A Study on the Thermodynamic Performance of Plastic Bottle Ice Storage System (플라스틱병을 이용한 빙축시스템의 열역학적 성능에 관한 연구)

  • Lee, S.K.;Kim, H.Y.;Lee, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.484-496
    • /
    • 1996
  • This paper presents an anlaysis on the thermodynamic performance of ice storage system. The primary interest in this work is the exergetic efficiency of the system. The ice storage system considered here is the capsule type system with the waste plastic bottle being used as a capsule. To examine the characteristics of irreversibility production and exergetic efficiency in detail the ice storage system to be analyzed has been separated from the refrigerator in this analysis. The analysis is based on the lumped model with 3 uniform temperatures. The results indicate that 3 dimensionless parameters can describe the exergetic efficiency of the system, from which the characteristics of irreversibilities and the ranges of these parameters to ensure the reasonable performance of the system can be found. Experiments also have been performed to demonstrate the feasibility of such a system. This analysis only shows the performance of ice storage side, with the refrigeration side excluded. However, the results can be interpreted as a total performance if the refrigerator coupled with the ice storage system operatres reversibly.

  • PDF

Performance Evaluation of a Defrosting System Using the Condensation Heat of a Refrigerator in Cold Storage (저온창고에서 냉동기 응축폐열을 이용한 제상시스템 성능평가)

  • Park, Chunwan;Lee, Donggyu;Im, Kwanbin;Kang, Chaedong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.2
    • /
    • pp.72-78
    • /
    • 2014
  • In a cold chain, the refrigerator is also employed for defrosting, by using an electric heater, which consumes 15% of the power for the system operation. In this study, the condensation heat of the refrigerant was suggested as the heat source of defrosting heat, instead of that from an electric defrost heater. The heat for defrosting was stored to a phase change material (PCM, NMP : $52^{\circ}C$) in thermal storage, and was periodically supplied to the evaporator by a circulation loop of brine. As a result, a defrost time by the PCM was obtained that was less than or equal to that by the electric heater. Moreover, power consumption during defrosting was saved by up to 99% of that of the electric heater.

A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle (吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구)

  • 박종구;양옥룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-86
    • /
    • 1992
  • This paper discusses the thermodynamic study on the suction cooling-steam injected gas turbine cycle. The aim of this study is to improve the thermal efficiency and the specific output by steam injection produced by the waste heat from the waste heat recovery boiler and by cooling compressor inlet air by an ammonia absorption-type suction cooling system. The operating region of this newly devised cycle depends upon the pinch point limit and the outlet temperature of refrigerator. The higher steam injection ratio and the lower the evaporating temperature of refrigerant allow the higher thermal efficiency and the specific output. The optimum pressure ratios and the steam injection ratios for the maximum thermal efficiency and the specific output can be found. It is evident that this cycle considered as one of the most effective methods which can obtain the higher thermal efficiency and the specific output comparing with the conventional simple cycle and steam injected gas turbine cycle.

A Study on the Improvement Strategy of Reuse and Recycling of Home Appliances Waste (폐가전제품의 재이용 및 재활용 활성화 방안에 관한 연구)

  • Park, Chan-Hyuk;Chung, Jae-Chun;Lee, Jae-Woong;Kim, Young-Jun;Choi, Suk-soon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.2
    • /
    • pp.74-85
    • /
    • 2003
  • The purpose of this study is to investigate present situation of recovery and treatment of waste home appliances, and to supply basic data for active reuse and recycling of waste home appliances. Among waste home appliances, refrigerator comprise 30.7%, television 37.8%, washing machine 22.9% and air conditioner 0.3%. Local government collected 46.2% of waste home appliances, producer and agent collected 49.7%, recycling center 4.1%. Seventeen percentage of waste home appliances are reused, 65% are recycled, and 18% are landfilled or incinerated. To improve the recycling activity of waste of home appliances, it is important to establish private reuse and recycling organization. It is also necessary to improve waste deposit and refund system for efficient recycling by decent financial support. Extension of a term of usage is another method to minimize waste home appliances. Finally, intensive education for consumer is necessary for waste minimization. Some portion of recycling and treatment cost can be allocated to the local government and large private business can shred and recycle waste home appliances.

  • PDF

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.

High Energy Resolution Alpha Spectrometer Using a Cryogenic Detector (저온검출기를 이용한 에너지 고 분해능 알파분광 구현)

  • Kim, M.S.;Lee, S.H.;Yoon, W.S.;Jang, Y.S.;Lee, S.J.;Kim, Y.H.;Lee, M.K.
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.132-137
    • /
    • 2013
  • Cryogenic particle detectors have recently been adopted in radiation detection and measurement because of their high energy resolution. Many of these detectors have demonstrated energy resolutions better than the theoretical limit of semiconductor detectors. We report the development of alpha spectrometer using a micro-fabricated magnetic calorimeter coupled to a large-area particle absorber. A piece of gold foil of $2{\times}2{\times}0.05mm^3$ was glued to the paramagnetic temperature sensor made of sputtered Au:Er film to serve as an absorber for incident alpha particles. We performed experiments with 241Am source at cryogen free adiabatic demagnetization refrigerator (CF-ADR). A high energy resolution of 6.8 keV in FWHM was obtained for 5.5 MeV alpha particles.

Impact of Renewable Energy on Extension of Vaccine Cold-chain: a case study in Nepal (신재생 에너지의 백신 콜드체인 확장 효과: 네팔 사례 연구)

  • Kim, Min-Soo;Mun, Jeong-Wook;Yu, Jongha;Kim, Min-Sik;Bhandari, Binayak;Bak, Jeongeun;Bhattachan, Anuj;Mogasale, Vittal;Chu, Won-Shik;Lee, Caroline Sunyong;Song, Chulki;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.94-102
    • /
    • 2020
  • Renewable energy (RE) is essential to comprise sustainable societies, especially, in rural villages of developing countries. Furthermore, application of off-grid RE systems to health care can improve the quality of life. In this research, a RE-based vaccination supply management system was constructed to enlarge the cold-chain in developing countries for the safe storage and delivery of vaccines. The system was comprised of the construction of RE plants and development of vaccine carriers. RE plants were constructed and connected to health posts in local villages. The cooling mechanism of vaccine carriers was improved and monitoring devices were installed. The effect of the system on vaccine cold-chain was evaluated from the field test and topographical analysis in the southern village of Nepal. RE plants were normally operated for the vaccine refrigerator in the health post. The modified vaccine carriers had a longer operation time and better temperature control via monitoring and RE-based recharging functionality. The topographical analysis estimated that the system can cover larger region. The system prototype showed great potential regarding the possibility of a sustainable and enlarged cold-chain. Thus, RE-based vaccine supply management is expected to facilitate vaccine availability while minimizing waste in the supply chain.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.