• Title/Summary/Keyword: Walls

Search Result 4,331, Processing Time 0.029 seconds

Excremental Study on Wave Drag in Supersonic Wavy Walls (초음속 파동 벽면에서의 조파저항에 관한 실험적 연구)

  • Kwon, Min-Chan;Semenov, Vasily V.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.758-759
    • /
    • 2010
  • In this study, it was experimentally confirmed that the phenomenon of resonance effect of wave drag in two wavy walls. The channel had saw-tooth type of relief surfaces when supersonic gas flows into this channel. Experiment was carried out on the differential apparatus by conducting the comparative test of two nozzles (round sonic nozzle and two-dimensional nozzle with wavy walls). The two-dimensional nozzle was joined alternately with flat walls which had saw-tooth type of symmetrical and asymmetric reliefs. Two-dimensional nozzle was designed for the M=3 and profiled parabolic contour.

  • PDF

Cracking behavior of RC shear walls subject to cyclic loadings

  • Kwak, Hyo-Gyoung;Kim, Do-Yeon
    • Computers and Concrete
    • /
    • v.1 no.1
    • /
    • pp.77-98
    • /
    • 2004
  • This paper presents a numerical model for simulating the nonlinear response of reinforced concrete (RC) shear walls subject to cyclic loadings. The material behavior of cracked concrete is described by an orthotropic constitutive relation with tension-stiffening and compression softening effects defining equivalent uniaxial stress-strain relation in the axes of orthotropy. Especially in making analytical predictions for inelastic behaviors of RC walls under reversed cyclic loading, some influencing factors inducing the material nonlinearities have been considered. A simple hysteretic stress-strain relation of concrete, which crosses the tension-compression region, is defined. Modification of the hysteretic stress-strain relation of steel is also introduced to reflect a pinching effect depending on the shear span ratio and to represent an average stress distribution in a cracked RC element, respectively. To assess the applicability of the constitutive model for RC element, analytical results are compared with idealized shear panel and shear wall test results under monotonic and cyclic shear loadings.

Seismic behavior of RC building by considering a model for shear wall-floor slab connections

  • Soleimani-Abiat, Mehdi;Banan, Mohammad-Reza
    • Computers and Concrete
    • /
    • v.16 no.3
    • /
    • pp.381-397
    • /
    • 2015
  • Connections are the most important regions in a structural system especially for buildings in seismic zones. In R.C. structures due to large dimensions of members and lack of cognition of the stress distribution in a connection, reaching a comprehensive understanding of the connection behaviors becomes more complicated. The shear wall-to-floor slab connections in lateral load resisting systems have a potential weakness in transferring loads from slabs to shear walls which might change the path of load transformation to shear walls. This paper tries to investigate the effects of seismic load combinations on the behavior of slabs at their connection zones with the shear walls. These connection zones naturally are the most critical regions of the slabs in RC buildings. The investigation carried on in a simulated environment by considering three different structures with different shear wall layout. The final results of our study reveal that layout of shear walls in a building significantly affects the magnification of forces developed at the shear wall-floor slab connections.

Experimental study on infilled frames strengthened by profiled steel sheet bracing

  • Cao, Pingzhou;Feng, Ningning;Wu, Kai
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.777-790
    • /
    • 2014
  • The purpose of this study is to investigate the seismic performance of reinforced concrete (RC) frames strengthened by profiled steel sheet bracing which takes the influence of infill walls into consideration. One-bay, two-story, 1/3 scale two specimens shared same feature of dimensions, one specimen consists only beams and columns; the other one is reinforced by profiled steel sheet bracing with infill walls. Hysteretic curves, envelope curves, stiffness degradation curves and energy dissipation capacities are presented based on test data. Test results indicate that the ultimate load of strengthened specimen has been improved by 225%. The stiffness of reinforced by profiled steel sheet bracing has been increased by 108%. This demonstrates that infill walls and profiled steel sheet bracing enhanced the strength and stiffness distinctly. Energy dissipation has an obvious increase after 12 cycles. This shows that the reinforced specimen is able to bear the lateral load effectively and absorb lots of seismic energy.

A numerical study on behavior of CFRP strengthened shear wall with opening

  • Behfarnia, Kiachehr;Shirneshan, Ahmadreza
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.179-189
    • /
    • 2017
  • Concrete shear walls are one of the major structural lateral resisting systems in buildings. In some cases, due to the change in the occupancy of the structure or functional requirements like architectural and even mechanical ones, openings need to be provided and installed in structural walls after their construction. Providing these openings may significantly influence the structural behavior of the constructed wall. This paper considers the results of a nonlinear finite element analysis of shear walls with opening strengthened by carbon fiber reinforced polymer (CFRP) strips with different configurations. Details of bond-slip constitutive model of link elements to simulate the connections of FRP strips to concrete surface is presented. The proposed model in this research has been validated using experimental results available in the literature. The results indicated that the proposed configuration of CFRP strips significantly improved the lateral resistance and deformation capacity of the shear walls with opening.

