• 제목/요약/키워드: Wall boundary condition

검색결과 271건 처리시간 0.024초

다중완화시간 격자 볼츠만기법을 이용한 다양한 종횡비의 리드드리븐 공동유동 수치해석연구 (SIMULATION OF LID DRIVEN CAVITY FLOW WITH DIFFERENT ASPECT RATIOS BY MULTI-RELAXATION-TIME LATTICE BOLTZMANN METHOD)

  • 황팅팅;송주헌;임희창
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.42-51
    • /
    • 2020
  • This study performs a numerical simulation of lid driven rectangular cavity flow with different aspect ratios of k = 0.5 to 4 under Reynolds 100, 1,000, 10,000 by using multi-relaxation time (MRT) Lattice Boltzmann Method (LBM). In order to achieve better convergence, well-posed boundary conditions in the domain should be defined such as no-slip condition on side and bottom solid wall surfaces and uniform horizontal velocity on the top of the cavity. This study focuses on the flow inside different shape of rectangular cavity with the aim to observe the effect of the Reynolds number and aspect ratio on the flow characteristics and primary/secondary vortex formation. In order to validate the study, the results have been compared with existing works. The result shows that the Reynolds number and the aspect ratio both has substantial effects on the flow inside the lid-driven rectangular cavity.

경의선 숲길공원의 범죄예방 환경디자인 개선점 연구 - 창전동 구간을 중심으로 - (A Study on Improvement of Crime Prevention Environment Design in Gyeongui Line Forest Park - In Case of Changjeon-dong section -)

  • 김연경;유다은
    • 대한건축학회논문집:계획계
    • /
    • 제36권1호
    • /
    • pp.113-124
    • /
    • 2020
  • The purpose of this study is to suggest an improvement for the CPTED(Crime Prevention Through Environmental Design) guidelines for the urban linear park. We analysed the Changjeon-dong section of Gyeongui Line Forest Park into 12 sub-areas and evaluated CPTED design applied on the park based on analysis framework derived from 15 precedent studies by conducting on-site observations. Both surveys and in-depth interviews on users of the park were conducted and the results of analysis on the evaluation from users and the on-site observation were compared. We found that the lighting condition and the height of wall and trees at the park boundaries are very important to insure natural surveillance since the adjacent areas are easy to be hidden from passers-by and subject to invasion and threat of crime while protecting the privacy of residents on the boundary. There should be improvement on management facilities and crime prevention facilities for more safe and convenient use of the linear park and the adjacent commercial use during nighttime also need to be managed for conflicts between various type of users.

Rayleigh-Ritz 방법에 의한 흡음재가 부착된 직방형 소음기의 전달 손실 예측 (Prediction of the Transmission Loss of Rectangular Lined Plenum Chamber by the Rayleigh-Ritz Method)

  • 김회전;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.869-872
    • /
    • 2005
  • The purpose of this study is on the prediction of the acoustic performance of the lined rectangular plenum chamber which can be used in the HVAC systems. The lined plenum chamber is modeled as a piston driven rectangular tube without mean flow and the acoustic pressure in the lined chamber is obtained by superposing the three dimensional pressure due to each of uniformly and harmonically fluctuating pistons. The arbitrary locations of inlet/outlet ports as well as the acoustic higher order modes generated at the area discontinuities of the port chamber interfaces are taken into consideration. The four-pole parameters can be derived by imposing the proper boundary conditions on each inlet and outlet ports. The lining material on the internal wall is assumed to be a bulk-reacting model. A single weak variation statement which satisfies the fluctuating rigid piston condition and the pressure and displacement continuity condition at the interface between the lining material and the airway was developed. The set of cosine functions were used as the admissible function when applying the Rayleigh-Ritz method. Computed results are compared with those predicted by using the locally-reacting lining material and experimental results, respectively. There are a good agreement shown between the results by the Rayleigh-Ritz method and the experiment results. The derived transfer matrices can be easily combined with other four-pole parameters of different types of mufflers for the calculation of the whole system performance.

  • PDF

초음속풍동 실험에서 사용하는 압력측정 Probe에 대한 고찰 II (The Consideration in Terms of Pressure Probe Used in Experiments of Supersonic Wind Tunne II)

  • 이재호;이영빈;최중근;최종호;윤현걸;김규홍
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.359-363
    • /
    • 2011
  • 초음속풍동에서 사용하는 압력 probe의 형상에 따른 압력특성에 대하여 분석하였다. 초음속풍동의 성능을 평가할 때 시험부의 벽면정압력과 전방안정실의 전압력을 측정하고 그 비로 마하수를 계산한다. 또한 쉴리렌 가시화를 통하여 유질의 상태를 확인한다. 그러나 매우 빠른 초음속 영역에서는 경계층의 영향을 무시할 수 없기 때문에 시험부의 압력을 측정하는데 한계가 있다. 따라서 시험부의 유질이 균일한지 확인을 위해 다양한 위치에서 압력을 측정하기 위한 probe가 필요하다. 본 논문에서 몇 가지 피토형상에 대해서 실험을 진행했고, 그 결과를 비교 분석했다.

