• Title/Summary/Keyword: Waste gas

Search Result 1,141, Processing Time 0.021 seconds

The Bio Gasification technology of organic waste using vertical multistage anaerobic digester (다단 수직형 혐기성 소화조를 이용한 유기성 폐기물 바이오가스화 기술)

  • Lee, Jong Hak;Eum, Young-Kyoung;Kim, Youngnoh
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.15-20
    • /
    • 2012
  • Processing of organic waste is converted to anaerobic digestion for environmental friendly and sustainable energy recovery and reduction of sludge. In this study, ECOPAD (ECOdays' Plug-flow Anaerobic Digster)design for a high solids content and high organic matter content were used to investigate an applicability and efficiency of food waste treatment and poultry wastewater treatment. Case-by-case analysis of treatment efficiency of ECOPAD using food waste of city "P" and city "S". Volatile Solids basis organic removal efficiency of city "P" and city "S" was 84% and 88% respectively. And, the content of methane (P City: 70%, S City: 71%) was measured similarly. In the case of poultry waste bio-gas production was measured to $1.6Nm^3/kg$-VSrem, and methane content was measured to 69%.

Performance of the Nanjido Composting Facility (난지도 퇴비화시범시설에서의 퇴비화과정 검토)

  • Namkoong, Wan;Kim, Joung-Dae;Park, Joon-Seok
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.5 no.2
    • /
    • pp.7-16
    • /
    • 1997
  • The food waste composting facility of 10 ton/d capacity at Nanjido has been operated successfully since July, 1996. This study was performed to investigate the characteristics of food waste quality, and variation of physicochemical characteristics of feed materials during composting. Food waste with 79% moisture content was used as a substrate. Wood chip was used as a bulking agent. Monitoring results based on VS, TOC, C/N ratio and gas composition indicated that the facility was operated normally under aerobic conditions. Conductivity values during food waste composting were increased. A highly positive correlation (r=1.00) existed between VS and TOC.

  • PDF

Employee Exposures to Waste Anesthetic Gases in Hospital Operating Rooms (종합병원 수술실 종사자의 마취가스 노출에 관한 연구)

  • Cha, Jung Young;Paek, Do Myung;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.193-201
    • /
    • 2006
  • This study was performed to investigate employee exposures to waste anesthetic gases, such as enflurane and sevoflurane in operating rooms of general surgical, children's and dental clinics of a large hospital located in Seoul and to analyze factors affecting the concentrations of waste anesthetic gases. The results of the study are summarized below. 1. Based on results of personal and area samples for airborne enflurane, all of the employees investigated in this study were exposed to airborne enflurane concentrations below the ACGIH-threshold limit value (TLV) of 75 ppm. 2. However, based on results of personal samples for sevoflurane, employees of two (2) out of eleven (11) operating rooms were exposed to sevoflurane concentrations in excess of the NIOSH recommended exposure limit (REL) of 2 ppm. A similar trend was found in the area samples. 3. To investigate the source of sevoflurane emissions, airborne sevoflurane concentrations were measured on an anesthesia machine, a drug cabinet and a desk. It was indicated that the geometric means were 0.93 ppm, 0.83 ppm and 0.72 ppm, respectively. 4. Factors affecting waste anesthetic gas concentrations were the age of anesthesia machine, the volume of operating room and the extent of ventilation (p<0.05). 5. It is recommended that the use of anesthesia equipments be properly controlled, the operating room be well ventilated, and the airborne concentrations of anesthetic gases be continuously monitored.

Characteristics of Microbial Community and Bio-hydrogen Production from Food Waste (음식물쓰레기의 생물학적 수소생산 및 미생물의 군집특성)

  • Choi, Moon-Su;Lee, Tae-Jin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.86-96
    • /
    • 2012
  • Hydrogen gas production of anaerobic fermentative process from food waste as a substrate was 3.47 mg $H_2/g$ COD. The hydrogen production was little less than the synthetic wastewater with sucrose as a substrate (7.56 mg $H_2/g$ COD). The B/A ratios of the synthetic wastewater and food waste were 3.73 or 8.01 respectively. Butyric acid was more produced when hydrogen production was higher. Microbial community in the samples was analyzed as Escherichia sp., Klebsiella sp., Clostridium sp., Bacterium sp., and Enterobacter sp. Clostridium sp. was detected both samples but Klebsiella sp. was more active with fermentation process of the food waste. Taxonomic description shows that 60% of the microorganism was ${\gamma}-proteobacteria$ and Firmicute and Bacteria was 20% respectively.

A Research on Predicting Biogas Production of Organic Waste in Island Region (도서지역 유기성 폐기물 성분분석을 통한 바이오가스 발생량 예측에 관한 연구)

  • Park, Jae Young;Moon, Jin Young;Hwang, Young Woo;Kwak, In Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.45-52
    • /
    • 2016
  • This study is to predict the biogas production and the content analysis of the organic wastes of three islands located in the City of I. Content analysis for a total of six sections, including pH, BOD, COD, three components (Moisture, Ash, Combustibles)was conducted on the specimens of organic wastes from the representative spots of three islands. From the analysis result of organic waste, it is confirmed that more than $1,750,000m^3$ of methane gas per year will be generated through the calculation of the total methane generation for the COD value. Therefore, if the incineration facility for the organic waste in island region is converted into a biogas production facilities which is non-incineration facility, it seems that the organic waste of efficient utilization is available.

