• Title/Summary/Keyword: Washing Column

Search Result 51, Processing Time 0.022 seconds

Column filled with Fe-GAC and GAC to remove both As(V) and Fe(III) (비소와 철 동시제거를 위한 Fe-GAC와 GAC로 충진된 컬럼)

  • Lee, Yong-Soo;Do, Si-Hyun;Hong, Seong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.87-97
    • /
    • 2016
  • First of all, Fe or/and Mn immobilized granular activated carbons (Fe-GAC, Mn-GAC, (Fe, Mn)-GAC) were synthesized and tested to remove arsenate (As(V)). The results in batch test indicated that Fe-GAC removed As(V) effectively, even though the surface area of Fe-GAC was reduced largely. Moreover, adsorption isotherm test indicated that the experimental data fit well with Langmuir model and the maximum adsorption capacity ($q_{max}$) of Fe-GAC for As(V) was $3.49mg\;g^{-1}$, which was higher than GAC ($2.24mg\;g^{-1}$). In column test, the simulated water, which consisted of As(V), Fe(III), Mn(II) and Ca(II) in tap water, was used. Fe-GAC column with 1 hr of pre-washing time treated As(V) effectively while GAC column removed Fe(III) better than Fe-GAC column. Moreover, the increasing pre-washing time from 1 to 9 hour in Fe-GAC column enhanced Fe(III) removal with little negative impact of As(V) removal. Mostly, the column filled with Fe-GAC and GAC (i.e. the mass ratio of Fe-GAC:GAC = 2:8) showed the higher treatability of both As(V) and Fe(III), even it operated with 1 hr pre-washing time.

HCl, Surfactant (SDS, Tween 80) Enhanced Remediation of Contaminated Soil with Lead and Copper (계면활성제 (SDS, Tween 80)와 HCl을 활용한 중금속 오염 토양의 복원)

  • 조미영;현재혁;백정선
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.12-15
    • /
    • 1999
  • Soils collected from an agricultural field in Youngdong, Chungbuk province were intentionally: contaminated with lead and copper. The efficiencies of soil washing with HCl, SDS and Tween 80 were investigated through the column mode experiments. Washing with 0.1 N HCl obtained the best result for lead and copper removal (95.04 %, 95.94 %). In case of SDS, lead and copper removal rate was such poor as 7.1 % and copper was 24.04 %, respectively. Meanwhile, washing of contaminated soil with Tween 80, did not show any significant removal effect. It was found that the washing efficiency was dependent on pH of washing agent.

  • PDF

Remediation of Insecticides (Parathion, Diazinon) Contaminated Soil by Washing Process (토양 세척을 통한 살충제 (파라티온, 다이아지논)로 오염된 토양의 정화)

  • 현재혁;백정선;조미영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1999.10a
    • /
    • pp.3-6
    • /
    • 1999
  • Several chemical washing procedures were applied to Parathion and Diazinon contaminated soil. Batch and column tests were performed to determine the insecticides extraction efficiency as a function of pH. Washing efficiency of methanol is more higher than that of water and HCl when washed parathion and diazinon are. Those are completely miscible with most organic solvents. For parathion, release trend is increased as pH is increased because it is hydrolyzed easily at the condition of alkali. But diazinon shows reverse because diazinon is decomposed rapidly at the condition of acidic So, diazinon is more released than parathion is because this experiment is peformed in acidic and weak acidic conditions. Generally, parathion and diazinon are classified as having low mobility, so they can be easily controlled if the proper washing process are applied.

  • PDF

Peptide Production from the Washing Liquid of the Fish Paste of Alaska pollak (Theragria chalcogramma) by Immobilized Enzyme (고정화 효소를 이용한 명태고기풀 수세액으로부터 Peptide 생산에 관한 연구)

  • SHIN Suk-U;SUETSUNA Kunio
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.3
    • /
    • pp.466-472
    • /
    • 1997
  • Peptides separated from fish paste washing liquid of an Alaska pollak (Theragria chalcogramma) were purified and characterized. The fish paste washing liquid (supernatant) was separated by centrifugation of fish paste homogenate. The fish paste washing liquid of $0.5\%$ concentration was hydrolyzed for 24 hour at $50^{\circ}C$ by immobilized protease in bioreactor and decomposing liquid of protein having $50\%$ decomposing rate (OPA method) was obtained. The crude peptide fractions were obtained from this liquid by Dowex 50w $(H^+)$ column chromatograpy. Purified peptides (SP-fraction peptides) were fractionated by using SP-Sepadex C-25 $(H^+)$ column chromatography. Molecular weights and amino acid compositions of these peptides were estimated by Sephadex G-50 column chromatography and HPLC, respectively. when the washed peptides was eluated with $0.6\~0.9\%\;and\;1.2\~2.0\%$ of NaCl, peptides composed of weakly basic amino acids and strongly basic amino acid were respectively eluted. Molecular weights of each peptide fractions showed the broad distribution from 1,000 Da to 3,000 Da in the order of SP-4>SP-3>SP-2>SP-1. Peptides contained a large quantity of glycine, arginine, glutamic acid, and alanine in the washed peptide and its SP-tractions, respectively.

