목한 융합형 기술로 진화하고 있다. 국내 하 폐수 처리기술의 발전 추이를 살펴보기 위해 등록된 특허기술을 수집 조사하여 연도별 부문별로 분류하여 분석하였다. 본고에서 2010년~2017년 5월 간의 관련된 특허 등록 내용을 생물학적 물리화학적 처리공정, 장치 및 기기, 소재 제재, 슬러지처리, 분리막, 공정제어기술 등 10개 분야의 42개 세부 영역으로 나누어 추세를 분석했다. 총 3,356건의 특허가 등록되었으며 2013년에 638건으로 최고치를 기록한 이후 다소 감소하여 연간 3~400여 건을 유지하고 있다. 등록된 특허 총 건수는 아직 다른 국가에 비해 적지는 않으나 공정 제어 및 기기 분야, 신개념 처리 기술과 같이 세계 시장을 선도할 수 있는 첨단 기술의 특허는 타 분야에 비해 미흡한 것으로 나타났다.

호기성 공동대사작용에 의한 판지폐수처리 - 현장 적용 테스트 - (The Treatment of Box-mill Wastewater Using Aerobic Cometabolism Process - Practical Plant Test -)

  • 조용덕;이상화
    • 상하수도학회지
    • /
    • 제20권1호
    • /
    • pp.128-137
    • /
    • 2006
  • This study aims at developing the practical technology in the treatment of box-mill wastewater using the aerobic co-metabolism principle. The conventional activated sludge method exhibited the removal efficiency of $TBOD_5$ and $TCOD_{Mn}$ as 30~50% and 40~50%, respectively. Color was rather increased by 30~130% because the conventional treatment under the aerobic condition did not induce the conversion of molecular structure of dyeing agents. Meanwhile, when the aerobic co-metabolism principle was applied to the same wastewater, the removal efficiency of $TBOD_5$ and $TCOD_{Mn}$ were obtained as 92~97% and 90~94%, respectively. In particular, color was significantly reduced down to 65~85%. The enhancement of treatment efficiency was ascribed to occur not only that the non-degradables were converted to the second substrates, but also that the enzyme activity was increased as MLVSS was kept 3000mg/l or more with the first substrates injected.

Application of Electrocoagulation for Printing Wastewater Treatment: From Laboratory to Pilot Scale

  • Thuy, Nguyen Thi;Hoan, Nguyen Xuan;Thanh, Dang Van;Khoa, Pham Minh;Tai, Nguyen Thanh;Hoang, Quang Huy;Huy, Nguyen Nhat
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.21-32
    • /
    • 2021
  • This study reports for the first time the application of electrocoagulation (EC) from laboratory to pilot scales for the treatment of printing wastewater, a hazardous waste whose treatment and disposal are strictly regulated. The wastewater was taken from three real printing companies with strongly varying characteristics. The treatment process was performed in the laboratory for operational optimization and then applied in the pilot scale. The weight loss of the electrode and the generation of sludge at both scales were compared. The results show that the raw wastewater should be diluted before EC treatment if its COD is higher than about 10,000 mg/L. Pilot scale removal efficiencies of COD and color were slightly lower compared to those obtained from the laboratory scale. At pilot scale, the effluent CODs removal efficiency was 81.9 - 88.9% (final concentration of 448 - 992 mg/L) and color removal efficiency was 95.8 - 98.6% (final level of 89 - 202 Pt-Co) which proved the feasibility of EC treatment as an effective pre-treatment method for printing wastewater as well as other high colored and hard-biodegradable wastewaters.

충청남도 마을하수처리시설의 최적 설치방안 (Alternatives for Optimum Installation of Rural Sewage Treatment Facilities in Chungchongnam-do Province)

  • 이상진;정종관;임봉수;허재영
    • 상하수도학회지
    • /
    • 제19권4호
    • /
    • pp.462-472
    • /
    • 2005
  • This study was carried out to suggest the plans for installation of rural sewage treatment facilities through the analysis of these facilities installed in Chungchongnam-do Province. About 5% of all installation was carried out by the department of wastewater and related environment problems and the other case was carried out by the department of construction or residence. In wastewater caused by 250 and 300 persons, facilities capacity do not exceed about $50m^3/d$, caused by 2,500 and 3,000 persons, $500m^3/d$. Advanced sewage treatment process were first needed in the discharge area where affected the water environment greatly. However, in carrying out the water quality pollutant of the total amount management system in the other areas, they should be driven only over the scale of pollutant quota object facilities standard. Rural sewage must be included in the special accounts according to the regulations of local government, and sewage treatment cost should be collected to manage. Installation type uses integrating joint treatment method in case the distance among villages is short or one treatment facility independently.

원전 일차계통 HyBRID 제염공정 발생 폐액 내 불순물 제거 및 분해 (Removal and Decomposition of Impurities in Wastewater From the HyBRID Decontamination Process of the Primary System in a Nuclear Power Plant)

  • 은희철;정준영;박상윤;박정순;장나온;원휘준;심지형;김선병;서범경
    • 방사성폐기물학회지
    • /
    • 제17권4호
    • /
    • pp.429-435
    • /
    • 2019
  • 원전 일차계통 HyBRID 제염공정에서 발생되는 제염폐액에는 황산이온과 방사성 핵종을 포함한 금속이온 및 발암성 물질의 하이드라진을 포함하고 있어 이를 안전한 수준으로 처리할 수 있는 기술개발이 필요하다. 본 연구에서는 모의 제염폐액내 황산 및 금속이온의 제거와 하이드라진의 분해시험을 실시하여 황산이온, 금속이온 및 하이드라진을 효과적으로 제거할 수 있는 HyBRID 제염폐액 처리공정을 도출하였으며, 1 L 규모에서의 반복실험과 Pilot 규모(300 L/batch)에서의 평가시험을 통해 도출한 HyBRID 제염폐액 처리공정의 성능 재현성과 적용성을 검증하였다.

활성슬러지 공정에 의한 Acetaldehyde 제조 공장 폐수의 처리 (Treatment of Wastewater from Acetaldehyde Plant by Activated Sludge Process)

  • 서승교;김정호;김영호
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.259-265
    • /
    • 1997
  • This study was conducted to Investigate the treatment of wastewater from acetaldehyde manufacturing plant by activated sludge process with Micrococcus roseus AW-6, Micrococcus roseus AW-22, Microbacterium lacticum AW-38 and Mlcrobacterium nae- vaniformans AW-41. The $COD_{Mn}$ and $BOD_5$ of the wastewater were 5, 260mg/L and 6, 452mg/L, respectively. pH was 1.85. The main organic component in the wastewater was acetic acrid which was contained 67, 600mg/L. Optimum dilution time for activated sludge process was shown 10 times. The specific substrate removal rate(BL) was 1.95day-1 and the nonbiodegradable matters(Sn) were 23.2mg/L. Saturation constant (Ks) and mainmum specific growth rate(qmax) were 1, 640mg/L and 2.33day-1, respectively. Sludge yield coefficient(Y) and endogenous respiration coefficient(kd) were 0.28mg MLVSS/mgCOD and 0.02day-1, respectively. $COD_{cr}$ removal efficiency was 91% for 1.95day of hydraulic retention time.

  • PDF