• 제목/요약/키워드: Wall Thickness Reduction

검색결과 131건 처리시간 0.027초

분말시스압연법에 의해 제조된 알루미늄 분말성형체의 조직 및 기계적 성질 (Microstructure and Mechanical Property of Aluminum Powder Compact by Powder-in Sheath Rolling Method)

  • 이성희
    • 한국분말재료학회지
    • /
    • 제9권3호
    • /
    • pp.153-160
    • /
    • 2002
  • A nitrogen gas atomized aluminum powder was consolidated by powder-in sheath rolling method. A pure aluminum tube with outer diameter of 12 mm and wall thickness of 1mm was used as a sheath. The aluminum tube filled with the aluminum powder, first, was cold-rolled to the thickness of 6mm for performing, and then consolidated by the cold rolling and/or subsequent hot rolling at 360, 460 and $560^{\circ}C$. The aluminum powder compact fabricated by the sheath rolling showed high relative density more than 0.96 at any rolling conditions. The 0.2% proof stress increased with increasing hot rolling reduction and hot rolling temperature. Tensile strength was hardly affected by change in the hot rolling reduction, whereas it decreased with increasing hot rolling temperature. The powder compact showed the large elongation when cold rolling or hot rolling reduction was large. It was found that the sheath rolling was an effective method for consolidation of aluminum powder.

NUMERICAL ANALYSIS ON THE NATURAL CONVECTION IN A LONG HORIZONTAL PIPE WITH THERMAL STRATIFICATION

  • Ahn, Jang-Sun;Park, Byeong-Ho;Kim, Seoug-Beom;Kim, Eun-Kee;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.95-101
    • /
    • 1996
  • In this paper, the steady 2-dimensional model for a long horizontal line with different end temperatures undergoing natural convection at very high Rayleigh number is proposed to numerically investigate the heat transfer and flow characteristics. The dimensionless governing equations are solved by using SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm which is developed using control volumes and staggered grids. The numerical results are verified by comparison with the operating PWR test data. The analysis focuses on the effects of variation of the heat transfer rates at the pipe surface, the thermal conductivities of the pipe material and the thickness of the pipe wall on the thermal stratification. The results show that the heat transfer rate at the pipe surface is the controlling parameter. A significant reduction and disappearance of thermal stratification phenomenon is observed at the Biot number of 5.0$\times$10$^{-2}$. The results also show that the increment of the thermal conductivity and thickness of the wall weakens the thermal stratification and somewhat reduces azimuthal temperature gradient in the pipe wall. Those effects are however minor, when compared with those due to the variation of the heat transfer rates at the surface of the pipe wall.

  • PDF

Evaluation of Thermal Stratification Effect in a Long Horizontal Pipeline with Turbulent Natural Convection

  • Park, Man-Heung;Ahn, Jang-Sun;Nam, Seung-Deog
    • Nuclear Engineering and Technology
    • /
    • 제30권6호
    • /
    • pp.581-591
    • /
    • 1998
  • Numerical analysis was peformed for the two-dimensional turbulent natural convection for a long horizontal line with different end temperatures. The turbulent model has been applied a standard k-$\varepsilon$ two equation model of turbulence similar to that the proposed by the Launder and Spalding. The dimensionless governing equations are solved by using SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm which is developed using control volumes and staggered grids. The numerical results are verified by comparison with the operating PWR test data. The analysis focuses on the effects of variation of the heat transfer rates at the pipe surface, the thermal conductivities of the pipe material and the thickness of the pipe wall on the thermal stratification. The results show that the heat transfer rate at the pipe surface is the controlling parameter for mitigating of thermal stratification in the long horizontal pipe. A significant reduction and disappearance of the thermal stratification phenomenon is observed at the Biot number of 4.82$\times$10$^{-1}$ . The results also show that the increment of the thermal conductivity and thickness of the wall weakens a little the thermal stratification and somewhat reduces temperature gradient of y-direction in the pipe wall. These effects are however minor, when compared with those due to the variation of the heat transfer rates at the surface of the pipe wall.

  • PDF

주거용 건물의 난방 에너지 자립을 위한 기초 연구 (A Fundamental Study On the Self-Sufficient Heating Energy for Residential Building)

  • 손선우;백남춘;서승직
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.255-258
    • /
    • 2009
  • Leading developed countries have studied energy self-sufficient houses such as zero or low energy buildings to reduce energy consumption for buildings since the early 1990s. Moreover, some developed countries have actually constructed self-sufficient houses and operated them for demonstration, expanding use of such houses. Korea has also established Zero Energy Solar House(ZeSH) and studied energy independence. Therefore, this study analyzed research result regarding ZeSH, self-sufficient energy house hold of Korea, found out technologies used for heating energy independence, used building interpretation program(ESP_r) to evaluate performance of each factors and analyzed energy reduction quantitatively. Results from the research are as follows: Reduction rate of actual detached house's heating load was also analyzed quantitatively depending on application of each technology. When each factor was applied step-by-step, annual reduction rate of heating load depending on increase in insulation thickness reached 6.6~22.2 %. Annual reduction rate of heating load depending on increase insulation thickness, and change in window heating performance and area ratio reached 31.5 %. Annual reduction rate of heating load through high-sealing and high-insulation depending on change in leakage rate reached 40.0~88.9 %. Annual reduction of heating load, when Mass Wall and attached sun space was applied were applied reached 28.5~39.2 %, respectively.

