• Title/Summary/Keyword: Wastewater Treatment Plants

Search Result 486, Processing Time 0.031 seconds

Construction of Long-term Load Duration Curve Using MOVE.2 Extension Method and Assessment of Impaired Waterbody by Flow Conditions (MOVE.2 확장기법 적용을 통한 장기 부하지속곡선 구축 및 유황조건별 수체손상평가)

  • Kim, Gyeonghoon;Kwon, Heongak;Im, Taehyo;Lee, Gyudong;Shin, Dongseok;Na, Seungmin
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.1
    • /
    • pp.51-62
    • /
    • 2017
  • The purpose of this study is to evaluate on the applicability of Load Duration Curve (LDC) method using Maintenance of Variance Extension types 2 method and sampling data for efficient total maximum daily loads at the Nakbon-A unit watershed in Korea. The LDC method allows for characterizing water quality data such as BOD, TOC, T-N and T-P in this study at different flow regimes(or quarters). BOD usually exceeded the standard value (exceedance probability 50%) at low flow zone. On the other hand, TOC, T-N, T-P usually exceeded the standard value at dry and low flow zone. Seasonally all water quality variables usually exceeded the standard value at Q1(Jan-Mar) and Q2(Apr-Jun) zones. Improvement of effluent control from wastewater treatment plants are effective to improve BOD and T-P.

Simple Material Budget Modeling for the Paldang Reservoir in the Spring Season (팔당호의 춘계 단순물질수지 모델링)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.696-714
    • /
    • 2017
  • Simple material budget models were developed to predict the spring season (March ~ May) water quality for a river-type reservoir Paldang, in the Republic of Korea. These models are available at mixed water bodies whose light intensity is negligible at the bottom. The calculated data from the models fit quite well with field data collected for 30 years, from 1988 to 2017. The apparent settling velocity of total phosphorus was estimated to be $110m\;d^{-1}$. The critical hydraulic load that determines the usability of phosphorus for algal production appeared to be about $2.0m\;d^{-1}$. When a hydraulic load was larger than the critical value, the concentrations of chlorophyll ${\alpha}$ ($Chl.{\alpha}$), chemical oxygen demand (COD), and 5-day biochemical oxygen demand BOD in the reservoir water became insensitive to internal algal reactions. The model analysis showed that the allochthonous COD continued to increase while the allochthonous BOD slightly decreased after 1999. The decrease of allochthonous BOD is due to the expansion of sewage and wastewater treatment plants in the watershed. The increase of allochthonous COD seems to result from the increase in anthropogenic non-point sources as well as the increase in the discharge of natural organic matters due to climate change. Organic matter of algal origin continued to increase until the mid-2000s, but recently it has decreased as the phosphorus concentration has decreased. The COD and BOD of algal origin increased from 35 % and 27 % during 1988 ~ 1994 to 43 % and 40 % during 2000 ~ 2010, respectively, and then decreased to 25 % and 28 % during 2011 ~ 2017.

Microbial Community in the TPH-Contaminated Aquifer for Hot Air Sparging using Terminal-Restriction Fragment Length Polymorphism (유류오염대수층 고온공기분사공정시 제한효소다형성 미생물 군집)

  • Lee, Junho;Park, Kapsong
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.19-29
    • /
    • 2008
  • Hot air sparging is a groundwater remediation technique, in which organic contaminants volatilized into hot air from the saturated to vadose zone. In the laboratory diesel (10,000 mg TPH/kg) was spiked in contaminated saturated aquifer soil. The hot air ($34.9{\pm}2.7^{\circ}C$) was injected in intermittent (Q=1,500 mL/min, 10 minute injection and 10 minute idle) modes. We performed microcosm tests using the groundwater samples to assess TPH reductive remediation activity. For Terminal-Restriction Fragment Length Polymorphism (T-RFLP) analysis of eubacterial communities in sludge of wastewater treatment plants and soil of experiment site, the 16S rDNA was amplified by Polymerase Chain Reaction (PCR) from the sludge and the soil. The obtained 16S rDNA fragments were digested with Msp I and separated by electrophoresis gel. We found various sequence types for hot air sparging experiment with sludge soil samples that were closely related to Bacillus (149 bp, Firmicutes), Methlobacterium (149 bp, Euryarchaeotes), Pseudomonas (492 bp, ${\gamma}$-Proteobacteria), etc., in the clone library. In this study we find that TPH-water was reduced to 78.9% of the initial value in this experiment aquifer. The results of the present study suggests that T-RFLP method may be applied as a useful tool for the monitoring in the TPH contaminated soil fate of microorganisms in natural microbial community.

