Journal of the Korean Institute of Intelligent Systems
/
v.14
no.4
/
pp.481-486
/
2004
The biped robot has the better mobility than the conventional wheeled robot. Since a biped robot tends to tip over easily, it is necessary to take stability into account when determining a walking pattern. To ensure the dynamic stability of the biped robot, we have to adapt the ground conditions with a foot motion and maintain motion, and ensure its stability through the kinematics and dynamics analysis. But its mathematic model is not too easy. In this paper, in order to ensure the dynamic stability of a biped robot, we design the fuzzy model and confirm the realization possibility of the proposed method through some simulations.
Park, Ki-Bong;Ko, Jae-Hun;Moon, Byung-Young;Suh, Jeung-Tak;Son, Kwon
Transactions of the Korean Society of Mechanical Engineers A
/
v.30
no.2
s.245
/
pp.194-201
/
2006
Gait analysis is essential to identify accurate cause and knee condition from patients who display abnormal walking. Traditional linear tools can, however, mask the true structure of motor variability, since biomechanical data from a few strides during the gait have limitation to understanding the system. Therefore, it is necessary to propose a more precise dynamic method. The chaos analysis, a nonlinear technique, focuses on understand how variations in the gait pattern change over time. Eight healthy eight subjects walked on a treadmill for 100 seconds at 60 Hz. Three dimensional walking kinematic data were obtained using two cameras and KWON3D motion analyzer. The largest Lyapunov exponent from the measured knee angular displacement time series was calculated to quantify local stability. This study quantified the variability present in time series generated from gait parameter via chaos analysis. Knee flexion-extension patterns were found to be chaotic. The proposed Lyapunov exponent can be used in rehabilitation and diagnosis of recoverable patients.
The study was explored socket pressure distributions on a trans-femoral amputee with a suction socket in static and dynamic situations. Even when the amputee stood in the anatomically neutral position, significant pressure concentrations were observed in the lateral, medial, and posterior planes of the socket. During free level walking, a significant shifting pattern of pressure concentration areas was observed. High socket pressure was observed in the lateral, medial-anterior and posterior walls during mid-stance or push-off period. Socket pressure measurement will be one of the good tool to determine the optimal socket-limb interface.
Kim, Yong Hun;Kim, Eung Ju;Choi, Min Jun;Song, Jin Woo
The Transactions of The Korean Institute of Electrical Engineers
/
v.68
no.3
/
pp.471-479
/
2019
This research proposes a indoor magnetic map matching algorithm that improves the position accuracy by employing multiple magnetic sensors and probabilistic candidate weighting function. Since the magnetic field is easily distorted by the surrounding environment, the distorted magnetic field can be used for position mapping, and multiple sensor configuration is useful to improve mapping accuracy. Nevertheless, the position error is likely to increase because the external magnetic disturbances have repeated pattern in indoor environment and several points have similar magnetic field distortion characteristics. Those errors cause large position error, which reduces the accuracy of the position detection. In order to solve this problem, we propose a method to reduce the error using multiple sensors and likelihood boundaries that uses human walking characteristics. Also, to reduce the maximum position error, we propose an algorithm that weights according to their importance. We performed indoor walking tests to evaluate the performance of the algorithm and analyzed the position detection error rate and maximum distance error. From the results we can confirm that the accuracy of position detection is greatly improved.
Purpose: This study aimed to investigate the use of insoles in patients with temporomandibular joint disorders to assess the function and changes in pain when walking in daily life. Methods: Sixty-five patients with temporomandibular joint disorder, were selected, with 34 assigned to the control group and 31 to the experimental group. The control group walked more than 7,000 steps per day in their daily life, while the experimental group wore insoles and was instructed to take at least 7,000 steps every day. To evaluate the effect on temporomandibular joint pain, steady-state pain, maximum mouth opening, average pain, and the most severe pain were measured before and after the experiment. In addition, to determine function, mouth opening in a comfortable state, mouth opening pain, and the point of sound and the maximum degree of mouth opening were evaluated before and after the experiment. Results: After the experiment, pain, mouth opening, and sound points showed significant differences compared to the control group. However, there was no significant difference in the maximum mouth opening range. Conclusion: The application of air insoles to patients with temporomandibular joint disorder confirmed the function of the temporomandibular joint and its positive effects on pain.
