• Title/Summary/Keyword: Wastewater organic matter

Search Result 294, Processing Time 0.027 seconds

Swine wastewater treatment with soil microbes and its efficiency and dynamic parameters (토양미생물을 이용한 축산폐수 처리의 공정별 제거효율 및 동력학적 상수)

  • Park, Wan-Cheol;Shin, Nam-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 2000
  • Removal rate of swine wastewater containing organic matter was 99 percent in case of high loading rate. The studies of swine wastewater treatment aim to development of process using soil microorganism. Microorganism was devoted to improve the treatment efficiency of the process. Biochemical oxygen demand (BOD) concentration of treated swine wastewater was under 150 mg/L in anaerobic reactor. Also, value of km and Y were $0.73\;hr^{-1}$ and 0.433 g/VSS/g BODrm/d at microorganism of post aeration tank in anaerobic reactor.

  • PDF

Study in the integrated watershade management for conservation of water resources (II) - Water quality modeling and simulation of Oship stream - (수자원 보전을 위한 유역통합관리 방안에 관한 연구(II) - 오십천 수계의 수질모델링 및 수질 예측 -)

  • 허인량;정의호;권재혁
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.61-69
    • /
    • 2002
  • Oship stream is located nearby south eastern coasts. This study was performed to find out waters quality modeling and then to predict water quality of Oship stream. Based on survey data, BOD, T-N, T-P calibration and verification result were in good agreement with measured value within mean coefficient variance(MSE) value, which were 13.9%, 9.0%, 26.5% and 19.5%, 12.0%, 16.5%, respectively. Sectional water quality predictions of the main stream of Oship stream are executed on the basis of the following cases 1) with sewage treatment of Dogye-eup 2) reduction of mine wastewater treatment of 80% in th basin. As a result, BOD, T-P improvement rates at down stream of Oship stream, case 1) were appeared 12.2%, 22.2%, case 2) maximum sulfate ion and conductivity reduction removal rate of Oship stream were 58%, 68%. The main pollution sources of Oship-stream were almost domestic wastewater and mine wastewater discharged from Dogye-eup which located in uppers stream. The large effects will appear after the construction of Dogye sewage water treatment plant which remove the organic matter and nutrients in these sewage water. The waste water from mine can not easily to treat for characteristics of effluence and economic problems. However, to achieve the goal of water quality in Oship-stream water system, treatments of those are necessary.

Development of a Rotating Biological Contactor(RBC) Process for the Advanced Wastewater Treatment (회전원판(回轉圓板) 생물막(生物膜) 공법(工法)을 이용한 하(下)·폐수(廢水)의 고도처리(高度處理) 공정(工程) 개발(開發))

  • Kim, Eung Ho;Park, Jae Lo;Yoon, Jung Ro
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1994
  • This study was conducted to develop a new RBC process available for the effective removal of organic matters and nitrogen in sewage. The RBC process for the oxidation organic compounds and nitrification was designed to occur at the 1st-stage and next-stage RBC respectively. Then nitrified water was recycled to the denitrifying RBC located at the lower part of the 1st-stage RBC. Some results were summarized as follows. 1. The loading limitation was represented as $60g{\cdot}COD/gm^2/day$ in experiment of simultaneous removal of organic matter and nitrogen. The maxmum COD % removal was 85% at the load $35g{\cdot}COD/m^2/day$. 2. The $NO_3-N$ % removal was approximately 80% at the load $60g{\cdot}COD/m^2/day$ and the maximum $NO_3-N$ remaval rate was $3.9g{\cdot}COD/m^2/day$ and the overall C/N ratio of 11.0 as required to achive 80% of $NO_3-N$% removal. 3.$NO_3-N$ removal rate was rapidly decreased above the load $7g{\cdot}NH_4{^+}-N/m^2/day$ and the maximum $NO_3-N$ removal rate was $3.7g{\cdot}NO_3-N/m^2/day$. 4. Irrespective of the recycle ratio, the COD % removal at the system of 2-stage RBC unit was nearly constant as 89% while the maximum one in the 1st-stage unit was 77% in the case of 50% recycle. 5. The maximum COD % removal in the 3-stage RBC system was 93% while 1st-stage one being 80%, under the $NH_4{^+}-N$ load of $7.4g/m^2{\cdot}d$. Also maximum percentage of nitrification and denitrification was 69% and 41% respectively, under the same $NH_4{^+}-N$ load.

  • PDF

A Study on the Biosorption Process for Organic and Nutrient Removal from the Wastewater (생흡착을 이용한 하수의 유기물, 질소, 인제거에 관한 연구)

  • Kim, Hyun-Kab;Park, Ju-Seok;Chung, Hyung-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.470-479
    • /
    • 2004
  • The experimental conditions and relationships between parameters such as organic matter, aeration volume, aeration time, and precipitation time for the effective treatment of domestic wastewater were investigated. With the batch systems, the adsorption amount of unit microbe was measured with the change of MLSS concentration, precipitation time, and aeration amount. Theoretical adsorption amount of microbes was then numerically formulated by use of a SPSS multiple analysis as follows: $$Y=-0.0106(X_1)+0.07310(X_2)+42.705(X_3)+62.700$$ In this study, the amount of organisms to be removed in the range of MLSS concentration 2,000~4,500 mg/l were examined. In order to investigate the optimal condition of nitrification, the upper water in the biosorption stage was used as the initial experiment water. The results showed that the C/N ratio was 1.5 and the reaction time for the optimal nitrification was 1.5 hr. When the adsorption efficiency for microbe biosorption was 66%, the optimum denitrification efficiency was 83.3%. When the optimum parameters obtained from the batch experiment were applied to the lab-scale operation, the total retention time from the flow-in to flow-out was 10 hours and the removal efficiency was 93.8% for $COD_{cr}$ and 80.9% for TN. For the full-scale operation, the total retention time was 9.0 hours and the removal efficiency was 94.4% for BOD, 89.6% for $COD_{cr}$, 88.0% for TN, and 86.2% for TP.