Effect of Dissolved Effluent Organic Matter on Adsorption and Estrogenic Activity of Bisphenol A (용존성 방류수 유기물질이 비스페놀 A의 흡착 및 에스트로겐 활성에 미치는 영향)

  • Yoo, Jisu;Na, Joorim;Jung, Jinho
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.2
    • /
    • pp.128-135
    • /
    • 2019
  • This study evaluates the effect of dissolved effluent organic matter (SE-dEfOM) from sewage wastewater treatment plants on the adsorption and estrogenic activity of bisphenol A (BPA). Specific ultraviolet absorbance and fluorescence index analyses indicated that SE-dEfOM was mainly microbially derived non-humic substances differed from Suwannee River natural organic matter (SR-NOM) as reference. Both Langmuir and Freundlich models successfully explained the adsorption of BPA onto both SE-dEfOM and SR-NOM. Additionally, the SE-dEfOM showed higher binding capacities and affinities for BPA than those of SR-NOM, resulting in better reduction of the estrogenic activity of BPA. These findings suggest that the binding and toxicity of BPA are largely dependent on the source of organic matters.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

Guidelines and Optimum Treatment for Agriculture Reuse of Reclaimed Water (농업적 용수재이용 수질기준을 고려한 적정 하수재처리에 관한 연구)

  • Jung, Kwang-Wook;Jeon, Ji-Hong;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.36 no.3 s.104
    • /
    • pp.356-368
    • /
    • 2003
  • Water quality of effluent from wastewater treatment plants (WWTPS) was reviewed to examine the feasibility of agricultural reuse using USEPA and WHO guidelines. It might meet the guidelines for BOD and SS, however, the most critical microbiological concentration was too high and further treatment is required. The pilot study of three treatments were performed to reduce microbiological concentrations. The UV irradiation was proved to be very effective in disinfection of secondary level effluent, and about 30 mW ${\cdot}$ s/$cm^2$ of dose was suggested to meet the even most stringent USEPA guidelines. Slow sand filter demonstrated effective removal of bacteria, and effluent concentration of total coliform (TC), fecal coliform (FC), and E. coli. dropped from about 10,000/100 mL to 300, 200, and 150 MPN/100 mL, respectively, showing over 95% removal. These level of bacterial concentration sufficiently meet the WHO guidelines ($10^3\;{\sim}\;10^5$ FC/100 mL), and could meet the more stringent USEPA guidelines (200 FC/100 mL) if properly applied. Slow sand filter also provided about 50% removal of SS, turbidity, and BOD in addition to bacterial removal. The removal efficiency of pond system was relatively poor, but still showed over 85% removal and effluent concentration of TC, FC, and E. coli was all below 10,000/100 mL. The pond system alone could meet the WHO guidelines, but hardly meet the USEPA guidelines and further treatment might be necessary. Overall, three methods evaluated in the study treat the effluent to meet the WHO microbiological guidelines for agricultural reuse. The UV disinfection and slow sand filter might also could the USEPA guidelines, while the pond system can hardly meet the USEPA guidelines if applied alone. The WHO and USEPA guidelines were made based on data from upland field agricultural system and may not be directly applicable to the paddy field agricultural system. Therefore, national standards for agricultural reuse of reclaimed water should be made considering domestic agricultural systems as well as international guidelines. Also, further investigation is recommended to develop optimum and feasible treatment measures for agricultural reuse of effluent from WWTPs.

Treatment of Artificial Sewage Using a Zeolite Column (제올라이트 칼럼에 의한 인공생활하수처리)

