• 제목/요약/키워드: Wall thickness

검색결과 1,548건 처리시간 0.033초

산화아연 나노선과 나노튜브의 구조 및 탄성계수에 관한 원자단위 연구 (Atomistic simulation of structural and elastic modulus of ZnO nanowires and nanotubes)

  • 문원하;최창환;황호정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.429-429
    • /
    • 2008
  • The structural stability and the elastic modulus of hexagonal ZnO nanowires and nanotubes are investigated using atomistic simulations based on the shell model. The ZnO nanowire with (10-10) facets is energetically more stable than that with (11-20). Our calculations indicate that the structural change of ZnO nanowires with (10-10) facets is sensitive to the diameter. With decreasing the diameter of ZnO nanowires, the unit-cell length is increased while the bond-length is reduced due to the change of surface atoms. Unlike the conventional layered nanotubes, the energetic stability of single crystalline ZnO nanotubes is related to the wall thickness. The potential energy of ZnO nanotubes with fixed outer and inner diameters decreases with increasing wall thickness while the nanotubes with same wall thickness are independent of the outer and inner diameters. The transformation of single crystalline ZnO nanotubes with double layer from wurtzite phase to graphitic suggests the possibility of wall-typed ZnO nanotubes. The size-dependent Young's modulus for ZnO nanowires and nanotubes is also calculated. The diameter and the wall thickness play a significant role in the Young's modulus of single crystalline ZnO nanowires and nanotubes, respectively.

  • PDF

외벽측 급수관의 동결 과정에 관한 연구 (The Freezing Process of the Water Supply Pipe in an Exterior Wall)

  • 강한기;이재헌
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.782-788
    • /
    • 2007
  • In this paper, the freezing process of the water supply pipe in the exterior wall of an apartment house was analyzed by numerical method. The thickness of the pipe insulation and the percentage of insulation damage were considered as parameters in this paper. In the cases of the 0%, 8% and 20% damaged of the 5mm thickness insulation, the freezing was completed after 13 hours, 10 hours and 7 hours respectively. And in cases of the 10mm thickness insulation, the freezing was completed after 18 hours, 10.5 hours and 8 hours respectively. As a result, it is predicted that the water freezing would occurred when the water supply pipe with 8% or 20% damaged insulation are installed in the exterior wall. However, the water freezing would not occurred when the water supply pipe with 10mm thickness insulation of 0% damage is installed in the exterior wall.

진동차단공의 재료별 방진효과에 관한 해석적 연구 (Analytical Study on the Isolation Effects of Bore Holes by Materials)

  • 이강일
    • 한국지반신소재학회논문집
    • /
    • 제5권2호
    • /
    • pp.23-30
    • /
    • 2006
  • 본 연구는 환경진동으로 유발되는 진동 대책 중 전파 경로상에 방진구나 방진벽 등과 같은 진동차단벽을 설치했을 경우 차단벽의 재료를 방진구, 콘크리트, EPS, 철로 변화시켜 유한요소해석을 수행하여 진동을 가장 효율적으로 저감시킬 수 있는 재료 및 차단벽의 규모(타설심도, 차단벽두께, 진원으로부터의 거리)에 대하여 연구하였다. 본 연구 결과 방진구의 경우는 차단벽의 두께의 영향보다는 차단벽의 타설심도에 영향이 크고, 콘크리트의 경우에는 다른 방진벽의 방진효과에 비해 방진효과가 떨어진다. 또한 EPS의 경우는 타설심도 보다는 차단벽두께의 영향이 진동차단에 더 효과적임을 알 수 있었다.

  • PDF

Corner Steel plate-Reinforced Core Wall System

  • Park, Hong-Gun;Kim, Hyeon-Jin;Park, Jin-Young
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.193-199
    • /
    • 2019
  • For better structural performance and constructability, a new composite core wall system using steel plate columns at the corners of the core section was developed. Using the proposed core wall, nonlinear section analysis and 3-dimensional structural analysis were performed for the prototype core wall section and super high-rise building, respectively. The analysis results showed that, when compared to traditional RC core wall case, the use of the corner steel plate columns provided better structural capacity, which allows less wall thickness and re-bars. Further, due to such effects, the construction cost and time can be reduced despite the use of steel plate columns.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 V, 도축우에서 난소낭종의 감별진단 (Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows V, Differential Diagnosis of Ovarian Cysts in Slaughtered Cows)

