• 제목/요약/키워드: Wastewater treatment effluent

검색결과 677건 처리시간 0.026초

물옥잠을 이용한 수중처리방법에 의한 농공단지 폐수처리에 관한 연구 (Study on the Wastewater Treatment by Floating Aquatic Plant System Using Water Hyacinth for the Industrial Complex in Rural Area)

  • 윤춘경;김형중;류재현;여운식
    • 한국농공학회지
    • /
    • 제39권3호
    • /
    • pp.64-71
    • /
    • 1997
  • Floating aquatic plant system using water hyacinth was applied to examine feasibility as a wastewater treatment system for the industrial complex in rural area. The wastewater from the industrial complex does not likely contain toxic pollutants because the industries which generate wastewater with toxic compounds are not allowed to move in. Pilot plant was installed at Baeksuk Nongkong Danzi in Chunahn-City, Chunchungnam - Do , and field study was performed during summer and fall of 1996. Hydraulic loading rate was 0. $0.19m^3/m^2$.day. The effluent concentration of DO was higher than influent, and it implies that 0.6m depth reactor was reaerated enough to increase DO level. The influent concentration of BOD varied significantly from less than 30 to 120mg/${\ell}$ during the study period, however, effluent concentrations were generally lower than the water quality standard and removal efficiency was up to 85%. The influent concentration of COD also showed wide variation from less than 40 to 160mg/${\ell}$ and effluent concentration was higher than water quality standard when influent concentration was over l00mg/${\ell}$. The influent concentrations of T-N and T-P were lower than water quality standard and no further treatment was required, and these compounds were also removed in the system. Although some improvement and refinement are still required, overall* the floating aquatic plant system was proved to be feasible to apply to treat wastewater from industrial complex in rural area.

  • PDF

제올라이트를 첨가한 질산화 탈질공정에서 응집과 UF공정을 이용한 처리수내 용존 유기물질 제거 연구 (Study on Removal of DOC for Effluent from Nitrification and Denitrification Process with Zeolite by Combined Process of Coagulation and UF Membrane)

  • 한장혁;윤태일;조경철;송재용
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.537-546
    • /
    • 2005
  • This study was carried out to evaluate EPS and SMP variation of sludge and effluent in nitrification and denitrification process with zeolite addition, a possible reduction of effluent DOC by URC(Ultra Rapid Coagulation) process. As a biological wastewater treatment result, EPS formation of both aeration and anoxic sludges are not affect by SRT variation. However, EPS concentration of sludges is higher in aeration tank than in anoxic tank by 6~8 mg EPS/ g VSS. Linear relationship between SMP to DOC indicates that SMP of bulk solution contributes to most of the biological treatment effluent DOC. DOC and turbidity removal efficiency was more improved with URC process than in a conventional coagulation. For pretreatment of UF filtration DOC removal was advanced by URC process than only UF filtration.

하수처리장 방류수에 존재하는 항생제 내성인자가 하천에 미치는 영향 (Effect of antibiotic resistant factors in effluent of wastewater treatment plant on stream)

  • 장예진;유용재;설우준;차창준;이옥재;채종찬
    • 미생물학회지
    • /
    • 제53권4호
    • /
    • pp.316-319
    • /
    • 2017
  • 하수처리장 방류수와 하천 중의 항생제 내성인자 분포에 대한 상관성을 분석하기 위해 방류수와 상류 하천수, 하류 하천수를 대상으로 항생제 내성유전자와 전파 관련 유전자를 조사하였다. 3개 지점에서 134~183개의 항생제 내성유전자(ARG) 및 전파 관련 유전자(MGE)가 검출되었으며, 1개의 16S rRNA 유전자에 대한 ARG 및 MGE 유전자의 상대적인 총 합이 0.063~0.422 copy로 분석되었다. ARG와 MGE의 수와 존재량은 방류수에서 가장 높게 검출된 반면, 총 세균 수는 가장 적게 검출됨으로서 하수처리 과정에서 사멸된 세균에 포함된 유전자들이 검출된 것으로 판단된다. 또한 MGE의 존재량 양상이 ARG의 존재량과 상관관계를 보임으로서 항생제 내성균들의 내성기작이 자연내성보다는 획득내성일 가능성을 제시하였다.