  • Seo, Jeoung-Yoon
    • Korean Journal of Environmental Agriculture
    • /
    • v.21 no.3
    • /
    • pp.178-188
    • /
    • 2002
  • Constructed wetlands typically cost less to build and operate, and require less energy than standard mechanical treatment technology but they have similar performance to centralized wastewater treatment plants. Therefore, they were constructed especially many in rural areas, where are small villages but not industries. Plantless column tests were performed to investigate the possibility on using zeolite as a filter medium of constructed wetland for the wastewater treatment. Removal efficiency was $COD_{Cr}$ 94.63% T-P 41.41% and $NH_4^+-N$ 99.75% at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm filled with a zeolite mixture. This zeolite mixture consisted of 1 : 1 by volume of zeolites in the diameter range of 0.5 to 1 mm and 1 to 3 mm. Accordingly, hydraulic load 314 $L/m^2{\cdot}d$ was considered as optimal. Three zeolite mixtures were used to determine the optimal mixing ratio by volume of a zeolite (A) in the diameter range of 0.5 to 1 mm to a zeolite (B) in the diameter range of 1 to 3 mm 1 : 3, 1 : 1 and only B in A to B by volume were tested at hydraulic load 314 $L/m^2{\cdot}d$ and filtering height 100 cm $COD_{Cr}$ removal efficiency was more than 89% at mixing ratios of 1 : 3 and 1 : 1 in A to B. That of T-P ranged 56.42 to 58.72% and, that of T-N and $NH_4^+-N$ was 87% and 99% regardless of mixing ratios of two zeolites. Removal efficiency was lower at the column filled with only B. Removal efficiency was better at Inter medium filled with mixing ratio 1 : 1 in A to B than with the other mixing ratios. Thus, it was found that the mixture of mixing ratio 1 : 1 in A to B was appropriate far Inter medium of constructed wetland Removal efficiency was higher in down-flow than in up-flow, and all contaminants were removed most in 20 cm filter height near feeding area.

Preliminary Studies on the Necropsy-Based Health Assessment Index (HAI) Using a Ecological Indicator Species (생태 지표종을 이용한 해부학적 건강성 평가지수(HAI) 적용을 위한 예비실험)

  • Kim, Ja-Hyun;Bae, Dae-Yeul;Lee, Jae-Yon;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.62-72
    • /
    • 2006
  • Biological health in aquatic environments has been assessed by several approaches using various bio-taxa. Especially, fish has been identified as one of the best ecological indicators for an integrative health assessments in aquatic environments. In this preliminary study, the necropsy-based approach using the Health Assessment Index (Adams et al., 1993; HAI, Blazer, 2000), was employed for the assessments of aquatic environments influenced by effluent water from wastewater disposal plants (WDP) near a urban stream (i.e., Cap-Stream). For the impact analysis from the effluents, we developed 10 metric necropsy-based model including $M_l\;skin,\;M_2\;fin,\;M_3\;thymus,\;M_4\;spleen,\;M_5\;hindgut,\;M_6\;kidney,\;M_7\;liver.\;M_8\;eyes,\;M_9\;gill,\;and\;M_{10}$ pseudobranch. We set up duplicate controls (natural upstream water plus 5 fishes in each control tank) and duplicate treatments (effluent water from the WDP plus 5 fishes in each treatment tank) in the laboratory. Preliminary results showed that HAI values in the controls were zero, indicating an excellent condition by the criteria of HAI, while the HAI values in the treatments ranged between 40 and 150, indicating a poor condition. Also, various health conditions, based on the index of biological integrity (IBI), species richness, tolerance guilds, and trophic guilds supported the HAI approach. The HAI approach, not applied in Korea, not may be used as an surrogate fer ecological health assessment in lotic ecosystems.

Analysis and Prediction of Sewage Components of Urban Wastewater Treatment Plant Using Neural Network (대도시 하수종말처리장 유입 하수의 성상 평가와 인공신경망을 이용한 구성성분 농도 예측)

  • Jeong, Hyeong-Seok;Lee, Sang-Hyung;Shin, Hang-Sik;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.308-315
    • /
    • 2006
  • Since sewage characteristics are the most important factors that can affect the biological reactions in wastewater treatment plants, a detailed understanding on the characteristics and on-line measurement techniques of the influent sewage would play an important role in determining the appropriate control strategies. In this study, samples were taken at two hour intervals during 51 days from $1^{st}$ October to $21^{st}$ November 2005 from the influent gate of sewage treatment plant. Then the characteristics of sewage were investigated. It was found that the daily values of flow rate and concentrations of sewage components showed a defined profile. The highest and lowest peak values were observed during $11:00{\sim}13:00$ hours and $05:00{\sim}07:00$ hours, respectively. Also, it was shown that the concentrations of sewage components were strongly correlated with the absorbance measured at 300 nm of UV. Therefore, the objective of the paper is to develop on-line estimation technique of the concentration of each component in the sewage using accumulated profiles of sewage, absorbance, and flow rate which can be measured in real time. As a first step, regression analysis was performed using the absorbance and component concentration data. Then a neural network trained with the input of influent flow rate, absorbance, and inflow duration was used. Both methods showed remarkable accuracy in predicting the resulting concentrations of the individual components of the sewage. In case of using the neural network, the predicted value md of the measurement were 19.3 and 14.4 for TSS, 26.7 and 25.1 for TCOD, 5.4 and 4.1 for TN, and for TP, 0.45 to 0.39, respectively.

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.