• 제목/요약/키워드: Wastewater monitoring

검색결과 215건 처리시간 0.034초

FAULT DETECTION, MONITORING AND DIAGNOSIS OF SEQUENCING BATCH REACTOR FOR INTEGRATED WASTEWATER TREATMENT MANAGEMENT SYSTEM

  • Yoo, Chang-Kyoo;Vanrolleghem, Peter A.;Lee, In-Beum
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.63-76
    • /
    • 2006
  • Multivariate analysis and batch monitoring on a pilot-scale sequencing batch reactor (SBR) are described for integrated wastewater treatment management system, where a batchwise multiway independent component analysis method (MICA) are used to extract meaningful hidden information from non-Gaussian wastewater treatment data. Three-way batch data of SBR are unfolded batch-wisely, and then a non-Gaussian multivariate monitoring method is used to capture the non-Gaussian characteristics of normal batches in biological wastewater treatment plant. It is successfully applied to an 80L SBR for biological wastewater treatment, which is characterized by a variety of error sources with non-Gaussian characteristics. The batchwise multivariate monitoring results of a pilot-scale SBR for integrated wastewater treatment management system showed more powerful monitoring performance on a WWTP application than the conventional method since it can extract non-Gaussian source signals which are independent and cross-correlation of variables.

Nonlinear PLS Monitoring Applied to An Wastewater Treatment Process

  • Bang, Yoon-Ho;Yoo, Chang-Kyoo;Park, Sang-Wook;Lee, In-Beum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.102.1-102
    • /
    • 2001
  • In this work, extensions to partial least squares (PLS) for wastewater treatment (WWT) process monitoring are discussed. Conventional data gathered by monitoring WWT systems are usually time varying, high dimensional, correlated and nonlinear, PLS has been shown to be an efficient approach in modeling and monitoring high dimensional and correlated data. To represent dynamic and nonlinear features of the data several kinds of dynamic nonlinear PLS (DNLPLS) models have been proposed. However, the complexity and ambiguity of the models make them unsuitable for WWT monitoring, Recently, dynamic fuzzy PLS (DFPLS) was proposed ...

  • PDF

소규모 현장 오수처리시설의 유지관리를 위한 Monitoring System 개발 (Development of the Monitoring System for maintaining On-site Wastewater Treatment Plants)

  • 조영현;권순국
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.417-420
    • /
    • 2001
  • The monitoring system for maintaining on-site wastewater treatment plants(Biofilter) was developed. Proposed system applied PLC(Programmable Logic Controller) technique. In process of development, the research against the monitoring parameters which will be able to represent condition and operation of the plants was accomplished. These parameters are ORP(Oxidation-Reduction Potential), Water Level, Pump and Power on/off. Also, to measure, collect, transfer and display these parameters, DMU(Data Measurement Unit), MCU(Main Controller Unit) and Display Board were produced.

  • PDF

C-HMI 기반의 원격지 중수도 설비 실시간 제어와 모니터링 구현 (Implementation of C-HMI based Real-time Control and Monitoring for Remote Wastewater Reclamation and Reusing System)

  • 이운선;박만곤
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.717-722
    • /
    • 2013
  • The wastewater reclamation and reusing system has been rising as an alternative of water resource exhaustion that the whole world is experiencing. In order to be able to bring about improvement of the existing wastewater reclamation and reusing system, this research has developed of Conversion-Human Machine Interaction (C-HMI) based real-time control and monitoring system such as a sensor module and gate module, web monitoring system. This system was communication almost-error-free in various environment and situation. As a result, we have achieved our goal that has to doing work correctly as a sensor and gateway module that communication error is less than 0.2% throughout the embodied system and add that it can be easily controled and configured as an interface equipment to a complex sensor of water quality. According to this, the construction of a database capable of analyzing and assessing collection, storage and various elements of reliable water quality and flow rate data can be possible.

Determination of 11 Phenolic Endocrine Disruptors using Gas Chromatography/Mass Spectrometry-Selected Ion Monitoring in Five Selected Wastewater Influents

  • Kim, Hyub
    • Environmental Engineering Research
    • /
    • 제13권4호
    • /
    • pp.216-223
    • /
    • 2008
  • An efficient method for the simultaneous determination of eleven phenolic endocrine-disrupting chemicals (EDCs) present in wastewater influent samples was described. The 11 phenolic EDCs including alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) following two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. The wastewater influent samples containing the 11 EDCs were adjusted to pH 2 with $H_2SO_4$ and then cleaned up with n-hexane. Next, they were subjected to solid-phase extraction (SPE) with XAD-4 resin and subsequently converted to isoBOC or TBDMS derivatives for sensitivity analysis with gas chromatography/mass spectrometry-selected ion monitoring (GC/MSSIM). Following isoBOC derivatization and TBDMS derivatization, the recoveries were 86.6-105.2% and 97.6-142.7%, the limits of quantitation (LOQ) for the 11 phenolic EDCs for SIM was 0.001-0.050 ng/mL and 0.003-0.050 ng/mL, and the SIM responses were linear with the correlation coefficient varying by 0.9717-0.9995 and 0.9842-0.9980, respectively. When these methods were applied to five selected wastewater influent samples, for isoBOC derivatization and TBDMS derivatization the ranges of concentration detected were 0.2-99.6 ng/mL and 0.4-147.4 ng/mL, respectively.