  • PDF

CHEMICAL DECONTAMINATION OF SOIL CONTAMINATED WITH Cs-137

  • H. J. Won;Kim, G. N.;C. H. Jung;Park, W. K.;Kim, M. G.;W. Z. Oh;Park, J. H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.83-95
    • /
    • 2004
  • The removal efficiency of several washing agents on the $Cs^+$ ion was investigated. Leaching of $Cs^+$ ion from the soil surface by washing agents is affected by the exchange capability of the washing solution. Reuse tests of the effective soil washing agents such as $BaCl_2$, NaOH, citric acid+ $HNO_3$ and oxalic acid were performed. NaOH, citric acid + $HNO_3$ and oxalic acid solutions can be reused after passing through the ion exchange column. Among the tested solutions, both of citric acid+ $HNO_3$ and oxalic acid were effective for the decontamination of TRIGA research reactor soil. The radioactivity of soils can be reduced to a release level by the successive application.

  • PDF

Development of Oil Separation Process from Oily Waste Water Using Oil Gelling Agent (유류고형화제에 의한 유함유 폐수 중의 유류 제거 공정 개발)

  • 주창식;홍성수;황덕기;김영일;박흥재;정성욱
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.401-405
    • /
    • 2001
  • For the purpose of developing a new process f3r the elimination of oil components from oily waste water, experimental researches using oil gelling agent were performed. The process is composed of three units, that is, decantator, gelling column and adsorption column. 10g of gelling agent in the gelling column could effectively absorb 15.65g of oil from ship washing waste water and 16.93g of oil from steel industry waste water. COD in waste waters dramatically diminished not in the gelling column but in the adsorption column. The .gelling is hindered by other organic components in waste water, and the optimum space time f3r the gelling column Is 20min. 1g of gelling agent absorbed 3.7-4.0g of oil from waste waters with 25 min in the batch operation.

  • PDF

The Effect of Designing Washing Column in Post Combustion CO2 Capture Plant on the Losses of Amine Solvent (습식아민 CO2 포집설비의 물 세정 단 설계에 따른 흡수제 손실 영향 평가)

  • Han, Sun-Gu;Ko, Hyun-Shin;Kim, Sung-Kyu;Choi, Si-Mook
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.34-38
    • /
    • 2017
  • To reduce global warming, there are so many studies, investments and efforts. The Post Combustion $CO_2$ Capture technology is one of these efforts. But the technologies are having trouble with reducing operating prices. And CCS technology which is using amine solvent uses high price amine solvent. There is solvent losses naturally when operating plant. The solvent loss makes operating and maintenance price higher. In this study, how the washing column of treated flue gas affects the losses of amine solvent and operating was studied.

  • PDF

Effect of Spinal Cord Removal before or after Splitting and Washing on CNST Decontamination of Beef Carcasses

  • Lim, D.G.;Kim, D.H.;Lee, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.11
    • /
    • pp.1770-1776
    • /
    • 2007
  • Beef carcasses were examined to explore the effects of spinal cord removal and washing on central nervous system tissue (CNST) decontamination of the surface during the slaughtering process. A total of 15 carcasses were split by sawing centrally down the vertebral column and left sides of split carcasses were used for analysis. Samples were collected by swabbing the surface from 4 defined parts on the interior and 4 on the exterior of carcasses from the abattoir and analyzed using an ELISA-based test. The results showed that automatic and manual spray washing decreased CNST contamination, especially on the interior ventral parts of carcass surfaces (p<0.01), but did not decrease CNST on the interior dorsal parts. Increasing washing time to 60 s did not affect the reduction of CNST contamination. Samples following spinal cord removal prior to splitting showed lower calculated levels of "risk material" than the stated limit of detection (0.1%) of the ELISA kit on interior and exterior carcass parts (p<0.01). Therefore, spinal cord removal prior to splitting could be a very effective way to minimize CNST contamination of beef carcasses.

On-line Trace Enrichment for the Determination of Insulin in Biological Samples Using Reversed-Phase High Performance Liquid Chromatography with Column Switching

  • Lee, Jung-Sook;Lee, Heeyong;Lee, Hye-Suk;Lee, Kang-Choon
    • Archives of Pharmacal Research
    • /
    • v.17 no.5
    • /
    • pp.360-363
    • /
    • 1994
  • Column--swtiching technique with a reversed-phase high performance liquid chromatographic method has been developed for the routine analysis of radioiodinated insulin and its degadation products in biological fluids. The diluted biological samples were loaded onto a precolumn packed with LiChrosorb RP-8 $(25-40{\;}{\mu}m)$ using 0.1% trifuoroacetic acid (TFA) in water as a washing solvent. After valve switching, the concentrated insulins were eluted in the back-flush mode and separated by a W-Porex $C_{18}$ column with a gradient of 0.1% TFA in water and 0.1% TFA in acetonitrile as the mobile phase. The method showed good precision, accuracy and speed with the detection limit of 20 pg/ml. Total analysis time per sample was about 40 min and the coefficients of variation were less than 8, 2%.

  • PDF

Remediation of Heavy Metal Contaminated Soil by Washing Process (세척을 통한 중금속(Cd, Zn)으로 오염된 토양의 정화)

  • 백정선;현재혁;조미영;김수정
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.1
    • /
    • pp.45-54
    • /
    • 2000
  • Several chemical washing procedures were applied to Zn and Cd contaminated soil. Batch and column tests were performed to determine the metal extraction efficiency as a function of pH and concentration. Washing efficiencies by water and NaOH are very low but those by HCI, EDTA and Oxalic acid are high. The most efficient washing occurs in case of using HCI because heavy metal is ionized easily at the condition of low pH. EDTA and Oxalic acid are also effective to extract Zn and Cd because they have a high complexation affinity for heavy metals forming active surface complexes. More Zn is released than Cd is and release trend is increased as pH is decreased and concentration of washing solution is increased. When heavy metal contaminated soil is remediated, HCI and EDTA are more effective to remove Zn than others are. Meanwhile HCI and Oxalic acid are more effective to remove Cd than others are.