Heo, Geun Sub;Kang, Oh Hyun;Lee, Sang Ryong;Lee, Choon-Young
Journal of Institute of Control, Robotics and Systems
/
v.21
no.6
/
pp.503-509
/
2015
In this paper, we designed and tested an ankle joint mechanism for a gait rehabilitation robot. Gait rehabilitation programs are designed to improve the natural leg motion of patients who have lost their walking capabilities by accident or disease. Strengthening the muscles of the lower-limbs and stimulation of the nervous system corresponding to walking helps patients to walk again using gait assistive devices. It is an obvious requirement that the rehabilitation system's motion should be similar to and as natural as the normal gait. However, the system being used for gait rehabilitation does not pay much attention to ankle joints, which play an important role in correct walking as the motion of the ankle should reflect the movement of the center of gravity (COG) of the body. Consequently, we have designed an ankle mechanism that ensures the safety of the patient as well as efficient gait training. Also, even patients with low leg muscle strength are able to operate the ankle joint due to the direct-drive mechanism without a reducer. This safety feature prevents any possible adverse load on the human ankle. The additional degree of freedom for the roll motion achieves a gait pattern which is similar to the normal gait and with a greater degree of comfort.
Lee Sang-Bock;An Byung-Ju;Lee Sanyol;Lee Jun-Haeng
Journal of the Korea Society of Computer and Information
/
v.10
no.6
s.38
/
pp.117-126
/
2005
In this paper, it was suggested method to recognize the motion of a person(lying, sitting, walking, running) using fuzzy inference and wireless biologic signal processing system. These are to Perceive the motion of the person. Furthermore, the information of motion is indispensable parameter for Context Awareness (CA). In the present study, ADXL 202JE accelerometer sensor was used to measure for checking the continuance motion, biological quantify of motion, and motion pattern of a Person. The measured data was transmitted to CA server by Radio Frequency(RF). From the present result, we confirmed that it is difficult to decide the motion of walking and running with only the magnitude of the Longitudinal Accelerometer Average Value(LAAV) and moreover the covariance of LAAV in any block is very useful for CA of walking and running.
The purpose of this study was to the kinetic variables effects from the use of arch support inserts on low-arched people. We selected 10 people for the research and separated them into 2 groups, 5 people for the normal arched group and 5 people for the low arched group. Each group wear shoes which have a 3 step convertible arch support (level 0, level 2, level 5) and we measured their foot pressure and 3D motion analysis data. As a result, we found that the mean pressure at the heel of the low arched group was decreased when using the arch supports. The arch support induced the correct grounding area for the foot and dispersion of foot pressure. 3D motion analysis found that as the height of the arch support was increased, the movement of the Y-axis(inversion-eversion) was increased to relieve the shock to the heel. The arch support insert limited the range of motion(ROM) of the Z-axis(abduction-adduction) of the low arched person's ankle joint and prevented ankle injury caused by the excessive eversion when walking. Low arched people are seen to be easily tired due to the ineffective shock absorption of the knees and abnormal walking motion. In order to improve the problems, a 3 step convertible arch support(level 5) insert would improve the low-arched people's walking ability. In other words, the low arched people should be expected to walk as well as normal arched people when they wear shoes with the arch support insert.
Journal of Korean Society of Disaster and Security
/
v.6
no.1
/
pp.1-8
/
2013
Walking is one of human functions and has been the base of the development of human civilization. Walking ability had made the first village and urban pattern of the mankind. Cities had been constructed for pedestrian's convenience and happy life. But conventional cities have been crowded by the rapid increasing vehicles and population since material civilization had developed. On the other hand, pedestrian space has been neglected urban districts. Chose this study to suggest a direction for improvement by following the direction of the city characteristics and roadside pedestrian space. 1. Investigate the relationship and the significance and problems of pedestrian space by finding survey of the literature and discussion with those that affect the behavior of the pedestrian environment around. 2. For a comfortable pedestrian space on the improvement of the pedestrian area of space (physical and psychological) and gait characteristics, service levels and basic data. 3. Chose how to extract the most appropriate of the best alternatives presented several proposals based on the above survey of the literature data and field survey.
The mass transit networks in Korea, such as buses, metro and subway, are co-related and the number of transfer points, in which a lot of pedestrian movement is generated, are rising. The functions of the transfer centers, in which several travel modes cross at a point, have to include convenience and comfort for pedestrians using the transfer centers, and such functions can make transit a more attractive travel option and thus eventually contribute to increases in ridership. However, the guidelines for station layouts and their assessments in transfer stations are not suggested so far. So the pedestrian pattern data (pedestrian walking distances and times, pedestrian approaching distances and times, pedestrian walking paths in the inside of stations) was collected and analyzed. Based on the results of the analysis, the ways to measure the quality of comfort for those who using transfer facilities were suggested using the times that pedestrians consume to transfer from a travel mode to another. The walking time of pedestrians at the inside of stations was also measured by pre-selected pedestrian pathways as the guidelines for station layout assessment in transfer facilities.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.