• 제목/요약/키워드: Wall Loss

검색결과 786건 처리시간 0.021초

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

60GHz 대역에서의 전파 환경별 경로손실 및 도래각 측정 (Radio Path Loss and Angle of Arrival Measurements to the Radio Environments at 60GHz)

  • 송기홍
    • 한국정보통신학회논문지
    • /
    • 제11권12호
    • /
    • pp.2233-2240
    • /
    • 2007
  • 피코셀 무선 통신용으로 이용이 확대되고 있는 밀리미터 파대의 전파 특성을 분석하기 위하여 60GHz대역에서 신호 세기를 측정하고, 측정된 데이터를 이용하여 경로손실 지수 및 표준편차를 제시하였다. 수신 신호 세기에 영향을 미치는 다중경로파의 도래 방향을 파악하기 위하여 도래각의 분포를 측정하였다. 분석 결과, 측정 환경에서 경로손실 지수는 자유공간에서의 경로손실 지수인 2보다 작게 나타났으며, 신호세기에 많은 영향을 미치는 바닥면의 재질에 따라 다르게 나타났다. 다중 경로파의 도래각 분포는 송수신기가 위치한 주변 환경 구조에 따라 달라진다. 즉, 체육관, 운동장 등과 같이 측정 환경이 넓은 곳에서는 직접파와 지면 반사파를 제외한 다중경로파를 확인하기 어려웠으나 복도에서는 양쪽 벽면에 의한 다중경로파도 수신기에 도래하는 것을 수 있다. 60GHz대의 주파수 특성상 반사파의 크기는 직접파의 크기에 비해 미약하여 수신 신호 세기에 거의 영향을 주지 못하는 것을 알 수 있다.

실측 실험을 통한 단열문의 열성능 평가 (Thermal Performance Assessment of Insulated door by experiment.)

  • 장철용;김치훈;안병립;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.47-52
    • /
    • 2011
  • Currently, Exterior wall's U-value about building envelope is 0.36 W/$m^2K$(Central Region), but window's one is 2.1 W/$m^2K$ according to air gap of glazing, filling gas, coating and type of windows. The door"s one is 1.6~5.5 W/$m^2{\cdot}K$ depending on material and configuration of door. As such, energy loss per unit of door is considerably larger like windows. The door for the recognition was relatively low because energy loss through the door is relatively small compared to window area. In this paper, thermal performance was analyzed through simulation targeting the door which has thermal break that can improve the insulation performance and doesn't have one. As a results of simulations, case1 was calculated as the average of 1.63 w/m2k and case 2 was calculated as the average of 4.14 w/m2k. The thermal performance of door depends on the type and condition of insulations. As a results of final simulations, Case1 was calculated as 1.06 w/m2k and Case2 was calculated as 1.27 w/m2k. As a results of the experiments, thermal performance of case 1 was measured as 1.28 w/m2k. Error between experiments and simulations is considered problems encountered when creating the samples. The effect of door frame on the overall thermal performance is slight because it's a small proportion of the door frame.

아파트 단위 세대의 수직 위치 별 에너지 및 물 사용 규모와 패턴에 관한 연구 (A Study on the Energy and Water Consumption and their Patterns as Vertical Locations of Apartment Housing Units)

  • 송동훈;김경태;이승준;신현익
    • 대한건축학회논문집:계획계
    • /
    • 제33권12호
    • /
    • pp.53-63
    • /
    • 2017
  • The purpose of this study is to present an integrated analysis for energy use and its patterns as vertical locations of the dwelling units in apartment buildings which are located in an urban area and constructed by a renowned contractor. In order to enhance the effectiveness of the method, the original data of electricity, water, and gas bills which directly reflect the energy use are sorted and analyzed into several groups as vertical locations in each building. And also, by use of comparing and contrasting the data on a monthly and yearly basis, the accuracy of analyses for seasonal energy use and its patterns is strengthened. Comparative analyses used in this study describe the results that vertical locations of dwelling units do not have much influence on electricity and water usage, but are closely related with gas usage for a heating season. According to the analysis of gas usage, the units on the ground and right above pilotis need enhancement in the insulations for heating to mitigate energy loss. Also, the analysis for the middle floor units in each group describe the fact that the gas usage of the units on the ground is consumes 1.5 times greater than that of the typical floors. Therefore, enhanced insulation strategies need to be considered against the adverse condition that the heat loss increases as the wall facing the outside air increases or as the wind velocity increases through the pilotis.