K피혁폐수 처리시설에 대한 배출허용기준 평가 (Assessment of Effluent Limitation for K Leather Industry Wastewater)

  • 양형재;권오상;김재훈;이성종;정동일;김상훈
    • 환경위생공학
    • /
    • 제22권2호
    • /
    • pp.41-52
    • /
    • 2007
  • K leather industry wastewater treatment plant(advanced treatment process) was selected to evaluate effluent quality and pollutants removal efficiencies. $BOD_5$ concentration of effluent was $3.95mg/{\ell}$ and its removal efficiency was 99.8%. Also, most of other pollutants removal efficiencies were over 90% as well. And 95% reliability of effluent concentration were $106.8mg/{\ell}$ of CODmn, $86mg/{\ell}$ of SS, $72.04mg/{\ell}$ of TN that is greater than the effluent limitation, $0.98mg/{\ell}$ of ABS, $1.8mg/{\ell}$ of n-Hexane, $9.7mg/{\ell}$ of $BOD_5$ and $0.11mg/{\ell}$ of Cr.

간수+염화일철을 이용한 염색폐수 색도처리에 관한 연구 (A Study on Color Treatment of Dyeing Wastewater with Bittern+Iron(II) chloride)

  • 김만구;서명포
    • 한국염색가공학회지
    • /
    • 제12권3호
    • /
    • pp.218-223
    • /
    • 2000
  • Color removal of dyeing wastewater is becoming more important due to intensive limitation on color unit of effluent water, so this study was to investigate an efficient color removal of dyeing wastewater. We found that bittern+iron chloride(II) inorganic coagulant developed by Kabool research center is much higher than any other inorganic coagulants for color removal. Optimum pH of this coagulant was 10.5 and removed more than 90% for color removal efficiency. The results showed that COD and color unit of effluent water was average 60mg/L and 200~250 units when continuous activated sludge test after coagulation with this coagulant has done. From the results of the experiments, the application of bittern+iron chloride(II) inorganic coagulant can save the operating cost of wastewater treatment plants.

  • PDF

하수 유래 미량오염물질 현황과 관리 방안 고찰 (A review on status of organic micropollutants from sewage effluent and their management strategies)

  • 최상기;이웅배;김영모;홍석원;손희종;이윤호
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.205-225
    • /
    • 2021
  • Due to the large-scale production and use of synthetic chemicals in industralized countries, various chemicals are found in the aquatic environment, which are often termed as micropollutants. Effluents of municipal wastewater treatment plants (WWTPs) have been identified as one of the major sources of these micropollutants. In this article, the current status of occurrence and removal of micropollutants in WWTPs and their management policies and options in domestic and foregin countries were critically reviewed. A large number of pharmaceuticals, personal care products, and industrial chemicals are found in WWTPs' influent, and are only partially removed by current biological wastewater treatment processes. As a result, some micropollutants are present in WWTPs' effluents, which can negatively affect receiving water quality or drinking water source. To better understand and assess the potential risk of micropollutants, a systematic monitoring framework including advanced analytical tools such as high resolution mass spectrometry and bioanalytical methods is needed. Some Western European countries are taking proactive approach to controlling the micropollutants by upgrading WWTP with enahnced effluent treatment processes. While this enahnced WWTP effluent treatment appears to be a viable option for controlling micropollutant, its implementation requires careful consideration of the technical, economical, political, and cultural issues of all stakeholders.

활성슬러지공정 하수종말처리장의 분원성 지표세균의 농도 및 비교 (Enumeration and Comparison of Fecal Indicator Bacteria in a Sewage Treatment Plant Using Activated Sludge Process)

  • 이동근;성기문;정미라;박성주
    • 한국환경보건학회지
    • /
    • 제36권2호
    • /
    • pp.141-147
    • /
    • 2010
  • Indicator bacteria of fecal pollution were enumerated and compared by various detection methods for influent and final effluent of a sewage treatment plant. Total coliforms were enumerated by four methods including most probable numbers, chromogenic enzyme substrate test, membrane filtration, and plate counts and were about $10^4$ for influent and $10^2{\sim}10^3\;CFU/ml$ for final effluent. Fecal coliforms ranged between $10^3$ and $10^4$ for influent and $10^2\;CFU/ml$ for effluent by chromogenic enzyme substrate test and membrane filtration. Fecal streptococci counts were 1-log less than fecal coliforms counts, $10^2{\sim}10^3$ for influent and $10^1\;CFU/ml$ for effluent. Total coliforms numbers by plate count both in influent and in effluent showed 1-log higher than by the other three methods. Statistical analysis revealed that numbers of total coliforms by plate count in final effluent had the highest average of correlation (r=0.778, p<0.01) compared with those by the other three methods. In addition, total coliforms numbers by plate count showed most significant correlation (r=0.835, p<0.01) with those by chromogenic test which is well-known as its highest recovery efficiency. These results suggest that the plate count would be the optimum detection method for total coliforms in wastewater treatment plants which are the only microbiological standard of final effluent from wastewater treatment plants in the Republic of Korea, considering economic aspects and difficulties in laboratories.

