• Title/Summary/Keyword: Walking Pattern

Search Result 342, Processing Time 0.023 seconds

Dynamic Walking for a Biped Robot Using Fuzzy Model (퍼지 모델을 이용한 이족 로봇의 동적 보행 설계)

  • Jang, Kwon-Kyu;Joo, Young-Hoon;Park, Hyun-Bin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.4
    • /
    • pp.481-486
    • /
    • 2004
  • The biped robot has the better mobility than the conventional wheeled robot. Since a biped robot tends to tip over easily, it is necessary to take stability into account when determining a walking pattern. To ensure the dynamic stability of the biped robot, we have to adapt the ground conditions with a foot motion and maintain motion, and ensure its stability through the kinematics and dynamics analysis. But its mathematic model is not too easy. In this paper, in order to ensure the dynamic stability of a biped robot, we design the fuzzy model and confirm the realization possibility of the proposed method through some simulations.

Application of the Chaos Theory to Gait Analysis (카오스 이론을 적용한 보행분석 연구)

  • Park, Ki-Bong;Ko, Jae-Hun;Moon, Byung-Young;Suh, Jeung-Tak;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.194-201
    • /
    • 2006
  • Gait analysis is essential to identify accurate cause and knee condition from patients who display abnormal walking. Traditional linear tools can, however, mask the true structure of motor variability, since biomechanical data from a few strides during the gait have limitation to understanding the system. Therefore, it is necessary to propose a more precise dynamic method. The chaos analysis, a nonlinear technique, focuses on understand how variations in the gait pattern change over time. Eight healthy eight subjects walked on a treadmill for 100 seconds at 60 Hz. Three dimensional walking kinematic data were obtained using two cameras and KWON3D motion analyzer. The largest Lyapunov exponent from the measured knee angular displacement time series was calculated to quantify local stability. This study quantified the variability present in time series generated from gait parameter via chaos analysis. Knee flexion-extension patterns were found to be chaotic. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.

Socket Pressure Distribution of the Uni-Lateral Trans-Femoral Amputee with a Suction Socket (흡착식 소켓을 착용한 일측 대퇴절단환자의 소켓내부압력분포)

  • Jang, Yun-Hui;Yang, Gil-Tae;Im, Song-Hak;Mun, Mu-Seong;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.417-422
    • /
    • 1998
  • The study was explored socket pressure distributions on a trans-femoral amputee with a suction socket in static and dynamic situations. Even when the amputee stood in the anatomically neutral position, significant pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free level walking, a significant shifting pattern of pressure concentration areas was observed. High socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.

  • PDF

Indoor Position Detection Algorithm Based on Multiple Magnetic Field Map Matching and Importance Weighting Method (다중 자기센서를 이용한 실내 자기 지도 기반 보행자 위치 검출 정확도 향상 알고리즘)

  • Kim, Yong Hun;Kim, Eung Ju;Choi, Min Jun;Song, Jin Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.3
    • /
    • pp.471-479
    • /
    • 2019
  • This research proposes a indoor magnetic map matching algorithm that improves the position accuracy by employing multiple magnetic sensors and probabilistic candidate weighting function. Since the magnetic field is easily distorted by the surrounding environment, the distorted magnetic field can be used for position mapping, and multiple sensor configuration is useful to improve mapping accuracy. Nevertheless, the position error is likely to increase because the external magnetic disturbances have repeated pattern in indoor environment and several points have similar magnetic field distortion characteristics. Those errors cause large position error, which reduces the accuracy of the position detection. In order to solve this problem, we propose a method to reduce the error using multiple sensors and likelihood boundaries that uses human walking characteristics. Also, to reduce the maximum position error, we propose an algorithm that weights according to their importance. We performed indoor walking tests to evaluate the performance of the algorithm and analyzed the position detection error rate and maximum distance error. From the results we can confirm that the accuracy of position detection is greatly improved.

Effects of Treatment Using PNF Pattern Irradiation in the Weight-Bearing Position on Pain and Foot Alignment in a Patient with Patellofemoral Pain Syndrome: A Single-Subject Experimental Study

  • Dong-Kyu Kim;Duck-Won Oh
    • PNF and Movement
    • /
    • v.22 no.2
    • /
    • pp.171-180
    • /
    • 2024
  • Purpose: This study aimed to investigate the use of insoles in patients with temporomandibular joint disorders to assess the function and changes in pain when walking in daily life. Methods: Sixty-five patients with temporomandibular joint disorder, were selected, with 34 assigned to the control group and 31 to the experimental group. The control group walked more than 7,000 steps per day in their daily life, while the experimental group wore insoles and was instructed to take at least 7,000 steps every day. To evaluate the effect on temporomandibular joint pain, steady-state pain, maximum mouth opening, average pain, and the most severe pain were measured before and after the experiment. In addition, to determine function, mouth opening in a comfortable state, mouth opening pain, and the point of sound and the maximum degree of mouth opening were evaluated before and after the experiment. Results: After the experiment, pain, mouth opening, and sound points showed significant differences compared to the control group. However, there was no significant difference in the maximum mouth opening range. Conclusion: The application of air insoles to patients with temporomandibular joint disorder confirmed the function of the temporomandibular joint and its positive effects on pain.

Development of a 2-DOF Ankle Mechanism for Gait Rehabilitation Robots (보행 재활 로봇을 위한 2자유도 족관절 기구 개발)

  • Heo, Geun Sub;Kang, Oh Hyun;Lee, Sang Ryong;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.6
    • /
    • pp.503-509
    • /
    • 2015
  • In this paper, we designed and tested an ankle joint mechanism for a gait rehabilitation robot. Gait rehabilitation programs are designed to improve the natural leg motion of patients who have lost their walking capabilities by accident or disease. Strengthening the muscles of the lower-limbs and stimulation of the nervous system corresponding to walking helps patients to walk again using gait assistive devices. It is an obvious requirement that the rehabilitation system's motion should be similar to and as natural as the normal gait. However, the system being used for gait rehabilitation does not pay much attention to ankle joints, which play an important role in correct walking as the motion of the ankle should reflect the movement of the center of gravity (COG) of the body. Consequently, we have designed an ankle mechanism that ensures the safety of the patient as well as efficient gait training. Also, even patients with low leg muscle strength are able to operate the ankle joint due to the direct-drive mechanism without a reducer. This safety feature prevents any possible adverse load on the human ankle. The additional degree of freedom for the roll motion achieves a gait pattern which is similar to the normal gait and with a greater degree of comfort.

Context Awareness Using Wireless Biosignal Processing (무선 생체신호 처리를 이용한 상황인식)

  • Lee Sang-Bock;An Byung-Ju;Lee Sanyol;Lee Jun-Haeng
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.117-126
    • /
    • 2005
  • In this paper, it was suggested method to recognize the motion of a person(lying, sitting, walking, running) using fuzzy inference and wireless biologic signal processing system. These are to Perceive the motion of the person. Furthermore, the information of motion is indispensable parameter for Context Awareness (CA). In the present study, ADXL 202JE accelerometer sensor was used to measure for checking the continuance motion, biological quantify of motion, and motion pattern of a Person. The measured data was transmitted to CA server by Radio Frequency(RF). From the present result, we confirmed that it is difficult to decide the motion of walking and running with only the magnitude of the Longitudinal Accelerometer Average Value(LAAV) and moreover the covariance of LAAV in any block is very useful for CA of walking and running.

  • PDF

Biomechanical Analysis of Arch Support Devices on Normal and Low Arch (정상족과 편평족의 Arch Support 사용에 따른 운동역학적 분석)

  • Park, Seung-Bum;Park, Jae-Young;Kim, Kyung-Hun
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2010
  • The purpose of this study was to the kinetic variables effects from the use of arch support inserts on low-arched people. We selected 10 people for the research and separated them into 2 groups, 5 people for the normal arched group and 5 people for the low arched group. Each group wear shoes which have a 3 step convertible arch support (level 0, level 2, level 5) and we measured their foot pressure and 3D motion analysis data. As a result, we found that the mean pressure at the heel of the low arched group was decreased when using the arch supports. The arch support induced the correct grounding area for the foot and dispersion of foot pressure. 3D motion analysis found that as the height of the arch support was increased, the movement of the Y-axis(inversion-eversion) was increased to relieve the shock to the heel. The arch support insert limited the range of motion(ROM) of the Z-axis(abduction-adduction) of the low arched person's ankle joint and prevented ankle injury caused by the excessive eversion when walking. Low arched people are seen to be easily tired due to the ineffective shock absorption of the knees and abnormal walking motion. In order to improve the problems, a 3 step convertible arch support(level 5) insert would improve the low-arched people's walking ability. In other words, the low arched people should be expected to walk as well as normal arched people when they wear shoes with the arch support insert.

A Study on the Systematization of the Pedestrian Space for the Prevention of Accidents in Urban Areas - The side of Planning and Management - (도시지역 사고예방을 위한 보행공간 체계화에 관한 연구 - 계획과 운영측면에서 -)

  • Hwang, Eui Jin;Ryu, Ji Hyeob;Lim, Ik Hyeon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Walking is one of human functions and has been the base of the development of human civilization. Walking ability had made the first village and urban pattern of the mankind. Cities had been constructed for pedestrian's convenience and happy life. But conventional cities have been crowded by the rapid increasing vehicles and population since material civilization had developed. On the other hand, pedestrian space has been neglected urban districts. Chose this study to suggest a direction for improvement by following the direction of the city characteristics and roadside pedestrian space. 1. Investigate the relationship and the significance and problems of pedestrian space by finding survey of the literature and discussion with those that affect the behavior of the pedestrian environment around. 2. For a comfortable pedestrian space on the improvement of the pedestrian area of space (physical and psychological) and gait characteristics, service levels and basic data. 3. Chose how to extract the most appropriate of the best alternatives presented several proposals based on the above survey of the literature data and field survey.

The Guidelines for Station layouts and Their Assessments in Railroad Transfer Centers (철도 환승센터의 시설배치기준 및 평가방안)

  • Lee, Jong-Kuk;Kim, Si-Gon;Lim, Kwang-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1308-1317
    • /
    • 2009
  • The mass transit networks in Korea, such as buses, metro and subway, are co-related and the number of transfer points, in which a lot of pedestrian movement is generated, are rising. The functions of the transfer centers, in which several travel modes cross at a point, have to include convenience and comfort for pedestrians using the transfer centers, and such functions can make transit a more attractive travel option and thus eventually contribute to increases in ridership. However, the guidelines for station layouts and their assessments in transfer stations are not suggested so far. So the pedestrian pattern data (pedestrian walking distances and times, pedestrian approaching distances and times, pedestrian walking paths in the inside of stations) was collected and analyzed. Based on the results of the analysis, the ways to measure the quality of comfort for those who using transfer facilities were suggested using the times that pedestrians consume to transfer from a travel mode to another. The walking time of pedestrians at the inside of stations was also measured by pre-selected pedestrian pathways as the guidelines for station layout assessment in transfer facilities.

  • PDF