• Title/Summary/Keyword: Waste gas

Search Result 1,141, Processing Time 0.027 seconds

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Luminous Environment and Light Pollution in Gas Stations with Non-cutoff Luminaires (Non-cutoff 조명기구가 설치된 주유소의 조명환경 및 빛공해 평가)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.7-16
    • /
    • 2008
  • Lighting for gas station should be carefully designed with safety and visually attraction. Recent studies have shown that non-cutoff luminaires should not be used for gas station. duo to light pollution and energy waste. This paper aims to evaluate the luminous environment in gas station with non-cutoff luminaires. The CS-100 and Radiant Imaging Prometric-1400 were used to measure the luminance of building surface, canopy, ceiling and ground surface. The result shows that the whole luminance of various combination elements in gas station increases by rising the total luminaires of the canopy. All of the gas stations with non-cutoff luminaries produce light pollution. Some guidelines for outdoor lighting in gas station is necessary.

A Review of Technology Development Trend for Hydrogen and Syngas Production with Coke Oven Gas (코크스 오븐 가스(COG)를 이용한 수소 및 합성가스 제조 기술 개발 동향 분석)

  • Choi, Jong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1247-1260
    • /
    • 2022
  • The steel industry accounts for about 5% of the total annual global energy consumption and more than 6% of the total anthropogenic carbon dioxide emissions. Therefore, there is a need to increase energy efficiency and reduce greenhouse gas emissions in these industries. The utilization of coke oven gas, a byproduct of the coke plant, is one of the main ways to achieve this goal. Coke oven gas used as a fuel in many steelmaking process is a hydrogen-rich gas with high energy potential, but it is commonly used as a heat source and is even released directly into the air after combustion reactions. In order to solve such resource waste and energy inefficiency, several alternatives have recently been proposed, such as separating and refining hydrogen directly from coke oven gas or converting it to syngas. Therefore, in this study, recent research trends on the separation and purification of hydrogen from coke oven gas and the production of syngas were introduced.

Analysis of Heavy Metal Concentration on Working Clothes for Waste Incinerating Workers (생활폐기물 소각장 작업복의 중금속 분석)

  • Park, Soon-Ja
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.1
    • /
    • pp.39-53
    • /
    • 2007
  • The purpose of this study was to determine the characteristics of an experimental protective clothing material with regard to comfort and isolation from the hazardous heavy metals produced in municipal waste incineration. An analysis was conducted on the total concentrations of heavy metals in some parts such as surface, middle layer, and interior for the treated fabric, and the untreated one, and working clothes. We conclude that the processed fabric with charcoal for working clothes showed the least exposure to heavy metals of the three. Working clothes worn by workers during waste incineration were much more contaminated than the untreated and treated materials. The material of working clothes could be chosen according to the function with regard to its original chemical characteristics, which are the proper results of the dyeing process. The processed fabric material has high degrees of moisture regain, thermal insulation, water vapor penetration, and antibacterial function; consequently, it is much more comfortable to wear. The fabric material proposed in this research contributed much more to blocking heavy metal concentrations (such as Cd, Pb, Cu, Cr, Zn, Mn) than did the fabric of working clothes at present. Consequently, we strongly suggest that the material of working clothes be upgraded by adopting the above-mentioned charcoal-processed fabric. Materials of working clothes must be improved to increase comfort and prevent harmful gas, flying dust, and heavy metals from permeating the fabrics.

  • PDF

Case study on the variation of landfill soil properties due to waste materials' characteristics (매립장 폐기물 특성에 따른 지반특성 변화 사례 연구)

  • Kim, Jin-Hwan;Cho, Jin-Woo;Baek, Yong;Lee, Yong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1213-1216
    • /
    • 2010
  • Developable areas nearby metropolitan areas, which has high the density of population are limited by highly industrialized. In recent, the redeveloping plans for the finished industrial and resident areas are pushing to resolve this problems. Getting to the exact properties for reclaimed wastes is very important to reuse of landfill. Also, a strategy for how to deal with follow-up measures have to based on the waste characteristics. A lot of environmental problems have been happened in finished waste landfill such as a nasty smell by seepage, pollution of surface and ground water, a poisonous gas and soil contamination. The environment pollution in waste landfill have been studied by many researchers. The goal of this study is estimate the effects for the ground properties with the environmental properties of waste in finished landfill. As the results, the chemical characteristics of seepage in landfill may effect directly or indirectly to capping layer. Therefore, sustainable researches are needed to develop a secure landfill over the long term.

  • PDF

Effects of Leachate during Vegetable Waste Composting using Rotary Drum Composter

  • Varma, V. Sudharsan;Kalamdhad, Ajay S.
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.67-73
    • /
    • 2014
  • In India, disposal of vegetable market waste along with municipal solid waste in landfills or dumpsites is creating much nuisance in terms of odor nuisance, leachate production, and greenhouse gas emission into the atmosphere. Therefore, vegetable waste with high biodegradable and nutrient content is composted in a 550-L batch scale rotary drum composter to study the degradation process and its compost properties for its potential reuse as high quality compost. A total 150 kg of working volume was fixed for composting studies with two different ratios, trial A (6:3:1) of C/N 24 and trial B (8:1:1) of C/N 30, respectively. A maximum of $63.5^{\circ}C$ and $61.2^{\circ}C$ was observed in trials A and B; an average of $55^{\circ}C$ for more than 5 days, which helped in the degradation of organic matter and reduction of total and fecal coliform. The temperature dropped suddenly after the thermophilic stage in trial B, and leachate was observed due to insufficient amount of bulking agent. Mesophilic bacteria dominated during the initial stages of composting, and reduced considerably during the thermophilic stage. During the thermophilic stage, the rise in spore-forming organisms, including spore-forming bacteria, fungi, actinomycetes and streptomycetes, increased and these were predominant until the end of the composting process. By examination, it was observed that moisture and leachate production had adverse effects on the compost parameters with higher loss of micronutrients and heavy metals.