  • 손창호;강병규;최한선;강현구;임원호;박상국;오기석;서국현
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.138-144
    • /
    • 1999
  • To establish the differential diagnosis and treatment method in bovine ovarian cysts, specially ovarian cysts with corpus luteum, serum progesterone (P$_4$) concentration and ultrasonography for measuring the cystic wall thickness and diameter of cyst and corpus luteum were investigated from slaughtered cows with ovarian cysts. Ovarian cysts were classified 8 types by the number of cyst, cystic wall thickness and present of corpus luteum. Ovarian cysts with corpus luteum were 11 (13.6%) of 81 cows and ovarian cysts without corpus luteum were 70 (86.4%) cows. The incidence rates of 8 various types of ovarian cysts were as follows; 2Ba 33.3%, 2Aa 25.9% and 2Bb 14.8%, respectively. The incidence rates of ovarian cysts without corpus luteum were follicular cyst 59.2% and luteal cyst 27.2%. The cystic wall thickness were 2Ab 3.7 mm and 2Bb 3.5 mm, and the serum P4 concentrations were above 2.0 ng/ml in 1Aa, 1Ab, 1Ba, 2Ab and 2Bb, respectively. In ovarian cysts with corpus luteum, the correlation coefficients between corpus luteum area and serum P$_4$ concentration were 0.45. In ovarian cysts without corpus luteum, there was significantly positive correlations between cystic wall thickness and serum P$_4$ concentration ($r^2$= 0.54, p<0.01). These results indicate that PGF$_2$$\alpha$ analogues can be choice for treatment of ovarian cysts with corpus luteum and above 3 mm the cystic wall thickness because serum P$_4$ concentrations were above 2.0 ng/ml in ovarian cysts with corpus luteum and thickened cystic wall. In conclusion, it is suggest that ultrasonography is useful diagnostic tool for diagnosis and selection of treatment remedy in cystic ovaries of bovine.

  • PDF

Effects of pile geometry on bearing capacity of open-ended piles driven into sands

  • Kumara, Janaka J.;Kurashina, Takashi;Kikuchi, Yoshiaki
    • Geomechanics and Engineering
    • /
    • 제11권3호
    • /
    • pp.385-400
    • /
    • 2016
  • Bearing capacity of open-ended piles depends largely on inner frictional resistance, which is influenced by the degree of soil plugging. While a fully-plugged open-ended pile produces a bearing capacity similar to a closed-ended pile, fully coring (or unplugged) pile produces a much smaller bearing capacity. In general, open-ended piles are driven under partially-plugged mode. The formation of soil plug may depend on many factors, including wall thickness at the pile tip (or inner pile diameter), sleeve height of the thickened wall at the pile tip and relative density. In this paper, we studied the effects of wall thickness at the pile base and sleeve height of the thickened wall at the pile tip on bearing capacity using laboratory model tests. The tests were conducted on a medium dense sandy ground. The model piles with different tip thicknesses and sleeve heights of thickened wall at the pile tip were tested. The results were also discussed using the incremental filling ratio and plug length ratio, which are generally used to describe the degree of soil plugging. The results showed that the bearing capacity increases with tip thickness. The bearing capacity of piles of smaller sleeve length (e.g., ${\leq}1D$; D is pile outer diameter) was found to be dependent on the sleeve length, while it is independent on the sleeve length of greater than a 1D length. We also found that the soil plug height is dependent on wall thickness at the pile base. The results on the incremental filling ratio revealed that the thinner walled piles produce higher degree of soil plugging at greater penetration depths. The results also revealed that the soil plug height is dependent on sleeve length of up to 2D length and independent beyond a 2D length. The piles of a smaller sleeve length (e.g., ${\leq}1D$) produce higher degree of soil plugging at shallow penetration depths while the piles of a larger sleeve length (e.g., ${\geq}2D$) produce higher degree of soil plugging at greater penetration depths.

도축우 유래 난소낭종의 감별진단 및 치료제 선택 (Differential diagnosis of ovarian cysts and selection of therapeutic drugs in slaughtered cows)

  • 박상국;최동식;박장일;정대영
    • 한국동물위생학회지
    • /
    • 제23권2호
    • /
    • pp.125-132
    • /
    • 2000
  • To establish the differential diagnosis and treatment method in bovine ovarian cysts, specially ovarian cysts with corpus luteum, serum progesterone ($P_4$) concentration and ultrasonography for measuring the cystic wall thickness and diameter of cyst and corpus luteum were investigated from slaughtered cows with ovarian cysts. Ovarian cysts were classified 8 types by the number of cyst, cystic wall thickness and present of corpus luteum. Ovarian cysts with corpus luteum were 11 (13.6%) of 81 cows and ovarian cysts without corpus luteum were 70 (86.4%) cows. The incidence rates of 8 various types of ovarian cysts were as follows; 2Ba 33.3%, 2Aa 25.9% and 2Bb 14.8%, respectively The Incidence rates of ovarian cysts without corpus luteum were follicular cyst 59.2% and luteal cyst 27.2%. The cystic wall thickness were 2Ab 3.7mm and 2Bb 3.5mm, and the serum P4 concentrations were above 2.0 ng/$m\ell$ in IAa, tAb, IBa, 2Ab and 2Bb, respectively In ovarian cysts with corpus luteum, the correlation coefficients between corpus luteum area and serum $P_4$ concentration were 0.45. In ovarian cysts without corpus luteum, there was significantly positive correlations between cystic wall thickness and serum $P_4$ concentration($r^2$ = 0.54, p<0.01). These results indicate that $PGF_2$$\alpha$ analogues can be choice for treatment of ovarian cysts with corpus luteum and above 3mm the cystic wall thickness because serum $P_4$ concentrations were above 2.0 ng/$m\ell$ in ovarian cysts with corpus luteum and thickened cystic wall. In conclusion, it Is suggested that ultrasonography is useful diagnostic tool for diagnosis and selection of treatment remedy in cystic ovaries of bovine.

  • PDF

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제17권4호
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.