• 제목/요약/키워드: Wall imaging

검색결과 336건 처리시간 0.022초

Arterial Wall Imaging in Angiographically Occult Spontaneous Subarachnoid Hemorrhage : New Insight into the Usual Suspect

  • Yoon, Wonki;Kim, Jang Hun;Roh, Haewon;Kwon, Taek-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권2호
    • /
    • pp.245-254
    • /
    • 2022
  • Objective : The etiology of angiographically occult spontaneous subarachnoid hemorrhage (AOsSAH) is unclear. Three-dimensional (3D) high-resolution vessel wall magnetic resonance imaging (HVM) might be useful in detecting the hidden arterial wall angiopathy in patients with AOsSAH. We aimed to demonstrate the feasibility of HVM for detecting the arterial cause of AOsSAH. Methods : Patients, who were diagnosed with AOsSAH in the first evaluations and underwent HVM, were enrolled. Their clinical and radiologic data were retrospectively reviewed. Especially, focal enhancement of arterial wall on HVM and repetitive catheterized angiograms were precisely compared. Results : Among 251 patients with spontaneous SAH, 22 patients were diagnosed with AOsSAH in the first evaluations (8.76%). After excluding three patients who did not undergo 3D-HVM, 19 patients were enrolled and classified as convexal (n=2) or perimesencephalic (n=4), and diffuse (n=13) groups. In convexal and perimesencephalic groups, no focal enhancement on HVM and no positive findings on repetitive angiography were noted. In diffuse group, 10 patients showed focal enhancement of arterial wall on HVM (10/13, 76.9%). Repeated angiography with 3D reconstruction revealed four patients of angiographically positive causative arteriopathy and possible lesion in one case in the concordant location of intramural enhancement on 3D-HVM (5/10, 50%). Three of them were treated with endovascular stent insertion. All patients, except one, recovered with good clinical outcome (3-month modified Rankin score, 0 and 1). Conclusion : 3D-HVM was useful in detecting hidden true arteriopathy in AOsSAH. It may provide new insights into the etiologic investigation of AOsSAH by proving information about the arterial wall status.

A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls

  • No, Sang Tae
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.147-154
    • /
    • 2014
  • The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권1호
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Detection of Perivalvular Abscess with Late Gadolinium-Enhanced MR Imaging in a Patient with Infective Endocarditis

  • Ryu, Seong-Yoon;Kim, Hae Jin;Kim, Sung Mok;Park, Sung-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권1호
    • /
    • pp.75-79
    • /
    • 2016
  • We report a case of perivalvular abscess in a 66-year-old man with infective endocarditis, diagnosed by late gadolinium-enhanced (LGE) cardiovascular magnetic resonance (CMR) imaging. No clinical features suspicious of infective endocarditis were noted, however, transthoracic echocardiography revealed non-specific echogenic focal wall thickening at mitral-aortic intervalvular fibrosa. Perivalvular abscess in the aortic valve was demonstrated as focal wall thickening between the anterior mitral leaflet and the non-coronary cusp of the aortic valve with peripheral enhancement and central low signal intensity on LGE CMR imaging. Other features suggestive of infective endocarditis, such as neither vegetation nor valvular perforation were present. The perivalvular abscess did not grow after intensive intravenous antibiotics therapy, and the patient was discharged without surgical treatment. CMR with LGE provided an early accurate diagnosis of perivalvular abscess. The diagnosis of perivalvular abscess using LGE CMR imaging was not previously reported in Korea.