An Overview of the Pretreatment Processes in Seawater Desalination Plants using Reverse Osmosis Membranes (역삼투막을 이용한 해수담수화 플랜트에서 전처리 공정 기술)

  • Ahn, Chang Hoon;Lee, Wonil;Yoon, Jeyong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.811-823
    • /
    • 2009
  • Seawater desalination process using a reverse osmosis (RO) membrane has been considered as one of the most promising technologies in solving the water scarcity problems in many arid regions around the world. To protect RO membrane in the process, a thorough understanding of the pretreatment process is particularly needed. Seawater organic matters (SWOMs) may form a gel layer on the membrane surface, which will increase a concentration polarization. As the SWOMs can be utilized as a substrate, membrane biofouling will be progressed on the RO membrane surface, resulting in the flux decline and increase of trans-membrane pressure drop and salt passage. In the middle of disinfection, an optimal chlorine dosage and neutralizer (sodium bisulfite, SBS) should be practiced to prevent oxidizing the surface of RO membranes. Additional fundamental research including novel non-susceptible biofouling membranes would be necessary to provide a guide line for the proper pretreatment process.

Reduced Post-Chlorine Dosage Required for Disinfection: Improvement with Ozonation and GAC Process (오존 및 입상활성탄 도입시 후염소 주입량 저감효과 분석)

  • Baek, Young-Ae;Joe, Woo-Hyeun;Kim, Jong-Moon;Choi, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.445-452
    • /
    • 2007
  • This study was carried out to examine effect of post-chlorine dosage reduction by ozonation and GAC process in the field plant for 3years in the "G" water purification plant in Seoul. And it is to compare GAC with BAC process in removal effects of TOC, THMs, THMFP, $UV_{254}$. As a result, chlorine dosage of ozonation and GAC(=BAC) is less demand than GAC. Seasonal reduction of chlorine demand is from about 37% to 59% with BAC, and from 24 to 46% with GAC. Higher reduction in BAC could be achieved. The efficiency of chlorine demand reduction with ozonation was depending on the organic carbon removal. $UV_{254}$ concentration is less about 0.13~0.74L/mg.m in BAC than GAC. Therefore, the combination of ozonation and GAC was more effective in reducing post-chlorine than the single GAC. TOC was also monitored, and results show that a linear relationship between TOC and chlorine demand is appropriate under each treatment process. It means that removal of organic matter(TOC) from finished water is necessary to reduce post-chlorine dosage in clear well and to minimize order of chlorine in distribution systems.

Characteristics of manganese removal by ozonation: Effect of existing co-ion and optimum dosage (오존을 이용한 용존성 망간 제거 특성: 공존이온의 영향 및 최적주입량)

  • Kwak, Yeonwoo;Lee, Seulki;Lee, Yongsoo;Hong, Seongho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.145-152
    • /
    • 2018
  • This study is focused on manganese (Mn(II)) removal by ozonation in surface water. Instant ozone demand for the water was 0.5 mg/L in the study. When 0.5 mg/L of Mn(II) is existed in water, the optimum ozone concentration was 1.25 mg/L with reaction time 10 minutes to meet the drinking water regulation. The ozone concentration to meet the drinking water regulation was much higher than the stoichiometric concentration. The reaction of soluble manganese removal was so fast that the reaction time does not affect the removal dramatically. When Mn(II) is existed with Fe, the removal of Mn(II) was not affected by Fe ion. However As(V) is existed as co-ion the removal of Mn(II) was decreased by 10%. Adding ozone to surface water has limited effect to remove dissolved organic matter. When ozone is used as oxidant to remove Mn(II) in the water, the existing co-ion should be evaluated to determine optimum concentration.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Characteristic Reactions in Anaerobic Nitrogen Removal from Piggery Waste (돈사폐수의 혐기성 질소제거공정에서 일어나는 특이반응)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.300-307
    • /
    • 2006
  • Anaerobic ammonium oxidation(ANAMMOX) is a novel process fur treatment of piggery waste with strong nitrogen. In this study, we investigated acid fermentation of organic matter, denitrificatiot reduction of sulfur compounds and P crystalization by hydroxyapatite during the treatment of wastewater with high strength of ammonium and organic matters by ANAMMOX process. Also, functions of hydroxylamine and hydrazine as intermedeates of ANAMMOX process were tested. This study reveals that various complex-reactions with anaerobic ammonium oxidation of piggery waste are happened and hydroxylamine and hydrazine play an important role in ANAMMOX reaction.

The Estimation of the Coagulant on Method of Lime Input in the Water Treatment Plant at High Turbidity (고탁도시 소석회 투입방법에 따른 정수장 응집제의 효율 평가)

  • Bang, Mi Ran;Lim, Bong Su;Bae, Byung Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.107-117
    • /
    • 1998
  • In order to removal turbidity at high turbidity, this study was carried to evaluate the coagulants(Alum, PACl, PACS) that was suited the characteristics of raw water in water treatment plants and to determinate the optimum method of lime feed. When the optimum coagulant was selected the organic matter removal was also investigated as $UV_{254}$. PACl, lime first feed had the highest turbidity removal efficiency rate as above 99.1% and then $UV_{254}$ removal rate was obtained over than 88.0%. If you had the necessary of the lime feed, among the method of lime feed time interval feed largely was improved than simultaneous feed. Also, lime feed dose had about 1/5 of coagulants dose in case of Alum and PACl, but always PACS should be considerated lime dose.

  • PDF