• Title/Summary/Keyword: Warm Water Method

Search Result 89, Processing Time 0.027 seconds

Solar Energy Storage Effectiveness on Double Layered Single Span Plastic Greenhouse (2중 단동비닐하우스의 태양열 축열이용 효과)

  • Lee, Sung-Hyoun;Ryou, Young-Sun;Moon, Jong-Pil;Yun, Nam-Kyu;Kwon, Jin-Kyung;Lee, Su-Jang;Kim, Kyeong-Won
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.217-222
    • /
    • 2011
  • This study was carried out in order to reduce the amount of underground water which is used in the double layered single span plastic greenhouse for retaining heat. For this research, two plastic green houses of the double layered single span plastic greenhouse were installed. There was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50 cm in diameter filled with subsurface water. The surplus solar energy in the greenhouse was stored in the water in the PVC duct. Four FCUs (Fan Coil Unit), which has the capacity of 8,000 kcal per hour, were installed in the middle of the house, and a circulation motor in heat storage water tank was operated from 10:30 a.m. to 16:00 p.m. in order to circulate water between the water tank and the FCUs. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of lower than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. To prevent the water freezing, mixing antifreezing liquid in the water or operating FCU continuously was needed. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Considering the amount of water used in the house with water-curtain-heating system is 150~200 ton per day, using the system mentioned in this research showed that reducing the underground water more than 80% in order to maintain the internal temperature as the level of 5 degree celsius at the extreme temperature of minus 5 degrees celsius.

Steady and Transient Solution of heat Conduction from hurried Pipes of panel heating Slab (상-파넬 히-팅의 해석법)

  • Lee Kun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.3 no.3
    • /
    • pp.185-190
    • /
    • 1974
  • Floor panel heating system is popular in Korea as dwelling house heating system. There are two methods for keeping floor surface warm. One method is delivering warm air under the floor such as Roman Hypocaust and Korean traditional Ondol. The other method is imbedding hot water pipes into the concrete floor slab. This paper gives basic equations for steady and transient solutions of heat conduction from hurried pipes. For steady-state solution, fin Efficiency Method and Sink and Source Method were introduced. Sink and Source Method is applied to transient state and basic solution is given in the form of Exponential Integral Function. Numerical solutions can be solved easily by digital computer from these equations.

  • PDF

Effect Oxygen in Inflation Gas for Warm Ischemia-reperfusion Injury in the Lung of a Mongrel Dog (황견에서 폐장의 산소가 온열 허혈후 재관류 시폐손상에 미치는 영향)

  • 성숙환;김현조;김영태
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.125-131
    • /
    • 2000
  • Background: Hyperinflation during lung ischemia has been known to improve pulmonary functions after reperfusion which may be exerted through a pulmonary vasodilation and avoidance of atelectasis by an increased surfactant release and been known whether the improvement of pulmonary function was the effect of hyperinflation itself or the oxygen content in inflation gas. Therefore we attempted to clarify the effect of hyperinflation with oxygen in pulmonary inflation gas during warm ischemia on pulmonary function after reperfusion to solve the problem of ischemia-reperfusion injury after lung transplantation. Material and Method: sixteen mongrel dogs were randomly divided into two groups: the left lung was inflated to 30-35 cm H2O with 100% oxygen in oxygen group and 100% nitrogen in nitrogen group. The inflated left lung was maintained with warm ischemia for 100 minutes. Arterial and mixed venous blood gas analysis and hemodynamics were measured before ischemia and 30, 60, 120, 180 and 240 minutes afer reperfusion. Lung biopsy was taken for the measurement of lung water content after the end of reperfusion. Result: In oxygen group arterial oxygen tension the difference of arterial and mixed venous oxygen tension and the difference of alveolar-arterial oxygen tension at 30-minute after reperfusion were not significantly different from those before ischemia and were stable during the 40hour reperfusion. However in nitrogen group these values were significantly deteriorated at 30-minute after reperfusion. there was no significant difference between two groups in hemodynamic data peak airway pressure and lung water content. Conclusion : The results indicated that the oxygenation one of the most important pulmonary functions was improved by pulmonary inflation with 100% oxygen during warm ischemia but the hemodynamics were not. Oxygen as a metabolic substrate during warm ischenia was believed to make the pulmonary tissues to maintain aerobic metabolism and to prevent ischemic damage of alveoli and pulmonary capillary.

