• 제목/요약/키워드: Waste Incinerator

검색결과 225건 처리시간 0.025초

쓰레기 소각로의 2차공기가 유동현상에 미치는 현상 연구 (Study for a Secondary Air Affecting Fluid Flow in a Solid Waste Incinerator)

  • 이금배
    • 대한기계학회논문집B
    • /
    • 제20권9호
    • /
    • pp.2924-2932
    • /
    • 1996
  • As the environmental pollution can be greatly reduced and the waste heat can be also recovered through a combustion of municipal solid waste, the incineration begins to be highlighted recently in our country. But it is very difficult to be operated with constant combustion conditions for a long time as the domestic waste is composed of various components, contains a large percentage of water, and has a low heating value. Therefore, the cold flow test and partial hot flow test were conducted in the incinerator by use of injection angles of a secondary air affecting fluid flow as the first action to maintain the optimum combustion conditions. A model to a scale of 1:10 was designed and manufactured through the similarity of model and prototype flows. Velocities and temperatures were measured through the experiment. From the results, fluid flows of secondary air obtained from partial hot flow test correspond almost well with those of main flow obtained from cold flow test. Consequently, injection angles of secondary air are proved to affect main flow decisively.

산업폐기물 소각시설에서 폐기물 유형에 따른 입자상물질의 배출특성 (Emission Characterization of Particulate Matters According to the Types of Wastes from Industrial Waste Incinerator)

  • 박정호;서정민;조정구;류재용;한성종
    • 한국환경과학회지
    • /
    • 제16권11호
    • /
    • pp.1225-1230
    • /
    • 2007
  • The emissions characteristics of particulate matters(PM) according to the types of wastes from industrial waste incinerator of 800 kg/hr treatment capacity were investigated. For this study, the incinerate waste are as follows; waste resin, waste wood, waste urethane, waste gunny, and waste paper. The particulate samples were collected to be emitted in stack and air pollution control(both cyclone and bag filter). In stack, the concentrations of PM were in the range of 2.61 to $26.51 mg/Sm^3$ and the major chemical species were C, Si, Cl, K, Na, Ca in all the wastes. In cyclone fly ash, the mean content of heavy metal were in the order of Fe > Zn > Pb > Cu > Mn > Cr > Ni > Cd > As > Hg and the heavy metal content of waste resin were Zn 34,197.5 mg/kg, Fe 27,587.6 mg/kg, Pb 6,055.8 mg/kg, respectively. In bag filter fly ash, the mean content of heavy metal were in the order of Zn > Pb > Fe > Cu > Mn > Cd > Cr > Ni > As > Hg and the heavy metal content of waste wood were Pb 36,405.2 mg/kg, Fe 15,762.9 mg/kg, Cu 9,989.5 mg/kg, Cd 2,230.1 mg/kg, respectively. Comparing the heavy metal content of both cyclone and bag filter, in cyclone, the Cr, Fe, Ni content were higher than in bag filter and the Cd, Cu, Hg content were lower than in bag filter.

도시고형폐기물 소각시설의 N2O 배출계수 개발 (The Development of N2O Emission Factor at Municipal Solid Waste Incinerator)

  • 고재철;최상현
    • 청정기술
    • /
    • 제25권1호
    • /
    • pp.40-45
    • /
    • 2019
  • 본 연구에서는 도시고형폐기물 소각시설을 대상으로 2018년 8월 27일부터 2018년 10월 22일 동안 총 3회에 걸쳐 도시고형폐기물의 소각에 의해 발생되는 $N_2O$ 농도를 24시간 동안 연속적으로 측정하여 발생량과 배출특성을 조사하였으며, 배출가스 중 $N_2O$ 농도측정은 비분산 적외선 분석기(NDIR)를 이용하였다. $N_2O$ 배출특성을 조사한 결과 도시고형폐기물 소각시설의 $N_2O$ 발생량 및 발생농도는 폐기물의 성상 보다는 소각시설의 소각로 온도와 산소농도 같은 운전조건에 따라 상이하게 발생하는 것으로 판단된다. 도시고형폐기물 소각시설의 $N_2O$ 일일평균 발생농도는 53.6 ~ 59.5 ppm이며, 전체 평균농도는 55.6 ppm으로 측정되었다. 또한 $N_2O$ 농도를 이용하여 계산된 $N_2O$ 발생량은 $90.41{\sim}108.44kg\;day^{-1}$이며, 평균 발생량은 $98.05kg\;day^{-1}$로 조사되었다. 이러한 결과를 바탕으로 도시고형폐기물 소각시설의 $N_2O$ 배출계수를 산출한 결과 $1,066.13g_{N_2O}\;ton_{waste^{-1}}$로 생활폐기물의 Tier 2 방법으로 산출된 $N_2O$ 배출계수에 비해 약 20배 정도 높은 결과를 얻었다. 따라서, 폐기물 종류와 소각량을 이용한 폐기물 소각시설의 $N_2O$ 발생량 산출방식은 정확성에 대한 보완이 필요할 것으로 판단된다.