  • PDF

Motion and sloshing analysis for new concept of offshore storage unit

  • Ha, Mun-Keun;Kim, Mun-Sung;Paik, Bu-Keun;Park, Chung-Hum
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.189-195
    • /
    • 2000
  • New concept of LNG-FPSO ship with moonpool and bilge step in bottom is considered and investigated in the point of motion reduction and sloshing phenomena of the cargo and operation tanks. The cargo capacity of the ship of which principle dimensions is L x B x D x t(design) =270.0 x 51.0 x 32.32 x 13.7(m) 16K at 98% loading condition. The two moonpools and rectangular step at bilge part are setted up specially for getting the effect of motion decrease. For the motion analysis, linearized three dimensional diffraction theory with the simplified boundary conditions is used. The six-degree of freedom coupled motion responses are calculated for the LNG-FPSO ship. Viscous effects on the roll motion responses of a vessel are taken into account in this calculation program using an empirical formula suggested by Ikeda, Himeno and Tanaka is used. The case study for the moonpool size had been carried out by theoretical estimation and experimental method. For the optimization of the moonpool size and effect of the step, 9 cases of its size and with and without step are considered. From the results of calculation and experiment, it can be concluded that this designed LNG-FPSO ship have possibility to carry out her missions in the rough sea as for the owner's demand waves condition. The motion responses, especially roll motion, for the designed LNG-FPSO ship are much lower than those of another drillship and shuttle tanker and limit criterions are satisfied. For the check of the cargo tank and operation tank sizes we have performed sloshing analysis in the irregular waves which focuses on the pressure distribution on the tank wall and the time history of pressure and free surface for No.2 and No5. tanks of LNG-FPSO with chamfers. Finally we got the tank size which has no resonance and no impact pressure in all filling in the bow quartering and beam sea.

  • PDF

Motion and Sloshing Analysis for New Concept of Offshore Storage Unit

  • Ha, Mun-Keun;Kim, Mun-Sung;Paik, Bu-Keun;Park, Chung-Hum
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • 제5권1호
    • /
    • pp.22-28
    • /
    • 2002
  • A New concept for the LNG-FPSO ship, with moonpool and bilge step in bottom, is proposed. This concept is investigated with regard to motion reduction and sloshing phenomena of the cargo and operation tanks. The principal dimensions of the ship are $L\timesb B\times D\times t(design)=270.0\times51.0\times32.32\times13.7(m)$, with a total cargo capacity of 161KT; a 98% loading condition is considered for this study. The moonpools and rectangular step at the bilge have been designed for the purpose of decreasing the motion within the tank. For the motion analysis, linearized three-dimensional diffraction theory, with the simplified boundary condition was used. The six-degree of freedom coupled motion responses were calculated for the LNG-FPSO ship. Viscous effects on the roll motion responses of a vessel were taken into account in this calculation program, using an empirical formula suggested by Himeno(1981). The case study for the moonpool size has been conducted using theoretical estimation and the experimental method. For the optimization of the moonpool size and effect of the bilge step, 9 cases of its size, both with and without bilge step, were involved in the study. no motion responses, especially roll motion, for the designed LNG-FPSO ships are much lower than those of other drill ships and shuttle tankers. The limit criterions are satisfied. To check the cargo tank and operation tank sizes, we performed a sloshing analysis in the irregular waves which focuses on the pressure distribution on the tank wall and the time history of pressure and free surface for No.2 and 5 tanks of LNG-FPSO with chamfers. Finally, optimum tank sire was estimated.

  • PDF

기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column)

  • 권영필;이병호
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.253-261
    • /
    • 1987
  • 본 논문에서는 이러한 점들을 보완하여 Fig.1에 도시한 Rijke 관에서 나선형 가열기에 의한 음향력의 발생량을 계산하고 기주진동을 일으키는데 필요한 가열량을 계산하고 기주진동을 일으키는데 필요한 가열량을 구하였다. 이론을 뒷받침하기 위 하여 실험을 하고 결과를 비교 검토하였다.