Infill wall effects on the dynamic characteristics of RC frame systems via operational modal analysis

  • Komur, Mehmet A.;Kara, Mehmet E.;Deneme, Ibrahim O.
    • Structural Engineering and Mechanics
    • /
    • v.74 no.1
    • /
    • pp.121-128
    • /
    • 2020
  • This paper presents an experimental study on the dynamic characteristics of infilled reinforced concrete (RC) frames. A 1/3-scaled, one-bay, three-storey RC frame was produced and tested by using operational modal analysis (OMA). The experiments were performed on five specimens: one reference frame with no infill walls and four frames with infill walls. The RC frame systems included infill walls made of hollow clay brick, which were constructed in four different patterns. The dynamic characteristics of the patterns, including the frequency, mode shapes and damping ratios in the in-plane direction, were obtained by 6 accelerometers. Twenty-minute records under ambient vibration were collected for each model, and the dynamic characteristics were determined using the ambient vibration testing and modal identification software (ARTeMIS). The experimental studies showed that the infill walls significantly affected the frequency value, rigidity and damping ratio of the RC frame system.

Seismic assessment of thin steel plate shear walls with outrigger system

  • Fathy, Ebtsam
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.267-282
    • /
    • 2020
  • The seismic performance and failure modes of the dual system of moment resisting frames and thin steel plate shear walls (TSPSWs) without and with one or two outrigger trusses are studied in this paper. These structural systems were utilized to resist vertical and lateral loads of 40-storey buildings. Detailed Finite element models associated with nonlinear time history analyses were used to examine seismic capacity and plastic mechanism of the buildings. The analyses were performed under increased levels of earthquake intensities. The models with one and two outriggers showed good performance during the maximum considered earthquake (MCE), while the stress of TSPSWs in the model without outrigger reached its ultimate value under this earthquake. The best seismic capacity was in favour of the model with two outriggers, where it is found that increasing the number of outriggers not only gives more reduction in lateral displacement but also reduces stress concentration on thin steel plate shear walls at outrigger floors, which caused the early failure of TSPSWs in model with one outrigger.

Analysis of the False Diffusion Effects in Numerical Simulation of Diesel Spray Impinging on Inclined Walls (경사진 벽충돌 디젤 분무에 대한 수치해석에서 오류확산이 미치는 영향)

  • Gwon, H.R.;Lee, S.H.
    • Journal of ILASS-Korea
    • /
    • v.13 no.1
    • /
    • pp.22-27
    • /
    • 2008
  • The false diffusion occurs generally when the flow is oblique to the grid lines and when there is a non-zero gradient of the dependent variable in the direction normal to the flow. This numerical problem can overestimate diffusion terms in the continuous phase, causing the numerical inaccuracy for the simulation of impinging sprays on inclined walls because most of spray calculation uses rectangular grid system. Therefore, the main objective of this article is to investigate numerically the influence of false diffusion on numerical simulation for spray-wall impingement on inclined walls. It is found that unlike the spray impingement normal to the wall, the numerical diffusion exists in the case when diesel sprays impinge on the inclined walls with different angles. The results show that the correction function should be considered for accurate prediction of spray penetration length and more elaborate numerical schemes should be utilized to reduce the false diffusion.

  • PDF

Seismic Response Analysis of Lightly Reinforced Concrete Shear Walls

  • Rhee, In-Kyu
    • International Journal of Railway
    • /
    • v.3 no.2
    • /
    • pp.73-82
    • /
    • 2010
  • Global and local behaviors of a lightly RC shear walls are investigated in this paper. For the sake of cyclic behaviors, nominal ground accelerations of 0.15 g, 0.40 g and 0.55 g which associated with natural periods of the walls are applied as listed in French CAMUS-2000 shake table test. Modified Kent & Park model, Drucker-Prager model for concrete material and $Giufr\acute{e}$-Menegotto-Pinto model for rebar are used for time history analyses using fiber/solids elements respectively. Alternatively, Eulerian beam analysis are discussed by imposing inelastic hinges at the most possible plastic hinge location using modified Takeda's trilinear model with stiffness reduction. Relative displacements, base shears, bending moments of 5-story shear building with 36-tons of mass under bi-lateral seismic excitation are extracted and compared with EC-8, PS-92 and KBC-09 provisions. Multi-scaled degradation process; material damage, elemental fracture and structural failure in turn is discussed in the view of numerical accuracy, efficiency and limitation depending on three different model-based analyses.

  • PDF

Experimental Study for Higher Seismic Performance of Confined Masonry Wall System (주변이 RC로 구속된 조적조 벽체의 내진성능향상에 관한 실험적 연구)

  • Kim Kyong-Tae;Seo Soo-Yeon;Yoon Seung-Joe;Yoshimura Koji;Sung Ki-Tae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.5-8
    • /
    • 2004
  • In order to investigate the effect of the height of application point of lateral loads and reinforcing steel bars in walls and columns in improving the seismic behavior of confined concrete block masonry walls, an experimental research program is conducted. A total of four one-half scale specimens are tested under repeated lateral loads. Specimens are tested to failure with increasing maximum lateral drifts while a vertical axial load was applied and maintained constant. The constant vertical axial stresses applied are 0, 0.84 and 1.80MPa, while the amount of reinforcements in horizontal and vertical directions are $0\%,\;0.08\%\;and\;0.18\%$ respectively. Test results obtained for each specimen include cracking patterns, load-deflection data, and strains in reinforcement and walls in critical locations. Analysis of test data showed that above parameters generate a considerable effect on the seismic performance of confined concrete block masonry walls.

  • PDF