중.소형 폐기물소각로 및 배연탈황공정용 홍합(Hard-Shelled Mussel) 패각페기물 Sorbent 적용에 관한 연구 (A Study on Sorbent Application of Hard-Shelled Mussel Waste Shell on the Medium/small Scale Waste Incinerator and Flue Gas Desulfurization Process)

  • 정종현
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.34-42
    • /
    • 2003
  • The objective of this study is to investigate the waste recycling possibility, practicability, economic efficiency and acid gas sorbent use of the hard-shelled mussel. This study is to investigate the hydration/calcination reaction and fixed bed reactor. The physical-chemical characteristics of the hard-shelled mussel were analyzed by ICP SEM-EDX, BET and pore volume. Thus, the results could be summarized as follows; Hard-shelled mussel can be used as iron-manufacture and chemical sorbents considering more than 53.7% of the mussel is lime content. The SO$_2$removal efficiency of the hard-shelled mussel after calcined hydration increased thirty times as a result of the higher pore size, specific surface area and pore volume. Also, the CaO content, pore volume, pore size distribution and specific surface area greatly influenced the SO$_2$ and NOx removal reactivity. The optimum particle diameter average of hard-shelled mussel was $\pm$100 mesh, which was applied to the sorbent on the medium/small scale waste incinerator and flue gas desulfurization processes.

EROD-microbioassay에 의한 학교 소각로 잔재 중 다이옥신 유사물질의 측정 (Determination of Dioxin-like Components in the School Waste Incinerator Residues by EROD-microbioassay)

  • 정규혁;오승민;윤완진
    • 한국환경보건학회지
    • /
    • 제26권3호
    • /
    • pp.11-17
    • /
    • 2000
  • There are among the most relevant toxic emissions from incinerators such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), dioxin-like polychlorinated biphenyls (PCBs). Induction of cytochrome P4501A1 catalyzed 7-ethoxyresorufin O-deethylase(EROD) activity in mammalian cell culture(EROD bioassay) is thought to be a selective and sensitive parameter used for the quantification of dioxin-like components. In this study, the toxic emissions from several school waste incinerators were evaluated by determination of CYPIA catalytic activity and cytotoxicity using cell culture microbioassay. The incinerator residue and soil samples were collected from the schools located in Kyunggi province from April to June 1999. The samples were extracted in a Soxhlet apparatus using toluene for 20 hours. In order to clean-up, concentrated crude extracts were applied to basic alumina column. The EROD activities of extracts in the H4IIE cells were from 1.91$\pm$0.32 ng-TEQ/g to 24.54$\pm$3.48 ng-TEQ/g of biochemical-TEQ value. In soil samples, CYP1A catalytic activity was 0.09~0.64 ng-TEQ/g. EROD bioassay, seems to be a useful short-term bioassay when information about the biological response of complex environmental samples is needed. Although further study is needed, these results indicate that the potent toxic emissions are produced from school waste semi-incinerators.

  • PDF

소나무 잎을 이용한 대기 중 다이옥신/퓨란 발생원 추정 (Source Tracking of PCDD/Fs in Ambient Air Using Pine Needles)

  • 천만영;김정수;고도현
    • 한국환경보건학회지
    • /
    • 제41권1호
    • /
    • pp.49-60
    • /
    • 2015
  • Objectives: Pine needles were used as a passive air sampler (PAS) of atmospheric persistent organic pollutants (POPs). This study was performed to investigate concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) deposited on pine needles near a waste incinerator and PCDD/Fs source contributions using principal component analysis (PCA). Methods: Two-year-old pine needles were sampled at 11 points with respect to distance and wind direction from the incinerator. PCDD/Fs deposited on pine needles were analyzed with HRGC/HRMS. The source contribution of PCA was calculated with SPSS. Results: The average concentration of PCDD/Fs deposited on pine needle was 0.79 (0.27-1.76) pg TEQ/g dry, PCDDs with 0.24 (0.01-0.95) pg TEQ/g dry and PCDFs with 0.56 (0.27-0.82) pg TEQ/g dry, respectively. The average concentration fraction of PCDDs was 29.7%, that of PCDFs was 70.3%, and PCDFs were more prevalent than PCDDs. The contributions of PCDD/Fs sources were estimated as incineration at 58.3% and automobiles at 28.4%. However, a relation and regulation between PCDD/Fs concentrations deposited on pine needles and distance from incinerator or wind direction was not shown. Conclusion: It was concluded that atmospheric PCDD/Fs concentrations near an industrial complex with a waste incinerator were affected by multiple sources. However, PCDD/Fs concentrations were lower than in other inland cities with the exception of background area.