Performance Design of Boiler for Waste Heat Recovery of Engine Coolant by Rankine Steam Cycle (엔진 냉각수 폐열 회수를 위한 랭킨 스팀 사이클용 보일러의 성능 설계)

  • Heo, Hyung-Seok;Bae, Suk-Jung;Hwang, Jae-Soon;Lee, Heon-Kyun;Lee, Dong-Hyuk;Park, Jeong-Sang;Lee, Hong-Yeol
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.58-66
    • /
    • 2011
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop(HT loop) is a system to recover the waste heat from the exhaust gas, a low temperature loop(LT loop) is for heat recovery from the engine coolant cold relatively. This paper has dealt with a layout of a LT loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the LT boiler, a core part of a LT loop, has been presented and analytically investigated. Considering the characteristics of the cycle, the basic concept of the LT boiler has been determined as a shell-and tube type counterflow heat exchanger, the performance characteristics for various design parameters were investigated.

Effects of Pipe Network Composition and Length on Power Plant Waste Heat Utilization System Performance for Large-scale Horticulture Facilities (발전소 온배수를 적용한 대규모 시설원예단지용 난방시스템의 열원이송 배관 재질 및 거리에 따른 성능평가)

  • Lee, Keum ho;Lee, Jae Ho;Lee, Kwang Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.14-21
    • /
    • 2015
  • Korean government plans to establish large-scale horticulture facility complexes using reclaimed land in order to improve the national competitiveness of agriculture at the government level. One of the most significant problems arising from the establishment of those large-scale horticulture facilities is that these facilities still largely depend on a fossil fuel and they require 24 h a day heating during the winter season in order to provide the necessary breeding conditions for greenhouse crops. These facilities show large energy consumption due to the use of coverings with large heat transmission coefficients such as vinyl and glass during heating in the winter season. This study investigated the applicability of waste heat from power plant for large-scale horticulture facilities by evaluating the waste heat water temperature, heat loss and energy saving performance as a function of distance between power plant and greenhouse. As a result, utilizing power plant waste heat can reduce the energy consumption by around 85% compared to the conventional gas boiler, regardless of the distance between power plant and greenhouse.

Combustion Characteristics of Waste Sewage Sludge using Oxy-fuel Circulating Fluidized Bed (슬러지 순산소 유동층 연소특성)

  • Jang, Ha-Na;Sung, Jin-Ho;Choi, Hang Seok;Seo, Yong-Chil
    • Korean Chemical Engineering Research
    • /
    • v.55 no.6
    • /
    • pp.846-853
    • /
    • 2017
  • Cold bed and $30kW_{th}$ pilot bed tests using circulating fluidized bed (CFB) were conducted to apply oxy-fuel technology for waste sludge combustion as a carbon capture and storage technology. In cold bed test, the minimum fluidization velocity ($u_{mf}$) and superficial velocity for fast fluidization was determined as 0.120 m/s and 2.5 m/s, respectively. In the pilot test, air and oxy-fuel combustion experiments for waste sludge were conducted using CFB unit. The flue-gas temperature in 21~25% oxy-fuel combustion was higher than that of air and up to 30% oxy-fuel combustion. In addition, the concentration of carbon dioxide was more than 80% with the oxygen injection range from 21% to 25% in oxy-fuel CFB waste sludge combustion.

The Characteristics of the Biochar with the Synthetic Food Waste and Wood Waste for Soil Contaminated with Heavy Metals (인공 음식물 혼합 폐기물 바이오차의 토양 중금속 흡착 가능성을 위한 특성 분석)

  • Baek, Ye-Seul;Lee, Jai-Young;Park, Seong-Kyu;Bae, Sunyoung
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • When processing the biomass by Hydrothermal carbonization (HTC), a slow pyrolysis process, it produces bio-gas, biooil, and biochar. Among these end products, biochar is known for isolating or storing carbon and being used as a soil amendment. In this study, the characteristics of biochar generated by HTC at $250^{\circ}C$ for 1 hour, 2 hours, 3 hours, and 20 hours with synthetic food wastes and wood wastes were analyzed for potential uses in soil contaminated with heavy metals. The yield of biochar (weight %) increased when the ratio of wood wastes increased and showed a decreasing tendency as reaction time increased. Elemental analysis of biochar based on various conditions showed a maximum of 70% carbon (C) content. The carbon content showed an increasing tendency with the increase of wood wastes. Iodine adsorption test was peformed to determine the optimum reaction condition, which was 15% wood waste for mixing ratio and 2 hours for reaction time. Using biochar generated at the optimum condition, its capability of adsorbing heavy metals (Cd, Cu, Pb, Zn, Ni) was evaluated. It was concluded that lead (Pb) was removed efficiently while zinc (Zn) and nickel (Ni) were hardly adsorbed by biochar.

A Study on the Refrigerant Characteristics of the Organic Rankine Cycle Power System Using the Waste Heat of the Main Propulsion Engine (선박 주 추진 엔진폐열을 이용하는 고온도차발전시스템의 냉매특성에 관한 연구)

  • Song, Young-uk;Jee, Jae-hoon;Park, Sang-kyun;Oh, Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.839-845
    • /
    • 2021
  • In this study, it shows the efficiency of each refrigerant through simulation method for ORC (Organic Rankine Cycle) power generation that converts waste heat discarded by ship exhaust into electricity for the purpose of reducing CO2 emission and increasing ship waste heat recovery. by Simulation was performed with waste heat from the exhaust gas which is relatively high temperature and cooling sea water which is relatively low temperature from ships. As a result of the sea water cooling ORC power generating system, efficiency of the working fluid with R717 is highest as a 2.86 % and the next working fluid is R152a, R134a, R143a and R125a.