• 제목/요약/키워드: Waste Incinerator

검색결과 225건 처리시간 0.026초

폐기물 소각시설의 이산화탄소 (CO2) 연속측정 실효성에 관한 연구 (A Study on the Effectiveness of Continuous CO2 Emission Monitoring in a Waste Incinerator)

  • 오승환;강임석;정동희
    • 한국기후변화학회지
    • /
    • 제9권3호
    • /
    • pp.273-281
    • /
    • 2018
  • The purpose of this study is to consider the effectiveness of continuous $CO_2$ emission monitoring in waste incinerator. To prevent global warming, many countries are trying to reduce $CO_2$, the main greenhouse gas. Currently, Korea is implementing an emission trading scheme to reduce $CO_2$, and waste incinerators are included in this scheme as major $CO_2$ sources. However, when using waste incinerators, $CO_2$ is discharged during incineration of various types of wastes, therefore it is very difficult to calculate the amount of emissions according to IPCC guidelines. In addition, the estimation of $CO_2$ emissions by calculation is known to lack of accuracy comparing with actual emissions. Currently, Korea is operating CleanSYS, which enables continuous measurement of gases emitted into the atmosphere. Therefore, it is possible to estimate the $CO_2$ emissions of waste incineration facilities. The IPCC, which published $CO_2$ emission calculation guidelines, recognizes that direct measurement of emission is a more advanced method in cases of various $CO_2$ emission sources such as a waste incineration facility. Also, Korean emission trading scheme guidelines allow estimation of $CO_2$ emissions by continuous measurement at waste incineration facilities. Therefore, this study considers the effectiveness of a direct measurement method by comparing the results of CleanSYS with the calculation method suggested by the IPCC guidelines.

도시 소각로 시설의 고형 쓰레기 연소 후 생성된 바닥재 시료에 대한 다이옥신과 퓨란류의 분석 (Analysis of Dioxins and Furans from Bottom Ash Produced in an Municipal Solid Waste Incinerator)

  • 장윤석;홍종기;김진영
    • 대한화학회지
    • /
    • 제39권7호
    • /
    • pp.513-523
    • /
    • 1995
  • 다이옥신은 환경에 미량으로 존재하며 직접, 간접적인 경로를 통해 인체로 들어와 심각한 문제를 일으키는, 화학적으로 안정하고 잔류성과 독성이 강한 오염물질이다. 쓰레기 처리를 위한 소각로 시설은 다이옥신에 대한 대기오염의 주원인으로 알려져 있는데 연소시 소각로내에서와 배기가스 제어과정 중 다이옥신이 발생되는 것으로 보고되고 있다. 본 연구에서는 쓰레기 소각로에서 연소 후 생성된 바닥재 시료를 채취하여 다이옥신과 퓨란류를 조사하였다. 시료의 전처리는 EPA방법을 개선하여 불필요한 과정을 생략하면서 높은 회수율을 유지하였고 최종 정량은 고분해능 기체 크로마토그래피/고분해능 질량분석기(HRGC/HRMS)를 이용하여 분석하였다. 바닥재 시료를 분석한 전체 다이옥신의 양은 8.05 ng/g, 퓨란은 4.75 ng/g정도이었으며 2,3,7,8-TCDD는 6.93 pg/g이 검출되었고 염소원자 가 6~7개 치환된 다이옥신과 퓨란이 가장 많이 검출되는 경향을 볼 수 있었다.

  • PDF

미연소 섬유분에 의한 도시 쓰레기 소각재 혼입 시멘트 복합재료의 성능감소 (Performance Degradation of Cement Composite Containing Municipal Solid Waste Incinerator Ash by Unburned Fabric)

  • 김형기
    • 자원리싸이클링
    • /
    • 제24권4호
    • /
    • pp.3-11
    • /
    • 2015
  • 도시 쓰레기 소각재 내 미연소 섬유분(Unburned fabric)이 시멘트 복합재료의 기초 물성에 미치는 부정적 영향에 대해 실험적으로 검증하였다. 먼저, 섬유분을 많이 포함하고 있는 0.6 mm 이하 소각재 미분의 물리적, 화학적 특성을 확인하였다. 그 후, 소각재 미분이 혼입된 모르타르형 시멘트 복합재료의 유동성과 강도를 측정하고, 이 결과를 소각재 미분의 물리적, 화학적 특성과 연계하여 분석하였다. 실험 결과, 시멘트 복합재료의 유동성은 미연소 섬유분에 의해 크게 감소한 반면, 복합재료의 강도는 섬유분 보다 소각재 자체에 의해 감소함을 알 수 있었다. 따라서, 시멘트 복합재료의 성능을 고려 할 때, 복합재료 내 소각재의 혼입률과 함께 소각재 미분에 대한 혼입률도 제한되어야 함을 확인하였다.