가속탄산화를 통한 Ca-rich Waste Mineral의 정량적인 CO2 고용량 평가 (Quantitative Evaluation of CO2 Sequestration in Ca-rich Waste Mineral for Accelerated Carbonation)

  • 남성영;엄남일;안지환
    • 한국세라믹학회지
    • /
    • 제51권2호
    • /
    • pp.64-71
    • /
    • 2014
  • Accelerated carbonation is a technique that can be used as a CCS technology for $CO_2$ sequestration of approximately 5~20% in a stable solid through the precipitation of carbonate. An alkaline inorganic waste material such as ash, slag, and cement paste are generated from incinerators, accelerated carbonation offers the advantage of lower transport and processing costs at the same generation location of waste and $CO_2$. In this study, we evaluated an amount of $CO_2$ sequestration in various types of inorganic alkaline waste processed by means of accelerated carbonation. A quantitative evaluation of $CO_2$ real sequestration based on a TG/DTA analysis, the maximum 118.88 $g/kg_{-waste}$ of $CO_2$ in paper sludge fly ash, the maximum 134.46 $g/kg_{-waste}$ of $CO_2$ in municipal solid waste incinerator bottom ash, the maximum 9.72 $g/kg_{-waste}$ of $CO_2$ in industrial solid waste incinerator fly ash, and the maximum $18.19g/kg_{-waste}$ of $CO_2$ in waste cement paste.

유동층에서 기포의 유동특성에 관한 연구 (A Study on the Flow Characteristics of Bubbles in a Fluidized Bed)

  • 김용섭
    • 한국해양공학회지
    • /
    • 제10권3호
    • /
    • pp.117-124
    • /
    • 1996
  • A fluidized bed combustion chamber is widely used to incinerate waste material. The most important factor designing the incinerator is the flow characteristics in a fluidized bed, because combustion efficiency is influenced by the flow characteristics. This paper has invesitigated the flow characteristics of bubbles in fluidized bed by means of meassuring a pressure fluctuation in the fluidized bed. A pressure probe system has used to measure the pressure. The data concerned with bubble rising velocity, bubble size, distribution of bubbles and frequency of bubble generation or decay are obtained to find the flow characteristics of bubbles in the fluidized bed. The result obtained from this experimental study can be used to design the fuel feeding system of fluidized bed combustion type incinerator. And it is possible to predict the mixing of waste material and fluidizing material.

  • PDF

폐기물 소각시 중금속 성분의 거동에 관한 연구 (A Study on Behavior of Heavy Metals during Waste Incineration)

  • 박용이;허철구
    • 한국환경과학회지
    • /
    • 제5권6호
    • /
    • pp.785-799
    • /
    • 1996
  • The incineration tests of mixed industrial wastes using the stoker type incinerator are carried out to investigate the partitioning characteristics of heavy metals during incineration. The results obtained from this study are as follow. The partitioning characteristics of heavy metals throughout this incinerator are found that, at given condition of $700^{\circ}C$, the elements with the relatively high boiling point such as Cr, Cu and Pb are partitioned into a bottom ash, a fry ash captured tv cyclone, and a flue gas stream, 67~88%, 2~19% and 6~16% of initial amount entering the incinerator, respectively, but the Cd and Hg of 75~81% is vaporized into the flue gas. It appears that the partitioning characteristics according to the particle size of ash is different between the bottom ash and the fly ash. For bottom ash, the fraction of partitioning into 75${\mu}{\textrm}{m}$ oversized particles is reatively high. For fly ash, the characteristics of distributions with the particle size can not be clearly shown.

  • PDF

중간류식 폐기물 소각로 연소실의 최적형상 설계를 위한 유동해석 (Flow Analysis for the Geometry Optimization of Combustion Chamber of Central Flow Type Waste Incinerator)

  • 이진욱;김성배;윤용승;김현진;허일상
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.252-259
    • /
    • 2001
  • Computational study has been performed to observe the flow characteristics of combustion chamber for geometrical modification in municipal solid waste incinerator. A series of geometrical modification has been carried out as an attempt to reduce the size of recirculation zone, to obtain uniform flow field in the secondary combustion chamber and to improve the mixing of combustion gas. Two dimensional non-reacting turbulent flow has been studied as the first step to get such goals and the result of design optimization is presented. In addition, three dimensional non-reacting and reacting flow analyses were performed to verify the validity of two dimensional approach.