엔트로피 개념을 활용한 개수로 마찰속도 산정 (The Estimation of Friction Velocity in an Open Channel by the Entropy Concept)

  • 추태호;손희삼;윤관선;노현석;고현수
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1533-1540
    • /
    • 2015
  • 수공구조물 설계 또는 하상의 유동 특징을 나타내기 위해선 마찰속도 산정이 필수적이다. 하지만 기존의 개수로 내의 마찰속도 공식인 Log 방법이나 Power방법은 벽면 근처에서 경계층 조건 혹은 다양한 수리적 특성이 지속적으로 변화하기 때문에 마찰속도의 산정에 어려움이 있다. 따라서 본 연구에서는 매개변수를 최소화하고 오차를 줄일 수 있는 새로운 마찰속도 공식을 제안하였다. 제안한 공식에 대한 신뢰성과 정확성을 검증하기 위하여 엔트로피매개변수M을 각각의 수로마다 산정을 하여 Dr.Song이 산정한 3가지 방법(Clauser 방법, $\sqrt{gRI}$ 방법, 레이놀즈 응력법)으로 산정한 마찰속도와 비교하였다. 그 결과 가속부등류 조건의 경우 $R^2=0.9621$ 감속부등류 조건의 경우 $R^2=0.9274$ 등류흐름 조건의 경우 $R^2=0.8865$로 매우 높은 정확성으로 등류조건뿐만 아니라 부등류 조건에서도 거의 일치하였다.

에너지 축열보드 열해석을 위한 컴퓨터 수치해석 (Computer Simulation for the Thermal Analysis of the Energy Storage Board)

  • 강용혁;엄태인;곽희열
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.224-232
    • /
    • 1999
  • 캡슐형 잠열재를 이용한 열저장 시스템은 바닥 난방 및 건물 난방에서 매우 효과적인 시스템이다. 이러한 시스템 개발에 필수적인 요소가 열유동 매체가 순환하는 파이프 주변의 캡슐내 온도 분포와 열유동 매체의 유량 등이다. 그러므로 본 연구에서는 3차원 비정상 상태에서 Navier-Stokes 방정식, 난류모델을 비롯한 스칼라 보존 방정식을 적용하여 캡슐 블록의 온도 분포 및 파이프 내의 유동장 해석을 수행하였다. 또한 본 연구와 같이 계산 영역이 특별한 기하학적 현상을 형상(circle+square)인 문제 해결하는데 적용할 수 있는 새로운 격자 생성 기술(MBFGE/CCM)을 개발하였다. 격자계는 파이프에서 원형 격자를 이용하였고, 캡슐 블록에서 사각 격자를 이용하여 다중격자와 미세격자를 결합하여 사용하였다. 본 연구의 목적은 컴퓨터를 이용한 수치해석적 방법을 미세 캡슐을 이용한 축열보드에 적용하여 2종류의 열경계 상태에 대하여 속도와 온도분포를 계산하여 비교분석을 하는 것이다. 온도는 축열 보드의 한 쪽면은 대류면이고 다른 한쪽면은 단열면인 경우(Case 2)보다 양면 모두 단열인 경우(Case 1)일 때 더 높게 상승하였다. 온수 파이프 중심선인 Y=0 에 가까운 영역에서 Case 1과 Case 2사이에 축열 보드 내에서 온도 차이는 확연하게 나타났다. 향후 수치해석의 정확도를 높이고 축열 보드의 열전달 현상을 보다 정확히 계산하기 위해서는 위치 및 시간에 따른 정밀한 온도 측정값이 필요하고 특히 잠열재인 미세 캡슐이 상변화를 하므로 온도 변화에 따른 물질의 비열(C$_{p}$)과 열전달율(λ)을 고려한 방정식이 요구된다.

  • PDF

조사시험용 압력용기의 조립 및 시험 (The Assembly and Test of Pressure Vessel for Irradiation)

  • 박국남;이종민;윤영중;전형길;안성호;이기홍;김영기;케네디
    • 대한기계학회논문집A
    • /
    • 제33권2호
    • /
    • pp.179-184
    • /
    • 2009
  • The Fuel Test Loop(FTL) which is capable of an irradiation testing under a similar operating condition to those of PWR(Pressurized Water Reactor) and CANDU(CANadian Deuterium Uranium reactor) nuclear power plants has been developed and installed in HANARO, KAERI(Korea Atomic Energy Research Institute). It consists of In-Pile Section(IPS) and Out-of Pile System(OPS). The IPS, which is located inside the pool is divided into 3-parts; the in-pool pipes, the IVA(IPS Vessel Assembly) and the support structures. The test fuel is loaded inside a double wall, inner pressure vessel and outer pressure vessel, to keep the functionality of the reactor coolant pressure boundary. The IVA is manufactured by local company and the functional test and verification were done through pressure drop, vibration, hydraulic and leakage tests. The brazing technique for the instrument lines has been checked for its functionality and performance. An IVA has been manufactured by local technique and have finally tested under high temperature and high pressure. The IVA and piping did not experience leakage, as we have checked the piping, flanges, assembly parts. We have obtained good data during the three cycle test which includes a pressure test, pressure and temperature cycling, and constant temperature.