Phenol 함유폐수의 처리를 위한 영향인자와 성능특성 (Influence factors and Efficiencies Characteristics for Treatment of Wastewater Containing Phenol)

  • 강선태;김정목
    • 상하수도학회지
    • /
    • 제10권4호
    • /
    • pp.119-126
    • /
    • 1996
  • Influence factors and efficiency characteristics for treatment of wastewater containing phenol were studied with using Pseudomonas sp. B3. It took 130 hours to remove phenol, when only activated sludge of terminal disposal palnt of sewage was innoculated in batch culture, but it was required just 36 hours, when bacteria degrading phenol and activated sludge were simultaneously innoculated. If only phenol an carbon source was used, it necessary 36 hours for biodegradation of phenol, while glucose was added to medium, it took 73 hours. It was revealed as excellent effluent and SVI, when the F/M ratio, COD and phenol concentration were 53mg/l and 1.2mg/l, respectively, and optimum F/M ratio was revealed 0.31. The reactor were seriously shocked as reducing hydraulic retention time at constant phenol concentration more than increasing phenol concentration at constant hydraulic retention time, when volumetric loading rate was increased to $0.8kg\;phenol/m^3{\codt}d$ from $1.6kg\;phenol/m^3{\codt}d$. And also the effluent phenol concentration was 34mg/l after starting 12 hours of shocking and reactor was recovered as steady state after 65 hours of changing in the former test. Although the effluent phenol concentration was maximum value with 12mg/l after starting 20 hours of shocking and reactor was recovered as steady state after 54 hours of changing in the later test.

  • PDF

슬러지 침전성이 DNR 공정에 미치는 영향 평가 (The Effect of Sludge Settleability on the Performance of DNR Process)

  • 서창원;란 티 뉴엔;정형석;이상민;이의신;신항식
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.273-280
    • /
    • 2006
  • The sludge settleability is a key factor for operating activated sludge process as well as BNR (biological nutrient removal) process, because the poor sludge settling causes an increase of suspended solid in the effluent. In order to improving the sludge settleability, a settling agent such as iron dust can be applied. In this study, the effect of sludge settleability on the performance of DNR (Daewoo nutrient removal) process was investigated with GPS-X, which is the popular wastewater treatment process model program, and the result of modeling was verified with operating lab-scale DNR process. As a result, if the sludge blanket keeps stable in the secondary settling tank, the effluent quality is similar in spite of different SVI values. And in case of the good sludge settleability, short HRT or long SRT increased the biomass concentration in the bioreactor, and improved the pollutant removal efficiency. In spite of daily influent changing, the good sludge settleability also guaranteed the stable effluent quality. And the results of the lab-scale DNR process experiment could support the simulated results.

고도처리공법이 적용된 하수처리시설에서의 공법적용의 적정성 평가 (Validity evaluation of wastewater treatment system applying advanced treatment processes)

  • 안준수;박태술;조정호
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.4055-4068
    • /
    • 2010
  • 본 연구는 고도처리공법을 적용하여 수년간 가동 중인 하수처리시설에 대한 운전현황을 측정 분석하여, 고도처리공법 적용의 적정성을 평가하고자 하였다. 단위공정별 처리효율은, BOD의 경우 1차침전지 35, 생물반응조 87, 최종방류수 48 %, T-N의 경우 1차침전지 18, 생물반응조 40, 최종방류수 25 %, T-P의 경우 1차침전지 23,, 생물반응조 38, 최종방류수25 % 등으로, 각 단위공정별로 양호한 처리효율을 나타내었다. 생물반응조 내의 미생물 관측 결과, 다양한 종류의 세균과 원생동물 및 후생동물이 관측되었고, 담체의 세균 부착기능이 안정적으로 유지되고 있음을 알 수 있었다. 최종방류수질은 BOD 5.5, COD 9.9, SS 4.6, T-N 11.8, T-P 0.99 mg/L으로 방류수 수질기준보다 낮은 양호한 수질상태를 나타내었다.