• Title/Summary/Keyword: Waste solution

Search Result 1,033, Processing Time 0.028 seconds

The Removal of Heavy Metals in Aqueous Solution by Hydroxyapatite (Apatite를 이용한 중금속 제거)

  • 강전택;정기호
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.325-330
    • /
    • 2000
  • The hydroxyapatite (HAp) for the present study was prepared by precipitation method in semiconductor fabrication and the crystallized at ambient to 95$0^{\circ}C$ for 30min in electric furnace. The ion-exchange characteristics of HAp for various heavy metal ions such as $Cd^{2+}, Cu^{2+}, Mn^{2+}, Zn^{2+}, Fe^{2+}, Pb^{2+}, Al^{3+}, and Cr^{6+}$ in aqueous solution has been investigated. The removal ratio of various metal ions for HAp were investigated with regard to reaction time, concentration of standard solution, amount of HAp and pH of solution. The order of the ions exchanged amount was as follws: $Pb^{2+}, Fe^{3+}>Cu^{2+}>Zn^{2+}>Al^{3+}>Cd^{2+}>Mn^{2+}>Cr^{6+}. The Pb^{2+}$ ion was readily removed by the Hap, even in the strongly acidic region. The maximum amount of the ion-exchange equilibrium for $Pb^{2+}$ ion was about 45 mg/gram of HAp. The HAp would seem to be possible agent for the removal of heavy metal ions in waste water by recycling of waste sludge in semiconductor fabrication.

  • PDF

Refining of Manganese from Anode Slime of Electrolytic Zinc and Waste Dry Cell (전해아연의 Anode Slime과 건전지의 폐기물로부터 금속망간의 회수)

  • Yoon, Byoung-Ha;Kim, Dai-Ryong
    • Journal of the Korean institute of surface engineering
    • /
    • v.19 no.1
    • /
    • pp.13-19
    • /
    • 1986
  • Manganese in the Anode slime and the paste-positive material of waste-dry cell was recovered by leaching with the hydrochloric acid solution. The impurities (Zn, Fe, Pb), co-leached with manganese were removed from the leached solution prior to electrolysis by hydrometallurgical techniques such as the neutralization with ammonium hydroxide and cementation on manganese powder. The electrodeposition of manganese from the purified chloride solution with sodium selenate was performed. Cathode current efficiency was found to be affected significantly by the concentration of sodium selenate and ammonium chloride salt, bath temperate, current density and PH. The current efficiency of about 88.7% was obtained by electrolysis manganese chloride solution with sodium selenate (0.1/g) at 10$^{\circ}C$.

  • PDF

Adsorption Characteristics of Hydrogen Sulfide on Iron Hydroxide-based Adsorbent (수산화철계 흡착제의 황화수소 흡착 특성)

  • Ryu, Seung Hyeong;Seo, Youngjoo;Park, Joonwoo;Kim, Shin Dong;Park, Seong Soon
    • Journal of Korea Society of Waste Management
    • /
    • v.34 no.5
    • /
    • pp.468-473
    • /
    • 2017
  • This study was carried out to examine the characteristics of hydrogen sulfide adsorption using an iron hydroxide-based adsorbent. The prepared adsorbent was discussed with regard to its adsorption capacity and analyzed via surface analysis methods to illustrate the physical characteristics of hydrogen sulfide adsorption. As the drying temperature increased, the adsorption capacity of the adsorbent decreased from 29.15wt% to 22.73wt%. The adsorption capacity was decreased as the space velocity increased and showed an adsorption capacity of about 3.65 at $3,157.6h^{-1}$. The effect of sulfur dioxide was to decrease the adsorption capacity from 29.15wt% to 27.94wt%. The adsorbent exhibited the amorphous type in its physical appearance based on XRD and EDS analysis.