A parametric study of settlement and load transfer mechanism of piled raft due to adjacent excavation using 3D finite element analysis

  • Karira, Hemu;Kumar, Aneel;Hussain Ali, Tauha;Mangnejo, Dildar Ali;Mangi, Naeem
    • Geomechanics and Engineering
    • /
    • 제30권2호
    • /
    • pp.169-185
    • /
    • 2022
  • The urbanization and increasing rate of population demands effective means of transportation system (basement and tunnels) as well as high-rise building (resting on piled foundation) for accommodation. Therefore, it unavoidable to construct basements (i.e., excavation) nearby piled foundation. Since the basement excavation inevitably induces soil movement and stress changes in the ground, it may cause differential settlements to nearby piled raft foundation. To understand settlement and load transfer mechanism in the piled raft due to excavation-induced stress release, numerical parametric studies are carried out in this study. The effects of excavation depths (i.e., formation level) relative to piled raft were investigated by simulating the excavation near the pile shaft (i.e., He/Lp=0.67), next to (He/Lp=1.00) and below the pile toe (He/Lp=1.33). In addition, effects of sand density and raft fixity condition were investigated. The computed results have revealed that the induced settlement, tilting, pile lateral movement and load transfer mechanism in the piled raft depends upon the embedded depth of the diaphragm wall. Additional settlement of the piled raft due to excavation can be account for apparent loss of load carrying capacity of the piled raft (ALPC). The highest apparent loss of piled raft capacity ALPC (on the account of induced piled raft settlement) of 50% was calculated in in case of He/Lp = 1.33. Furthermore, the induced settlement decreased with increasing the relative density from 30% to 90%. On the contrary, the tilting of the raft increases in denser ground. The larger bending moment and lateral force was induced at the piled heads in fixed and pinned raft condition.

CSPACE for a simulation of core damage progression during severe accidents

  • Song, JinHo;Son, Dong-Gun;Bae, JunHo;Bae, Sung Won;Ha, KwangSoon;Chung, Bub-Dong;Choi, YuJung
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3990-4002
    • /
    • 2021
  • CSPACE (Core meltdown, Safety and Performance Analysis CodE for nuclear power plants) for a simulation of severe accident progression in a Pressurized Water Reactor (PWR) is developed by coupling of verified system thermal hydraulic code of SPACE (Safety and Performance Analysis CodE for nuclear power plants) and core damage progression code of COMPASS (Core Meltdown Progression Accident Simulation Software). SPACE is responsible for the description of fluid state in nuclear system nodes, while COMPASS is responsible for the prediction of thermal and mechanical responses of core fuels and reactor vessel heat structures. New heat transfer models to each phase of the fluid, flow blockage, corium behavior in the lower head are added to COMPASS. Then, an interface module for the data transfer between two codes was developed to enable coupling. An implicit coupling scheme of wall heat transfer was applied to prevent fluid temperature oscillation. To validate the performance of newly developed code CSPACE, we analyzed typical severe accident scenarios for OPR1000 (Optimized Power Reactor 1000), which were initiated from large break loss of coolant accident, small break loss of coolant accident, and station black out accident. The results including thermal hydraulic behavior of RCS, core damage progression, hydrogen generation, corium behavior in the lower head, reactor vessel failure were reasonable and consistent. We demonstrate that CSPACE provides a good platform for the prediction of severe accident progression by detailed review of analysis results and a qualitative comparison with the results of previous MELCOR analysis.