  • PDF

광량 및 TiO2 나노튜브 길이별 광활성 연구: Cr(VI)환원 및 수소제조 (Effect of TiO2 Nanotube Length on Photocatalytic Activity with Different Light Intensities: Cr(VI) Reduction and Hydrogen Production)

  • 주현규;심은정;이재민;윤재경
    • 한국수소및신에너지학회논문집
    • /
    • 제22권4호
    • /
    • pp.432-442
    • /
    • 2011
  • Anodized tubular $TiO_2$ electrodes (ATTEs) with three noticeably different lengths are prepared to determine their optimum length for the photo-driven activity in the reaction of Cr(VI) reduction and hydrogen evolution. The ATTEs with ethylene glycol have longer $TiO_2$ tubes (7-15.6 ${\mu}m$) than those with hydrfluoric acid (0.6-0.8 ${\mu}m$). These samples, which differ only in the length of the tubes, with a wall thickness of ca. 20 nm, consist mainly of an anatase crystalline phase after heat treatment at $650^{\circ}C$, since the anatase crystallites at the tube walls do not undergo transformation into rutile phase, due to the constraints imposed by the wall thickness. Among them, the medium size (ca. 8 ${\mu}m$) tubes provide the optimum conditions, irrespective of the light intensity, which is explained in terms of the correlation between the amount of photons and the adsorbed electron acceptors and their location. Photocatalytic Cr(VI) reduction leads to ca. 60% reduction of Cr(VI) even under 1 sun irradiation with the medium-sized anodized $TiO_2$ tubes, but only ca. 20% with the short- and long-sized tubes. For hydrogen evolution, tubes longer than 8 ${\mu}m$ do not exhibit better performance with any light intensity.

고층건물의 횡변위에 대한 커플링보의 효과 (The Effects of Coupling Beam on Lateral Drift of High-rise Buildings)

  • 김진상
    • 한국산학기술학회논문지
    • /
    • 제12권12호
    • /
    • pp.5931-5937
    • /
    • 2011
  • 본 연구에서는 고층건물의 횡변위 구조형식으로 널리 사용되는 전단벽-커플링보 구조시스템에서 커플링보가 건물의 횡변위에 미치는 영향을 분석하였다. 기본해석모델로는 벽체와 기둥의 콘크리트 강도와 벽체두께에 따라 6가지를 선택하였다. 이 모델을 기본으로 하여 커플링보의 강성을 변화시켜 해석을 수행하였다. 해석프로그램으로는 MIDAS GEN을 이용하였다. 해석결과로부터 각각의 해석모델들의 최상층 횡변위와 CEN EC 3/1에서 규정하고 있는 횡변위 허용 범위(H/400~H/500)를 비교하고 분석함으로써 커플링보의 횡변위 제어능력을 평가 하였다. x방향 횡변위는 허용 횡변위(H/500)의 68%~87%정도로서 벽체두께 100mm 증가에 따라 약 8%~10%의 횡변위 감소가 있음을 확인하였고, 콘크리트 강도가 5Mpa 증가함에 따라 횡변위는 약 4%의 감소 효과가 있는 것으로 분석되었으며, 두 경우 모두 x, y방향에 대하여 유사한 결과가 나타난 것으로 확인되었다. 커플링보 강성저하에 따른 횡변위 비율은 허용변위 기준인 H/500를 기준하여 분석결과 최초 강성 20% 저하 시 횡변위는 3%정도의 변위 증가가 나타났으며, 추가 20% 저하 시 5%~8%의 변위가 발생되었다.