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Pickling of oxidized 304 Stainless Steel using Waste Acids from Etching Process of Silicon Wafer (실리콘 웨이퍼 에칭공정으로부터 발생(發生)된 폐산(廢酸)을 이용(利用)한 스테인리스 스틸의 산세거동(酸洗擧動) 연구(硏究))

  • Kim, Min-Seuk;Ahn, Jong-Gwan;Kim, Hong-In;Kim, Ju-Yup;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.17 no.2
    • /
    • pp.36-45
    • /
    • 2008
  • Pickling of oxidized 304 stainless steel has been investigated using rotating disk electrode in waste acid solutions generated from the etching process of silicon wafer in order to recycle them. The waste acid solution contained acetic, nitric, hydrofluoric acids, and silicon of $19.6g/L^{-1}$. Electrochemical behavior during the pickling was distinctively different between the original and silicon-removed acid solutions. Open circuit potential was continuously changed in the original solution, while it was discontinuously changed and fluctuated in the silicon-removed solution. Fast and abrupt removal of surface oxide layer with severe pitting was observed in the silicon-removed solution. It was found that solution temperature had the most influential effect on glossiness. Surface glossiness after pickling was decreased with solution temperature. At the same condition, the glossiness was higher in the original solution than in the silicon-removed solution.

Leaching of Copper and Other Metal Impurities from a Si-Sludge Using Waste Copper Nitrate Solution (실리콘 슬러지로부터 폐질산구리용액을 이용한 구리 및 금속불순물의 침출)

  • Jun, Minji;Srivastava, Rajiv Ranjan;Lee, Jae-chun;Jeong, Jinki
    • Resources Recycling
    • /
    • v.25 no.3
    • /
    • pp.11-19
    • /
    • 2016
  • A fundamental study to recycle a Si-Sludge and waste copper nitrate solution acid solution generated by domestic electronic industries was carried out. The waste copper nitrate solution was used as the lixiviant to leach the metals like Cu, Ca, Fe, etc. from the sludge leaving Si in the residues. The effect of reaction temperature, time and pup density on the metals leaching from the sludge was investigated. To enhance the extractability of Fe, the effect of HCl, $HNO_3$ and $H_2O_2$ introduced additionally during the leaching was also examined. Considering the leaching efficiency of Fe along with Cu, the leaching conditions comprising of 200 ~ 225 g/L pulp density and $90^{\circ}C$ temperature for 30 min were optimized. Under this condition, 98.27 ~ 99.17% Cu could be dissolved in the leach liquor with the obtained purity of Si in the residues as 98.69 ~ 98.86 %. The study revealed that the leaching of Cu contained in the Si-Sludge with the waste copper nitrate solution is a plausible approach by which the obtained leach liquor can further be treated suitably to recover Cu as the high pure value-added products.

Determination of Refreshing Time of Natural Zeolite Used for Livestock Waste Water Clearing Based on Electrical Conductivity (축산폐수(畜産廢水) 처리시(處理時) 전기전도도(電氣傳導度)를 기준(基準)한 천연(天然) Zeolite의 교환시기(交換時期) 결정(決定))

  • Choi, Jyung;Seo, Young-Jin;Lee, Dong-Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.29 no.2
    • /
    • pp.130-136
    • /
    • 1996
  • This study was carried out easily to determine the refreshing time of natural Zeolite used for the clearing of Livestock waste water and to investigate the relationship between EC of solution and adsorption amount on Zeolite. During the adsorption reaction, EC of supernatant solution decreased till the equilibrium was reached and kept a constant level after it. EC was greatly decreased with the concentration of solution and the magnitude of adsorbent. Decrease in EC of suspension was found to be lesser in addition of Na-Zeolite than Ca-Zeolite. EC change of Livestock waste water was shown to be similar tendency to that of the simulated waste water. On the cumulative adsorption isotherm, the EC of suspension increased until the EC value of the initial solution as the increase in treatment times. Therefore, it is apparent that the exchange point of natural zeolite should be in the vicinity of the EC value of initial waste water.

