• Title/Summary/Keyword: Waste gas

Search Result 1,141, Processing Time 0.026 seconds

Pyrolysis And Melting System

  • Uno, Susumu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.84-90
    • /
    • 2002
  • In 1995 we licensed pyrolysis gas melting technology of indirect heating type (using kiln) from Siemens AG, and built its demonstration facility in 1998 at Clean-Park-East of Fukuoka City to demonstrate the technology for municipal solid waste (MSW). In 1997 we were awarded an order from Kanemura Co., Ltd. to build a pyrolysis gas melting and power generation plant, specifically for treating residue from car shredder. The latter was launched in 1998, and is currently in commercial operation. The operation of these plants have proven the following facts. (1) The system is capable for performing a stable operation with a wide variety of waste. (2) Pyrolysis is achieved steadily regardless of the variation in the quality of waste. (3) The system can be operated under low excess air ratio (1.2∼1.3). (4) The concentration of dioxins at the furnace outlet is 0.062ng-TEQ/㎥$\_$N/, and 0.002ng-TEQ/㎥$\_$N/, at the stack. (the value is corrected to dryO$_2$ 12%) (5) The purity of recovered metals exceeds 90%.

  • PDF

Suggestions for the Estimation of the Methane Emission from a Landfill Site

  • Lee, Kyungho;Jeon, Eunjeong;Lee, Youngmin;Park, Junghyun
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.69-73
    • /
    • 2020
  • Sudokwon landfill("Sudokwon" means regions of Seoul, Kyunggi and Incheon metropolitan cities in Korea), the world's largest sanitary landfill, has been systematically managing statistics on the incoming and dumping wastes and satisfactorily controlling pollutants including leachate and LFG. According to our long time experience of LFG field monitoring, the emission of GHG from landfill estimated by the IPCC Guideline showed much difference with our results. C&D waste has high concentration of sulfate compared to other wastes. Increased C&D waste of dumping waste had changed the COD/sulfate ratio in the landfill, which caused the increase of H2S gas and the decrease of CH4 gas. But the IPCC estimation method does not consider the effects of sulfate. In addition to that, the oxidation factor of the cover soil is set to the default values of 0.1 but the measured values by the field monitoring, are showing much higher than that, especially in the closed landfill.

Pilot scale biofilter를 이용한 축산폐수의 악취제거

  • Park, Jeong-Yeop;Mun, Cheol-Hyeon;Jang, Seok-Jin;Hwang, Jae-Ung;Park, Seong-Hun
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.415-418
    • /
    • 2002
  • A performance of pilot scale biofilter was investigated for the treatment of odorous waste gas. The system treated 508.7 $m^3h^{-1}$ of waste air with amine and ammonia concentrations ranging up to 0.06 $N-gm^{-3}$ Over the four month study, its elimination capacity was demonstrated up to 6.37 $N-gm^{-3}h^{-1}$ and its removal efficiency was 100%. Differ to lab scale biofilter, It is difficult to maintain the proper temperature of reactor because of low external temperature. Experiments were performed indicating various problem such as sudden system shut down, unstable pump, water addition malfunction and corrosion of reactor. However, pilot scale biofilter was stable when treatment of odorous waste gas.

  • PDF

Evolution of Sudokwon Landfill: from Waste Containment to Energy Generation

  • Chung, Moon-Kyung;Kim, Yun-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.186-193
    • /
    • 2009
  • Since its opening in 1992, Sudokwon Landfill has become a landfill in which wastes generated from more than 22 million people are treated and disposed of. Its first phase landfill was closed in 2000 and the second phase landfill is in operation since then. The Korean environmental policies on refuse have drastically evolved for the last decade or so. From merely safe containment of wastes, the utilization of them as a source for energy generation and the minimization of waste volume to be filled in landfills are in the mainstream. Keeping in pace with the new trends, several challenging projects are in their way to blossom in Sudokwon Landfill. This paper briefs some important activities in the landfill. They are (1) geotechnical issues related to the construction and maintenance of the $1^{st}$ and $2^{nd}$ Landfills and (2) landfill gas and bioreactor which are recently emerging in the market.

  • PDF

Quality Property of the Artificial Stone Using the Waste Porcelain (폐자기를 사용한 인조석재의 품질평가)

  • Yoo, Yong-Jin;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.171-172
    • /
    • 2015
  • Recently, it is the global warming phenomenon because of the greenhouse gas exhaustion caused by and the environment problem is serious. And it is the situation where the problem of the exhaustion of resource because of the indiscriminate picking of the that is the raw material of the cement, limestone and natural aggregate are emphasized. In addition, thus the cement reduction amount of use and substitute material research is the urgent actual condition with the gas emission, which here it is generated in conducting compression molding in the building stone manufacturing process performance degradation phenomenon and fire resistance, and problem of the durability. Therefore, in this research, the waste porcelain is applied to the artificial stone and the durability property of the artificial stone according to it tries to be investigated.