In-camera VFX implementation study using short-throw projector (focused on low-cost solution)

  • Li, Penghui;Kim, Ki-Hong;Lee, David-Junesok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.10-16
    • /
    • 2022
  • As an important part of virtual production, In-camera VFX is the process of shooting actual objects and virtual three-dimensional backgrounds in real-time through computer graphics technology and display technology, and obtaining the final film. In the In-camera VFX process, there are currently only two types of medium used to undertake background imaging, LED wall and chroma key screen. Among them, the In-camera VFX based on LED wall realizes background imaging through LED display technology. Although the imaging quality is guaranteed, the high cost of LED wall increases the cost of virtual production. The In-camera VFX based on chroma key screen, the background imaging is realized by real-time keying technology. Although the price is low, due to the limitation of real-time keying technology and lighting conditions, the usability of the final picture is not high. The short-throw projection technology can compress the projection distance to within 1 meter and get a relatively large picture, which solves the problem of traditional projection technology that must leaving a certain space between screen and the projector, and its price is relatively cheap compared to the LED wall. Therefore, in the In-camera VFX process, short-throw projection technology can be tried to project backgrounds. This paper will analyze the principle of short-throw projection technology and the existing In-camera VFX solutions, and through the comparison experiments, propose a low-cost solution that uses short-throw projectors to project virtual backgrounds and realize the In-camera VFX process.

A Dual-Band Through-the-Wall Imaging Radar Receiver Using a Reconfigurable High-Pass Filter

  • Kim, Duksoo;Kim, Byungjoon;Nam, Sangwook
    • Journal of electromagnetic engineering and science
    • /
    • 제16권3호
    • /
    • pp.164-168
    • /
    • 2016
  • A dual-band through-the-wall imaging radar receiver for a frequency-modulated continuous-wave radar system was designed and fabricated. The operating frequency bands of the receiver are S-band (2-4 GHz) and X-band (8-12 GHz). If the target is behind a wall, wall-reflected waves are rejected by a reconfigurable $G_m-C$ high-pass filter. The filter is designed using a high-order admittance synthesis method, and consists of transconductor circuits and capacitors. The cutoff frequency of the filter can be tuned by changing the reference current. The receiver system is fabricated on a printed circuit board using commercial devices. Measurements show 44.3 dB gain and 3.7 dB noise figure for the S-band input, and 58 dB gain and 3.02 dB noise figure for the X-band input. The cutoff frequency of the filter can be tuned from 0.7 MHz to 2.4 MHz.

Multipath Ghosts in Through-the-Wall Radar Imaging: Challenges and Solutions

  • Abdalla, Abdi T.;Alkhodary, Mohammad T.;Muqaibel, Ali H.
    • ETRI Journal
    • /
    • 제40권3호
    • /
    • pp.376-388
    • /
    • 2018
  • In through-the-wall radar imaging (TWRI), the presence of front and side walls causes multipath propagation, which creates fake targets called multipath ghosts. They populate the scene and reduce the probability of correct target detection, classification, and localization. In modern TWRI, specular multipath exploitation has received considerable attention for reducing the effects of multipath ghosts. However, this exploitation is challenged by the requirements of the reflecting geometry, which is not always available. Currently, the demand for a high radar image resolution dictates the use of a large aperture and wide bandwidth. This results in a large amount of data. To tackle this problem, compressive sensing (CS) is applied to TWRI. With CS, only a fraction of the data are used to produce a high-quality image, provided that the scene is sparse. However, owing to multipath ghosts, the scene sparsity is highly deteriorated; hence, the performance of the CS algorithms is compromised. This paper presents and discusses the adverse effects of multipath ghosts in TWRI. It describes the physical formation of ghosts, their challenges, and existing suppression techniques.

선형 트랜스듀서를 이용한 혈관 변형률 영상법 (Blood Vessel Strain Imaging Using Linear Array Transducer)