  • PDF

Biotope Analysis of the Total Benthic Foraminiferal Assemblage off the Southeastern Coast, Korea (한국남동해 저서유공충의 생물장)

  • 장순권
    • 한국해양학회지
    • /
    • v.21 no.3
    • /
    • pp.136-145
    • /
    • 1986
  • Biotope analysis(UPGM) of the data on the total benthic foraminferal assemblage (Kim and Han, 1982) collected from the southeastern sea off the Korean Peninsula shows that foraminiferal assemblages are related to the water masses prevailing in the study area. South Proper facies is governed by the Tsushima Warm Current, and Southern Deep facies is influenced by the cold water mass moved down along the bottom. Northern Nearshore facies is governed by the North Korea Cold Current, and North Proper facies is affected by the North Korea Cold Current and Japan Sea Proper Water. It is also evident that the upper part of the study area is under the influence of the North Korea Cold Current rather than the East Korea Warm Current which flows northward along/or off the right side of the study area. Planktonic foraminiferal occurrence also supports this biotope analysis.

  • PDF

Compressive strength prediction of concrete using ground granulated blast furnace slag by accelerated testing (촉진양생법에 의한 고로슬래그 미분말 혼합 콘크리트의 압축강도 예측)

  • Kim, Yong Jic;Kim, Young Jin;Choi, Yun Wang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.91-98
    • /
    • 2009
  • Recently, production cost of ready mixed concrete has been increased due to the rising cost of raw materials such as cement and aggregate etc. cause by the upturn of oil price and increase of shipping charge. The delivery cost of ready mixed concrete companies, however, has been decreased owing to their excessive competition in sale. Consequently, ready mixed concrete companies began to manufacture the concrete by mixing ground granulated blast furnace slag(GGBF) and fly-ash in order to lower the production cost. Therefore, the objective of this study was to predict 28 days strength of GGBF slag concrete by early strength(warm and hot water curing method) for the sake of managing with ease the quality of ready mixed concrete. In experimental results, the prediction equation for 28 days compressive strength of GGBF slag concrete could be produced through the linear regression analysis of early strength and 28 days strength. In order to acquire the reliability, all mixture were repeated as 3 times and each mixture order was carried out by random sampling. The prediction equation for 28 days strength of GGBF slag concrete by 1 day compressive strength(accelerated testing) according to warm and hot water curing method won the good reliability.

  • PDF

Method for high temperature curing and strength development of high strength concrete micropores Relationship (고온 양생방법을 이용한 고강도 콘크리트의 미세공극과 강도발현 관계에 대한 연구)

  • Lee, Han Yong;Kim, Seong Deok;Lee, young Do;Myung, Ro Oun;Jung, Sang Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.58-59
    • /
    • 2013
  • In this study, the standard specimen heated to curing experiments and simulation experiments the absence of porosity distribution and the effect on the compressive strength has been investigated.

  • PDF

Application of Geostatistical Analysis Method to Detect the Direction of Sea Surface Warm Flows (해수면 난류수 유동방향 탐지를 위한 지구통계학적 분석기법 적용)

  • Choi, Hyun-Woo;Kim, Hyun-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.1
    • /
    • pp.168-178
    • /
    • 2006
  • In recent years, an ingress of mass jellyfish into cooling water intake system causes interruption of electric power production at the Uljin nuclear power plant. Therefore, monitering and forecast on the mass ingress of marine organisms are demanded as one of the early preventing measurements. Sea water movement is a major factor on the ingress of marine organisms like Moon jellyfish which has weak self-mobile ability. When sea surface flow direction adjacent to the Uljin is the northwest, the jellyfish on the Tsushima warm currents move to the Uljin power plant. To detect the direction of sea surface warm flows, the spatial range with $25km{\times}25km$ is set up and NOAA sea surface temperature(SST) data are collected in this area. For the statistical analysis, the SST data are made as GIS point data and geostatistical analysis of ArcGIS is used. Analyzing directional semivariogram, the anisotropy of the SST point data are calculated and warm flow direction is detected. This experimental results are expected to use as an element technology for the early warning system development of mass jellyfish ingress in power plant.