  • PDF

Abrasion Resistance Property of the Magnesia Phosphate Ceramics(MPC) Artificial Stone Using the Waste Porcelain (폐자기를 사용한 마그네시아 인산염 세라믹(MPC) 인조석재의 내마모특성)

  • Yoo, Yong-Jin;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.51-52
    • /
    • 2014
  • Recently, it is the global warming phenomenon because of the greenhouse gas exhaustion caused by and the environment problem is serious. And it is the situation where the problem of the exhaustion of resource because of the indiscriminate picking of the that is the raw material of the cement, limestone and natural aggregate are emphasized. In addition, thus the cement reduction amount of use and substitute material research is the urgent actual condition with the gas emission, which here it is generated in conducting compression molding in the building stone manufacturing process performance degradation phenomenon and fire resistance, and problem of the durability. Therefore, in this research, because of being the magnesia phosphate ceramics, the waste porcelain is applied and the anti-wearing character of the artificial stone according to it tries to be investigated.

  • PDF

Separation of Tetrodotoxin, DHA and EPA from Pufferfish Liver Waste (복어간 폐기물로부터 Tetrodotoxin, DHA 및 EPA의 분리)

  • 차병윤;최진석;임정규;이동익;이원갑;이은열;김희숙;김동수
    • Journal of Life Science
    • /
    • v.10 no.2
    • /
    • pp.115-124
    • /
    • 2000
  • The present study was undertaken to separate the available components effectively, such as tetrodotoxin(TTX), docosahexaenoic acid(DHA, C22:6,ω-3) and eicosapentaenoic acid (EPA, C20:5,ω -3) from pufferfish liver waste, which are known to have high values as bioactive materials. By using ultrafiltration, it was possible to separate high contents of 68mg TTX from pufferfish liver waste. In contrast, by activated charcoal column, it was to obtain about 54mg TTX. The recovering ratios were 65.3% and 45.0% in the two different methods of ultrafiltration and activated charcoal column, respectively. From the results of HPLC and gas chromatography-mass spectrometry(GC-MS), the obtained toxins were identified to be TTX and its derivatives. In addition, it was also possible to obtain 72.3g DHA and 11.4g EPA from 1kg of pufferfish liver by high performance liquid chromatography (HPLC). These amounts of DHA and EPA were also 17.70% and 1.04% in the total lipid of pufferfish liver oil from analysis of gas chromatography(GC), respectively.

  • PDF

A Thermodynamic Study on Suction Cooling-Steam Injected Gas Turbine Cycle (吸氣冷却-蒸氣噴射 가스터빈 사이클에 관한 열역학적 연구)

  • 박종구;양옥룡
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.77-86
    • /
    • 1992
  • This paper discusses the thermodynamic study on the suction cooling-steam injected gas turbine cycle. The aim of this study is to improve the thermal efficiency and the specific output by steam injection produced by the waste heat from the waste heat recovery boiler and by cooling compressor inlet air by an ammonia absorption-type suction cooling system. The operating region of this newly devised cycle depends upon the pinch point limit and the outlet temperature of refrigerator. The higher steam injection ratio and the lower the evaporating temperature of refrigerant allow the higher thermal efficiency and the specific output. The optimum pressure ratios and the steam injection ratios for the maximum thermal efficiency and the specific output can be found. It is evident that this cycle considered as one of the most effective methods which can obtain the higher thermal efficiency and the specific output comparing with the conventional simple cycle and steam injected gas turbine cycle.

Process Development of Pyrolysis Liquefaction for Waste Plastics (폐플라스틱의 열분해 유화기술 개발)

  • Nho Nam-Sun;Shin Dae-Hyun;Park Sou-Won;Lee Kyong-Hwan;Kim Kwang-Ho;Jeon Sang-Goo;Cho Bong-Gyu
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.118-125
    • /
    • 2006
  • The target of this work was the process development of demonstration plant to produce the high quality alternative fuel oil by the pyrolysis of mixed plastic waste. In the first step of research, the bench-scale units of 70 t/y and the pilot plant of 360 t/y had been developed. Main research contents in this step were the process performance test of pilot plant of 360 ton/year and the development of demonstration plant of 3,000 t/y, which was constructed at Korea R & D Company in Kimjae City. The process performance of pilot plant of 360 t/y showed about 80% yield of liquid product, which was obtained by both light gas oil(LGO) and heavy gas oil(HGO), The boiling point range distribution of LO product that was mainly consisting of olefin components in PONA group appeared at between that of commercial gasoline and kerosene. On the other hand, HO product was mainly paraffin and olefin components and also appeared at upper temperature distribution range than commercial diesel. Gas product showed a high fraction of $C_3\;and\;C_4$ product like LPG composition, but also a high fraction of $CO_2$ and CO by probably a little leak of process.

  • PDF