  • 안동기;정목근
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.880-890
    • /
    • 2010
  • 뇌졸중 등의 혈관 질병을 진단하기 위해서 혈관 내 초음파(Intravascular Ultrasound:IVUS)영상 기법이 사용되고 있다. 최근에는 혈관 내벽에 붙은 혈전을 탄성 영상법을 이용하여 진단하는 방법들이 연구되고 있다. 그러나 혈관 내 초음파는 혈관 내에 트랜스듀서를 삽입하여야 하므로 진단 방법에 위험성이 있다. 본 논문은 선형 트랜스듀서를 이용하여 혈관 외부에서 데이터를 획득하여 혈관 내벽에 붙은 혈전의 변형률 영상을 얻었다. 혈관 벽의 움직임을 정확하게 측정하기 위하여, 혈관 벽과 수직이 되도록 주사선의 방향을 조향하면서 초음파 데이터를 획득하였다. 초음파 데이터는 기저대역의 복소수 신호로 복조한 뒤 자기상관(autocorrelation)을 이용하여 혈관 벽의 움직임을 계산하여 변형률 영상을 얻었다. 제안한 방법을 플라스틱 기반의 혈관 모사 팬텀을 제작하여 검증하였다. 혈관 모사 팬텀은 혈관에 해당하는 직경 6mm의 실린더 공간에 물을 채우고 벽을 따라 2mm 두께의 부드러운 혈전을 혈관 벽의 내부에 배치하였다. RF 데이터는 상용 초음파 진단기에서 7.5MHz 선형 트랜스듀서를 사용하여 -40도부터 40도까지 1도 간격으로 조향시킨 81개의 스캔라인 데이터를 얻었다. 실험 결과 단단한 배경 팬텀에 인접한 혈전 영역이 더 무른 것으로 관찰되었다. 제안한 방법의 탄성 영상법이 비록 주사선이 혈관 벽에 수직으로 입사하는 영역으로 제한되지만 혈관 변형률 영상법의 유용함을 실험으로 입증하였다.

A Study on the Effectiveness of Heat Infrared Imaging Method for Monitoring the Physical Condition of the Mortar Walls

  • Yoshioka Ryouhei;Tachiiri Kaoru;Asari Kimihiro;Gotoh Keinosuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.545-548
    • /
    • 2004
  • In Japan for protecting the slides of steep sloped areas covering the face of slopes by sprayed mortar became popular since 1970s. But, these mortar walls are getting older now. In this background, this study aims to find ways to develop a diagnostic technique of these faces of slope without physically contacting or destroying them. In doing so, we have used heat infrared imaging processing method and developed a simulation model to predict the weak portion of the wall. The results revealed that, by following the model vacuum of mortar wall can be detected having thickness up to 15cm.

  • PDF

Computed Tomographic Findings of Adenocarcinoma of the Esophagocardia Region in a Pekingese Dog with Brachycephalic Syndrome

  • Cho, Yugyeong;Nam, Yunjeong;Chae, Sooyoung;Jeong, Youjin;Song, Youngmok;Kim, Soyoung;Choi, Hojung;Lee, Youngwon
    • 한국임상수의학회지
    • /
    • 제34권4호
    • /
    • pp.295-298
    • /
    • 2017
  • A 6-year-old female Pekingese dog, weighing 3.85 kg was presented with regurgitation, ptyalism, weight loss and anorexia. The dog was cachexic and severely dehydrated. Physical examination of the dog confirmed upper respiratory noise, which was classified as a stridor most apparent on inspiration, respiratory effort with stenotic nares. Upper respiratory signs were thought to be caused by brachycephalic syndrome. On the lateral thoracic radiograph, the caudal one third of the esophagus was visible as a soft tissue band. CT revealed oval-shaped, soft tissue attenuating mass in size of $2.3{\times}1.0{\times}1.1cm$ arising from caudal one third of the esophagus. The mass was protruding from esophageal wall to lumen and irregular margined with heterogenous contrast enhancement. The wall of cardia and fundus was focally thickened. Gastric lymph node was enlarged with contrast enhancing. On histopathologic examination, esophageal mass was confirmed as papillary adenocarcinoma, and the gastric sample showed the same result. In human, adenocarcinoma commonly occur in esophagus and cardia, but it has not been commonly reported in veterinary medicine. This report described computed tomographic features of adenocarcinoma of the esophagocardia region in a Pekingese dog with brachycephalic syndrome.