  • PDF

Premenstrual Discomforts and Coping in University Students (여대생의 월경전 불편감과 대처에 관한 연구)

  • Ahn, Hye-Young;Hyun, Hye-Jin;Kim, Hae-Won
    • Research in Community and Public Health Nursing
    • /
    • v.16 no.3
    • /
    • pp.289-299
    • /
    • 2005
  • Purpose: This study was carried out to identify premenstrual discomforts and coping patterns and their effects. Method: The participants of this study were 297 female university students in C area. The Menstrual Discomfort Questionaire (MDQ) and coping method lists were used as measurement tools. Results: There were significant differences premenstrual discomforts according to age (F=5.76, p=.003) and according to health condition (F=3.43, p=.034). The mean scores of the sub-categorical factors of premenstrual discomfort were 2.35 points for pain, 2.29 for instability and 2.25 for water retention. The worst symptoms among the subcategories of premenstrual discomfort were as follows: backache (M=2.68) in the pain subcategory, irritability (M=2.53) in the instability subcategory and swelling(M=2.40) in the water retention subcategory. Their common coping patterns were 'coping according to menstrual period', 'active behavioral coping' and 'evasional coping'. Frequently used coping methods were 'taking a rest and sleep (99.3%)' and 'taking a warm shower (86.2%)'. Effective coping methods were 'taking a rest and sleep (89.5%)' and 'taking a warm shower (87.1%)'. Conclusion: Most participants have their own coping pattern. Some methods were very effective to PMS but some were not effective to PMS. To manage PMS, effective coping methods should be encouraged for female university students. To keep up with effective coping, education and counseling should be continued. It is considered necessary to make the same research with a larger number of samples and more specified assessment.

  • PDF

Effects of Using Illite Warm Water Mats on Lactate, CRP and ACR Induced High Intensity Exercise in Adults (일라이트 온수매트 사용이 고강도 운동으로 유발된 성인의 젖산, CRP, ACR에 미치는 영향)

  • Choi, Youngjun;Kim, Hyunjun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.133-142
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effective recovery method of exercise-induced fatigue and muscle pain by comparing the effect of the use of illite hot mat product and general hot mat product on the recovery of muscle pain induced by high intensity exercise. Methods : To measure and analyze the changes in lactic acid, CRP, and ACR according to the high-intensity circuit training program, this study was conducted for the healthy adult men and women, who exercise st the K-region sports center. A total of 45 subjects were studied in 15 groups of 15 patients who received an illite hot-water mat recovery group (A group), 15 general hot-water mat recovery group (B group), and 15 control group (C group). The circuit training exercise program was conducted as a one-time exercise, and each exercise time consisted of 30 minutes of warm-up exercise, 5 minutes of main exercise, 20 minutes of clean-up exercise, and 5 minutes of strength exercise. The intensity setting was high intensity of subjective exercise intensity It carried out by setting to (14-16RPE). Results : Changes in Lactic Acid Concentration There was a significant difference in the lactic acid concentrations between the groups after the high intensity circuit training program (p <.05). The illite rest group (A) decreased 7.71 mmol / L and the control group decreased 4.03 mmol / L. Significantly decreased (p <.05). Changes in ACR Concentration. There was a significant difference in the ACR concentrations Significant differences were found in CRP and ACR during the recovery period after exercise. (p <.05), the elite rest group (A) decreased 2.47 mg / mmol, and the control group increased 1.63 mg / mmol. There was a significant difference (p <.05). Conclusion: The static rest on a heated mat after high-intensity exercise has an effect on changes in blood lactate and ACR levels.