• Title/Summary/Keyword: Washing method

Search Result 796, Processing Time 0.024 seconds

Effects of HCl and EDTA on Soil Washing to Remediate Lead-contaminated Soil in a Firing Range (사격장 납 오염토양 복원을 위한 토양세척시 HCl과 EDTA의 영향 연구)

  • Kim, Hyo-Sik;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.1
    • /
    • pp.60-66
    • /
    • 2008
  • Laboratory soil washing experiments with HCl or EDTA were conducted to remediate lead-contaminated soil in a firing range. After lead bullets were removed by standard sieve #18 (1.0 mM), Pb concentrations were measured by EPA Method 3050B (9,443 mg/kg) and Korea Standard Test (4,803.5 mg/kg). The results of the batch test showed that the removal efficiency curve was logarithmic and approximately 90% of lead in soil was removed, when HCl was used. In case of EDTA, the removal efficiency increased proportionally to the concentration of EDTA, up to 98% lead removal with 0.1M EDTA. High mixing strength resulted in increase of removal efficiency and kinetics showed that the most lead was extracted in 10 min.

Natural Indigo Dyeing of Cotton Fabric - One-step reduction/dyeing process - (면직물에의 천연 인디고 염색 - 일단계 환원/염색 공정 -)

  • Shin, Youn-Sook;Cho, A-Rang;Yoo, Dong-Il
    • Textile Coloration and Finishing
    • /
    • v.22 no.2
    • /
    • pp.101-109
    • /
    • 2010
  • The objective of this study is to investigate the characteristics of natural indigo dyeing of cotton fabric. Reduction and dyeing were carried out by one-step process using an infrared dyeing machine at the liquor ratio of 1:100, and subsequently oxidation and washing in water were followed. Dye uptake was increased with the increase of indigo concentration. Over the full range of dyeing tests, the dyeing condition was optimized to $40^{\circ}C$ for 40min. For most of dye concentrations, the cotton fabrics showed mainly PB color. Maximum K/S value was shown at 4g/L of sodium hydrosulfite concentration and the color strength increased with the increase of dye concentration. Value(lightness) decreased with the increase of dye uptake irrespective of mercerization or reduction method, while the mercerized cotton showed two times higher dye uptake than the untreated cotton. Whereas hue of the untreated cotton showed large decrease of P character(5.6~3.5 PB) with the increase of dye uptake, that of the mercerized cotton increased P character(4.7~5.5 PB). Irrespective of mercerization, value and chroma decreased with the increased of dye uptake. In addition, the untreated showed lower chroma than the mercerized cotton. In the case of traditional reduction, hue of the untreated cotton was changed very little with the increase of dye uptake. For hydrosulfite reduction, P character decreased with the increase of dye uptake. The difference of hue value was small with the change of reduction method(hydrosulfite reduction or traditional fermentation). Color character was not influenced by the changed maximum absorption wavelength. Washing fastness showed 4~4/5 shade change rating without any staining. And dry rubbing fastness was good at low color strength. The bacterial reduction ratios of dyed cotton fabric were also increased.

Education on Nosocomial Infection Control within the Content of Courses in Fundamentals of Nursing (기본간호학 교과과정내 감염관리교육 현황분석)

  • Lim Nan-Young;Sohng Kyeong-Yae;Shon Young-Hee;Kim Jong-Im;Gu Mee-Ock;Kim Kyung-Hee;Paik Hoon-Jung;Byeon Young-Soon;Lee Yoon-Kyoung;Kim Hwa-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.1
    • /
    • pp.66-72
    • /
    • 2005
  • Purpose: The purpose of this study was to explore the content related to nosocomial infection control in the course on Fundamentals of Nursing. Method: Participants were 49 faculty who were teaching courses in Fundamentals of Nursing in universities and colleges in Korea. The questionnaire was composed of 55 items related to nosocomial infection control. Results: Eighteen items out of 55 items were taught in more than 80% of the universities and colleges. These included principles of infection control, principles and effect of hand washing, method of hand washing, hand scrubs, and donning sterile gown and gloves. Conclusion: The most effective interventions for infection control: including asepsis, hand washing, infection control for urinary catheterization, and infection control for IV sites were taught in most universities and colleges. However, the time assigned for teaching these items and the importance placed on practice were not considered sufficient.

  • PDF

Combination Dyeing of Silk Fabrics with Dansam and Sappan Wood (단삼과 소목을 이용한 견직물의 복합염색)