중형폐기물 소각시설의 수은, 납, 비소, 셀렌 배출특성 (Characteristics of Hg, Pb, As, Se Emitted from Medium Size Waste Incinerators)

  • 이한국
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.8-18
    • /
    • 2006
  • The aim of this study is to evaluate the emission characteristics of mercury, lead, arsenic, and selenium from medium size municipal solid waste incinerators(MSWIs) in Korea. The concentrations of mercury, lead, arsenic, and selenium emitted from medium size MSWI stack were $2.67\;{\mu}g/Sm^3,\;0.38\;mg/Sm^3,\;1.33\;{\mu}g/Sm^3,\;0.28\;{\mu}g/Sm^3$, respectively. The concentration levels of mercury, lead, arsenic in flue gas from medium size MSW incinerator stacks selected were nearly detected under the Korea criteria level. Removal efficiencies of mercury, lead, arsenic, and selenium in waste heat boiler(WHE) and cooling tower(CT) were $90.36\%,\;69.76\%,\;43.04\%,\;40.64\%$, respectively. In general, the removal efficiencies of mercury and lead in WHE were higher than those of arsenic and selenium in WHE. Emission gas temperature reduction from waste heat boiler(WHB) and cooling tower(CT) can control mercury and lead of medium size MSWIs. To evaluate the relationship between mercury, lead, arsenic, selenium of fly ash and those of flue gas, it was carried out to correlation analysis of each metal concentration in the fly ash and in the flue gas from medium size MSWIs. From the correlation analysis, the coefficients of mercury, lead, arsenic, and selenium were 0.61, -0.38, 0.87, 0.28, respectively. The results of correlation analysis revealed that it should be highly positive to the correlation coefficients of mercury and arsenic in the fly ash and those of the flue gas emitted from medium size MSWIs. As it were, the concentrations of mercury and arsenic of flue gas from medium size MSWIs are high unless mercury and arsenic in fly ash are properly controlled in dust collection step in medium size MSWIs. It was also concluded that mercury, lead, arsenic, and selenium from MSWIs stacks could be controlled by waste heat boiler(WHE) and dust collecting step in medium size MSWIs.

이성체 정보를 이용한 토양 중 다이옥신 오염원 해석 (Source Estimation of Dioxin in Soil Using a Congener Pattern)

  • 김종국;김경수;김재식;신선경;정영희;정일록
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.316-322
    • /
    • 2005
  • 폐기물 소각시설 주변토양 중 다이옥신 농도를 분석하여 소각시설로부터 거리와 방향에 따른 농도변화를 고찰하고, 시료에 대한 군집분석을 수행하여 발생원이 수용체에 미치는 영향에 대해 검토 하였다. 토양 중 다이옥신 총 농도 및 I-TEQ 농도는 각각 $31.065{\sim}7,257.499\;pg/g\;d.w.$$0.099{\sim}35.191\;pg\;I-TEQ/g\;d.w.$로 나타났다. 조사대상 소각시설 이외의 주변에 소형 소각시설들이 산재해 있어 토양 중 다이옥신 농도와 풍향 및 거리와의 상관성은 약한 것으로 나타났다. 반면 소각시설 배출가스의 영향을 파악하기 위하여 PCDFs와 PCDDs의 비율을 조사한 결과, 소각시설에서 멀어질수록 배출가스에서 높은 비율로 검출되는 PCDFs의 비율이 감소하는 경향을 보였다. 조사대상 소각시설이 주변 토양 중 다이옥신 농도에 미치는 영향권은 500 m 이내인 것으로 판단되었고 먼거리에서 고농도가 검출된 것은 주변에 존재하고 있는 소형 소각시설이나 농약(PCP) 등 다른 오염원에 의한 복합적인 영향을 동시에 받고 있는 것으로 사료되었다. 다이옥신 발생원과 수용체인 토양의 이성체 패턴을 이용한 군집분석 결과, 4개의 그룹으로 나눌 수 있었으며, 각 그룹의 이성체 패턴 비교를 통해 소각시설 배출가스와 농약 등의 발생원이 수용체에 미치는 영향정도에 대해 정성적인 추정이 가능하게 되어 군집 분석이 통계적 수법의 하나로 이용될 수 있을 것으로 사료되었다.

The Estimation of Emission Factor of N2O and CH4 by Measurement from Stacks in the Waste Incinerators and Cement Production Plants

  • Choi, Sang-Min;Im, Jong-Kwon;Hong, Ji-Hyoung;Lee, Sue-Been;Zoh, Kyung-Duk
    • 한국환경보건학회지
    • /
    • 제33권3호
    • /
    • pp.217-226
    • /
    • 2007
  • The purpose of this study is to estimate the emission factor of $non-CO_2$ global warming gases such as $N_2O$ and $CH_4$ by measuring concentrations from stacks of waste incinerators and cement production plants. Based on the established monitoring methods, $N_2O$ concentration measured from stacks in incinerator were between 0.62 and $40.60\;ppm_v$ (ave. $11.50\;ppm_v$). The concentration of $N_2O$ was dependent on the incinerator types. However, the concentrations of $CH_4$ gas were between 2.65 and $5.68\;ppm_v$ (ave. $4.22\;ppm_v$), and did not show the dependency on the incinerator types. In the cement production plant, the concentration ranges of $N_2O$ from the stack were from 6.90 to $10.80\;ppm_v$ (ave. $8.60\;ppm_v$), and $CH_4$ were between 1.80 and $2.20\;ppm_v$ (ave. $2.60\;ppm_v$). Using measured concentrations, the emission amounts of $N_2O$ and $CH_4$ from stacks per year were calculated. The results were is 4.2 ton $N_2O/yr$ in the incinerators, and 53.7 ton $N_2O/yr$ in the cement facilities. The big difference is from the flow rate of flue gas in the cement facilities compared to the incinerators. By the same reason, the $CH_4$ emission amounts in cement plant and incinerator was found to be 339 ton $CO_2/yr$ and 34.1 ton $CO_2/yr$, respectively. Finally, the emission factor of $N_2O$ in the incinerators were calculated using the measured concentration and the amount of incinerated wastes, and was $42.5\sim799.1\;g/ton$ in kiln and stoker type, $11.9\sim79.9\;g/ton$ in stoker type, 90.1 ton/g in rotary kiln type, 174.9 g/ton in fluidized bed type, and 63.8 g/ton in grate type, respectively. Also, the emission factors of $CH_4$ were found to 65.2-91.3 g/ton in kiln/stoker type, 73.9-122 g/ton in stoker type, 109.5 g/ton rotary kiln, and 26.1 g/ton in fluidized bed type. This result indicates that the emission factor in incinerators is strongly dependent on the incinerator types, and matched with result of IPCC (International Panel on Climate Change) guideline.

Waste Management and Treatment of Decommissioned Radioactive Combustible Waste

  • Min, B.Y.;Lee, Y.J.;Yun, G.S.;Lee, K.W.;Moon, J.K.
    • Journal of Nuclear Fuel Cycle and Waste Technology
    • /
    • 제1권1호
    • /
    • pp.75-82
    • /
    • 2013
  • A large quantity of radioactive waste was generated during the decommissioning of the KRR and UCF. The radioactive waste was packed into 200 liter drums and 4m3 containers and these were temporarily stored onsite until their final disposal in the national repository facility. Some of the releasable waste was freely released and utilized for non-nuclear industries. The combustible wastes were treated by the utilization of an incinerator with a capacity of on average 20 kg/hr.

연소로 열유동 해석 방식과 결과 분석에 대한 고찰;화격자식 소각로의 사례 (Discussion on the Practical Use of CFD for Furnaces;A Case of Grate Type Waste Incinerators)

  • 류창국;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제24회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.85-94
    • /
    • 2002
  • Computational flow dynamics(CFD) has been frequently applied to the waste incinerators to understand the flow performance for various design and operating parameters. Though it needs many simplifications and complicated flow models, the reasonability of its results is not fully evaluated. For example, the inlet condition is calculated from an arbitrarily assumed properties of combustion gas release from the waste bed, since the combustion in the bed is difficult to be predicted. In this study, the computational modeling and calculation procedures of CFD for the grate type waste incinerator were evaluated using comparative simulations. Though the assumption method on the generation of the combustion gas directly affected the temperature and gas species concentrations, the overall flow pattern was dominated by the secondary air jets. The gaseous reaction could be included by assuming the release of the products of incomplete combusion from the bed. However, the reaction effficiency cannot not be directly evaluated from the species concentration, since it is not possible to simulate the actual co-existence of fuel rich or oxygen rich puffs over the bed. In predicting the turbulence, the higher order model, such as Reynolds stress model, gave difference shape of local recirculation zones, but similar results was acquired from the standard $k-{\varepsilon}$ model. Introducing radiation model was required for accurate temperature prediction, but it also caused heat imbalance due to the fixed temperature of the inlet, i.e. the waste bed. Thus, the computational modeling procedures on incinerators and the analysis of the predicted results should be progressed carefully. Though not validated experimentally, current simulation method is capable of comparative evaluation on the flow-related parameters such as the furnace shape and secondary air injection using identical inlet conditions. Quantitative analysis using measures of the residence time and mixing is essential to compare the flow performance efficiently.

  • PDF

A Study on Removal of Harmful, Heavy Metals in Fly Ash from Municipal Incinerator

  • Nakahiro, Yoshitaka
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 The 6th International Symposium of East Asian Resources Recycling Technology
    • /
    • pp.489-493
    • /
    • 2001
  • Big cities in Japan have serious problems due to the shortage of new reclaimed land for municipal wastes. If harmful heavy metals such as cadmium, lead, copper and etc. are contained in the municipal waste combustion residues, they are not able to fill up according to the environmental law in Japan. In this study, the removal of heavy metals in the fly ash (EP ash) was dealt with chloridizing vaporization method. EP ash as a non-hazardous materials is utilized as covering materials, road bed, and building materials.

  • PDF