A Study on Combustion Characteristics of Pulverized Fuel Made from Food Waste (음식물쓰레기로 부터 제조한 분체연료 연소특성)

  • Son, Hyun-Suk;Park, Yung-Sung;Kim, Sang-Guk
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.37-43
    • /
    • 2008
  • Three properties of food waste are water 80%, ash 3%, volatile matter 17%. When food waste goes through treatment process such as removal of foreign substances, removal of water as well as sodium, dryness, and pulverization, it transforms into 4,000 Kcal/kg purverized fuel if moisture content is below 13%. Fuel ratio (fixed carbon/volatile matter) of purverized fuel is low compared with bituminuous coal. Ignition temperature measured by thermogravimetry analyzer is about $460^{\circ}C$. Combustion test of purverized fuel have been performed using energy recovery facility which include storage tank of dewatered cake, dryer, hammer mill, combuster including burner, boiler, flue gas treatment equipment. When 160-180 kg/hr of fuel is steadily supplied to burner for 3 hours, combustor temperature reaches about $1000^{\circ}C$ and CO is 77-103 ppm at 1.55 excess air ratio and SOx and Cl are under 2 ppm and 1ppm, respectively. This experiment demonstrate that purverized fuel made from food waste could be an alternative clean energy at the age of high oil price.

  • PDF

Disposal of Highly Toxic Wastes by using High Temperature and High Pressure Combustor (난분해성 환경오염물질의 고온.고압연소)

  • Yoon, Jae-Kun;Hong, Ho-Yeun;Lee, Jeong-Woo;Kim, Jong-Pyo;Kang, Su-Sok
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.75-78
    • /
    • 2006
  • Disposal of highly toxic wastes like polychlorinated biphenyls (PCBs) is very difficult. These substances create a growing mountain of problematic waste that has to be disposed properly. Conventional technologies that are based on common burning(rotary kiln, ${\sim}1100^{\circ}C$) and plasma technology(${\sim}10000^{\circ}C$) do not satisfy important conditions. for example, complete combustion of the toxic waste and the price of waste disposal. The combustor like a rocket engine is operated at relatively high pressure(${\sim}15$ bar) and relatively high temperature(>$3000^{\circ}C$) that are ideal for the complete destruction of extremely toxic substances. In this study, test compound($_o-DCB$) was dissolved in kerosine with a concentration of 10%. Pure gas oxygen was used as an oxidant. Analysis showed that the destruction efficiency achieved for ${o}-DCB$ was 99.9999% or better. The results show that a combustor based on liquid propllant rocket technology is a validated tool for the disposal of highly toxic waste, and a good alternative technology when applied to the destruction of extremely toxic wastes.

  • PDF

A Study on Combustion Characteristics of Purverized Fuel Made from Food Waste (음식물쓰레기로부터 제조한 분체연료 연소특성)

  • Son, Hyun-Suk;Park, Yung-Sung;Yun, Jong-Deuk;Lee, Ho-Nam;Lee, Seung-Hoon;Kim, Sang-Guk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.149-152
    • /
    • 2008
  • Three properties of food waste are water 80%, ash 3%, volatile matter 17%. When food waste goes through treatment process such as removal of foreign substances, removal of water as well as sodium, dryness, and pulverization, it transforms into 4,000Kcal/kg purverized fuel if moisture content is below 13%. Fuel ratio(fixed carbon/volatile matter) of purverized fuel is low compared with bituminuous coal. Ignition temperature measured by thermogravimetry analyzer is about $460^{\circ}C$. Combustion test of purverized fuel have been performed using energy recovery facility which include storage tank of dewatered cake, dryer, hammer mill, combuster including burner, boiler, flue gas treatment equipment. When 160-180 kg/hr of fuel is steadily supplied to burner for 3 hours, combueter temperature reaches about $1000^{\circ}C$ and CO is 77-103ppm at 1.55 excess air ratio and SOx and Cl are under 2ppm and 1ppm, respectively. This experiment demonstrate that purverized fuel made from food waste could be an alternative clean energy for high oil price era

  • PDF

Menu quality Analysis in University Foodservice operated by Contracted Foodservice Management Company (위탁운영 대학교 급식소 메뉴의 품질 분석)

  • Yang, Il-Sun;Han, Kyung-Soo
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.3
    • /
    • pp.155-162
    • /
    • 2000
  • The purpose of this study was to analyse serving size, plate waste, and sensory evaluation on menu of university foodservice. This study was conducted in three restaurant of one university for 14 days, 1995. The serving size of food was measured by weighing machine. The plate waste of food was calculated by the aggregative selective plate waste measurement technique. Questionnaires of sensory evaluation were developed and hand-delivered at three restaurants. Rating criteria of sensory evaluation were appearance, taste, temperature, color, flavor, texture and overall quality. The plate waste of side dish were 35.5%, 42.5%, and 39.2% in A, B, and C restaurants. The plate waste of kimchi were 46.8%, 36.3%, and 55.9% in A, B, and C restaurants. So, university foodservice manager should concern quality of side dish and kimchi. The score of fried food in sensory evaluation was low. So, batch cooking was needed. The score of rice in sensory evaluation of C restaurants was very low. Therefore, steam ice cooker in C restaurants should be changed by gas automatic rice cooker.

  • PDF