Overview of separate effect and integral system tests on the passive containment cooling system of SMART100

  • Jin-Hwa Yang;Tae-Hwan Ahn;Hong Hyun Son;Jin Su Kwon;Hwang Bae;Hyun-Sik Park;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1066-1080
    • /
    • 2024
  • SMART100 has a containment pressure and radioactivity suppression system (CPRSS) for passive containment cooling system (PCCS). This prevents overheating and over-pressurization of a containment through direct contact condensation in an in-containment refueling water storage tank (IRWST) and wall condensation in a CPRSS heat exchanger (CHX) in an emergency cool-down tank (ECT). The Korea Atomic Energy Research Institute (KAERI) constructed scaled-down test facilities, SISTA1 and SISTA2, for the thermal-hydraulic validation of the SMART100 CPRSS. Three separate effect tests were performed using SISTA1 to confirm the heat removal characteristics of SMART100 CPRSS. When the low mass flux steam with or without non-condensable gas is released into an IRWST, the conditions for mitigation of the chugging phenomenon were identified, and the physical variables were quantified by the 3D reconstruction method. The local behavior of the non-condensable gas was measured after condensation inside heat exchanger using a traverse system. Stratification of non-condensable gas occurred in large tank of the natural circulation loop. SISTA2 was used to simulate a small break loss-of-coolant accident (SBLCOA) transient. Since the test apparatus was a metal tank, compensations of initial heat transfer to the material and effect of heat loss during long-term operation were important for simulating cooling performance of SMART100 CPRSS. The pressure of SMART100 CPRSS was maintained below the design limit for 3 days even under sufficiently conservative conditions of an SBLOCA transient.

치주 골내낭에서 anorganic bovine-derived hydroxyapatite matrix(ABM)/cell binding peptide(P-15)의 임상적효과 (Clinical effects of combination anorganic bovine-derived hydroxyapatite matrix(ABM)/cell binding peptide (P-15) in periodontal intrabony defects)

  • 원미숙;백정원;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.565-576
    • /
    • 2002
  • The ultimate goal of periodontal therapy is the regeneration of periodontal tissue which has been lost due to destructive periodontal disease. To achieve periodontal regeneration, various kinds of methods have been investigated and developed, including guided tissue regeneration and bone graft. Bone graft can be catagorized into autografts, allografts, xenografts, bone substitutes. And materials of all types have different biological activity and the capacity for periodontal regeneration, but ideal graft material has not been developed that fits all the requirement of ideal bone graft material. Intensive research is underway to identity, purify, synthesize a variety biologic modulators that may enhance wound healing and regeneration of lost tissues in periodontal therapy. The present study evaluates the effects of ABM/P-15 on the periodontal regeneration in intrabony defects of human. We used thirty four 2-wall or 3-wall osseous defects in premolars and molars of chronic peridontitis patient that have more than 5mm pockets and more than 3mm in intrabony defect. 12 negative control group underwent flap procedure only, 11 positive control group received DFDBA graft with flap procedure, and 11 experimental group received ABM/P-15 graft with flap procedure. The changes of probing pocket depth, loss of attachment and bone probing depth following 6months after treatment revealed the following results: 1. The changes of probing pocket depth showed a statistically significant decrease between after scaling and 6months after treatment in negative control(2.0${\pm}$0.9mm), positive control(3.0${\pm}$0.9mm), and experimental group (3.4${\pm}$1.5mm) (P<0.01). Significantly more reduction was seen in experimental group compared to negative control group (P<0.05). 2. The changes of loss of attachment showed a statistically significant decrease between after scaling and 6months after treatment in positive control(2.0${\pm}$0.6mm), and experimental group (2.2${\pm}$l.0mm) except negative control group(0.1${\pm}$0.7mm) (P<0.01). Significantly more reduction was seen in both experimental and positive control group compared to negative control group(P<0.05). 3. The changes of bone probing depth showed a statistically significant decrease between after scaling and 6months after treatment in positive control(2.7${\pm}$l.0mm), and experimental group (3.4${\pm}$1.3mm) except negative control(0.l${\pm}$0.9mm) (9<0.01). Significantly more reduction was seen in both experimental and positive control group compared to negative control group (P<0.05). The results suggest that the use of ABM/P-15 in the treatment of periodontal intrabony defects can reduce loss of attachment and bone probing depth more than flap operation only. It suggests that ABM/P-15 may be an effective bone graft material for the regeneration of periodontal tissue in intrabony defects.