  • Nam, Jeongran;Lee, Jeongsook
    • Textile Coloration and Finishing
    • /
    • v.25 no.4
    • /
    • pp.314-326
    • /
    • 2013
  • The purpose of this research is to analyze the effects of Dansam and Sappan wood extract to perform combination dyeing on silk fabrics, with respect to color changes, fastness (washing, dry cleaning, perspiration, rubbing and light fastness), and functionality (antibacterial activity and deodorization). Combination dyeing was performed by first combining Dansam with Sappan wood, then Sappan wood with Dansam, in these orders. Given the changes in the combination ratio, pre-mordant treatment was performed. Looking at the surface colors of each dye, Dansam generally produces YR color series, while Sappan wood produces YR, R, and RP color series. The effects of changing the order in which combination dying was performed on the surface colors were as follows. First, combination dyeing (A) was performed by using Dansam before Sappan wood, to produce YR and R color series. Then combination dyeing (B) was performed by using Sappan wood before Dansam, to produce YR, R, and RP color series. By visual inspections, more similar color changes of the combination dyeing were noticed with the post-dyeing material rather than the pre-dyeing material. Therefore, it was presumably confirmed that surface color changes of combination dyeing were greatly influenced by the post-dyeing color. Individual dyeing tests for fastness showed that Dansam was comparatively superior to Sappan wood, which demonstrated lower fastness to washing, dry cleaning, perspiration, and light, relatively. The fastness of combination dyed samples was shown middle, but similar fastness to the post-dye material, The fastness of (B) method was higher than (A) method in the washing and light fastness. This confirms that color fastness from combination dyeing was considerably influenced by the post-dye material. It was found that all dyed samples had a very high bacterial reduction rate of 99.9% and high deodorization rate of 95%.

Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

  • Jang, Won-hee;Jung, Kyoung-mi;Yang, Hye-ri;Lee, Miri;Jung, Haeng-Sun;Lee, Su-Hyon;Park, Miyoung;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • v.23 no.4
    • /
    • pp.379-385
    • /
    • 2015
  • The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCE$^{TM}$ which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCE$^{TM}$ can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines.

A Study on Reliability Estimation for Fatigue Life of the Spider from a Drum Washing Machine (드럼 세탁기 Spider의 피로수명 신뢰성 평가에 대한 연구)

  • 이성민;조상봉;조성진;김영수;강동우;정연수;정보선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.46-49
    • /
    • 2004
  • The spider of a drum washing machine receives the repeated fatigue loadings during laundering. Although the spider is designed statically safely, it often happens fatigue failure. Therefore it requires the safe design for fatigue and needs the prediction of quantitative fatigue life. The S-N diagram for a spider material is developed by fatigue test and statistical analysis. The stresses are measured directly from strain gages on the spider. To predict the fatigue life of spider, the rainflow counting method and Miner's rule are used. The data for fatigue life are analyzed statistically. From these data, reliability estimation for fatigue life can be done and also, equivalent fatigue life can be obtained. It will be applied to make and improve to a short period for design and prototype test.

  • PDF

A Study on the Reduction of Cogging Torque of Outer-Rotor Type BLDC Motor for Washing Machines (세탁기용 외전형 BLDC 전동기의 코깅 토오크 저감에 관한 연구)

  • Kim Jae-Min;Chang Cheul-Hyeok;Chung Tae-Kyung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.5
    • /
    • pp.222-230
    • /
    • 2005
  • This paper deals with the reduction of cogging torque of a outer-rotor type BLDC motor mainly used for washing machines. The motor comprises permanent magnet outer-rotor and stator with coils and core. This structure inherently produces vibration and cogging torque because of uneven reluctance according to rotation of the rotor. Up to now, adopted a type of 24 magnet pole and 36 slot-stator. This generates high main torque but accompanies comparatively large cogging torque. This paper proposes a 32-pole 36-slot type motor which reduces cogging torque remarkably. The influence of cogging torque is varied according to pole-slot combinations. The characteristic of the motor was obtained by a two-dimensional finite element method coupled with a drive circuit. The performance of the proposed model is superior to that of the existing model because of the reduction of torque ripple and the improvement of back ernf wave form.

Preparation of Low Density Water Glass Based Silica Gels by Conventional Drying

  • Einarsrud, Mari-Ann;Elin Nilsen
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • To reduce shrinkage and the possibility of fracture during ambient pressure drying, it is of great importance to increase the strength and stiffness of the wet gels. In this paper is presented the strengthening and stiffening of wet silica gels prepared from sodium silicate (water glass) as well as properties of the corresponding xerogels. By washing gels containing different initial silica contents in water solutions at elevated pH, a maximum in shear modulus of ~4 MPa was obtained. The maximum stiffness enabled xerogels with bulk density of 0.28g/$\textrm{cm}^3$ to be made regardless of silica content and washing conditions. However, by aging the wet gels in a solution providing fresh monomers to the gel network, a shear modulus of 20 MPa was obtained after 27h. By this method monolithic xerogels with a density down to ~0.2g/$\textrm{cm}^3$ was prepared. The results are compared to alkoxide based gels.

  • PDF

The evaluation of vibration contribution about the eccentric rotor system by multiple dimensional spectral analysis (다차원 해석법을 이용한 편심 회전체의 전달 기여도 평가)

  • 조문갑;조용구;김동원;이정윤;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.298-303
    • /
    • 2003
  • The eccentric rotor system has various problems by vibration of unbalance mass. Specially, it is difficult to analyze vibration problem for the drum washing machine due to correlation of transmission paths. We analyze the mechanical structure by multidimensional spectral density to identify the maximum vibration magnitude at the frequency domain. It estimates the coherence function of the signals to pass the transmission paths. In case of the drum washing machine, because the transmission paths are correlated partially it needs to determinate the priority ranking. And the correlated parts are eliminated using conditioned spectral density function. Finally the shielding effect method confirms the reasonability of the modeling.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF