• Title/Summary/Keyword: Wall Loss

Search Result 786, Processing Time 0.024 seconds

LOCA Analysis and Development of a Simple Computer Code for Refill-Phase Analysis (냉각재 상실사고 분석 및 재충진 단계해석용 전산코드 개발)

  • Ree, Hee-Do;Park, Goon-Cherl;Kim, Hyo-Jung;Kim, Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.200-208
    • /
    • 1986
  • The loss of coolant accident based on a double-ended cold leg break is analyzed with the discharge coefficient (Ca) of 0.4. This analysis covers the whole transient period from the start of depressurization to the complete refilling of the core by using RELAP4/MOD6-EM and RELAP4/ MOD6-HOT CHANNEL for the system thermal-hydraulics and the fuel performance during the blowdown phase respectively, and RELAP4/MOD6-FLOOD and TOODEE2 during the reflood phase. A simple analytical method has been developed to account for the lower plenum filling by approximating steam-water countercurrent flows and superheated wall effects at the downcomer during the refill period. Based on the informations. at the time of EOB (end-of-bypass), the refill duration time and the initial reflooding temperature were estimated and compared with the results from the RELAP4/MOD6, resulting in a good agreement. In addition, some parametric studies on the EOB were performed. The form loss coefficient between upper head and upper downcomer was found to be sensitive to the occurrence of the spurious EOB. Appropriate form loss coefficients should be taken into account to avoid the flow oscillations at the downcomer. The analyses with the six and three volume core nodalizations, respectively, show much similar trends in the system thermal-hydraulic performance, but the former case is recommended to obtain good results.

  • PDF

Corrugated Paperboard Box Laminated Functional MA Film for Freshness Extension of Tomato (기능성 골판지 상자에 포장된 토마토의 신선도)

  • Park, Hyung-Woo;Kang, Jin-Kyung;Park, Jong-Dae;Kim, Dong-Man;Kim, Kee-Jeong
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2001
  • This study was measured weight loss, total ascorbic acid, titratable acidity, and soluble solids content and overall appearances to investigate the effect of FC(corrugated fiberboard box laminated with functional MA film)box, LDPE film, CE(functional MA film)pouches and double wall corrugated fiberboard box during storage at $20^{\circ}C$. Weight loss of tomato packed with control, LDPE, CE and FC box at $25^{\circ}C$ after 7 days were 5.3%, 1.5%, 1.3%, and 1.5%, respectively. Weight loss of control was 3.8% higher than that of FC box. Total ascorbic acid content(TAA) of tomato after 7. days, control was 6.89 mg%, LDPE was 8.62 and CE was 8.53mg%, FC was 8.42mg%. TAA of LDPE, CE and FC was higher than that of control. Titratable acidity of tomato packed with LDPE, FC and CE was higher than that of control. Overall appearances of tomato packed with LDPE, CE and FC was better than that of control. Functional MA film laminated in corrugated paperboard box(FC) showed to be able to used as a packaging box of tomato.

  • PDF

A numerical study on effects of thermal buoyance force on number of jet fans for smoke control (도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.301-310
    • /
    • 2013
  • Jet fans are installed in road tunnels in order to maintain critical velocity when fire occurs. Generally the number of jet fans against fire are calculated by considering critical velocity and flow resistance by wall friction, vehicle drag force, thermal buoyance force and natural wind. In domestic case, thermal buoyance force is not considered in estimating the number of jet fans. So, in this study, we investigated the pressure loss due to the thermal buoyance force induced by tunnel air temperature rise and the impact of thermal buoyance force on the number of jet fans by the numerical fire simulation for the tunnel length(500, 750, 1000, 1500, 2000, 3500m) and grade (-1.0, -1.5, -2.0%). Considering the thermal buoyance force, number of jet fans have to be increased. Especially in the case of 100MW of heat release rate, the pressure loss due to thermal buoyance force exceed the maximum pressure loss due to vehicle drag resistance, so it is analyzed that number of 2~11 jet fans are needed additionally than current design criteria. Thus, in case of estimating the number of jet fans, it must be considered of thermal buoyance force induced tunnel air temperature rise by fire.

The Loss Prevention System of Smart Device Using by iBeacon (iBeacon을 이용한 스마트 디바이스 분실 방지 시스템)

  • Nam, ChoonSung;Jung, HyunHee;Shin, DongRyeol
    • Journal of Internet Computing and Services
    • /
    • v.15 no.6
    • /
    • pp.27-34
    • /
    • 2014
  • Todays, the rapid technical progress of smart device has been used for various social (wall-fare) services in our lives. Especially, most of these services are based on the Local-based Services (LBS) and this technology is getting popular more and more compared with before. Basically, LBS is able to support various types of geographical services such as vehicles' navigation services, Augmented reality services as using extensional local information such as GPS. However, LBS has serious mathematical vulnerability on the services frequently because of its miscalculated GPS data under interior and ambiguous geographical environment such like shadowed area. So, to overcome this limitation, iBeacon, which would be able to mitigate LBS miscalculation process, has been proposed recently among network experts. Compared with other wireless technologies, iBeacon is able to determine the accurate geographical data of certain local positions easily because it is not only designed based on low-powered data transmitting technology, but also, it can be much easy to be deployed. As users' dependency of smart devices are getting higher and higher and the use of smart device is also getting complex more and more, the users prefer to use various types of smart devices at one time. Therefore, in this paper, we propose the loss prevention system that is able to interwork smart devices networks as using iBeacon technology for users' better conveniences.

An Analysis of the Loss of Residual Heat Removal System Event for Pressurized Water Reactor at Reduced Inventory Operation (가압경수로의 저수위 운전시 잔열제거계통 상실사고에 대한 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.645-660
    • /
    • 1995
  • The loss of Residual Heat Removal System (RHRS) event during reduced inventory operation for the Korean Standard Nuclear Power Plants (KSNPPS) is simulated by RELAP5/MOD3 and RELAP5/MOD3.1 Tn cases are considered : Base case for an intact Reactor Coolant System (RCS) with no tent and a vent case for an open system. Comparative simulations of base case are peformed by RELAP5/MOD3 and RELAP5/MOD3. 1 computer codes. The results of too simulations are generally in good qualitative and quantitative agreement. However, since the results of RELAP5/MOD3 simulation reveals the deficiency of RELAP5/MOD3 wall heat model, the RELAP5/AOD3.1 computer code is used for the simulation of the vent case. The analysis result of base case show that two steam generators are insufficient to remove decay heat at one day after shutdown, where the RCS is closed. The RCS pressure increased continuously and reached the RCS temporary boundaries design pressure of 0.24 MPa around 4,000 seconds. In the vent case with a flow capacity equivalent to three times the capacity of Pressurizer Safety Valve (PSV), it is shown that the RCS Pressure does not reach 0.24 MPa and core uncovery does not occur until 10,000 seconds. The detailed discussions on the results of this study suggest the feasibility of RELAP5/AOD3.1 as an analysis tool for the simulation of the loss of RHRS event at reduced inventory operation. The results of this study also provide insight for the determination of proper vent capacity.

  • PDF

Thermal Energy Balance Analysis of a Packed Bed for Rock Cavern Thermal Energy Storage (충전층을 이용한 암반공동 열에너지저장시스템의 열에너지 수지 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.241-259
    • /
    • 2013
  • A packed bed thermal energy storage (TES) consisting of solid storage medium of rock or concrete through which the heat transfer fluid is circulated is considered as an attractive alternative for high temperature sensible heat storage, because of the economical viability and chemical stability of storage medium and the simplicity of operation. This study introduces the technologies of packed bed thermal energy storage, and presents a numerical model to analyze the thermal energy balance and the performance efficiency of the storage system. In this model, one dimensional transient heat transfer problem in the storage tank is solved using finite difference method, and temperature distribution in a storage tank and thermal energy loss from the tank wall can be calculated during the repeated thermal charging and discharging modes. In this study, a high temperature thermal energy storage connected with AA-CAES (advanced adiabatic compressed air energy storage) was modeled and analyzed for the temperature and the energy balance in the storage tank. Rock cavern type TES and above-ground type TES were both simulated and their results were compared in terms of the discharging efficiency and heat loss ratio.

Measurement and evaluation of speech privacy in university office rooms (대학 내 사무실의 스피치 프라이버시 측정 및 평가)

  • Lim, Jae-Seop;Choi, Young-Ji
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.396-405
    • /
    • 2019
  • The speech privacy of closed office rooms located in a university campus was measured and assessed in terms of SPC (Speech Privacy Class) values. The measurements of two quantities, the LD (Level Difference) between a source and a receiving room, and the background noise level ($L_b$) at the receiving room were carried out in 5 rooms located in 3 different buildings in the university campus. Each of the 5 rooms was adjacent to both offices and corridors through walls. The TL (Transmission Loss) between the source and the receiver room was also measured to compare the difference of two standard methods, ASTM E2836-10 and KS F 2809. The present results show that the speech privacy of the 5 office rooms is not met the requirement for a minimum SPC values of 70. A minimum LD value of 41 dB between the source and the receiver room should be achieved for having a SPC value of 70 when the mean measured value of $L_b$ at the receiving room is 29.2 dB. That is, the TL(avg) value averaged over the octave bands from 160 Hz to 5000 Hz between the source and the receiver room should be or greater than 40 dB. The most important architectural factor influencing the LD value is the presence of openings, such as doors, and windows, on the adjacent walls between the source and receiving room. Therefore, if the opening of the adjacent wall is replaced by an opening with high sound insulation, the appropriate SPC value of the research and office rooms can be achieved.

Comparison of Changes in Cell Wall Characteristics during Storage in 'Niitaka' and 'Pingguoli' Pear Fruits (동양배 '신고'와 '사과배' 과실의 저장 중 세포벽 특성의 변화 비교)

  • Kim, Jin-Gook;Piao, Yilong;Chun, Jong-Pil;Kataoka, Ikuo;Hwang, Yong-Soo
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • The characteristics of fruit ripening and cell wall modifications of two oriental pear fruits were compared during storage. The loss of fresh weight was lower in 'Pingguoli' than 'Niitaka', probably due to the difference in wax accumulation and skin structure. 'Pingguoli' produced much higher amount of ethylene and showed climacteric ripening pattern, but this response was not found in 'Niitaka'. A significant difference in soluble pectin contents was found, thus, the amount of water soluble pectins were much higher in 'Niitaka' at harvest but this difference was not significant at later stage of storage. A severe loss of water soluble pectins in 'Niitaka' was confirmed whereas a similar tendency was not found in CDTA soluble ones. Even the amount of $Na_2CO_3$ soluble pectins was relatively low, 'Pingguoli' contained approximately 2 times higher than 'Niitaka' and both cultivars showed an increasing tendency in $Na_2CO_3$ soluble polymers at later stage of storage. No significant difference in alkali soluble polysaccharides (hemicelluloses fraction) was found between both cultivars. There was a significant change in gel filtration profiles regardless of cultivars, especially in water soluble pectins resulting from severe depolymerization probably due to degradation of higher molecular weight pectins and loss of their side chains. In gel filtration profiles of $Na_2CO_3$ soluble pectins, neutral sugars were evenly distributed regardless of molecular size of pectic polymers but the decrease of high molecular weight fraction was found. In comparison of alkali soluble polymers, a similar trend was found, that is, there was no difference in gel filtration profiles but 'Niitaka' seemed to have longer side chains in alkali soluble polysaccharides in both 4% and 24% of KOH soluble fractions.

  • PDF

Studies on the Breeding of Cold Hardiness and Technique of Overwintering Cultivation in Citrus (감귤(柑橘)의 내한성(耐寒性) 품종육성(品種育成) 및 내한(耐寒) 재배기술(栽培技術)에 관(關)한 연구(硏究))

  • Kim, Chi-moon;Song, Ho-kyung;Kim, Chung-suk
    • Korean Journal of Agricultural Science
    • /
    • v.4 no.2
    • /
    • pp.126-140
    • /
    • 1977
  • Present studies were carried out for breeding cold resistant clones of Citrus, improving overwintering techniques of Citrus in Jeju island as well as other southern region, Result obtained were as follows 1. In the vinyl house covered with two sheets of straw mat, 12 indivuals were found as non-injury and 15 were slightly injured by leaf freeging test at $-9^{\circ}C$ for 2 hours treatment. 2. In the condition of vinyl house covered with straw mat and viny film mulching and heat-in by sun-light, the inside temperature of vinyl house were not lowered below $-3^{\circ}C$ and the ground temperatura in vinyl house keeps above $0^{\circ}C$ during winter though outdoor temperature were lower by $-15^{\circ}C$(Daejeon area). 3. The vinyl tunnel inside the vinyl house and vinyl film mulching on ground position showed greater effectiveness for preventing heat loss from house but there were no significant difference between the color of vinyl film covered the tunnel. 4. In the vertical distribution of maximum temperature in vinyl house, the upper space was slightly higher than the lower position at high temperature condition, while minimum temperature was distributed as higher as the middle position, ground surface and upper position in order at low temperature condition 5. In the horizontal distribution of temperature in vinyl house, ground and surface-temperature of north side was lower than the other sides, and citrus planted within 30cm from north side wall died by cold injury and in the other side near wall appeared slight symptom of cold injury. 6. The insulating trench ($30{\times}30{\times}30cm$) packed with straw bundle installed under north wall might be effective to prevent heat loss of ground temperature. 7. In cloudy and snowy day, the temperature difference between indoor and outdoor were less, and the indoor temperature were maintained highly during night due to the effect of prevention of heat loss. 8. The highest temperature in a day was observed at about P.M. 3 both inside and outside of vinyl house and the lowest temperature was observed at about A.M. 6. The difference between the highest and lowest temperature of indoor in a sunny day was $19^{\circ}C$, compared with $9^{\circ}C$ on a cloudy or snowy day in late November. Especially, lowering of temperature in a snowy day was so less that the curve of temperature change was comparatively constant, 9. If the effective methods of citrus cultivation in vinyl house with improved clone such as hardiness. semi-dwarf and spur type are applied, it might be possible to cultivate the citrus tree safely in Jeju island as well as other southern rejion and to magnity the cultivation of citrus tree.

  • PDF

Study on the Heat Transfer Phenomenon around Underground Concrete Digesters for Bigas Production Systems (생물개스 발생시스템을 위한 지하매설콘크리트 다이제스터의 열전달에 관한 연구)

  • 김윤기;고재균
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.22 no.1
    • /
    • pp.53-66
    • /
    • 1980
  • The research work is concerned with the analytical and experimental studies on the heat transfer phenomenon around the underground concrete digester used for biogas production Systems. A mathematical and computational method was developed to estimate heat losses from underground cylindrical concrete digester used for biogas production systems. To test its feasibility and to evaluate thermal parameters of materials related, the method was applied to six physical model digesters. The cylindrical concrete digester was taken as a physical model, to which the model,atical model of heat balance can be applied. The mathematical model was transformed by means of finite element method and used to analyze temperature distribution with respect to several boundary conditions and design parameters. The design parameters of experimental digesters were selected as; three different sizes 40cm by 80cm, 80cm by 160cm and l00cm by 200cm in diameter and height; two different levels of insulation materials-plain concrete and vermiculite mixing in concrete; and two different types of installation-underground and half-exposed. In order to carry out a particular aim of this study, the liquid within the digester was substituted by water, and its temperature was controlled in five levels-35。 C, 30。 C, 25。 C, 20。C and 15。C; and the ambient air temperature and ground temperature were checked out of the system under natural winter climate conditions. The following results were drawn from the study. 1.The analytical method, by which the estimated values of temperature distribution around a cylindrical digester were obtained, was able to be generally accepted from the comparison of the estimated values with the measured. However, the difference between the estimated and measured temperature had a trend to be considerably increased when the ambient temperature was relatively low. This was mainly related variations of input parameters including the thermal conductivity of soil, applied to the numerical analysis. Consequently, the improvement of these input data for the simulated operation of the numerical analysis is expected as an approach to obtain better refined estimation. 2.The difference between estimated and measured heat losses was shown to have the similar trend to that of temperature distribution discussed above. 3.It was found that a map of isothermal lines drawn from the estimated temperature distribution was very useful for a general observation of the direction and rate of heat transfer within the boundary. From this analysis, it was interpreted that most of heat losses is passed through the triangular section bounded within 45 degrees toward the wall at the bottom edge of the digesten Therefore, any effective insulation should be considered within this region. 4.It was verified by experiment that heat loss per unit volume of liquid was reduced as the size of the digester became larger For instance, at the liquid temperature of 35˚ C, the heat loss per unit volume from the 0. 1m$^3$ digester was 1, 050 Kcal/hr m$^3$, while at for 1. 57m$^3$ digester was 150 Kcal/hr m$^3$. 5.In the light of insulation, the vermiculite concrete was consistently shown to be superior to the plain concrete. At the liquid temperature ranging from 15。 C to 350 C, the reduction of heat loss was ranged from 5% to 25% for the half-exposed digester, while from 10% to 28% for the fully underground digester. 6.In the comparison of heat loss between the half-exposed and underground digesters, the heat loss from the former was fr6m 1,6 to 2, 6 times as much as that from the latter. This leads to the evidence that the underground digester takes advantage of heat conservation during winter.

  • PDF