유리커튼월 수막시스템 분무헤드의 화재 실험 연구 (Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System)

  • 김성원;남지우;조성욱;유홍선;남준석;김동준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.31-40
    • /
    • 2016
  • 최근 초고층 건물 외벽에는 유리 커튼월 시스템이 많이 적용되고 있으며, 이러한 초고층 건물은 화재 발생 시 연돌효과 및 외부 기류에 따라 수직으로 화재가 급격하게 확산되는 특성을 가지고 있다. 기존에 사용되고 있는 스프링클러헤드는 상층부로의 화재 확산을 효과적으로 방지 할 수 없기 때문에 화재시 막대한 재산 및 인명피해를 초래한다. 따라서 본 연구에서는 보다 넓은 유리커튼월 면적을 방호할 수 있는 수막을 형성하고 층간 화재 확산을 방지 할 수 있는 수막 헤드를 개발하였다. 수막 헤드의 성능을 검증하기 위하여 살수 실험 장치를 구성하고 이를 활용하여 기존 스프링클러 헤드와 살수 패턴을 비교, 분석하였다. 상층부로의 화재 전파 차단 성능을 검토하기 위하여 2층 유리커튼월로 구성되어 있는 실험 장치를 활용하여 화재 실험을 수행하였다. 이를 통해 본 연구에서 제시한 수막 헤드가 기존 스프링클러헤드 보다 효과적으로 화염을 차단하는 것을 확인하였고 수치해석을 통해 최초 크랙 위치 및 파단 임계 온도를 분석하였다.

경남 밀양지역 납석광상과 안산암질 모암의 지구화학적 연구 (A Geochemical Study on Pyrophyllite Deposits and Andesitic Wall-Rocks in the Milyang Area, Kyeongnam Province)

  • 오대균;전효택;민경원
    • 자원환경지질
    • /
    • 제25권1호
    • /
    • pp.27-39
    • /
    • 1992
  • Several pyrophyllite deposits occur around the Milyang area where Cretaceous andesitic rocks and spatially related granitic rocks are widely distributed. Pyrophyllite ores consist mainly of pyrophyllite, and quartz with small amount of sericite, pyrite, dumortierite, and diaspore. The andesitic rocks and spatially related granitic rocks in this area suggest that they could be formed from the same series of a calc-alkaline magma series. The contents of $SiO_2$, $Al_2O_3$, LOI(loss on ignition) are enriched, and $K_2O$, $Na_2O$, CaO, MgO, $Fe_2O_3$ are depleted in altered andesitic rocks and ores. Enrichment of As, Cr, Sr, V, Sb and depletion of Ba, Cs, Ni, Rb, U, Y, Co, Sc, Zn are characteristic during mineralization. The pyrophyllite ores can be discriminated from the altered-and unaltered wall-rocks by an increasing of $(La/Lu)_{cn}$ from 4.18~22.13 to 8.98~55.05. In R-mode cluster analysis, Yb-Lu-Y, La-Ce-Hf-Th-U-Zr, $TiO_2-V-Al_2O_3$, Sm-Eu, $CaO-Na_2O-MnO$, Cu-Zn-Ag, $K_2O-Rb$ are closely correlated. In the discriminant analysis of multi-element data, $P_2O_5$, As, Cr and $Fe_2O_3$, Sr are helpful to identify the ores from the unaltered-and altered wall-rocks. In the factor analysis, the factors of alteration of andesitic rocks and ore mineralization were extracted. In the change of ions per unit volume, $SiO_2$, $Al^{3+}$ and LOI are enriched and $Na^+$, $K^+$, $Ca^{2+}$, $Mg^{2+}$, $Mn^{2+}$ and $Fe^{3+}$ are depleted during the alteration processes. The Milyang and the Sungjin pyrophyllite deposits could be mineralized by hydrothermal alteration in a geochemical condition of low activity ratio of alkaline ions to hydrogen ion with reference to spatially related granitic rocks.

  • PDF