고주파 벤딩을 통한 케이블 파이프의 변형에 관한 연구 (A Study on the Deformation of Cable Pipes via Induction Bending)

  • 주이환;진진;문성민;류성기
    • 한국기계가공학회지
    • /
    • 제19권4호
    • /
    • pp.79-84
    • /
    • 2020
  • Induction bending via high-frequency heating is widely used for manufacturing pipe and section steel bends. It allows productivity improvement, unit cost reduction, delivery time compliance, and good mechanical properties. The recent increase in high-end vessels and offshore plants has raised the demand for high-frequency bending, which should improve the product quality and reduce the costs by simplifying the fabrication process; therefore, the characteristics and performance of this technique must be studied and proper design technology is required. During hot pipe bending via induction heating, the outward wall thickness of the pipe is thinned due to tensile stress and this thickness reduction cannot exceed 12.5%. This study focused on pipe bends with a bending curvature of 5D and their optimization design; in particular, the conditions that can both improve the productivity of the high-frequency bending process and keep the maximum thickness reduction below 12.5% were determined.

흉곽(胸廓)의 전자선(電子線) 조사시(照射時) 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on Electron Beam Dosimetry for Chest Wall Irradiation)

  • 강위생;고경환;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.41-45
    • /
    • 1983
  • To obtain 7 MeV electron beam which is suitable for treatment of the chest wall after radical of modified radical mastectomy, the authors reduced the energy of electron beam by means by Lucite plate inserted in the beam. To determine the proper thickness of the Lucite plate necessary to reduce the energy of 9 MeV electron beam to 6 MeV, dosimetry was made by using a parallel plate ionization chamber in polystyrene phantom. Separation between two adjacent fields, 7 MeV for chest wall and 12 MeV for internal mammary region, was studied by means of film dosimetry in both polytyrene phantom and Humanoid phantom. The results were as follows. 1. The average energy of 9 MeV electron beam transmitted through the Lucite plate was reduced. Reduction was proportional to the thickness of the Lucite plate in the rate of 1.7 MeV/cm. 2. The proper thickness of the Lucite plate necessary to obtain 6 MeV electron beam from 9 MeV was 1.2 cm. 3. 7 MeV electron beam, 80% dose at 2cm depth, is adequate for treatment of the chest wall. 4. Proper separation between two adjacent electron fields, 7 MeV and 12 MeV, was 5mm on both flat surface and sloping surface to produce uniform dose distribution.

  • PDF

전자기력을 이용한 난류경계층 제어 (Turbulent boundary layer control via electro-magnetic forces)

  • 이중호;성형진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.166-171
    • /
    • 2004
  • Direct numerical simulations are peformed to investigate the physics of a spatially developing turbulent boundary layer flow suddenly subjected to spanwise oscillating electro-magnetic forces in the near-wall region. The Reynolds number based on the inlet momentum thickness and free-stream velocity is $Re_\theta=300$. A fully-implicit fractional step method is employed to simulate the flow. The mean flow properties and the Reynolds stresses are obtained to analyze the near-wall turbulent structure. It is found that skin-friction and turbulent kinetic energy can be reduced by the electro-magnetic forces. Instantaneous flow visualization techniques are used to observe the response of streamwise vortices to spanwise oscillating forces. The near-wall vortical structures are clearly affected by spanwise oscillating electro-magnetic forces.

  • PDF

코발트계 극박형 비정질합금의 형성과 자기적 성질 (Fabrication and Magnetic Properties of Ultrathin Co-based Amorphous Alloy)

  • 노태환
    • 한국자기학회지
    • /
    • 제8권5호
    • /
    • pp.255-260
    • /
    • 1998
  • 두께 10$\mu\textrm{m}$ 이하의 코발트계 극박형 비정질합금의 진공중 용탕급냉방법에 의한 제조조건과 자기적 특성에 대해 연구되었다. 구리 냉각롤의 회전 선속도를 55 m/s로 하였을 때, 0.05 kgf/cm2 이하의 용탕분사압 조건에서 극박형 리본이 얻어졌다. 합금 두께는 용탕분사 가스압력의 감소에 비례하여 직선적으로 감소하였으며, 이와 동시에 폭의 감소도 함께 일어났다. 이는 극박형 합금을 만들기 위해 용탕분사압을 극단적으로 감소시키면 노즐구의 양단부에서 용융금속과 노즐 사이의 마찰효과가 크게 나타나 유효분사압이 현저히 감소하는 데에 기인하는 것으로 해석되었다. 저주파(1 kHz) 실효투자율은 대략 2차 함수의 관계로 리본 두께의 감소에 따라 저하되었다. 반면 보자력은 두께의 감소에 반비례하여 증가하였는데, 이들 현상은 거의 전적으로 표면효과의 증대에 의한 자벽이동의 억제에 그 원인이 있는 것으로 판단되었다. 그러나 고주파(1 MHz) 실효투자율은 두께의 감소에 따라 증가하였는바 이는 와전류 발생이 억제되어 자기장 방향으로의 자화회전이 보다 용이해지기 때문으로 생각되었으며, 결과적으로 극박화에 의해 MHz 대역에서 우수한 저손실 성질을 나타내는 자심 특성의 실현이 가능하였다.

  • PDF