  • PDF

A Study on the Extraction of Collagen and Separation of Chrome Ion from Leather Waste (피혁 폐기물로부터 collagen 추출과 크롬이온 분리에 관한 연구)

  • Lim, Bong-Ju;Lim, Nam-Uoong;Lim, Han-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.6 no.1
    • /
    • pp.43-52
    • /
    • 1998
  • The objective of this study is to investigate the optimum conditions of extracting collagen without chrome ion from the leather waste. The effect of temperature, pH, and the concentration of alkaline solution on the collagen extraction has been studied. The result indicated that the incipient denatured temperature of collagen measured by viscosity was $25^{\circ}C$ and the complete denatured temperature was $31.5^{\circ}C$. The optimum solubilization condition for temperature was between $15^{\circ}C$ and $20^{\circ}C$, pH was 1.5, the concentration of alkaline solution was 3% of sodium hydroxide. The almost complete chrome ion separation was possible around the pH of 1.5. The separation efficiency of chrome ion from tannery waste was more than 99.5%. Extraction efficiency of crude protein from leather waste was about 89.5%. The hydroxyproline and collagen content in the extracted crude protein were 8.53% and 63.62%, respectively.

  • PDF

The Modified Eulerian-Lagrangian Formulation for Cauchy Boundary Condition Under Dispersion Dominated Flow Regimes: A Novel Numerical Approach and its Implication on Radioactive Nuclide Migration or Solute Transport in the Subsurface Environment

  • Sruthi, K.V.;Suk, Heejun;Lakshmanan, Elango;Chae, Byung-Gon;Kim, Hyun-su
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.2
    • /
    • pp.10-21
    • /
    • 2015
  • The present study introduces a novel numerical approach for solving dispersion dominated problems with Cauchy boundary condition in an Eulerian-Lagrangian scheme. The study reveals the incapability of traditional Neuman approach to address the dispersion dominated problems with Cauchy boundary condition, even though it can produce reliable solution in the advection dominated regime. Also, the proposed numerical approach is applied to a real field problem of radioactive contaminant migration from radioactive waste repository which is a major current waste management issue. The performance of the proposed numerical approach is evaluated by comparing the results with numerical solutions of traditional FDM (Finite Difference Method), Neuman approach, and the analytical solution. The results show that the proposed numerical approach yields better and reliable solution for dispersion dominated regime, specifically for Peclet Numbers of less than 0.1. The proposed numerical approach is validated by applying to a real field problem of radioactive contaminant migration from radioactive waste repository of varying Peclet Number from 0.003 to 34.5. The numerical results of Neuman approach overestimates the concentration value with an order of 100 than the proposed approach during the assessment of radioactive contaminant transport from nuclear waste repository. The overestimation of concentration value could be due to the assumption that dispersion is negligible. Also our application problem confirms the existence of real field situation with advection dominated condition and dispersion dominated condition simultaneously as well as the significance or advantage of the proposed approach in the real field problem.

Physical and mechanical properties of cement mortar with LLDPE powder and PET fiber wastes

  • Benimam, Samir;Bentchikou, Mohamed;Debieb, Farid;Kenai, Said;Guendouz, Mohamed
    • Advances in concrete construction
    • /
    • v.12 no.6
    • /
    • pp.461-467
    • /
    • 2021
  • Polyethylene-terephthalate (PET) from bottle waste and linear low-density polyethylene (LLDPE) from barrels and tanks waste are widely available and need to be recycled. Recycling them in concrete and mortar is an alternative solution for their disposal. In this study various quantities of sand (5%, 10%, 15% and 20%) were substituted by powder from LLDPE waste. In addition, PET waste fibers (corrugated, straight) were added to the mortar with different percentages (0.5%, 1%, 1.5% and 2%) of cement mass. This paper evaluate the mechanical and physical properties of the composites in fresh (workability, air content and density) and hardened state (compressive and flexural strength, water absorption and total shrinkage). From the experimental results, it can be concluded that the strengthening in tensile of the mortar with plastic waste corrugated fibers is improved. Other important results are that the water absorption and the density rate are less than that of the ordinary mortar.