간접하수재이용에 따른 논에서의 수질 및 토양환경 영향 분석 (Effects of Indirect Wastewater Reuse on Water Quality and Soil Environment in Paddy Fields)

  • 정한석;박지훈;성충현;장태일;강문성;박승우
    • 한국농공학회논문집
    • /
    • 제55권3호
    • /
    • pp.91-104
    • /
    • 2013
  • The objectives of this study were to monitor and assess the environmental impacts of indirect wastewater reuse on water quality and soil in paddy fields. Yongin monitoring site (YI) irrigated from agricultural reservoir and Osan monitoring site (OS) irrigated with treated wastewater diluted with stream water were selected as control and treatment, respectively. Monitoring results for irrigation water quality showed a significant statistical difference in salinity, exchangeable cation and nutrients. Pond water quality showed a similar tendency with irrigation water except for the decreased difference in nutrients due to the fertilization impact. Soil chemical properties mainly influenced by fertilization activity such as T-N, T-P, and $P_2O_5$ were changed similarly in soil profiles of both monitoring sites, while the properties, EC, Ca, Mg, and Na, mainly effected by irrigation water quality showed a considerable change with time and soil depth in treatment plots. Heavy metal contents in paddy soil of both control and treatment did not exceed the soil contamination warning standards. This study could contribute to suggest the irrigation water quality standards and proper agricultural practices including fertilization for indirect wastewater reuse, although long-term monitoring is needed to get more scientific results.

생활하수의 농업용수재이용을 위한 생활하수 오염지구 수질 모니터링 (Water quality monitoring at irrigation districts polluted with wastewater for the wastewater reuse for agriculture)

  • 김상민;박승우;강문성
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.401-404
    • /
    • 2002
  • Two irrigation districts, Maekok and Byungjum 1 which are irrigated with polluted stream flow, and one control district Kichun, that is supplied from a reservoir complying with the water quality standard are selected for water quality monitoring to identify the effects of polluted irrigation on crop yields, environments, and health hazards for farmers. The water quality at Maekok and Byungjum 1 districts are worse than the control district, and continuous water quality monitoring are needed for the wastewater reuse for agriculture.

  • PDF

공공하수처리시설에서 수질오염물질 유입 및 배출 특성 고찰 - 산업폐수 및 매립지 침출수 연계처리 시설을 중심으로 - (A study on characteristics of influent and effluent pollutants in public sewage treatment works combined with industrial wastewater and landfill leachate)

  • 정동환;조양석;안경희;김은석;김창수;정현미
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.673-682
    • /
    • 2016
  • In this study, we investigated influent and effluent water pollutants in 53 Public Sewage Treatment Works (PSTWs) where industrial wastewater or landfill leachate is combined four times for two years from 2014 to 2015. Also, we analyzed the characteristics of heavy metals and volatile organic carbons at influent and effluent of these PSTWs caused by sewage treatment combined with industrial wastewater or landfill leachate. As a result, six heavy metals such as barium, copper, iron, manganese, nickel and zinc, and four volatile organic carbons (VOCs) including phenols, di(2-)ethylhexyl phthalate (DEHP), formaldehyde and toluene were observed above detection limits in most of PSTWs. Also, it was revealed that six heavy metals such as hexavalent chromium, mercury, cadmium, chromium, nickel and selenium, and four VOCs including 1,1-dichloroethylene, vinyl chloride, naphthalene, and epichlorohydrin were observed more frequently according to precipitation. As a result of reviewing the monitoring data on "Water Quality Monitoring Networks" in lower watersheds of PSTWs, both heavy metals and VOCs were below detection limits, indicating that the effluent water had little influence on the watershed. Nevertheless for the better management of influent and effluent pollutants in PSTWs, it is necessary to establish the advanced management plans for water pollutants in PSTWs, which include a list of priority substances management, monitoring plans, and guidelines for industrial wastewater and landfill leachate combined in PSTWs.

실제 상수관망에 대한 모니터링 지점선정방법의 적용 (Application of the Determination Method of Monitoring Location in Real Water Distribution System)

  • 박용균;정성균;권혁재
    • 상하수도학회지
    • /
    • 제29권6호
    • /
    • pp.617-623
    • /
    • 2015
  • In this study, determination methods of monitoring location in water distribution system were suggested and applied to real test bed. Small block of Gwangtan water distribution system is consisted of 582 pipes, 564 junctions, 1 reservoir, and 1 pump station. Small block of Ho Chi Minh water distribution system is consisted of 162 pipes, 148 junctions, and 1 reservoir. Two small block water distribution systems were analyzed by pressure contribution analysis method to determine the optimum monitoring locations. The pressure change was estimated at each junctions by the additional demand at a junction. From the results, the optimum monitoring location can be determined by rank of pressure contribution index at each junctions due to demand change at a junction.

하폐수의 재사용 및 방류를 위한 폭기조 내 표준산소전달 효율 모니터링 시스템에 관한 연구 (Study on the Standard Oxygen Transfer Efficiency Monitoring System in the Aeration Tank for Reuse and Discharge of Wastewater)

  • 김홍석;김용범;고경한;김상우;심환보
    • 자원리싸이클링
    • /
    • 제28권6호
    • /
    • pp.73-78
    • /
    • 2019
  • 본 연구에서는 활성 슬러지 하수처리장에서 배출되는 off-gas에 대한 포집 및 측정 모니터링을 통해 폭기조의 산소전달효율을 측정하고 청수와 비교하여 시스템의 신뢰성을 검증하는 연구를 수행하였다. 먼저, 청수를 기반으로 용존산소, 산소전달계수 및 표준산소전달효율을 측정하였으며 각각 8.60 mg/L, 9.49/hr, 23.96%의 값이 얻어졌다. 한편, 하수처리장 현장에서 진행한 off-gas 시험 결과 표준산소전달효율이 22.81%로 계산되어 청수와의 차이가 거의 없는 것으로 나타났다. 이는 현장에 설치된 산기관의 성능 및 폭기조의 상황을 모니터링 시스템을 이용해 실시간으로 확인함으로써 신뢰성있는 데이터를 확보할 수 있음을 의미한다.